IMO/VIN
Callsign
Flag
Service
Year
9542984
9V6251
SINGAPORE
Tank Ship
2013
Activity#
Port
Date
Activity - Description
Deficiencies
7143102
Port Arthur, Texas
Feb 18, 21
Vessel Inspection - Approved Inspection
7140420
Houston, Texas
Feb 14, 21
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause 06 - Cargo Operations Including Equipment N/A - No Subsystem Improper Installation
Description Due Date Resolved THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHOULD BE MAINTAINED TO CONFROM WITH THE PROVISIONS OF THE CODE TO ENSURE THAT THE SHIP WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. AFTER THE VESSEL REPLACED GAS DETECTION SENSORS, NEW PROCEDTURES FOR THE ELECTRO-CHEMICAL SENSORS WERE NOT ADDED TO THE OPERATIONS MANUAL. DURING THE INSPECTION SHIPS CREW WERE NOT ABLE TO CALIBRATE THE EQUIPMENT FOLLOWING THEIR ESTABLISHED PROCEDURES. 74 SOLAS (14) VII/13.1; IGC CODE 1.5.3.1 10c Feb 18, 21 Yes
Resolved Date Resolution Feb 18, 21 DEFICIENCY RECTIFIED ON THE SPOT
6101311
Houston, Texas
Mar 16, 17
Vessel Inspection - Approved Inspection
3
0
System Subsystem Cause Fire Fighting Fixed Pressure Water-Spraying Fire Extinguishing System Improper/Lack of Maintenance
Description Due Date Resolved 1850-Fire Protection Cargo Deck Area- On ships carrying flammable or toxic products or both, a water-spray system for cooling fire prevention and crew protection should be installed. Upon operating the deck water-spray system, discovered 50% of the nozzles ovethe port & starboard manifolds, all nozzles forward of the #2 cargo tank and over the vaporizer did not function. IGC 11.3.1 Yes
Resolved Date Resolution Mar 21, 17 PSCO witnessed proper pressure test of the deck water spray system. Dedicated water spray pump remains inoperative.
System Subsystem Cause Operations/Management Vessel Safety Management
Description Due Date Resolved 2515-Company responsibility and authority-The company should ensure inspections are held at appropriate intervals, any non-conformity is reported, appropriate corrective action is taken and records of these activities. Could not provided guidlines on testing and record retention of deck water spray system. ISM CODE 10 Yes
Resolved Date Resolution Mar 21, 17 Received class report attesting documenting ISM Audit
System Subsystem Cause Fire Fighting Fixed Pressure Water-Spraying Fire Extinguishing System Improper/Lack of Maintenance
Description Due Date Resolved On ships carrying flammable or toxic products or both a water spray system for cooling, fire prevention and crew protection should be installed. Port State Control officers found the deck water spray pump inoperable when tested. 74SOLAS(14) VII/13.1 ICG 11.3.1 Yes
Resolved Date Resolution Mar 21, 17 Vessel is able to charge 2 fire hoses and deck water spray with 5 bar pressure to clear open deficiency. Vessel to effectuate permanent repairs to deck water spray pump.
6223795
Port Arthur, Texas
Mar 16, 17
Vessel Inspection - Approved Inspection
Documents
Issued
Expires
Agency
Certificate of Fitness - Gas Carrier
September 13,2016
June 26,2018
BV
Classification Document
September 30,2019
June 26,2023
DNV
International Certificate of Fitness - Gas Carrier
August 21,2019
June 26,2023
DNV
International Load Line Certificate
August 21,2019
June 26,2023
DNV
International Oil Pollution Prevention Certificate
February 17,2017
March 27,2017
BV
ISM - Document Of Compliance
May 20,2016
May 9,2021
BV
ISM - Safety Management Certificate
November 1,2016
October 10,2021
BV
Minimum Safe Manning Document
May 7,2016
June 28,2018
MT
NLS Certificate
September 13,2016
June 26,2018
BV
SOLAS Cargo Ship Safety Certificate
November 1,2016
October 10,2021
BV
SOLAS Cargo Ship Safety Construction Certificate
August 21,2019
June 26,2023
DNV
SOLAS Cargo Ship Safety Equipment Certificate
August 21,2019
June 26,2023
DNV
SOLAS Cargo Ship Safety Radio Certificate
August 21,2019
June 26,2023
DNV
Subchapter O Endorsement
April 5,2016
N/A
Tonnage Certificate, International
September 24,2019
DNV