IMO/VIN
Callsign
Flag
Service
Year
1210060
WDE4883
UNITED STATES
Tank Barge
2008
Activity#
Port
Date
Activity - Description
Deficiencies
7479200
STATEN ISLAND, New York
Jun 16, 22
Vessel Inspection - Agency Action Complete
7199883
STATEN ISLAND, New York
May 18, 21
Vessel Inspection - Agency Action Complete
1
0
System Subsystem Cause 01 - Certificates & Documentation 011 - Ships Certificates
Description Due Date Resolved Vessel has an invalid COI.
Certificates of Inspection will be issued for a period of 5 years; COI expires on 23APR2023. Vessel missed annual, DDX, ISE and PV exam.
Complete COI Inspection prior to conducting cargo operations. Sep 18, 24 Yes
Resolved Date Resolution Jun 23, 22 COI has been deactivated.
7138785
STATEN ISLAND, New York
Feb 16, 21
Vessel Inspection - Agency Action Complete
7105112
STATEN ISLAND, New York
Dec 02, 20
Vessel Inspection - Agency Action Complete
7026686
STATEN ISLAND, New York
Aug 07, 20
Vessel Inspection - Agency Action Complete
7020455
STATEN ISLAND, New York
Jul 31, 20
Vessel Inspection - Agency Action Complete
6750824
PHILADELPHIA, Pennsylvania
Jul 15, 19
Vessel Inspection - Approved Inspection
3
0
System Subsystem Cause 09 - Working and Living Conditions 091 - Living Conditions
Description Due Date Resolved Bergen tank level monitoring system in ship's office has an inverter fault and is improperly connected. Make repairs and prove to the satisfaction of attending CG marine inspector. Aug 05, 19 Yes
Resolved Date Resolution Aug 09, 19 Verified electrician made repairs.
System Subsystem Cause 10 - Safety of Navigation N/A - No Subsystem
Description Due Date Resolved Port navigation running light is not working properly. Make repairs and prove proper operation to attending CG marine inspector. Aug 05, 19 Yes
Resolved Date Resolution Aug 09, 19 Verified operation of port navigation light.
System Subsystem Cause 09 - Working and Living Conditions 092 - Working Conditions
Description Due Date Resolved Relief valves for the pressure vessel and #2 air compressor are not operating properly. Repair or replace and prove to the satisfaction of the attending CG marine inspector prior to operating cargo pumps. Yes
Resolved Date Resolution Jul 26, 19 A new relief valve was installed.
6649228
STATEN ISLAND, New York
Mar 26, 19
Vessel Inspection - Approved Inspection
6488239
STATEN ISLAND, New York
Jul 23, 18
Vessel Inspection - Approved Inspection
6467911
STATEN ISLAND, New York
Jul 05, 18
Vessel Inspection - Approved Inspection
6342595
STATEN ISLAND, New York
Jan 24, 18
Vessel Inspection - Agency Action Complete
2
0
System Subsystem Cause Construction/Loadline Markings
Description Due Date Resolved Fresh water mark on load line is not permanently marked. Jan 31, 18 Yes
Resolved Date Resolution Jan 30, 18 Mark was punched and repainted
System Subsystem Cause Construction/Loadline Penetrations
Description Due Date Resolved Gasket on #4S Void aft hatch is not continuous Jan 31, 18 Yes
Resolved Date Resolution Jan 30, 18 Gasket was replaced with new.
6323605
STATEN ISLAND, New York
Dec 13, 17
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Operations/Management Drug and Alcohol Testing
Description Due Date Resolved Vessel did not have current drug and alcohol enrollment certificate. Dec 20, 17 Yes
Resolved Date Resolution Dec 14, 17 Recieved copy of the certificate. Certificate was at the company's office, and never made it onboard. Def cleared.
6072567
STATEN ISLAND, New York
Jan 18, 17
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Documentation Certificates/Documents Improper/Lack of Maintenance
Description Due Date Resolved Any vessel of at least five net tons which engages in the fisheries on the navigable waters of the United States or in the Exclusive Economic Zone, or coastwise trade, unless exempt under §67.9(c), must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. The original COD was not onboard the vessel. 46 CFR 67.7 Yes
Resolved Date Resolution Jan 23, 17 Received and accepted certified copy of COD.
5851191
STATEN ISLAND, New York
Apr 11, 16
Vessel Inspection - Approved Inspection
5232928
Coram, New York
Sep 01, 15
Vessel Transfer Monitor - Approved Inspection
5089828
STATEN ISLAND, New York
Mar 24, 15
Vessel Inspection - Approved Inspection
3
0
System Subsystem Cause Deck/Cargo Cargo Transfer/Lightering (liquid) Improper Installation
Description Due Date Resolved A pressure gauge shall be installed for each pump discharge, and it shall be located at a point visible with respect to the pump controls. The cargo pump gauge cannot be seen from the operating station. Due prior to next credit drydock in 2018. Mar 18, 18 Yes
Resolved Date Resolution Apr 21, 15 Verified that the cargo pump gauges are now visible from the operating station.
System Subsystem Cause Construction/Loadline Markings Improper Installation
Description Due Date Resolved The International Load Line Certificate shall not be issued to the ship until the surveyor has certified the marks are correctly and permanently indicated on the ship's sides. The load line on the ship's hull does not match the Load Line Certificate. Apr 15, 15 Yes
Resolved Date Resolution Apr 02, 15 Vessel has fixed their load line on the hull. It now properly reflects what is listed on the certificate.
System Subsystem Cause Electrical Electrical Distribution System (service) Improper Installation
Description Due Date Resolved There must be ground detection for each power distribution system that is isolated from the ship's service power system by transformers, motor generator sets, or other devices. The vessel has the wrong ground detection system installed on the 120V system. Apr 22, 15 Yes
Resolved Date Resolution Mar 30, 15 Received technician report from General Marine Electric stating the correct 120v ground detection has been installed.
4886698
PHILADELPHIA, Pennsylvania
Jun 13, 14
Vessel Inspection - Approved Inspection
4612174
PHILADELPHIA, Pennsylvania
Jun 05, 13
Facility Transfer Monitor - Agency Action Complete
4547429
STATEN ISLAND, New York
Mar 15, 13
Vessel Inspection - Agency Action Complete
5
0
System Subsystem Cause Electrical Electric Generation Source (service)
Description Due Date Resolved Install mechanical interlock to prevent generators #1 and #2 from simultaneous operations. Apr 29, 13 Yes
Resolved Date Resolution Mar 29, 13
System Subsystem Cause Communications Radio Communications
Description Due Date Resolved Must install appropriate EPIRB battery and provide proof of monthly test. Apr 04, 13 Yes
Resolved Date Resolution Mar 29, 13
System Subsystem Cause Documentation Certificates/Documents
Description Due Date Resolved Provide SEEMP for IAPP Renewal in accordance with MARPOL Annex VI Ch. 4 Reg. 22. Apr 29, 13 Yes
Resolved Date Resolution Apr 25, 13
System Subsystem Cause Documentation Certificates/Documents
Description Due Date Resolved Provide Volatile Organic Compound (VOC) Management Plan in accordance with MARPOL Annex VI Reg. 15.6. Apr 29, 13 Yes
Resolved Date Resolution Apr 25, 13
System Subsystem Cause Operations/Management Cargo Transfer/Lightering
Description Due Date Resolved Vessel transfer procedures must be updated to include table or graph showing the liquid transfer rate versus the pressure drop as per MSC letter C1-1204938. Yes
Resolved Date Resolution Mar 28, 13 Received documentation prior to departing the vessel.
4509511
WASHINGTON, District of Columbia
Dec 29, 12
Incident Investigation - Agency Action Complete
4495184
STATEN ISLAND, New York
Dec 03, 12
Vessel Inspection - Agency Action Complete
4486839
WASHINGTON, District of Columbia
Nov 16, 12
Incident Investigation - Agency Action Complete
4420677
STATEN ISLAND, New York
Aug 24, 12
Vessel Inspection - Agency Action Complete
1
0
System Subsystem Cause Electrical Electric Generation Source (service)
Description Due Date Resolved Both gen sets are oil covered at the front end including the cooling fan; must clean and remove all oil residue to prevent possible pollution and fire hazard. Sep 07, 12 Yes
Resolved Date Resolution Sep 07, 12 Cleaned Gen sets and submitted picture
4224227
WASHINGTON, District of Columbia
Jan 11, 12
Incident Investigation - Agency Action Complete
4169544
WASHINGTON, District of Columbia
Oct 15, 11
Incident Investigation - Agency Action Complete
4064210
STATEN ISLAND, New York
Jul 01, 11
Vessel Inspection - Agency Action Complete
4052291
STATEN ISLAND, New York
Jun 21, 11
Vessel Inspection - Approved Inspection
4022171
STATEN ISLAND, New York
May 25, 11
Vessel Inspection - Agency Action Complete
3800951
STATEN ISLAND, New York
Jul 20, 10
Vessel Inspection - Agency Action Complete
3609886
STATEN ISLAND, New York
Oct 06, 09
Vessel Inspection - Agency Action Complete
3504741
STATEN ISLAND, New York
Jun 17, 09
Vessel Inspection - Agency Action Complete
1
0
System Subsystem Cause Documentation Certificates/Documents
Description Due Date Resolved Vsl needs to prove full compliance to MARPOL Annex VI regulations to the satisfaction of the attending MI. Vsl is limited to domestic voyages only until compliance is proven. Yes
Resolved Date Resolution Jul 31, 09 Received documentation to fulfill requirements of the 835 issued. Deficiency cleared.
3090552
New Orleans, Louisiana
Oct 31, 07
Vessel Inspection - Approved Inspection
Documents
Issued
Expires
Agency
Cargo Authority Attachment
December 4,2012
N/A
CERTIFICATE OF DOCUMENTATION
August 23,2021
August 31,2022
USCG
Certificate of Inspection
March 28,2013
March 28,2018
N/A
Certificate of Inspection - Amended
March 28,2013
March 28,2018
N/A
Classification Document
May 23,2013
July 1,2018
ABS
International Load Line Certificate
April 2,2013
July 1,2018
ABS
International Oil Pollution Prevention Certificate
March 28,2013
March 28,2018
N/A
ISM - Document Of Compliance
September 4,2012
September 18,2017
ABS
ISM - Safety Management Certificate
October 21,2013
October 29,2018
ABS
Tonnage Certificate, International
June 4,2008
N/A
Tonnage Certificate, U.S.
June 4,2008
ABS