Rtc 26
Print Q88   
IMO/VIN Callsign Flag Service Year
1200667 WCX3683 UNITED STATES Tank Barge 2007
Activity# Port Date Activity - Description Deficiencies
7448576 STATEN ISLAND, New York May 11, 22 Vessel Inspection - Approved Inspection
7218461 STATEN ISLAND, New York Jun 07, 21 Vessel Inspection - Approved Inspection
6937881 STATEN ISLAND, New York Apr 10, 20 Vessel Inspection - Approved Inspection
6709993 STATEN ISLAND, New York Jun 10, 19 Vessel Inspection - Approved Inspection
  6
SystemSubsystemCause
11 - Life Saving AppliancesN/A - No Subsystem
DescriptionDue DateResolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. The lifebuoys on the starboard bow and port quarter are not serviceable. The grab lines, retro and plugs are deteriorated.Yes
Resolved DateResolution
Jun 12, 19Installed new life rings.
SystemSubsystemCause
11 - Life Saving AppliancesN/A - No Subsystem
DescriptionDue DateResolved
Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. The lights attached to the life jackets are inop.Yes
Resolved DateResolution
Jun 12, 19Installed new lights on the lifejackets.
SystemSubsystemCause
11 - Life Saving AppliancesN/A - No Subsystem
DescriptionDue DateResolved
Liferafts must be readily transferable for launching on either side of the vessel or supplemented with additional liferafts to bring the total capacity of the liferafts available on each side of the vessel to at least 100% of the total persons on board. Only one liferaft was installed on top of the accommodation space preventing side to side transfer.Jun 24, 19Yes
Resolved DateResolution
Oct 17, 19See Notes for agreed upon conditions. Liferaft to be relocated to suitable position at next drydock.
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No Subsystem
DescriptionDue DateResolved
On all tank vessels, where cargo pump shafts pierce gas tight bulkheads, stuffing boxes with readily accessible gas tight glands shall be provided. The starboard bellows that pierces the bulkhead between the starboard cargo pump prime mover and the starboard cargo pump is not gas tight. Rectify deficiency prior to operation of the starboard cargo pump.Jun 24, 19Yes
Resolved DateResolution
Jun 12, 19Installed new bellows creating vapor tight seal.
SystemSubsystemCause
99 - OtherN/A - No Subsystem
DescriptionDue DateResolved
When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by the EPA, the operator must secure each type I, II, or II device in a manner which prevents discharge of treated or untreated sewage. Please provide approval documentation for the type MSD installed on the vessel. No documentation was provided at the time of inspection. No locking device was visible at time of inspection.Yes
Resolved DateResolution
Jun 12, 19Provided proof of approved Type II MSD.
SystemSubsystemCause
09 - Working and Living Conditions091 - Living Conditions
DescriptionDue DateResolved
Where the plans and arrangements will possibly permit, all passageways leading to living quarters, shall be provided with not less than two means of escape. The emergency escape hatch from the accommodation space was inoperable.Yes
Resolved DateResolution
Jun 12, 19Emergency escape hatch has been serviced and is fully operational.
6443862 STATEN ISLAND, New York Jun 14, 18 Vessel Inspection - Approved Inspection
6220711 STATEN ISLAND, New York Jul 25, 17 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Pollution Prevention/ResponsePrevention EquipmentImproper/Lack of Maintenance
DescriptionDue DateResolved
Loss of power alarm on overfill protection is inoperable. To be corrected prior to cargo operations.Yes
Resolved DateResolution
Jul 31, 17Loss of power alarm is now operating correctly.
6109420 Woods Hole, Massachusetts Apr 05, 17 Vessel Inspection - Approved Inspection
  5
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
3P, SSL#3, Bay 2/3, vee and weld crack in SSL and vertical stiffener.Yes
Resolved DateResolution
Apr 12, 17V/W to satisfaction of CG.
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
3P, SSL#6, Bay 1/2, vee and weld crack in SSL and vertical stiffener.Yes
Resolved DateResolution
Apr 12, 17V/W completed to satisifaction of CG.
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
5P, Bay 5 from ffwd, 1 from top, C/R SSV C channel as marked.Yes
Resolved DateResolution
Apr 12, 17C/R to original, all sat by CG.
SystemSubsystemCause
Deck/CargoHolds/Tanks
DescriptionDue DateResolved
Replace 03 P/V valves in kind (Set points: 2.0 PSI Pressure, .5PSI Vacuum. Failed initial testing.Yes
Resolved DateResolution
Apr 25, 17Vessel obtained replacement parts in kind, bench tested 03 under required pressure/vacuum set points at shipyard, all sat.
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
Void 4, Bay 4 from fwd, #1 SSL from deck, V/W, as marked and vertical stiffener.Yes
Resolved DateResolution
Apr 12, 17V/W completed to satisfaction of CG.
5979499 STATEN ISLAND, New York Aug 22, 16 Vessel Inspection - Approved Inspection
5204708 STATEN ISLAND, New York Aug 03, 15 Vessel Inspection - Approved Inspection
4936418 STATEN ISLAND, New York Jul 28, 14 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
ElectricalElectric Generation Source (service)
DescriptionDue DateResolved
Each ungrounded system must be provided with a ground detection system located at the respective switchboard which provides continuous indication of circuit status to ground. Ground detection bulb is out, vessel must repair bulb ensuring there are no grounds on board. (46CFR111.05-25)Aug 12, 14Yes
Resolved DateResolution
Jul 29, 14Vessel repaired fuse associated with ground detection panel. All ground detection indicating bulbs operating as designed.
4744831 WASHINGTON, District of Columbia Oct 22, 13 Incident Investigation - Agency Action Complete
4694003 STATEN ISLAND, New York Aug 21, 13 Vessel Inspection - Agency Action Complete
4677450 STATEN ISLAND, New York Aug 07, 13 Vessel Inspection - Agency Action Complete
  3
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
Cargo Pump Engine #1 and #2 Bellows are not properly secured or clamped down.Aug 21, 13Yes
Resolved DateResolution
Aug 21, 13Vessel properly secured with clamps cargo pump engine #1 and #2 Bellows.
SystemSubsystemCause
ElectricalElectrical Distribution System (service)
DescriptionDue DateResolved
Cargo Pump House #2 located on the cargo block has unapproved electrical outlet and wire connections installed.Aug 21, 13Yes
Resolved DateResolution
Aug 21, 13Witness the installation repair of the marine grade electrical outlet located in the cargo pump house.
SystemSubsystemCause
Deck/CargoVapor Control Systems
DescriptionDue DateResolved
Vapor Recovery System power failure audible/visual alarm (Blue Light) inoperable.Aug 21, 13Yes
Resolved DateResolution
Aug 21, 13Satisfactory tested the vapor recovery system power failure audible/visual alarm.
4513319 NEW HAVEN, Connecticut Jan 09, 13 Vessel Transfer Monitor - Agency Action Complete
4510136 WASHINGTON, District of Columbia Dec 31, 12 Incident Investigation - Agency Action Complete
4403667 STATEN ISLAND, New York Aug 02, 12 Vessel Inspection - Agency Action Complete
4349995 WASHINGTON, District of Columbia May 22, 12 Incident Investigation - Agency Action Complete
4313212 STATEN ISLAND, New York May 16, 12 Vessel Inspection - Approved Inspection
4200479 STATEN ISLAND, New York Dec 02, 11 Vessel Inspection - Agency Action Complete
4118243 STATEN ISLAND, New York Aug 17, 11 Vessel Inspection - Agency Action Complete
3939086 WASHINGTON, District of Columbia Feb 01, 11 Incident Investigation - Agency Action Complete
3928453 STATEN ISLAND, New York Jan 18, 11 Facility Transfer Monitor - Approved Inspection
3848701 STATEN ISLAND, New York Sep 13, 10 Vessel Inspection - Agency Action Complete
  10
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
C/R horizontal support frame IWO #6 side shell transverse frame A/M in #3 stbd double bottom.Oct 13, 10Yes
Resolved DateResolution
Sep 23, 10
SystemSubsystemCause
EngineeringGenerator (propulsion/auxiliary-electric)
DescriptionDue DateResolved
Demonstrate Low Lube oil shutdowns on both generators.Oct 23, 10Yes
Resolved DateResolution
Oct 20, 10
SystemSubsystemCause
ElectricalLighting (service)
DescriptionDue DateResolved
Ground detection system not operational. All 03 lights are out. Repair ground detection system on flood lights panel.Oct 07, 10Yes
Resolved DateResolution
Oct 20, 10
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
Pit found in tank bottom of #3 stbd double bottom, bay 11 on centerline with evidence of leakage of cargo on deck. Prove #3 stbd cargo tank is not leaking prior to conducting cargo operations.Yes
Resolved DateResolution
Sep 13, 10
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
V/W #1 Side shell long IWO #10 side shell transverse frame in #3 port double bottom.Oct 13, 10Yes
Resolved DateResolution
Sep 23, 10
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
V/W #1 side shell long IWO #9 side shell transverse frame in #3 port double bottom.Oct 13, 10Yes
Resolved DateResolution
Sep 23, 10
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
V/W #2 side shell long counting from bottom up IWO of #6 side shell transverse frame in #2 port double bottom.Oct 13, 10Yes
Resolved DateResolution
Sep 23, 10
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
V/W #2 side shell transverse frame IWO #6 side shell long in #4 port double bottom Bay #2.Oct 13, 10Yes
Resolved DateResolution
Sep 23, 10
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
V/W #6 side shell transverse frame IWO #3 side shell long in #3 stbd double bottom.Oct 13, 10Yes
Resolved DateResolution
Sep 23, 10
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
V/W #7 side shell transverse frame A/M IWO #3 side shell long in #3 stbd double bottom.Oct 13, 10Yes
Resolved DateResolution
Sep 23, 10
3688780 NEW HAVEN, Connecticut Mar 02, 10 Vessel Transfer Monitor - Agency Action Complete
3663358 WASHINGTON, District of Columbia Jan 09, 10 Incident Investigation - Agency Action Complete
3656296 WASHINGTON, District of Columbia Dec 23, 09 Incident Investigation - Agency Action Complete
3638141 STATEN ISLAND, New York Nov 23, 09 Vessel Inspection - Agency Action Complete
3622647 NEW HAVEN, Connecticut Oct 26, 09 Vessel Transfer Monitor - Agency Action Complete
3583539 WASHINGTON, District of Columbia Aug 26, 09 Incident Investigation - Agency Action Complete
3442737 STATEN ISLAND, New York Mar 30, 09 Vessel Inspection - Administrative Action
3321547 STATEN ISLAND, New York Sep 10, 08 Vessel Inspection - Agency Action Complete
3029725 Morgan City, Louisiana Aug 16, 07 Vessel Inspection - Approved Inspection
Documents Issued Expires Agency
Cargo Authority Attachment September 25,2008 USCGNY
CERTIFICATE OF DOCUMENTATION September 23,2021 October 31,2022 USCG
Certificate of Inspection September 14,2012 September 14,2017 N/A
Certificate of Inspection - Amended September 14,2012 September 14,2017 N/A
Classification Document July 15,2013 September 13,2018 N/A