Fred E Adams
Print Q88   
IMO/VIN Callsign Flag Service Year
571318 WDG9611 UNITED STATES Towing Vessel 1976
Activity# Port Date Activity - Description Deficiencies
7396705 WASHINGTON, District of Columbia Feb 06, 22 Incident Investigation - Agency Action Complete
7141404 Jacksonville, Florida Feb 25, 21 Vessel Inspection - Agency Action Complete
  4
SystemSubsystemCause
13 - Propulsion and Auxiliary MachineryN/A - No Subsystem
DescriptionDue DateResolved
50c - Each towing vessel must have reliable means to provide notification. Vessel does not have low hydraulic steering fluid level indicator. 46 CFR 143.230(a)(6)Mar 26, 21Yes
Resolved DateResolution
Mar 18, 21Vessel installed alarm Tested Sat
SystemSubsystemCause
09 - Working and Living Conditions092 - Working Conditions
DescriptionDue DateResolved
50c - Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Engine room overhead light not within proper specifications. 46 CFR 143.400(a)Mar 26, 21Yes
Resolved DateResolution
Mar 15, 21Engine room light corrected.
SystemSubsystemCause
07 - Fire SafetyN/A - No Subsystem
DescriptionDue DateResolved
50c - Means must be provided for stopping each fan in a ventilation system serving machinery spaces and for closing, in case of fire, each doorway, ventilator, and annular space around funnels and other openings into such space. Stove hood fan exhaust leads to enginroom with no means to close. 46 CFR 144.605Mar 26, 21Yes
Resolved DateResolution
Mar 15, 21Exhaust vent sealed.
SystemSubsystemCause
03 - Water/Weathertight ConditionsN/A - No Subsystem
DescriptionDue DateResolved
50c - Windows and other openings at the operating station must be of sufficient size and properly located to provide a clear field of vision for safe operation. the forward port side window of the pilot house cracked. 46 CFR 144.905(a)Mar 26, 21Yes
Resolved DateResolution
Mar 18, 21Vessel Replaced window
6318759 Savannah, Georgia Dec 12, 17 Uninspected Towing Vessel Exam - Approved Inspection
5021130 Savannah, Georgia Nov 10, 14 Uninspected Towing Vessel Exam - Approved Inspection
4193788 Savannah, Georgia Nov 22, 11 Uninspected Towing Vessel Exam - Approved Inspection
2448889 Washington, District of Columbia Aug 02, 05 Vessel Inspection - Security Plan Approved by MSC
2215983 North Charleston, South Carolina Oct 07, 04 Enforcement - Agency Action Complete
2215786 North Charleston, South Carolina Oct 07, 04 Enforcement - Agency Action Complete
2215080 North Charleston, South Carolina Oct 05, 04 Vessel Inspection - Agency Action Complete
2214647 North Charleston, South Carolina Oct 05, 04 Vessel Transfer Monitor - Approved Inspection
1970614 Washington, District of Columbia Dec 16, 03 Vessel Inspection - Security Plan Approved by MSC
808408 Savannah, Georgia Dec 07, 98 Vessel Inspection - Agency Action Complete
803357 Savannah, Georgia Nov 04, 98 Vessel Inspection - Agency Action Complete
  3
SystemSubsystemCause
EngineeringUnknown
DescriptionDue DateResolved
Provide flame screens for fuel vents. Nov 04, 98Yes
Resolved DateResolution
Nov 04, 98
SystemSubsystemCause
LifesavingUnknown
DescriptionDue DateResolved
Provide retro tape on all of the vessels life rings. Nov 04, 98Yes
Resolved DateResolution
Nov 04, 98
SystemSubsystemCause
LifesavingUnknown
DescriptionDue DateResolved
Provide the name of the vessel or crewmember's name on the work vest and all type I life jackets. Nov 04, 98Yes
Resolved DateResolution
Nov 04, 98
12628 WASHINGTON, District of Columbia Mar 31, 94 Incident Investigation - Agency Action Complete
34704 WASHINGTON, District of Columbia Jan 06, 93 Incident Investigation - Agency Action Complete
Documents Issued Expires Agency
CERTIFICATE OF DOCUMENTATION October 6,2021 October 31,2022 USCG
Certificate of Inspection February 24,2021 February 24,2026 USCG