Rtc 60
Print Q88   
IMO/VIN Callsign Flag Service Year
1226399 WCX3683 UNITED STATES Tank Barge 2010
Activity# Port Date Activity - Description Deficiencies
7294057 STATEN ISLAND, New York Aug 23, 21 Vessel Inspection - Agency Action Complete
7060278 STATEN ISLAND, New York Sep 22, 20 Vessel Inspection - Approved Inspection
6689362 STATEN ISLAND, New York May 21, 19 Vessel Inspection - Approved Inspection
6451634 STATEN ISLAND, New York Jun 22, 18 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
P/V valves no longer meets the specification and testing as required for compliance. Pressure side of P/V valve was seized.Jun 22, 18Yes
Resolved DateResolution
Jun 22, 18Deficiency corrected on the spot.
SystemSubsystemCause
09 - Working and Living Conditions091 - Living ConditionsImproper Installation
DescriptionDue DateResolved
Tank vessels are prohibited from having a grounded distribution system. Range and Dryer installation is installed with a neutral conductor. Neutral conductors are required to be connected to ground.Jul 22, 18Yes
Resolved DateResolution
Jul 19, 18Marine Inspector attended and vessel compnay completely removed all machinery not in compliance with ground detection.
6149955 STATEN ISLAND, New York May 19, 17 Vessel Inspection - Approved Inspection
5982249 NEW HAVEN, Connecticut Aug 24, 16 Vessel Transfer Monitor - Approved Inspection
5924349 STATEN ISLAND, New York Jun 30, 16 Vessel Inspection - Approved Inspection
5812626 Woods Hole, Massachusetts Feb 10, 16 Vessel Transfer Monitor - Agency Action Complete
5782312 WASHINGTON, District of Columbia Dec 16, 15 Incident Investigation - Agency Action Complete
5176824 STATEN ISLAND, New York Jul 07, 15 Vessel Inspection - Agency Action Complete
  2
SystemSubsystemCause
LifesavingLifejacket/PFD (Type I)
DescriptionDue DateResolved
Each lifejacket and immersion suit must have a light approved under approval series 161.112 securely attached to the shoulder area. All lifejacket and immersion suit light batteries are expired. Replace with approved lights.Jul 22, 15Yes
Resolved DateResolution
Jul 09, 15Verified that new lights have been purchased and placed on vessel.
SystemSubsystemCause
ElectricalElectric Generation Source (service)
DescriptionDue DateResolved
Each propulsion, power, lighting, or distribution system having a neutral bus or conductor must have the neutral grounded. If the voltage of a distribution system is less than 1000 volts, line to line, a tank vessel must not have a grounded distribution system. The dryer and range contain floating neutrals.Aug 08, 15Yes
Resolved DateResolution
Jul 20, 15Vessel has plans to fix this issue on all barges within their fleet that are of a similar construction. Unit will be working woth company to ensure electrical installations are installed correctly.
5147798 STATEN ISLAND, New York Jun 08, 15 Vessel Inspection - Approved Inspection
4973031 STATEN ISLAND, New York Sep 03, 14 Vessel Inspection - Approved Inspection
4797857 STATEN ISLAND, New York Feb 06, 14 Vessel Inspection - Agency Action Complete
4790476 STATEN ISLAND, New York Jan 28, 14 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
Due to extremely cold temperatures, vessel must satisfactorily complete the hydrostatic pressure testing of each loading arm and each transfer pipe system, including each metallic hose, at earliest opportunity but NLT 60 days from the current due date of 01FEB2014. 33 CFR 156.170(c)(4).Apr 01, 14Yes
Resolved DateResolution
Feb 06, 14Received copy of hydrostatic test report. All hoses, piping, gauges and relief valves tested SAT.
4617160 STATEN ISLAND, New York Jun 11, 13 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational Safety
DescriptionDue DateResolved
Handrails need repair in mutliple locations. 2 broken rails on STBD and 1 on Port.Jul 14, 13Yes
Resolved DateResolution
Jul 02, 13Handrails satisfactory replaced throughout the whole vessel.
4455185 STATEN ISLAND, New York Oct 02, 12 Vessel Inspection - Agency Action Complete
4356270 STATEN ISLAND, New York Jul 11, 12 Vessel Inspection - Agency Action Complete
  2
SystemSubsystemCause
EngineeringFuel Oil Storage/Transfer System
DescriptionDue DateResolved
Vessel does not have the correct drip sample device as per Marpol Annex VI, vessel is restricted to domestic route only.Jul 25, 12Yes
Resolved DateResolution
Aug 02, 12Verified correct drip samplers installed on board.
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
Vessel must provide inventory for spill kit and maintain for use at all times.Jul 25, 12Yes
Resolved DateResolution
Aug 02, 12Verified equipment all on board, properly inventoried and labelled.
4369494 STATEN ISLAND, New York Jul 03, 12 Vessel Transfer Monitor - Approved Inspection
4166629 STATEN ISLAND, New York Oct 11, 11 Vessel Transfer Monitor - Approved Inspection
4061007 STATEN ISLAND, New York Jun 17, 11 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
LifesavingLifebuoysImproper Installation
DescriptionDue DateResolved
Life Ring bracket not permanently affixed.Jul 17, 11Yes
Resolved DateResolution
Jul 14, 11Received photos of repaired life rings.
3950882 STATEN ISLAND, New York Feb 23, 11 Vessel Inspection - Agency Action Complete
3767903 Woods Hole, Massachusetts Jun 16, 10 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
CommunicationsRadio Communications
DescriptionDue DateResolved
Provide proof of registration to RTC 60. Registration has been applied for.Jul 30, 10Yes
Resolved DateResolution
Jul 07, 10Rcvd scanned copy of EPIRB registration sticker.
Documents Issued Expires Agency
Cargo Authority Attachment September 12,2012 N/A
CERTIFICATE OF DOCUMENTATION September 23,2021 October 31,2022 USCG
Certificate of Inspection September 22,2020 September 22,2025 USCG
Certificate of Inspection - Amended June 30,2010 June 30,2015 N/A
Classification Document July 8,2015 July 28,2020 ABS
International Load Line Certificate June 29,2010 June 28,2015 N/A
International Oil Pollution Prevention Certificate June 30,2010 June 30,2015 N/A
Load Line Certificate (Coastwise) June 29,2010 June 28,2015 N/A
Tonnage Certificate, International May 26,2010 N/A
Tonnage Certificate, U.S. May 26,2010 N/A