IMO/VIN
Callsign
Flag
Service
Year
1200667
WCX3683
UNITED STATES
Tank Barge
2007
Activity#
Port
Date
Activity - Description
Deficiencies
7448576
STATEN ISLAND, New York
May 11, 22
Vessel Inspection - Approved Inspection
7218461
STATEN ISLAND, New York
Jun 07, 21
Vessel Inspection - Approved Inspection
6937881
STATEN ISLAND, New York
Apr 10, 20
Vessel Inspection - Approved Inspection
6709993
STATEN ISLAND, New York
Jun 10, 19
Vessel Inspection - Approved Inspection
6
0
System Subsystem Cause 11 - Life Saving Appliances N/A - No Subsystem
Description Due Date Resolved Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use.
The lifebuoys on the starboard bow and port quarter are not serviceable. The grab lines, retro and plugs are deteriorated. Yes
Resolved Date Resolution Jun 12, 19 Installed new life rings.
System Subsystem Cause 11 - Life Saving Appliances N/A - No Subsystem
Description Due Date Resolved Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use.
The lights attached to the life jackets are inop. Yes
Resolved Date Resolution Jun 12, 19 Installed new lights on the lifejackets.
System Subsystem Cause 11 - Life Saving Appliances N/A - No Subsystem
Description Due Date Resolved Liferafts must be readily transferable for launching on either side of the vessel or supplemented with additional liferafts to bring the total capacity of the liferafts available on each side of the vessel to at least 100% of the total persons on board.
Only one liferaft was installed on top of the accommodation space preventing side to side transfer. Jun 24, 19 Yes
Resolved Date Resolution Oct 17, 19 See Notes for agreed upon conditions. Liferaft to be relocated to suitable position at next drydock.
System Subsystem Cause 06 - Cargo Operations Including Equipment N/A - No Subsystem
Description Due Date Resolved On all tank vessels, where cargo pump shafts pierce gas tight bulkheads, stuffing boxes with readily accessible gas tight glands shall be provided.
The starboard bellows that pierces the bulkhead between the starboard cargo pump prime mover and the starboard cargo pump is not gas tight.
Rectify deficiency prior to operation of the starboard cargo pump. Jun 24, 19 Yes
Resolved Date Resolution Jun 12, 19 Installed new bellows creating vapor tight seal.
System Subsystem Cause 99 - Other N/A - No Subsystem
Description Due Date Resolved When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by the EPA, the operator must secure each type I, II, or II device in a manner which prevents discharge of treated or untreated sewage.
Please provide approval documentation for the type MSD installed on the vessel. No documentation was provided at the time of inspection. No locking device was visible at time of inspection. Yes
Resolved Date Resolution Jun 12, 19 Provided proof of approved Type II MSD.
System Subsystem Cause 09 - Working and Living Conditions 091 - Living Conditions
Description Due Date Resolved Where the plans and arrangements will possibly permit, all passageways leading to living quarters, shall be provided with not less than two means of escape.
The emergency escape hatch from the accommodation space was inoperable. Yes
Resolved Date Resolution Jun 12, 19 Emergency escape hatch has been serviced and is fully operational.
6443862
STATEN ISLAND, New York
Jun 14, 18
Vessel Inspection - Approved Inspection
6220711
STATEN ISLAND, New York
Jul 25, 17
Vessel Inspection - Agency Action Complete
1
0
System Subsystem Cause Pollution Prevention/Response Prevention Equipment Improper/Lack of Maintenance
Description Due Date Resolved Loss of power alarm on overfill protection is inoperable. To be corrected prior to cargo operations. Yes
Resolved Date Resolution Jul 31, 17 Loss of power alarm is now operating correctly.
6109420
Woods Hole, Massachusetts
Apr 05, 17
Vessel Inspection - Approved Inspection
5
0
System Subsystem Cause Construction/Loadline Hull
Description Due Date Resolved 3P, SSL#3, Bay 2/3, vee and weld crack in SSL and vertical stiffener. Yes
Resolved Date Resolution Apr 12, 17 V/W to satisfaction of CG.
System Subsystem Cause Construction/Loadline Hull
Description Due Date Resolved 3P, SSL#6, Bay 1/2, vee and weld crack in SSL and vertical stiffener. Yes
Resolved Date Resolution Apr 12, 17 V/W completed to satisifaction of CG.
System Subsystem Cause Construction/Loadline Hull
Description Due Date Resolved 5P, Bay 5 from ffwd, 1 from top, C/R SSV C channel as marked. Yes
Resolved Date Resolution Apr 12, 17 C/R to original, all sat by CG.
System Subsystem Cause Deck/Cargo Holds/Tanks
Description Due Date Resolved Replace 03 P/V valves in kind (Set points: 2.0 PSI Pressure, .5PSI Vacuum. Failed initial testing. Yes
Resolved Date Resolution Apr 25, 17 Vessel obtained replacement parts in kind, bench tested 03 under required pressure/vacuum set points at shipyard, all sat.
System Subsystem Cause Construction/Loadline Hull
Description Due Date Resolved Void 4, Bay 4 from fwd, #1 SSL from deck, V/W, as marked and vertical stiffener. Yes
Resolved Date Resolution Apr 12, 17 V/W completed to satisfaction of CG.
5979499
STATEN ISLAND, New York
Aug 22, 16
Vessel Inspection - Approved Inspection
5204708
STATEN ISLAND, New York
Aug 03, 15
Vessel Inspection - Approved Inspection
4936418
STATEN ISLAND, New York
Jul 28, 14
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Electrical Electric Generation Source (service)
Description Due Date Resolved Each ungrounded system must be provided with a ground detection system located at the respective switchboard which provides continuous indication of circuit status to ground. Ground detection bulb is out, vessel must repair bulb ensuring there are no grounds on board. (46CFR111.05-25) Aug 12, 14 Yes
Resolved Date Resolution Jul 29, 14 Vessel repaired fuse associated with ground detection panel. All ground detection indicating bulbs operating as designed.
4744831
WASHINGTON, District of Columbia
Oct 22, 13
Incident Investigation - Agency Action Complete
4694003
STATEN ISLAND, New York
Aug 21, 13
Vessel Inspection - Agency Action Complete
4677450
STATEN ISLAND, New York
Aug 07, 13
Vessel Inspection - Agency Action Complete
3
0
System Subsystem Cause Deck/Cargo Cargo Transfer/Lightering (liquid)
Description Due Date Resolved Cargo Pump Engine #1 and #2 Bellows are not properly secured or clamped down. Aug 21, 13 Yes
Resolved Date Resolution Aug 21, 13 Vessel properly secured with clamps cargo pump engine #1 and #2 Bellows.
System Subsystem Cause Electrical Electrical Distribution System (service)
Description Due Date Resolved Cargo Pump House #2 located on the cargo block has unapproved electrical outlet and wire connections installed. Aug 21, 13 Yes
Resolved Date Resolution Aug 21, 13 Witness the installation repair of the marine grade electrical outlet located in the cargo pump house.
System Subsystem Cause Deck/Cargo Vapor Control Systems
Description Due Date Resolved Vapor Recovery System power failure audible/visual alarm (Blue Light) inoperable. Aug 21, 13 Yes
Resolved Date Resolution Aug 21, 13 Satisfactory tested the vapor recovery system power failure audible/visual alarm.
4513319
NEW HAVEN, Connecticut
Jan 09, 13
Vessel Transfer Monitor - Agency Action Complete
4510136
WASHINGTON, District of Columbia
Dec 31, 12
Incident Investigation - Agency Action Complete
4403667
STATEN ISLAND, New York
Aug 02, 12
Vessel Inspection - Agency Action Complete
4349995
WASHINGTON, District of Columbia
May 22, 12
Incident Investigation - Agency Action Complete
4313212
STATEN ISLAND, New York
May 16, 12
Vessel Inspection - Approved Inspection
4200479
STATEN ISLAND, New York
Dec 02, 11
Vessel Inspection - Agency Action Complete
4118243
STATEN ISLAND, New York
Aug 17, 11
Vessel Inspection - Agency Action Complete
3939086
WASHINGTON, District of Columbia
Feb 01, 11
Incident Investigation - Agency Action Complete
3928453
STATEN ISLAND, New York
Jan 18, 11
Facility Transfer Monitor - Approved Inspection
3848701
STATEN ISLAND, New York
Sep 13, 10
Vessel Inspection - Agency Action Complete
10
0
System Subsystem Cause Construction/Loadline Hull
Description Due Date Resolved C/R horizontal support frame IWO #6 side shell transverse frame A/M in #3 stbd double bottom. Oct 13, 10 Yes
Resolved Date Resolution Sep 23, 10
System Subsystem Cause Engineering Generator (propulsion/auxiliary-electric)
Description Due Date Resolved Demonstrate Low Lube oil shutdowns on both generators. Oct 23, 10 Yes
Resolved Date Resolution Oct 20, 10
System Subsystem Cause Electrical Lighting (service)
Description Due Date Resolved Ground detection system not operational. All 03 lights are out. Repair ground detection system on flood lights panel. Oct 07, 10 Yes
Resolved Date Resolution Oct 20, 10
System Subsystem Cause Construction/Loadline Hull
Description Due Date Resolved Pit found in tank bottom of #3 stbd double bottom, bay 11 on centerline with evidence of leakage of cargo on deck. Prove #3 stbd cargo tank is not leaking prior to conducting cargo operations. Yes
Resolved Date Resolution Sep 13, 10
System Subsystem Cause Construction/Loadline Hull
Description Due Date Resolved V/W #1 Side shell long IWO #10 side shell transverse frame in #3 port double bottom. Oct 13, 10 Yes
Resolved Date Resolution Sep 23, 10
System Subsystem Cause Construction/Loadline Hull
Description Due Date Resolved V/W #1 side shell long IWO #9 side shell transverse frame in #3 port double bottom. Oct 13, 10 Yes
Resolved Date Resolution Sep 23, 10
System Subsystem Cause Construction/Loadline Hull
Description Due Date Resolved V/W #2 side shell long counting from bottom up IWO of #6 side shell transverse frame in #2 port double bottom. Oct 13, 10 Yes
Resolved Date Resolution Sep 23, 10
System Subsystem Cause Construction/Loadline Hull
Description Due Date Resolved V/W #2 side shell transverse frame IWO #6 side shell long in #4 port double bottom Bay #2. Oct 13, 10 Yes
Resolved Date Resolution Sep 23, 10
System Subsystem Cause Construction/Loadline Hull
Description Due Date Resolved V/W #6 side shell transverse frame IWO #3 side shell long in #3 stbd double bottom. Oct 13, 10 Yes
Resolved Date Resolution Sep 23, 10
System Subsystem Cause Construction/Loadline Hull
Description Due Date Resolved V/W #7 side shell transverse frame A/M IWO #3 side shell long in #3 stbd double bottom. Oct 13, 10 Yes
Resolved Date Resolution Sep 23, 10
3688780
NEW HAVEN, Connecticut
Mar 02, 10
Vessel Transfer Monitor - Agency Action Complete
3663358
WASHINGTON, District of Columbia
Jan 09, 10
Incident Investigation - Agency Action Complete
3656296
WASHINGTON, District of Columbia
Dec 23, 09
Incident Investigation - Agency Action Complete
3638141
STATEN ISLAND, New York
Nov 23, 09
Vessel Inspection - Agency Action Complete
3622647
NEW HAVEN, Connecticut
Oct 26, 09
Vessel Transfer Monitor - Agency Action Complete
3583539
WASHINGTON, District of Columbia
Aug 26, 09
Incident Investigation - Agency Action Complete
3442737
STATEN ISLAND, New York
Mar 30, 09
Vessel Inspection - Administrative Action
3321547
STATEN ISLAND, New York
Sep 10, 08
Vessel Inspection - Agency Action Complete
3029725
Morgan City, Louisiana
Aug 16, 07
Vessel Inspection - Approved Inspection
Documents
Issued
Expires
Agency
Cargo Authority Attachment
September 25,2008
USCGNY
CERTIFICATE OF DOCUMENTATION
September 23,2021
October 31,2022
USCG
Certificate of Inspection
September 14,2012
September 14,2017
N/A
Certificate of Inspection - Amended
September 14,2012
September 14,2017
N/A
Classification Document
July 15,2013
September 13,2018
N/A