Nordic Vega
Print Q88   
IMO/VIN Callsign Flag Service Year
9412581 C6XZ5 BAHAMAS, THE Tank Ship 2010
Activity# Port Date Activity - Description Deficiencies
7193413 New Orleans, Louisiana May 17, 21 Vessel Inspection - Approved Inspection
6768320 STATEN ISLAND, New York Jul 31, 19 Vessel Inspection - Approved Inspection
6260910 Lewes, Delaware Aug 24, 17 Vessel Inspection - Approved Inspection
6232991 Lewes, Delaware Aug 15, 17 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
DocumentationCertificates/DocumentsInvalid
DescriptionDue DateResolved
A discrepancy was found on the IOPP Form B with regards to the ballast water capacity. The calculated total was 630 cubic meters different than what was indicated on the form.Yes
Resolved DateResolution
Aug 24, 17Upon further review of the Ballast Water Capacity, it was found that the total numbers did add up, making the document correct.
6236827 PHILADELPHIA, Pennsylvania Aug 11, 17 Vessel Operational Control - Agency Action Complete
6033876 New Orleans, Louisiana Nov 04, 16 Vessel Inspection - Approved Inspection
5940965 Morgan City, Louisiana Jul 16, 16 Vessel Inspection - Approved Inspection
4898068 Morgan City, Louisiana Jun 25, 14 Vessel Inspection - Approved Inspection
4736412 New Orleans, Louisiana Oct 17, 13 Vessel Inspection - Administrative Action
4596624 New Orleans, Louisiana May 22, 13 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Deck/CargoCrude Oil Washing Systems
DescriptionDue DateResolved
1770- SBT, CBT, COW- Effectiveness of vessel's COW system has not been reviewed. MARPOL 73/78 Annex I/33May 29, 13Yes
Resolved DateResolution
Oct 17, 13RECEIVED CLASS REPORT FROM VESSEL
4411554 Lewes, Delaware Aug 16, 12 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
Any ship of 10,000 gross tonnage and above shall be fitted with oil filtering equipment. Oil filtering equipment will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15 ppm. Ships oil filtering equipments 15 ppm sensor is broken and inop.Yes
Resolved DateResolution
Aug 20, 12Vessel provided a class report attesting to the repairs and operation of the 15 ppm oil filtering equipment. This satisfies the requirements laid out by the PSCO''s.
4055302 Morgan City, Louisiana Jun 27, 11 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
EngineeringGenerator (propulsion/auxiliary-electric)
DescriptionDue DateResolved
0999 - Other (safety in general) - Every steam pipe through which steam will pass shall be designed to withstand the maximum working stressor to whcih it may be subjected. A steam return line above the #2 generator is leaking steam/water. 74 SOLAS (2009 ConsEd) II-1/33.1.Jul 11, 11Yes
Resolved DateResolution
Jul 05, 11Vessel provided photographs as evidence of repair. Deficincy cleared.
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel July 16,2016 July 16,2018 N/A
Classification Document May 3,2019 November 30,2020 DNV
COC-TVE Annual June 25,2014 May 22,2015 N/A
COC-TVE Renewal May 22,2013 May 22,2015 NEWMS
International Load Line Certificate November 29,2020 November 30,2025 DNV
International Oil Pollution Prevention Certificate December 5,2017 November 30,2020 DNV
ISM - Document Of Compliance March 13,2019 March 24,2024 N/A
ISM - Safety Management Certificate April 3,2018 April 10,2023 DNV
Minimum Safe Manning Document May 2,2019 May 1,2024 BS
SOLAS Cargo Ship Safety Construction Certificate November 29,2020 November 30,2025 DNV
SOLAS Cargo Ship Safety Equipment Certificate November 29,2020 November 30,2025 DNV
SOLAS Cargo Ship Safety Radio Certificate May 3,2019 November 30,2020 DNV
Tonnage Certificate, International October 18,2010 DNV