Thalea Schulte
Print Q88   
IMO/VIN Callsign Flag Service Year
9542984 9V6251 SINGAPORE Tank Ship 2013
Activity# Port Date Activity - Description Deficiencies
7143102 Port Arthur, Texas Feb 18, 21 Vessel Inspection - Approved Inspection
7140420 Houston, Texas Feb 14, 21 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No SubsystemImproper Installation
DescriptionDue DateResolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHOULD BE MAINTAINED TO CONFROM WITH THE PROVISIONS OF THE CODE TO ENSURE THAT THE SHIP WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. AFTER THE VESSEL REPLACED GAS DETECTION SENSORS, NEW PROCEDTURES FOR THE ELECTRO-CHEMICAL SENSORS WERE NOT ADDED TO THE OPERATIONS MANUAL. DURING THE INSPECTION SHIPS CREW WERE NOT ABLE TO CALIBRATE THE EQUIPMENT FOLLOWING THEIR ESTABLISHED PROCEDURES. 74 SOLAS (14) VII/13.1; IGC CODE 1.5.3.1 10cFeb 18, 21Yes
Resolved DateResolution
Feb 18, 21DEFICIENCY RECTIFIED ON THE SPOT
6101311 Houston, Texas Mar 16, 17 Vessel Inspection - Approved Inspection
  3
SystemSubsystemCause
Fire FightingFixed Pressure Water-Spraying Fire Extinguishing SystemImproper/Lack of Maintenance
DescriptionDue DateResolved
1850-Fire Protection Cargo Deck Area- On ships carrying flammable or toxic products or both, a water-spray system for cooling fire prevention and crew protection should be installed. Upon operating the deck water-spray system, discovered 50% of the nozzles ovethe port & starboard manifolds, all nozzles forward of the #2 cargo tank and over the vaporizer did not function. IGC 11.3.1Yes
Resolved DateResolution
Mar 21, 17PSCO witnessed proper pressure test of the deck water spray system. Dedicated water spray pump remains inoperative.
SystemSubsystemCause
Operations/ManagementVessel Safety Management
DescriptionDue DateResolved
2515-Company responsibility and authority-The company should ensure inspections are held at appropriate intervals, any non-conformity is reported, appropriate corrective action is taken and records of these activities. Could not provided guidlines on testing and record retention of deck water spray system. ISM CODE 10Yes
Resolved DateResolution
Mar 21, 17Received class report attesting documenting ISM Audit
SystemSubsystemCause
Fire FightingFixed Pressure Water-Spraying Fire Extinguishing SystemImproper/Lack of Maintenance
DescriptionDue DateResolved
On ships carrying flammable or toxic products or both a water spray system for cooling, fire prevention and crew protection should be installed. Port State Control officers found the deck water spray pump inoperable when tested. 74SOLAS(14) VII/13.1 ICG 11.3.1Yes
Resolved DateResolution
Mar 21, 17Vessel is able to charge 2 fire hoses and deck water spray with 5 bar pressure to clear open deficiency. Vessel to effectuate permanent repairs to deck water spray pump.
6223795 Port Arthur, Texas Mar 16, 17 Vessel Inspection - Approved Inspection
Documents Issued Expires Agency
Certificate of Fitness - Gas Carrier September 13,2016 June 26,2018 BV
Classification Document September 30,2019 June 26,2023 DNV
International Certificate of Fitness - Gas Carrier August 21,2019 June 26,2023 DNV
International Load Line Certificate August 21,2019 June 26,2023 DNV
International Oil Pollution Prevention Certificate February 17,2017 March 27,2017 BV
ISM - Document Of Compliance May 20,2016 May 9,2021 BV
ISM - Safety Management Certificate November 1,2016 October 10,2021 BV
Minimum Safe Manning Document May 7,2016 June 28,2018 MT
NLS Certificate September 13,2016 June 26,2018 BV
SOLAS Cargo Ship Safety Certificate November 1,2016 October 10,2021 BV
SOLAS Cargo Ship Safety Construction Certificate August 21,2019 June 26,2023 DNV
SOLAS Cargo Ship Safety Equipment Certificate August 21,2019 June 26,2023 DNV
SOLAS Cargo Ship Safety Radio Certificate August 21,2019 June 26,2023 DNV
Subchapter O Endorsement April 5,2016 N/A
Tonnage Certificate, International September 24,2019 DNV