Activity# Port Date Activity - Description Deficiencies
7368843 Houma, Louisiana Dec 16, 21 Vessel Inspection - Approved Inspection
7072074 Houma, Louisiana Oct 06, 20 Vessel Inspection - Agency Action Complete
  2
SystemSubsystemCause
01 - Certificates & Documentation011 - Ships Certificates
DescriptionDue DateResolved
To maintain a valid Certificate of Inspection (COI), you must complete your annual and periodic inspections within the periods specified... and your COI must be endorsed. The vessel was issued a COI on 17DEC2018 to expire 17DEC2023. An annual inspection of the vessel was due between 17SEP2019 and 17MAR2020. The vessel has failed to conduct the annual inspection within the required inspection period and therefore the COI is invalid. A new COI examination shall be conducted prior to carriage of cargo.Oct 05, 20No
SystemSubsystemCause
02 - Structural ConditionsN/A - No Subsystem
DescriptionDue DateResolved
Vessels that operate in salt water must be inspected in accordance with the intervals set forth in table 31.10-21(a). The vessel was required to complete two (2) internal structural examinations (ISE) within a five (5) year period, with no more than three (3) years between any two examinations. The vessel completed an ISE on 31OCT2014 and 17DEC2018, with an ISE being due 31OCT2019. The vessel failed to conduct the ISE as required. An ISE shall be conducted prior to carriage of cargo.Oct 05, 20No
7008756 Houma, Louisiana Jul 15, 20 Vessel Inspection - Approved Inspection
6919303 Houma, Louisiana Mar 03, 20 Vessel Inspection - Approved Inspection
6908128 New Orleans, Louisiana Feb 11, 20 Vessel Inspection - Approved Inspection
6782909 New Orleans, Louisiana Aug 13, 19 Vessel Inspection - Approved Inspection
6754430 CORPUS CHRISTI, Texas Jul 18, 19 Vessel Inspection - Approved Inspection
6678857 New Orleans, Louisiana May 07, 19 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
Each transfer relief valve must open at the pressure at which it is set to open. Two caro pump relief valves were unable to sustaion their desired set pressure at 125psi. Repair or replace relief valves and retest prior to using cargo pumps #1 & #4.Yes
Resolved DateResolution
May 13, 19Reviewed test certs of Safety Relief Valves & found satisfactory.
6674330 CORPUS CHRISTI, Texas Apr 30, 19 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No Subsystem
DescriptionDue DateResolved
46 CFR 35.35-70(b): Cargo pump relief valves shall be tested at least once each year to determine that they function satisfactorily at pressure they are set to open. 04 Cargo pump relief valves were found without clear markings and testing documentation (annual) could not be provided. PRIOR TO DISCHARGE documentation shall be provided to verify annual testing of all cargo Pump relief valves.Yes
Resolved DateResolution
May 07, 19Witnessed sat bench test of 2 relief valves. remain two valves failed test. Issued new 835. See AN: 6678857
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
46 CFR 39.2001(j): each vessel vapor connection flange face must have a permanent stud projecting outward at top of flange face. Stud was found to be broken and not permanently mounted. Prior to using port side Vapor connection stud must be permanantly installed.Aug 15, 19Yes
Resolved DateResolution
Sep 24, 19see narrative
6668643 New Orleans, Louisiana Apr 23, 19 Vessel Inspection - Approved Inspection
6650883 CORPUS CHRISTI, Texas Mar 28, 19 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
04 - Emergency SystemsN/A - No Subsystem
DescriptionDue DateResolved
Manned tank barges and tankships authorized to carry Grade A, B, C, D liquids at any temperature or Grade E liquids at elevated temperatures shall be provided with a combustible gas indicator suitable for determining the presence of explosive concentrations of the cargo carried. New systems were found onboard but installation was not complete and system was inoperable. Complete installation IAW manufacturer’s instructions and demonstrate proper operation to the satisfaction of the attending OCMI.May 27, 19Yes
Resolved DateResolution
Jul 18, 19 The vessel has portable detection devices onboard and meets all requirements as set forth in 46 cfr 35.30-15 and is able to conduct operations with current Gas detection practices and equipment. The system in question is optional and is an addition to es
6251093 ST PETERSBURG, Florida Aug 25, 17 Vessel Inspection - Approved Inspection
  12
SystemSubsystemCause
Construction/LoadlineStructures
DescriptionDue DateResolved
Complete gauging of main deck and centerline bulkheads.Yes
Resolved DateResolution
Feb 27, 18Completed gauging of the main deck.
SystemSubsystemCause
Construction/LoadlineStructures
DescriptionDue DateResolved
Crop and renew deck plating under port ballast pump house.Yes
Resolved DateResolution
Mar 08, 18Steel around the deck house has been replaced. Affected area under will be clad welded.
SystemSubsystemCause
Construction/LoadlineStructures
DescriptionDue DateResolved
Crop and renew deck plating under the stbd ballast pump house.Yes
Resolved DateResolution
Dec 20, 18
SystemSubsystemCause
Construction/LoadlineStructures
DescriptionDue DateResolved
Gauge wasted areas in the cofferdam bulkhead w/ CG and ABS present.Yes
Resolved DateResolution
Mar 21, 18
SystemSubsystemCause
Construction/LoadlineStructures
DescriptionDue DateResolved
Gauge wasted areas in the collision bulkhead w/ CG and ABS present.Yes
Resolved DateResolution
Mar 21, 18
SystemSubsystemCause
Construction/LoadlineStructures
DescriptionDue DateResolved
Gauge wasted areas in the forepeak longitudinal bulkheads w/ CG and ABS present.Yes
Resolved DateResolution
Mar 21, 18
SystemSubsystemCause
Construction/LoadlineStructures
DescriptionDue DateResolved
Provide gauging report for main deck plating IWO bulkhead #60 separating #8 port and stbd cargo tanks and aft void.Yes
Resolved DateResolution
Jan 11, 18
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
Provide gauging report for transverse frames #32 (between #4 and #5 stbd cargo), #39 (between #5 and #6 stbd cargo), and #46 (between # 6 and #7 stbd cargo).Yes
Resolved DateResolution
Jan 11, 18Replaced top 18 inches of each transverse bulkhead.
SystemSubsystemCause
Construction/LoadlineStructures
DescriptionDue DateResolved
Provide gauging report for wastage found on main deck plating IWO collision bulkhead (#4) on both #1 port and starboard cargo tanks just aft of the transverse bulkhead.Yes
Resolved DateResolution
Jan 11, 18
SystemSubsystemCause
Construction/LoadlineStructures
DescriptionDue DateResolved
Provide gauging report on wastage found on #3 port cargo tank expansion dome on vertical bulkhead located just under the hatch cover bolts.Yes
Resolved DateResolution
Dec 20, 18
SystemSubsystemCause
Operations/ManagementVessel Safety Management
DescriptionDue DateResolved
Provide hazardous location plan drawing.Yes
Resolved DateResolution
Dec 11, 17Provided hazardous location drawing.
SystemSubsystemCause
ElectricalElectric Supply System (service)
DescriptionDue DateResolved
Replace all damaged wire armor onboard IAW 46 CFR 111.05-7.Yes
Resolved DateResolution
Dec 20, 18
6251093 Tampa, Florida Aug 25, 17 Vessel Inspection - Approved Inspection
  12
SystemSubsystemCause
Construction/LoadlineStructures
DescriptionDue DateResolved
Complete gauging of main deck and centerline bulkheads.Yes
Resolved DateResolution
Feb 27, 18Completed gauging of the main deck.
SystemSubsystemCause
Construction/LoadlineStructures
DescriptionDue DateResolved
Crop and renew deck plating under port ballast pump house.Yes
Resolved DateResolution
Mar 08, 18Steel around the deck house has been replaced. Affected area under will be clad welded.
SystemSubsystemCause
Construction/LoadlineStructures
DescriptionDue DateResolved
Crop and renew deck plating under the stbd ballast pump house.Yes
Resolved DateResolution
Dec 20, 18
SystemSubsystemCause
Construction/LoadlineStructures
DescriptionDue DateResolved
Gauge wasted areas in the cofferdam bulkhead w/ CG and ABS present.Yes
Resolved DateResolution
Mar 21, 18
SystemSubsystemCause
Construction/LoadlineStructures
DescriptionDue DateResolved
Gauge wasted areas in the collision bulkhead w/ CG and ABS present.Yes
Resolved DateResolution
Mar 21, 18
SystemSubsystemCause
Construction/LoadlineStructures
DescriptionDue DateResolved
Gauge wasted areas in the forepeak longitudinal bulkheads w/ CG and ABS present.Yes
Resolved DateResolution
Mar 21, 18
SystemSubsystemCause
Construction/LoadlineStructures
DescriptionDue DateResolved
Provide gauging report for main deck plating IWO bulkhead #60 separating #8 port and stbd cargo tanks and aft void.Yes
Resolved DateResolution
Jan 11, 18
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
Provide gauging report for transverse frames #32 (between #4 and #5 stbd cargo), #39 (between #5 and #6 stbd cargo), and #46 (between # 6 and #7 stbd cargo).Yes
Resolved DateResolution
Jan 11, 18Replaced top 18 inches of each transverse bulkhead.
SystemSubsystemCause
Construction/LoadlineStructures
DescriptionDue DateResolved
Provide gauging report for wastage found on main deck plating IWO collision bulkhead (#4) on both #1 port and starboard cargo tanks just aft of the transverse bulkhead.Yes
Resolved DateResolution
Jan 11, 18
SystemSubsystemCause
Construction/LoadlineStructures
DescriptionDue DateResolved
Provide gauging report on wastage found on #3 port cargo tank expansion dome on vertical bulkhead located just under the hatch cover bolts.Yes
Resolved DateResolution
Dec 20, 18
SystemSubsystemCause
Operations/ManagementVessel Safety Management
DescriptionDue DateResolved
Provide hazardous location plan drawing.Yes
Resolved DateResolution
Dec 11, 17Provided hazardous location drawing.
SystemSubsystemCause
ElectricalElectric Supply System (service)
DescriptionDue DateResolved
Replace all damaged wire armor onboard IAW 46 CFR 111.05-7.Yes
Resolved DateResolution
Dec 20, 18
6063085 New Orleans, Louisiana Dec 28, 16 Vessel Inspection - Approved Inspection
  2   1
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
Cargo hoses were not labeled with the service intended.Jan 29, 17Yes
Resolved DateResolution
Dec 29, 16Crewmembers properly labeled cargo hoses prior to inspectors departing from the barge.
SystemSubsystemCause
Deck/CargoHolds/Tanks
DescriptionDue DateResolved
PV and HPV testing documentation was incomplete and inaacurate (01 HVPV listed as tested when 02 are installed, vacuum side not tested for both HVPVs and PVs, wrong testing pressure listed for HVPVs and PVs). Do not load cargo until proper HVPV and PV testing certificates are provided.Aug 27, 17Yes
Resolved DateResolution
Dec 30, 16PVs and HVPVs were re-tested and new certificates provided. USCG MI conducted phone interview with testing tech rep and recieved adequate calibration certs for testing equipment used.
SystemSubsystemCause
Deck/CargoCargo HeatingInvalid
DescriptionDue DateResolved
Thermal Fluid Heater (TFH) was locked out/tagged out by operator due to leak into the cargo tanks that couldn't be located. Do not use until USCG MI recieved report of a successful hydro test of the cargo heater lines and witnesses a satisfactory test of alarms and shutdowns.Aug 27, 17No
5791539 New Orleans, Louisiana Jan 06, 16 Vessel Inspection - Approved Inspection
  11
SystemSubsystemCause
Fire FightingFixed Fire Detection System
DescriptionDue DateResolved
2 missing smoke detectors in quarters area.Jan 06, 16Yes
Resolved DateResolution
Jan 06, 16Smoke detectors were located and replaced during inspection.
SystemSubsystemCause
Deck/CargoVapor Control Systems
DescriptionDue DateResolved
P/V valve on forward port vapor line is frozen. Repair/ replace provide documantation for testing.Yes
Resolved DateResolution
Jan 07, 16Witnessed replacement of the VCS p/v valve on vessel and reveiwed report that the new valve has been tested to the proper pressure settings.
SystemSubsystemCause
NavigationCollision/Grounding Avoidance
DescriptionDue DateResolved
Port nav light is inoperable. Replace/repairJan 07, 16Yes
Resolved DateResolution
Jan 07, 16Port running light was replaced and tested with satisfactory results.
SystemSubsystemCause
LifesavingLifejacket/PFD (Type III)
DescriptionDue DateResolved
Post proper life jacket donning placard.Jan 13, 16Yes
Resolved DateResolution
Jan 07, 16Viewed proper lifejacket donning placards are onboard and posted.
SystemSubsystemCause
ElectricalElectrical Distribution System (service)
DescriptionDue DateResolved
Properly lable circuit breaker panels in aft STBD cargo pump room.Feb 06, 16Yes
Resolved DateResolution
Jan 26, 16Received pictures from vessel rep illustarting that the distribution panels have been properly labeled.
SystemSubsystemCause
Operations/ManagementCargo Transfer/Lightering
DescriptionDue DateResolved
Provide and post line diagram.Feb 06, 16Yes
Resolved DateResolution
Jan 26, 16Received picture from vessel rep illustrating the the cargo piping line diagram has been posted in the proper location on the vessel.
SystemSubsystemCause
ElectricalElectrical Distribution System (service)
DescriptionDue DateResolved
Remove stray wire on #1 Gen and by forward pump roomFeb 06, 16Yes
Resolved DateResolution
Jan 26, 16Received report and pictures illustrating the exposed wire has been pulled and the def has been rectified.
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
Repair E-shutdown on FWD STBD cargo pump engine prior to conducting cargo ops with that engine.Yes
Resolved DateResolution
Jan 07, 16Witnessed satisfactory test of the emergency stop system on the cargo pump prime movers.
SystemSubsystemCause
Accommodation/Occupational SafetyPotable Water System
DescriptionDue DateResolved
Repair vent pipe for potable water tank.Feb 06, 16Yes
Resolved DateResolution
Jan 07, 16Witnessed satisfactory repair of the potable water tank vent.
SystemSubsystemCause
Deck/CargoCargo Stowage
DescriptionDue DateResolved
Replace SOPEP and fire suit lockers.Feb 06, 16Yes
Resolved DateResolution
Jan 26, 16Received pictures from vessel rep that the SOPEP and firesuits lockers have been replaced.
SystemSubsystemCause
Deck/CargoCargo Heating
DescriptionDue DateResolved
Vessel was unable to test thermal fluid heater. Prior to loading any cargoes that require TFH, have testing witnessed by a MI.Yes
Resolved DateResolution
Jan 07, 16Tech was onboard and inspectors were able to test all alarms and shutdowns with satisfactory results.
5043482 Port Arthur, Texas Dec 24, 14 Vessel Inspection - Approved Inspection
5013388 New Orleans, Louisiana Oct 31, 14 Vessel Inspection - Approved Inspection
4775456 New Orleans, Louisiana Jan 03, 14 Vessel Inspection - Approved Inspection
4432057 ST PETERSBURG, Florida Sep 04, 12 Vessel Inspection - Approved Inspection
4432057 Tampa, Florida Sep 04, 12 Vessel Inspection - Approved Inspection
4179567 New Orleans, Louisiana Nov 02, 11 Vessel Inspection - Approved Inspection
4160840 Port Arthur, Texas Oct 05, 11 Vessel Inspection - Approved Inspection
  5
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)Improper/Lack of Maintenance
DescriptionDue DateResolved
Cargo pump shall be isolated from source of vapor ignition by a gas tight bulkhead. Shaft penetration through bulkheads are not gas tight.Nov 05, 11Yes
Resolved DateResolution
Nov 02, 11Completed SAT inspection of all cargo pump shaft penetration modifications.
SystemSubsystemCause
Accommodation/Occupational SafetySleeping AccommodationsImproper/Lack of Maintenance
DescriptionDue DateResolved
Each berthing must have a light. Berthing missing headlamps.Nov 05, 11Yes
Resolved DateResolution
Nov 02, 11Completed SAT check of installed rack lighting.
SystemSubsystemCause
LifesavingLifebuoysImproper/Lack of Maintenance
DescriptionDue DateResolved
Lifebouys must be marked with name of vessel and port. Lifebouys are not properly labeled.Nov 05, 11Yes
Resolved DateResolution
Nov 02, 11Completed SAT inspection of properly labeled ring lifebouys.
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)Improper/Lack of Maintenance
DescriptionDue DateResolved
Pressure gage shall be visible from control station from pump. Gages not visible from pump control station.Nov 05, 11Yes
Resolved DateResolution
Nov 02, 11Completed SAT check of pressure gage and ensured visibility form pump control station.
SystemSubsystemCause
Fire FightingCombustible MaterialsInvalid
DescriptionDue DateResolved
Stowage of paint must not have any electrical equipment unless an approved space. Paint currently stored in an unapproved space.Nov 05, 11Yes
Resolved DateResolution
Nov 02, 11Completed SAT inspection of newly installed paint locker.
3923935 New Orleans, Louisiana Jan 10, 11 Vessel Inspection - Approved Inspection
3915035 TEXAS CITY, Texas Dec 21, 10 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
StabilityUnintentional FloodingImproper/Lack of Maintenance
DescriptionDue DateResolved
Properly renew the Port and Starboard running light, electrical cable penetrations through the main deck. (O/O attempted to have MSU GALV clear the deficiency by using red hand epoxy to cover the deteriorated penetration) Advised O/O that if not properly repaired by due date, the barge will be detained until corrected. USCG inspector please verify.Jan 21, 11Yes
Resolved DateResolution
Jan 10, 11Inspectors verified the electrical cable penetrations were properly renewed and in satisfactory condition.
3896270 Cape Canaveral, Florida Nov 22, 10 Vessel Inspection - Approved Inspection
  5
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
Flame screens were found with excess corrosion and debris. All flame screens are to be renewed and in serviceable condition NLT 22 Dec 10.Dec 22, 10Yes
Resolved DateResolution
Dec 21, 10Verified flame screen condition and proper installation
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational Safety
DescriptionDue DateResolved
Prove proper operation of the combustible gas meter.Dec 22, 10Yes
Resolved DateResolution
Dec 21, 10CWO Pesek verified there was on calibrated meter on board and witnessed the calibration of a secont meter.
SystemSubsystemCause
Deck/CargoBallast
DescriptionDue DateResolved
Renew starboard ballast pump angle drive shaft coupling cover.Jan 21, 11Yes
Resolved DateResolution
Jan 10, 11The Starboard ballast pump angle drive shaft coupling was outfitted with a new metallic cover.
SystemSubsystemCause
Fire FightingVentilation Systems
DescriptionDue DateResolved
Renew wasted gasket at aft exhaust louver for thermal fluid heater.Dec 22, 10Yes
Resolved DateResolution
Dec 21, 10CWO Pesek verified proper installation of new gasket in the ventilation cover.
SystemSubsystemCause
ElectricalElectrical Distribution System (service)
DescriptionDue DateResolved
Renew wasted wire supports outside both aft cargo pump rooms, replace missing wire supports at forward overfill alarm sensor, and renew stuffing box tube IWO stbd sidelight.Dec 22, 10Yes
Resolved DateResolution
Dec 21, 10Verified renewal of cable supports
3796496 STATEN ISLAND, New York Jul 15, 10 Vessel Inspection - Approved Inspection
3677664 PHILADELPHIA, Pennsylvania Feb 09, 10 Vessel Inspection - Approved Inspection
3626076 STATEN ISLAND, New York Nov 02, 09 Vessel Inspection - Agency Action Complete
3340217 STATEN ISLAND, New York Oct 07, 08 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
EngineeringDiesel Engine (auxiliary)
DescriptionDue DateResolved
Demonstrate emergency shutdown of #2 stbd side pump engine prior to using pump for cargo operations.Oct 14, 08Yes
Resolved DateResolution
Oct 14, 08Received letter from vessel rep attesting that the shutdown head assembly was replaced, engine shutdown tested and found satisfactory. Deficiency cleared.
2835963 New Orleans, Louisiana Dec 07, 06 Vessel Inspection - Approved Inspection
2743970 Washington, District of Columbia Aug 11, 06 Vessel Inspection - Security Plan Approved by MSC
2586368 STATEN ISLAND, New York Feb 16, 06 Vessel Inspection - Agency Action Complete
2578842 Washington, District of Columbia Feb 03, 06 Vessel Inspection - Administrative Action
2556639 STATEN ISLAND, New York Dec 27, 05 Vessel Inspection - Agency Action Complete
  9
SystemSubsystemCause
EngineeringFuel Oil Service SystemImproper/Lack of Maintenance
DescriptionDue DateResolved
All cargo pump engine's have fuel and lube oil hoses that are well beyond a reasonable service life. Outer fire retardant cover crumbles in hand exposing inner reinforcement. Reinforcement is tacky to the touch indicating that the inner liner is breaking down. Replace all hose as required.Yes
Resolved DateResolution
Dec 27, 05Attended vessel to observe test of newly installed hoses. All F/O and L/O service hose was replaced on all pump engines.
SystemSubsystemCause
ElectricalElectrical Distribution System (service)Improper/Lack of Maintenance
DescriptionDue DateResolved
Dead end wiring hangs from overhead in thermal fluid heater house. Properly terminate or remove.Jan 27, 06Yes
Resolved DateResolution
Feb 17, 06Wire was removed back to breaker panel.
SystemSubsystemCause
Deck/CargoHolds/TanksImproper/Lack of Maintenance
DescriptionDue DateResolved
Flame screen on C/T 3s is holed and will not function as intended. Repair flame screen prior to cargo ops.Yes
Resolved DateResolution
Jan 27, 06Unit repaired on the spot.
SystemSubsystemCause
ElectricalElectrical Distribution System (service)Improper/Lack of Maintenance
DescriptionDue DateResolved
Floodlight switch in thermal fluid heater house is missing cover. Provide proper cover for box.Jan 27, 06Yes
Resolved DateResolution
Feb 17, 06Wire was removed back to breaker panel.
SystemSubsystemCause
EngineeringFuel Oil Service SystemImproper Installation
DescriptionDue DateResolved
Generator engines have hoses in fuel and lube oil service that do not meet 46CFR56.60-25(b). Replace all improper materials accordingly.Jan 27, 06Yes
Resolved DateResolution
Feb 17, 06Hoses have been replaced to comply with 46 CFR 56.60-25(b).
SystemSubsystemCause
Deck/CargoCargo HeatingImproper/Lack of Maintenance
DescriptionDue DateResolved
Prove proper operation of thermal fluid heater including required tests in accordance with 46CFR61.30-20 to the satisfaction of an attending marine inspector. Vessel is restricted from using thermal fluid heater until this requirement is met. Feb 14, 06Yes
Resolved DateResolution
Feb 18, 06Received field service report from technician, certifying the thermal fluid heater for operational use.
SystemSubsystemCause
LifesavingImmersion SuitsImproper/Lack of Maintenance
DescriptionDue DateResolved
Provide immersion suit that is size appropriate for use by the mate, Mr. Monjarres, prior to his sailing outside the boundary.Yes
Resolved DateResolution
Dec 27, 05Observed new "JUMBO" size immersion suit on-board.
SystemSubsystemCause
Deck/CargoCargo HeatingImproper/Lack of Maintenance
DescriptionDue DateResolved
Thermal fluid heater is leaking an excessive amount of combustion gasses from gaps in the sheathing surrounding the unit. Identify the source of exhaust gasses and repairFeb 14, 06Yes
Resolved DateResolution
Feb 18, 06Leaks have been repaired by a certified technician.
SystemSubsystemCause
EngineeringDiesel Engine (auxiliary)Improper/Lack of Maintenance
DescriptionDue DateResolved
Various engine installations have nonjacketed exhaust piping that is not properly insulated IAW ABS Rules. Properly insulate piping accordingly. 46CFR31.10-1Jan 27, 06Yes
Resolved DateResolution
Feb 17, 06Concerned area''s of exhaust piping have been insulated.
2548784 STATEN ISLAND, New York Dec 08, 05 Vessel Transfer Monitor - Administrative Action
2516943 NEW HAVEN, Connecticut Oct 18, 05 Vessel Transfer Monitor - Agency Action Complete
2507292 PHILADELPHIA, Pennsylvania Oct 04, 05 Enforcement - Payment Received
2489993 WASHINGTON, District of Columbia Sep 10, 05 Incident Investigation - Agency Action Complete
2308332 Washington, District of Columbia Mar 11, 05 Vessel Inspection - Security Plan Approved by MSC
2292256 PHILADELPHIA, Pennsylvania Feb 13, 05 Facility Transfer Monitor - Failed Inspection
2218774 STATEN ISLAND, New York Oct 12, 04 Vessel Inspection - Agency Action Complete
2196150 STATEN ISLAND, New York Sep 15, 04 Vessel Inspection - Approved Inspection
2141149 STATEN ISLAND, New York Jul 22, 04 Enforcement - Agency Action Complete
2079856 Washington, District of Columbia May 27, 04 Vessel Inspection - Security Plan Approved by MSC
2063961 PHILADELPHIA, Pennsylvania May 09, 04 Vessel Transfer Monitor - Agency Action Complete
2001575 STATEN ISLAND, New York Feb 06, 04 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
EngineeringDiesel Engine (auxiliary)
DescriptionDue DateResolved
Prior to using newly installed generator, call U.S. Coast Guard for In-Kind inspection. Provide generator specs prior to use.Yes
Resolved DateResolution
Sep 15, 04
1979994 PHILADELPHIA, Pennsylvania Jan 08, 04 Vessel Transfer Monitor - Agency Action Complete
1962289 Washington, District of Columbia Dec 09, 03 Vessel Inspection - ASP Criteria Met
1953633 PHILADELPHIA, Pennsylvania Nov 24, 03 Facility Transfer Monitor - Agency Action Complete
1954795 PHILADELPHIA, Pennsylvania Nov 24, 03 Vessel Inspection - Approved Inspection
1943689 WASHINGTON, District of Columbia Nov 07, 03 Incident Investigation - Agency Action Complete
1732841 STATEN ISLAND, New York Feb 04, 03 Vessel Inspection - Approved Inspection
  5
SystemSubsystemCause
ElectricalLighting (service)Improper/Lack of Maintenance
DescriptionDue DateResolved
Renew extinguished light bulbs in generator space. LEGACY COMPONENT DESC: Lighting FixtureMar 04, 03Yes
Resolved DateResolution
Feb 04, 03
SystemSubsystemCause
Construction/LoadlineStructuresImproper/Lack of Maintenance
DescriptionDue DateResolved
Renew gasket on generator house door. LEGACY COMPONENT DESC: DoorMar 04, 03Yes
Resolved DateResolution
Nov 24, 03
SystemSubsystemCause
Construction/LoadlineStructuresImproper/Lack of Maintenance
DescriptionDue DateResolved
Renew gaskets on FWD Port & Starboard cargo pump engine intake vent covers. LEGACY COMPONENT DESC: VentilatorsMar 04, 03Yes
Resolved DateResolution
Nov 24, 03
SystemSubsystemCause
EngineeringFuel Oil Service SystemImproper/Lack of Maintenance
DescriptionDue DateResolved
Renew/Repair fuel oil return line on fwd starboard cargo pump engine.Mar 04, 03Yes
Resolved DateResolution
Feb 04, 03
SystemSubsystemCause
ElectricalElectrical Distribution System (service)Improper/Lack of Maintenance
DescriptionDue DateResolved
Repair ground detection light malfunction on panel in generator space. LEGACY COMPONENT DESC: Ground DetectionMar 04, 03Yes
Resolved DateResolution
Nov 24, 03
1702601 PHILADELPHIA, Pennsylvania Nov 04, 02 Facility Transfer Monitor - Agency Action Complete
1672854 PHILADELPHIA, Pennsylvania Sep 06, 02 Vessel Inspection - Approved Inspection
  9
SystemSubsystemCause
EngineeringDiesel Engine (auxiliary)Improper/Lack of Maintenance
DescriptionDue DateResolved
Noted severe oil leaks on aft outboard cargo pumps prime mover. Provide repairs to this main diesel enging to correct oil sling and blow by. To be completed prior to the vessels next cargo operation "discharge". LEGACY COMPONENT DESC: CrankcaseSep 30, 02Yes
Resolved DateResolution
Feb 04, 03
SystemSubsystemCause
EngineeringDiesel Engine (auxiliary)Improper/Lack of Maintenance
DescriptionDue DateResolved
Prior to placing port side outbard main generator set in operation, repair fuel leaks on or throught the fuel system of this gen set and replacemissing/loose rectifier cover on this genset. LEGACY COMPONENT DESC: Fuel leaksSep 30, 02Yes
Resolved DateResolution
Feb 04, 03
SystemSubsystemCause
LifesavingInflatable LiferaftsImproper/Lack of Maintenance
DescriptionDue DateResolved
Prior to the vessel's departure from the port of Philadelphia, later modified to prior to operating as a manned barge, provide service to the vessel's 6 man life raft. LEGACY COMPONENT DESC: ServicingSep 30, 02Yes
Resolved DateResolution
Feb 04, 03
SystemSubsystemCause
CommunicationsRadio CommunicationsImproper/Lack of Maintenance
DescriptionDue DateResolved
Prior to the vessels departure from the port of Philadelphia/later modified to prior to operating as a manned barge, replace broken EPIRB and replace outdated hydro-release and broken hydro-release pin. LEGACY COMPONENT DESC: EPIRBSep 30, 02Yes
Resolved DateResolution
Feb 04, 03
SystemSubsystemCause
LifesavingInflatable LiferaftsImproper/Lack of Maintenance
DescriptionDue DateResolved
Prior to the vessl'e departure from the port of Philadelphia/later modified to prior to operating as a manned barge, properly afix serviced 6 man life raft to the barge via painter to vessel with an approved weak link in accordance with 46CFR199.190 or 46CFR199.175. LEGACY COMPONENT DESC: Weak LinkSep 30, 02Yes
Resolved DateResolution
Feb 04, 03
SystemSubsystemCause
Fire FightingMiscellaneous ItemsImproper/Lack of Maintenance
DescriptionDue DateResolved
Provide attentionto the vessel's housekeeping and eliminate fire hazards noted in standing lube oil in drip pans, oily rags left on deck in way of apparent fuel leaks, open buckets of lube oil in all machinery spaces and noted oil blow by from deck machinery on deck and bulkheads in the generator s LEGACY COMPONENT DESC: Waste ReceptaclesSep 30, 02Yes
Resolved DateResolution
Feb 04, 03
SystemSubsystemCause
ElectricalLighting (service)Improper/Lack of Maintenance
DescriptionDue DateResolved
Repair or replace extinguished deck lighting in way of aft cabin deck house. LEGACY COMPONENT DESC: Lighting FixtureSep 30, 02Yes
Resolved DateResolution
Feb 04, 03
SystemSubsystemCause
EngineeringDiesel Engine (auxiliary)Improper/Lack of Maintenance
DescriptionDue DateResolved
Replace missing exhaust lagging on cargo pump aft outboard and forward starboard prior to these pumps being placed in operation or prior to the next cargo operation. LEGACY COMPONENT DESC: Exhaust blankets (lagging)Sep 30, 02Yes
Resolved DateResolution
Feb 04, 03
SystemSubsystemCause
EngineeringDiesel Engine (auxiliary)Improper/Lack of Maintenance
DescriptionDue DateResolved
Replace missing exhaust pipe blanket (lagging) on port outboard generator set. LEGACY COMPONENT DESC: Piping (exhaust)Sep 30, 02Yes
Resolved DateResolution
Feb 04, 03
1640740 PHILADELPHIA, Pennsylvania Jul 03, 02 Facility Transfer Monitor - Administrative Action
1632987 STATEN ISLAND, New York Jun 18, 02 Vessel Transfer Monitor - Agency Action Complete
1613381 STATEN ISLAND, New York May 06, 02 Enforcement - Payment Received
1608099 Cape Canaveral, Florida Apr 16, 02 Vessel Transfer Monitor - Agency Action Complete
1495901 WASHINGTON, District of Columbia Mar 21, 02 Incident Investigation - Agency Action Complete
1491131 STATEN ISLAND, New York Mar 05, 02 Vessel Inspection - Agency Action Complete
1477747 PHILADELPHIA, Pennsylvania Jan 09, 02 Vessel Transfer Monitor - Failed Inspection
1370400 STATEN ISLAND, New York Nov 07, 01 Vessel Inspection - Agency Action Complete
518094 NEW HAVEN, Connecticut Aug 29, 01 Vessel Transfer Monitor - Agency Action Complete
1450647 STATEN ISLAND, New York Jun 28, 01 Vessel Inspection - Agency Action Complete
1067768 NEW HAVEN, Connecticut Jun 27, 01 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Deck/CargoUnknown
DescriptionDue DateResolved
REPLACE ANCHOR THAT WAS LOST OFF OF BRIDGEPORT, CT ON 26 JUNE 2001. Jun 27, 01Yes
Resolved DateResolution
Jun 27, 01
1604461 WASHINGTON, District of Columbia Jun 26, 01 Incident Investigation - Agency Action Complete
1056071 STATEN ISLAND, New York Nov 21, 00 Vessel Inspection - Administrative Action
1384607 STATEN ISLAND, New York Nov 20, 00 Vessel Inspection - Agency Action Complete
  3
SystemSubsystemCause
Construction/LoadlineUnknown
DescriptionDue DateResolved
C/R cracked sideshell #1S C/T IWO bays 3 & 4 and SSL's 12 & 13. Approx. 4' x 4'. Vsl is not to conduct commercial ops until cleared by USCG. Air test at 1.5 psig upon completion of repairs. This item may be completed to the satisfaction of ABS or the USCG. Nov 21, 00Yes
Resolved DateResolution
Nov 21, 00
SystemSubsystemCause
EngineeringUnknown
DescriptionDue DateResolved
Provide an accurate hand tach to conduct overspeed tests on #1 & 2 generators. Not to exceed 115% of rated speed. Nov 21, 00Yes
Resolved DateResolution
Nov 21, 00
SystemSubsystemCause
ElectricalUnknown
DescriptionDue DateResolved
Renew ground detector lamps on switchboard and prove SAT operation. Nov 20, 00Yes
Resolved DateResolution
Nov 21, 00
453613 STATEN ISLAND, New York Oct 22, 00 Vessel Transfer Monitor - Agency Action Complete
465800 ST PETERSBURG, Florida Jul 28, 00 Vessel Transfer Monitor - Agency Action Complete
465800 Tampa, Florida Jul 28, 00 Vessel Transfer Monitor - Agency Action Complete
153329 WASHINGTON, District of Columbia Jun 01, 00 Incident Investigation - Agency Action Complete
1432255 STATEN ISLAND, New York Feb 02, 00 Vessel Inspection - Agency Action Complete
1456774 ST PETERSBURG, Florida Nov 19, 99 Vessel Inspection - Agency Action Complete
1456774 Tampa, Florida Nov 19, 99 Vessel Inspection - Agency Action Complete
1031514 New Orleans, Louisiana Sep 21, 99 Vessel Inspection - Agency Action Complete
157151 WASHINGTON, District of Columbia Sep 20, 99 Incident Investigation - Agency Action Complete
486940 ST PETERSBURG, Florida Mar 07, 99 Vessel Transfer Monitor - Agency Action Complete
486940 Tampa, Florida Mar 07, 99 Vessel Transfer Monitor - Agency Action Complete
1122780 Houston, Texas Jan 22, 99 Vessel Inspection - Agency Action Complete
437411 NEW HAVEN, Connecticut Dec 17, 98 Vessel Transfer Monitor - Agency Action Complete
519949 PHILADELPHIA, Pennsylvania Sep 24, 98 Vessel Transfer Monitor - Agency Action Complete
499788 Woods Hole, Massachusetts Jul 21, 98 Vessel Transfer Monitor - Agency Action Complete
1111052 STATEN ISLAND, New York Nov 26, 97 Vessel Inspection - Agency Action Complete
  8
SystemSubsystemCause
Fire FightingUnknown
DescriptionDue DateResolved
INSTALL (2) BII PORTABLE FIRE EXTINGUISHERS ON CARGO DECK. Dec 01, 97Yes
Resolved DateResolution
Dec 01, 97
SystemSubsystemCause
ElectricalUnknown
DescriptionDue DateResolved
INSTALL BLANK OVER OPEN CIRCUIT BREAKER OPENING IN AFT PUMPROOM. Dec 01, 97Yes
Resolved DateResolution
Dec 01, 97
SystemSubsystemCause
LifesavingUnknown
DescriptionDue DateResolved
INSTALL COVERS OVER START BATTERIES ON ALL ENGINES. Dec 01, 97Yes
Resolved DateResolution
Dec 01, 97
SystemSubsystemCause
LifesavingUnknown
DescriptionDue DateResolved
INSTALL RETRO-REFLECTIVE TAPE ON RING BUOYS. Dec 01, 97Yes
Resolved DateResolution
Dec 01, 97
SystemSubsystemCause
LifesavingUnknown
DescriptionDue DateResolved
REMOVE/REPLACE EPIRB. Dec 01, 97Yes
Resolved DateResolution
Dec 01, 97
SystemSubsystemCause
LifesavingUnknown
DescriptionDue DateResolved
REPLACE BURNT OUT LIGHTING IN ALL PUMPHOUSE AND ENGINE ROOMS. Dec 01, 97Yes
Resolved DateResolution
Dec 01, 97
SystemSubsystemCause
Fire FightingUnknown
DescriptionDue DateResolved
REPLACE FLAME SCREENS ON CARGO TANK PV VALVES 1 STBD, 2 STBD, 4 STBD, 8 STBD. Dec 01, 97Yes
Resolved DateResolution
Dec 01, 97
SystemSubsystemCause
LifesavingUnknown
DescriptionDue DateResolved
WIPE UP EXCESS OIL AND FUEL UNDER ALL ENGINES. Dec 01, 97Yes
Resolved DateResolution
Dec 01, 97
753480 NEW HAVEN, Connecticut Oct 23, 97 Enforcement - Payment Received
472899 NEW HAVEN, Connecticut Oct 23, 97 Vessel Transfer Monitor - Agency Action Complete
197487 WASHINGTON, District of Columbia Oct 23, 97 Incident Investigation - Agency Action Complete
539384 ST PETERSBURG, Florida Nov 13, 96 Vessel Transfer Monitor - Agency Action Complete
539384 Tampa, Florida Nov 13, 96 Vessel Transfer Monitor - Agency Action Complete
1380676 New Orleans, Louisiana Oct 22, 96 Vessel Inspection - Agency Action Complete
1414703 New Orleans, Louisiana Oct 11, 96 Vessel Inspection - Agency Action Complete
102888 WASHINGTON, District of Columbia Oct 06, 96 Incident Investigation - Agency Action Complete
436254 ST PETERSBURG, Florida Jul 16, 96 Vessel Transfer Monitor - Agency Action Complete
436254 Tampa, Florida Jul 16, 96 Vessel Transfer Monitor - Agency Action Complete
188344 WASHINGTON, District of Columbia Feb 10, 96 Incident Investigation - Agency Action Complete
518183 ST PETERSBURG, Florida Jan 05, 96 Vessel Transfer Monitor - Agency Action Complete
518183 Tampa, Florida Jan 05, 96 Vessel Transfer Monitor - Agency Action Complete
1363477 Port Arthur, Texas Dec 11, 95 Vessel Inspection - Agency Action Complete
1463204 New Orleans, Louisiana Nov 30, 95 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
EngineeringUnknown
DescriptionDue DateResolved
REBRICK REFRACTORY IN THERMAL FLUID HEATER, PROVE PROPER OPERATION OF TFH AND CONDUCT ALL FIELD TEST PROCEDURES IN THE PRESENCE OF A MARINE INSPECTORPRIOR TO OPERATION OF THERMAL FLUID HEATER. Nov 30, 95Yes
Resolved DateResolution
Nov 30, 95
517146 ST PETERSBURG, Florida May 30, 95 Vessel Transfer Monitor - Agency Action Complete
517146 Tampa, Florida May 30, 95 Vessel Transfer Monitor - Agency Action Complete
1155245 STATEN ISLAND, New York Feb 13, 95 Vessel Inspection - Agency Action Complete
671303 Alameda, California Oct 12, 94 Enforcement - Payment Received
122089 WASHINGTON, District of Columbia Sep 23, 94 Incident Investigation - Agency Action Complete
1165109 Houston, Texas Feb 06, 94 Vessel Inspection - Agency Action Complete
849381 ST PETERSBURG, Florida Dec 01, 93 Vessel Inspection - Agency Action Complete
  3
SystemSubsystemCause
ElectricalUnknown
DescriptionDue DateResolved
Blank off openings in 120v power panel in aft cargo pump room. Dec 01, 93Yes
Resolved DateResolution
Dec 01, 93
SystemSubsystemCause
Deck/CargoUnknown
DescriptionDue DateResolved
Hydro statically test all cargo trasfer hoses. Dec 01, 93Yes
Resolved DateResolution
Dec 01, 93
SystemSubsystemCause
Construction/LoadlineUnknown
DescriptionDue DateResolved
Repair water tight door on stbd side of accommodation space. Dec 01, 93Yes
Resolved DateResolution
Dec 01, 93
849381 Tampa, Florida Dec 01, 93 Vessel Inspection - Agency Action Complete
  3
SystemSubsystemCause
ElectricalUnknown
DescriptionDue DateResolved
Blank off openings in 120v power panel in aft cargo pump room. Dec 01, 93Yes
Resolved DateResolution
Dec 01, 93
SystemSubsystemCause
Deck/CargoUnknown
DescriptionDue DateResolved
Hydro statically test all cargo trasfer hoses. Dec 01, 93Yes
Resolved DateResolution
Dec 01, 93
SystemSubsystemCause
Construction/LoadlineUnknown
DescriptionDue DateResolved
Repair water tight door on stbd side of accommodation space. Dec 01, 93Yes
Resolved DateResolution
Dec 01, 93
1132941 Port Arthur, Texas Jan 27, 93 Vessel Inspection - Agency Action Complete
1444696 New Orleans, Louisiana Jan 21, 93 Vessel Inspection - Agency Action Complete
  3
SystemSubsystemCause
Construction/LoadlineUnknown
DescriptionDue DateResolved
BARGE IS TO PROCEED TO TEXAS DRYDOCK CO., ORANGE, TX FOR DRYDOCK (HULL) EXAMINATION. VESSEL IS NOT TO TAKE CARGO IN TRANSIT. DRYDOCK EXAM TO BE PERFORMED BY COGNIZANT OCMI. Jan 21, 93Yes
Resolved DateResolution
Jan 21, 93
SystemSubsystemCause
ElectricalUnknown
DescriptionDue DateResolved
TEST (OVERSPEED) TRIP ON INBOARD GENERATOR #2 IN THE PRESENCE OF CG MARINE INSPECTOR.  Jan 29, 93Yes
Resolved DateResolution
Jan 22, 93
SystemSubsystemCause
EngineeringUnknown
DescriptionDue DateResolved
THERMAL FLUID HEATER IS TO BE SATISFACTORILY OPERATED AND TESTED AS PER 46 CFR 61.30-20. TFH MUST BE TESTED IN THE PRESENCE OF CG MARINE INSPECTOR. TFH SHALL NOT BE USED TO HEAT CARGO OR OPERATED FOR TRANSFERS UNTIL TESTED. Jan 21, 93Yes
Resolved DateResolution
Jan 21, 93
953031 ST PETERSBURG, Florida Dec 13, 91 Vessel Inspection - Agency Action Complete
953031 Tampa, Florida Dec 13, 91 Vessel Inspection - Agency Action Complete
1232759 Miami Beach, Florida Mar 01, 91 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
NavigationUnknown
DescriptionDue DateResolved
RENEW EPIRB BATTERY. Mar 01, 91Yes
Resolved DateResolution
Mar 01, 91
1232746 New Orleans, Louisiana Dec 21, 89 Vessel Inspection - Agency Action Complete
Documents Issued Expires Agency
Cargo Authority Attachment October 5,2012 N/A
CERTIFICATE OF DOCUMENTATION August 23,2021 August 31,2022 USCG
Certificate of Inspection October 5,2012 October 5,2017 N/A
Certificate of Inspection - Amended October 5,2012 October 5,2017 N/A
Classification Document June 3,2014 August 27,2017 N/A
International Load Line Certificate October 5,2012 October 27,2017 N/A
International Oil Pollution Prevention Certificate October 5,2012 October 5,2017 N/A
Int'l Oil Poll Prevention, Form B Supplement December 17,2018 N/A
Load Line Certificate (Coastwise) October 12,2004 October 12,2009 ABS
Stability Letter August 27,2007 N/A
Tonnage Certificate, International August 27,2007 ABS