IMO/VIN
Callsign
Flag
Service
Year
9412581
C6XZ5
BAHAMAS, THE
Tank Ship
2010
Activity#
Port
Date
Activity - Description
Deficiencies
7193413
New Orleans, Louisiana
May 17, 21
Vessel Inspection - Approved Inspection
6768320
STATEN ISLAND, New York
Jul 31, 19
Vessel Inspection - Approved Inspection
6260910
Lewes, Delaware
Aug 24, 17
Vessel Inspection - Approved Inspection
6232991
Lewes, Delaware
Aug 15, 17
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Documentation Certificates/Documents Invalid
Description Due Date Resolved A discrepancy was found on the IOPP Form B with regards to the ballast water capacity. The calculated total was 630 cubic meters different than what was indicated on the form. Yes
Resolved Date Resolution Aug 24, 17 Upon further review of the Ballast Water Capacity, it was found that the total numbers did add up, making the document correct.
6236827
PHILADELPHIA, Pennsylvania
Aug 11, 17
Vessel Operational Control - Agency Action Complete
6033876
New Orleans, Louisiana
Nov 04, 16
Vessel Inspection - Approved Inspection
5940965
Morgan City, Louisiana
Jul 16, 16
Vessel Inspection - Approved Inspection
4898068
Morgan City, Louisiana
Jun 25, 14
Vessel Inspection - Approved Inspection
4736412
New Orleans, Louisiana
Oct 17, 13
Vessel Inspection - Administrative Action
4596624
New Orleans, Louisiana
May 22, 13
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Deck/Cargo Crude Oil Washing Systems
Description Due Date Resolved 1770- SBT, CBT, COW- Effectiveness of vessel's COW system has not been reviewed. MARPOL 73/78 Annex I/33 May 29, 13 Yes
Resolved Date Resolution Oct 17, 13 RECEIVED CLASS REPORT FROM VESSEL
4411554
Lewes, Delaware
Aug 16, 12
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Pollution Prevention/Response Prevention Equipment
Description Due Date Resolved Any ship of 10,000 gross tonnage and above shall be fitted with oil filtering equipment. Oil filtering equipment will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15 ppm. Ships oil filtering equipments 15 ppm sensor is broken and inop. Yes
Resolved Date Resolution Aug 20, 12 Vessel provided a class report attesting to the repairs and operation of the 15 ppm oil filtering equipment. This satisfies the requirements laid out by the PSCO''s.
4055302
Morgan City, Louisiana
Jun 27, 11
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Engineering Generator (propulsion/auxiliary-electric)
Description Due Date Resolved 0999 - Other (safety in general) - Every steam pipe through which steam will pass shall be designed to withstand the maximum working stressor to whcih it may be subjected. A steam return line above the #2 generator is leaking steam/water. 74 SOLAS (2009 ConsEd) II-1/33.1. Jul 11, 11 Yes
Resolved Date Resolution Jul 05, 11 Vessel provided photographs as evidence of repair. Deficincy cleared.
Documents
Issued
Expires
Agency
Certificate of Compliance - Tank Vessel
July 16,2016
July 16,2018
N/A
Classification Document
May 3,2019
November 30,2020
DNV
COC-TVE Annual
June 25,2014
May 22,2015
N/A
COC-TVE Renewal
May 22,2013
May 22,2015
NEWMS
International Load Line Certificate
November 29,2020
November 30,2025
DNV
International Oil Pollution Prevention Certificate
December 5,2017
November 30,2020
DNV
ISM - Document Of Compliance
March 13,2019
March 24,2024
N/A
ISM - Safety Management Certificate
April 3,2018
April 10,2023
DNV
Minimum Safe Manning Document
May 2,2019
May 1,2024
BS
SOLAS Cargo Ship Safety Construction Certificate
November 29,2020
November 30,2025
DNV
SOLAS Cargo Ship Safety Equipment Certificate
November 29,2020
November 30,2025
DNV
SOLAS Cargo Ship Safety Radio Certificate
May 3,2019
November 30,2020
DNV
Tonnage Certificate, International
October 18,2010
DNV