Karadeniz Powership Ayberk Bey
IMO/VIN
Callsign
Flag
Service
Year
9359600
V7CU6
MARSHALL ISLANDS
Tank Ship
2006
Activity#
Port
Date
Activity - Description
Deficiencies
7244620
Port Arthur, Texas
Jul 05, 21
Vessel Inspection - Agency Action Complete
6944412
BATON ROUGE, Louisiana
Apr 27, 20
Vessel Inspection - Approved Inspection
6668607
Houston, Texas
May 05, 19
Vessel Inspection - Approved Inspection
6671881
Houston, Texas
Apr 28, 19
Boarding - Agency Action Complete
6585188
PHILADELPHIA, Pennsylvania
Nov 22, 18
Vessel Operational Control - Agency Action Complete
6585184
STATEN ISLAND, New York
Nov 22, 18
Vessel Operational Control - Agency Action Complete
6423336
San Juan, Puerto Rico
May 29, 18
Vessel Inspection - Approved Inspection
6363317
Houston, Texas
Mar 05, 18
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Deck/Cargo Cargo Transfer/Lightering (liquid)
Description Due Date Resolved 1150-THE CONDITIONS OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE CODE TO ENSURE THAT THE SHIP WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ABOARD OR WITHOUT PRESENTING AN UNREASONABLE THREAT OF HARM TO THE MARINE ENVIRONMENT.
DURING EMERGENCY SHUTDOWN TESTS, PSCO'S OBSERVED CARGO PUMP CONTROLS FOR PORT SLOP TANK. CARGO TANKS 2P, 6S IN DICATED PRESSURE UP TO 100BARS. CARGO PUMPS WERE NOT RUNNING. 74SOLAS(2014) VII/10.1 IBC CODE 1.5.3.1 16AC Mar 19, 18 Yes
Resolved Date Resolution Mar 11, 18 Received Class Survey Report attesting to the rectification of cargo pump system to include servicing and renewal of hydraulic pressure transmitter.
6296640
Houston, Texas
Oct 28, 17
Vessel Inspection - Administrative Action
6257396
CORPUS CHRISTI, Texas
Sep 02, 17
Vessel Inspection - Agency Action Complete
6134488
CORPUS CHRISTI, Texas
May 05, 17
Vessel Inspection - Agency Action Complete
6219578
WASHINGTON, District of Columbia
Apr 12, 17
Incident Investigation - Agency Action Complete
6099575
Houston, Texas
Mar 10, 17
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Deck/Cargo Cargo Heating Improper/Lack of Maintenance
Description Due Date Resolved The machinery, boilers, and other pressure vessels, associated piping systems, and fittings shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to hot surfaces. Numerous areas of the steam line on deck are in disrepair with regards to lagging and other safety measures. 74 SOLAS (04 Con) II-I/26.1. Yes
Resolved Date Resolution Mar 11, 17 Received, reviewed and accepted class report from DNV-GL stating the deficiency was rectified. The steam pipe lines have been decommissioned and must received full repair if brought back into service.
6102119
TEXAS CITY, Texas
Mar 09, 17
Boarding - Agency Action Complete
6031250
TEXAS CITY, Texas
Oct 30, 16
Vessel Inspection - Approved Inspection
5941713
New Orleans, Louisiana
Jul 15, 16
Vessel Inspection - Approved Inspection
5826577
New Orleans, Louisiana
Mar 04, 16
Vessel Inspection - Administrative Action
5817717
Wilmington, North Carolina
Feb 19, 16
Vessel Inspection - Agency Action Complete
2
0
System Subsystem Cause Electrical Mast Damaged By Earlier Event
Description Due Date Resolved 0950- A main electric lighting system which shall provide illumination throughout those parts of the ship normally accessible to and used by passengers or crew shall be supplied from the main source of electrical power. The forward mast lights and nearby lights have been damaged and are inoperable. Mar 03, 16 Yes
Resolved Date Resolution Mar 03, 16 PSC NOLA received photos of working operations satisfying the requirements.
System Subsystem Cause Deck/Cargo Cargo Heating Improper/Lack of Maintenance
Description Due Date Resolved 0999- The machinery, boilers, and other pressurevessels, associated piping systems, and fittings shall be so installed and protected as to reduce to a minimium any danger to persons on board, due regard being paid to hot surfaces. Numerous areas of the steam line on deck are in disrepair with regards to lagging and other safety measures. Mar 03, 16 Yes
Resolved Date Resolution Mar 03, 16 PSC NOLA received photos of repaired lagging satisfying the requirements.
4321586
MASSENA, New York
May 24, 12
Vessel Inspection - Approved Inspection
4265777
TEXAS CITY, Texas
Mar 22, 12
Boarding - Agency Action Complete
4234791
ST PETERSBURG, Florida
Jan 30, 12
Vessel Inspection - Agency Action Complete
4234791
Tampa, Florida
Jan 30, 12
Vessel Inspection - Agency Action Complete
4206275
PHILADELPHIA, Pennsylvania
Dec 12, 11
Vessel Inspection - Approved Inspection
3562128
MASSENA, New York
Aug 11, 09
Vessel Inspection - Agency Action Complete
3554699
STATEN ISLAND, New York
Aug 03, 09
Vessel Operational Control - Administrative Action
3554378
STATEN ISLAND, New York
Aug 03, 09
Vessel Inspection - Approved Inspection
3543742
MASSENA, New York
Jul 23, 09
Vessel Inspection - Approved Inspection
3184809
MASSENA, New York
Apr 19, 08
Vessel Inspection - Approved Inspection
3170851
MASSENA, New York
Mar 24, 08
Vessel Inspection - Approved Inspection
3137708
Portsmouth, Virginia
Jan 28, 08
Vessel Inspection - Approved Inspection
3078280
MASSENA, New York
Oct 10, 07
Vessel Inspection - Agency Action Complete
3078336
MASSENA, New York
Oct 10, 07
Vessel Inspection - Agency Action Complete
3075921
Buffalo, New York
Oct 08, 07
Vessel Inspection - Approved Inspection
3067299
SOUTH PORTLAND, Maine
Oct 01, 07
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Lifesaving Launching Appliances Improper/Lack of Maintenance
Description Due Date Resolved SOLAS 74 ch.III 20.2, The limit switch to the rescue boat davit system is broken. The crew members were unable to launch and recover the rescue boat satisfactorily. Oct 02, 07 Yes
Resolved Date Resolution Oct 02, 07 The crew reattached the weight to the limit switch and greased the wires of the crane. The rescue boat was able to be launched and recovered in an appropriate amount of time. All was found satisfactory to the Coast Guard Marine Inspector.
2913651
MASSENA, New York
Apr 22, 07
Vessel Inspection - Agency Action Complete
2866147
New Orleans, Louisiana
Feb 02, 07
Vessel Inspection - Administrative Action
2850674
CORPUS CHRISTI, Texas
Jan 06, 07
Vessel Inspection - Approved Inspection
2805046
PHILADELPHIA, Pennsylvania
Oct 21, 06
Vessel Inspection - Approved Inspection
2786692
MASSENA, New York
Oct 05, 06
Vessel Inspection - Agency Action Complete
2786691
MASSENA, New York
Oct 05, 06
Vessel Inspection - Agency Action Complete
2703537
TEXAS CITY, Texas
Jul 09, 06
Vessel Inspection - Approved Inspection
2
0
System Subsystem Cause Pollution Prevention/Response Response Equipment
Description Due Date Resolved Vessel does not have required chemical suits. Prior to discharging cargo vessel must have required chemical suits onboard. Yes
Resolved Date Resolution Jul 10, 06 Vessel has aquired required chemical suits and placed them onboard.
System Subsystem Cause Fire Fighting Fixed Pressure Water-Spraying Fire Extinguishing System
Description Due Date Resolved Vessel's cargo sample locker is not equipped with a fixed fire exinguishing system. Prior to 08 AUG 2006, the administration must attend vessel to ensure vessel is in compliance with SOLAS regulations. Aug 08, 06 Yes
Resolved Date Resolution Oct 20, 06 Received class report from DNV attesting to satisfactory repair of the cargo sample locker.
2705551
Houston, Texas
Jul 08, 06
Boarding - Agency Action Complete
Documents
Issued
Expires
Agency
Certificate of Compliance - Tank Vessel
March 5,2018
March 5,2020
HOUMS
Certificate of Fitness - Chemical Carrier
September 25,2007
January 24,2008
DNV
Classification Document
July 3,2021
October 26,2021
DNV
International Certificate of Fitness - Chemical
July 3,2021
April 26,2026
DNV
International Load Line Certificate
July 6,2021
October 26,2021
DNV
International Oil Pollution Prevention Certificate
July 3,2021
October 26,2021
DNV
ISM - Document Of Compliance
January 19,2006
November 7,2010
GL
ISM - Safety Management Certificate
October 1,2007
March 30,2008
GL
Minimum Safe Manning Document
January 21,2016
MH
NLS Certificate
July 23,2009
December 22,2009
GL
SOLAS Cargo Ship Safety Certificate
June 27,2016
April 26,2021
DNV
SOLAS Cargo Ship Safety Construction Certificate
July 3,2021
October 26,2021
DNV
SOLAS Cargo Ship Safety Equipment Certificate
July 3,2021
October 26,2021
DNV
SOLAS Cargo Ship Safety Radio Certificate
September 25,2007
February 24,2008
DNV
Tonnage Certificate, International
January 23,2016
April 23,2016
DNV