IMO/VIN
Callsign
Flag
Service
Year
9326926
ZCEP5
DENMARK
Tank Ship
2008
Activity#
Port
Date
Activity - Description
Deficiencies
7420890
Houston, Texas
Apr 04, 22
Vessel Inspection - Approved Inspection
7309849
New Orleans, Louisiana
Sep 11, 21
Vessel Inspection - Administrative Action
7151309
TEXAS CITY, Texas
Mar 09, 21
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause 11 - Life Saving Appliances N/A - No Subsystem Improper/Lack of Maintenance
Description Due Date Resolved Every rescue boat shall be capable of manuvering at a speed of at least 6 knots.
PSCO observed that the rescue boat engine was unable to increase RPM and operate at required speed. Company was notified on 20JAN2021. Plan for repair has not been finalized. Yes
Resolved Date Resolution Mar 15, 21
6910766
San Juan, Puerto Rico
Feb 25, 20
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause 07 - Fire Safety N/A - No Subsystem
Description Due Date Resolved Fire protection systems and fire-fighting systems and appliances shall be properly tested and inspected. PSCO found the CO2 system bottle for the main deisel engine fixed fire-fighting system has not been tested in the past 3 years.
SOLAS (2014) II-2/ Reg 14.1.2 Feb 25, 20 Yes
Resolved Date Resolution Feb 28, 20 Received technician report for the testing of the CO2 Canister.
6758553
San Juan, Puerto Rico
Jul 23, 19
Vessel Inspection - Approved Inspection
6519878
Lake Charles, Louisiana
Aug 26, 18
Vessel Inspection - Approved Inspection
6173170
PORT ARANSAS, Texas
Jun 11, 17
Boarding - Agency Action Complete
6170688
CORPUS CHRISTI, Texas
Jun 09, 17
Vessel Operational Control - Agency Action Complete
6120113
Ponce, Puerto Rico
Apr 18, 17
Vessel Inspection - Approved Inspection
5827948
New Orleans, Louisiana
Mar 07, 16
Vessel Inspection - Administrative Action
5818266
Houston, Texas
Feb 19, 16
Vessel Inspection - Approved Inspection
5107617
Houston, Texas
Apr 28, 15
Vessel Inspection - Approved Inspection
5033244
New Orleans, Louisiana
Dec 03, 14
Vessel Operational Control - Agency Action Complete
4838915
Portsmouth, Virginia
Apr 20, 14
Vessel Inspection - Approved Inspection
4512052
Lake Charles, Louisiana
Jan 06, 13
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Construction/Loadline Hull
Description Due Date Resolved 0999 Ship shall be designed, constructed and maintained in compliance with the structural requirements of a classification society. Ship has grounded due to the tide. Tanks have been sounded with no problems detected. Requires survey to verify there is no hull damage. 74 SOLAS 04 con. II-I/ A3-1
Yes
Resolved Date Resolution Jan 08, 13 Lloyd''''s Register conducted a survey of the starboard side ballast water tanks, and steering gear, found them to all be in satisfactory condition.
4502908
NEW HAVEN, Connecticut
Dec 16, 12
Vessel Inspection - Approved Inspection
4500764
BOSTON, Massachusetts
Dec 12, 12
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Deck/Cargo Holds/Tanks
Description Due Date Resolved 1160-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
Cargo tank hatch covers and ullage covers are leakings, allowing cargo to escape on deck. 74 SOLAS (09) I/11(a) [70a] Yes
Resolved Date Resolution Dec 16, 12 Lloyd''s Register Attended vessel and approved/tested repairs to the hatch covers. all repairs were approved by Class
4352487
Lake Charles, Louisiana
Jun 22, 12
Vessel Inspection - Approved Inspection
4349089
ST PETERSBURG, Florida
Jun 19, 12
Vessel Inspection - Approved Inspection
4349089
Tampa, Florida
Jun 19, 12
Vessel Inspection - Approved Inspection
4306808
BOSTON, Massachusetts
May 09, 12
Vessel Inspection - Agency Action Complete
4169602
Houston, Texas
Oct 17, 11
Vessel Inspection - Agency Action Complete
4162505
BOSTON, Massachusetts
Oct 11, 11
Vessel Inspection - Approved Inspection
3
0
System Subsystem Cause Fire Fighting Fire Hoses Improper/Lack of Maintenance
Description Due Date Resolved MULTIPLE FIRE HOSES WERE FOUND IN POOR CONDITION AND LEAKED UNDER PRESSURE. SOLAS 2009, CH I, REG 11 Oct 26, 11 Yes
Resolved Date Resolution Oct 25, 11 Received class report attesting to the repair and proper operation of hoses.
System Subsystem Cause Fire Fighting Fixed Fire Detection System
Description Due Date Resolved THE HYDROCARBON DETECTION SYSTEM IS NOT WORKING CORRECTLY. SOLAS 2009, CHI, REG 11 Nov 08, 11 Yes
Resolved Date Resolution Dec 13, 11 Class submitted a report rectifying the deficiency on 13DEC2011.
System Subsystem Cause Fire Fighting Fire Main Improper/Lack of Maintenance
Description Due Date Resolved THE VALVE HANDLE/STEM WAS FOUND BROKEN ON THE FIRE SEGRAGATION VALVE FORWARD OF FIRE MONITOR #4. SOLAS 2009, CH I, REG 11 Oct 26, 11 Yes
Resolved Date Resolution Oct 25, 11 Received class report. See attached report.
3883397
New Orleans, Louisiana
Nov 02, 10
Vessel Inspection - Administrative Action
3864564
Woods Hole, Massachusetts
Oct 09, 10
Vessel Inspection - Approved Inspection
3776112
Arlington, Virginia
Jun 25, 10
Enforcement - Payment Received
3701269
San Francisco, California
Mar 25, 10
Vessel Inspection - Approved Inspection
10
0
System Subsystem Cause Documentation Logs/Records Improper/Lack of Maintenance
Description Due Date Resolved 0100; Ballast Water Management Training has not been carried out as per section 7 of the plan. Mar 25, 10 Yes
Resolved Date Resolution Mar 25, 10 Spoke with Captain and Chief Officer about conducting Training as per the BWM Manual.
System Subsystem Cause Operations/Management Cargo Transfer/Lightering Improper/Lack of Maintenance
Description Due Date Resolved 0100; Cargo and Bunker Transfer Procedures were not in accordance with the Code of Federal Regulations. Mar 25, 10 Yes
Resolved Date Resolution Mar 25, 10 Gave sample copies of both to the Captain, Chief Officer and Chief Engineer.
System Subsystem Cause Documentation Logs/Records
Description Due Date Resolved 0100; Discussed signing of Declaration of Inspection form with the Captain and Chief Officer. At the time of the inspection the Chief Officer had been the only one on watch in CCR since 22:30, 3/24/2010. Mar 25, 10 Yes
Resolved Date Resolution Mar 25, 10 The Chief Officer had been relieved but the 2nd and 3rd Officers had not signed the lower section of the form. Discussed with Chief Officer requirements for work / rest under STCW.
System Subsystem Cause Accommodation/Occupational Safety Occupational Safety Design Flaw
Description Due Date Resolved 0599; Ladder brackets are broken / cracked for the ladder in the engine room. Repairs must be made to the satisfaction of Class. Ladder is on the starboard side of the engine room leading from the lower deck to the upper deck. Mar 30, 10 Yes
Resolved Date Resolution Apr 09, 10 Welding repairs were carried out by the crew under the direction of Class.
System Subsystem Cause Fire Fighting Combustible Materials
Description Due Date Resolved 0700; Documentation must be provided stating that the grating near the starboard manifold is fire-retardant. Mar 30, 10 Yes
Resolved Date Resolution Apr 09, 10 Class Representative verified that the grating meets the Reaction to the Fire Performance in accordance with EN 13501 / 1:2007.
System Subsystem Cause Fire Fighting Fixed Fire Detection System Improper/Lack of Maintenance
Description Due Date Resolved 0700; The flame detection system and heat detection system is being checked by the Electrician. To check these systems he is disconnecting the wires only. He does not have the proper equipment for the testing of the systems. A request was sent to the company in August 2009, but the company has not replied, ISM 8 /10. Mar 30, 10 Yes
Resolved Date Resolution Apr 09, 10 Class verified that the proper equipment for checking the flame detectors has been provided. Testing of the system using the equipment was also verified by Class.
System Subsystem Cause Electrical Electric Generation Source (service) Improper/Lack of Maintenance
Description Due Date Resolved 0950; Electrical grounding straps were missing on light outside forward deck store, supply fan to work shop and vent on starboard store room. Mar 25, 10 Yes
Resolved Date Resolution Mar 25, 10 Electrical engineer replaced all grounding straps prior to us departing the vessel.
System Subsystem Cause Fire Fighting Self-contained Breathing Apparatus
Description Due Date Resolved 0999; The maintenance for the Bauer Compressor has not been carried out as per the manufacturer’s requirements, ISM 8 / 10. Mar 30, 10 Yes
Resolved Date Resolution Apr 09, 10 Record of Maintenance has been carried out as per the manufacturers requirements and verified by Class.
System Subsystem Cause Documentation Safety/Response Plans/Programs Improper/Lack of Maintenance
Description Due Date Resolved 1999; Local Contact numbers as per section 2.4.6 Appendix "D" are missing in the SMPEP, MARPOL Annex II / 37. Mar 25, 10 Yes
Resolved Date Resolution Mar 25, 10 Spoke with the Captain about same.
System Subsystem Cause Documentation Logs/Records Improper/Lack of Maintenance
Description Due Date Resolved 2120; Mixed garbage was found in various containers throughout the vessel, which included the final collection point prior to discharging garbage into the sea. Mar 25, 10 Yes
Resolved Date Resolution Mar 25, 10 Spoke with Captain, Chief Officer and Chief Engineer about same.
3619699
Woods Hole, Massachusetts
Oct 23, 09
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Operations/Management Vessel Safety Management
Description Due Date Resolved An external audit of SMS is recommended by the admin due to the severity of the defs discovered with the vsls training, crews familiarization & cargo handling prior to departure. Objective Evidence: 1. Vsl discovered in U. S. port of Boston with C/T's at a negative pressure environment & with a 20% oxygen level. 2. Crew not...SEE ACTIVITY #3619699 for complete issued deficiency. (Code 30 B) Oct 23, 09 Yes
Resolved Date Resolution Oct 24, 09
3618199
BOSTON, Massachusetts
Oct 20, 09
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Deck/Cargo Inert Gas System Placed in Improper Service
Description Due Date Resolved The vessel is required to amend the written cargo transfer procedures to specifically identify when to operate, how to operate and who to notify in the event of a failure of the IG system and this is to be approved by Lloyds Register PRIOR TO ARRIVAL at the next cargo discharge port. Only at that point will this vessel be allowed to continue to discharge cargo at the next cargo discharge port. Oct 21, 09 Yes
Resolved Date Resolution Oct 23, 09
3623832
WASHINGTON, District of Columbia
Oct 20, 09
Incident Investigation - Agency Action Complete
3583834
New Orleans, Louisiana
Sep 03, 09
Vessel Inspection - Approved Inspection
3580522
New Orleans, Louisiana
Sep 02, 09
Boarding - Agency Action Complete
3580571
New Orleans, Louisiana
Aug 30, 09
Vessel Inspection - Administrative Action
3377209
Warrenton, Oregon
Dec 08, 08
Vessel Inspection - Approved Inspection
3375631
Warrenton, Oregon
Dec 07, 08
Vessel Operational Control - Agency Action Complete
3376194
WASHINGTON, District of Columbia
Dec 06, 08
Incident Investigation - Agency Action Complete
3357371
New Orleans, Louisiana
Nov 04, 08
Vessel Inspection - Administrative Action
3339428
San Juan, Puerto Rico
Oct 10, 08
Vessel Inspection - Approved Inspection
3338330
San Juan, Puerto Rico
Oct 04, 08
Vessel Operational Control - Agency Action Complete
3223089
New Orleans, Louisiana
May 31, 08
Vessel Inspection - Administrative Action
3219990
ST PETERSBURG, Florida
May 28, 08
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Pollution Prevention/Response Prevention Equipment
Description Due Date Resolved Vessel's #1 starboard cargo tank "overfill" alarm was found inoperable; further examination determined that a electrical connection was fouled due to water intrusion. Vessel's electrician by-passed the connection and the over-fill alarm is operable. Yes
Resolved Date Resolution May 30, 08
3219990
Tampa, Florida
May 28, 08
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Pollution Prevention/Response Prevention Equipment
Description Due Date Resolved Vessel's #1 starboard cargo tank "overfill" alarm was found inoperable; further examination determined that a electrical connection was fouled due to water intrusion. Vessel's electrician by-passed the connection and the over-fill alarm is operable. Yes
Resolved Date Resolution May 30, 08
Documents
Issued
Expires
Agency
Certificate of Compliance - Tank Vessel
August 26,2018
August 26,2020
N/A
Certificate of Fitness - Chemical Carrier
February 1,2015
June 30,2015
LR
Classification Document
October 28,2016
April 28,2018
N/A
COC-TVE Renewal
May 29,2008
May 29,2010
N/A
International Certificate of Fitness - Chemical
April 16,2015
April 28,2018
LR
International Load Line Certificate
June 10,2021
April 28,2023
DNV
International Oil Pollution Prevention Certificate
January 10,2022
April 28,2023
DNV
ISM - Document Of Compliance
September 25,2008
October 13,2013
ABS
ISM - Safety Management Certificate
September 9,2019
September 9,2024
BM
Minimum Safe Manning Document
April 27,2016
December 30,2021
N/A
SOLAS Cargo Ship Safety Construction Certificate
January 10,2022
April 28,2023
DNV
SOLAS Cargo Ship Safety Equipment Certificate
January 10,2022
April 28,2023
DNV
SOLAS Cargo Ship Safety Radio Certificate
June 20,2016
April 28,2018
N/A