IMO/VIN
Callsign
Flag
Service
Year
1235496
WDM9209
UNITED STATES
Tank Barge
2012
Activity#
Port
Date
Activity - Description
Deficiencies
7458088
STATEN ISLAND, New York
May 24, 22
Vessel Inspection - Administrative Action
7393559
STATEN ISLAND, New York
Feb 09, 22
Vessel Inspection - Approved Inspection
7235953
STATEN ISLAND, New York
Jun 25, 21
Vessel Inspection - Agency Action Complete
7129076
STATEN ISLAND, New York
Jan 22, 21
Vessel Inspection - Approved Inspection
7105124
STATEN ISLAND, New York
Dec 03, 20
Vessel Inspection - Approved Inspection
7105136
STATEN ISLAND, New York
Aug 07, 20
Vessel Inspection - Approved Inspection
6864599
PHILADELPHIA, Pennsylvania
Nov 29, 19
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause 01 - Certificates & Documentation 011 - Ships Certificates
Description Due Date Resolved The vessel's Load Line Certificate is not endorsed to show the completion of an annual survey within the required time-frame. Vessel is restricted to a Lakes, Bays, Sounds route and shall not pass the Boundary Line until a valid Load Line Certificate is provided to and approved by the US Coast Guard. Yes
Resolved Date Resolution May 13, 22
6808099
STATEN ISLAND, New York
Sep 10, 19
Vessel Inspection - Agency Action Complete
3
0
System Subsystem Cause 09 - Working and Living Conditions 092 - Working Conditions
Description Due Date Resolved 110V panel ground detection panel indicates a ground.
46 CFR 111.05-25 Oct 10, 19 Yes
Resolved Date Resolution Nov 25, 19 Documentation was provided showing electrical work completed by certified electrician
System Subsystem Cause 09 - Working and Living Conditions 092 - Working Conditions
Description Due Date Resolved Mast can be lowered in to the haz zone. Mast head-light does not meet Class 1 Div1 standards.
46 CFR 110.105-25 Oct 09, 19 Yes
Resolved Date Resolution Nov 25, 19 Photos were provided that included instructions to secure power prior to lowering mast when entering the hazardous zone as a temporary solution. Permanent repair to be made at Drydock
System Subsystem Cause 11 - Life Saving Appliances N/A - No Subsystem
Description Due Date Resolved Vsl must have on board the number of lifebuoys directed in 46 CFR 199.271 and 46 CFR 199.70
Vsl did not meet the min requirement (03)
46 CFR 199.271 Oct 09, 19 Yes
Resolved Date Resolution Dec 12, 19 Nick Trivolis sent documentation on procuring and installing the new lifebuouys.
6649891
STATEN ISLAND, New York
Mar 27, 19
Vessel Operational Control - Agency Action Complete
6647648
STATEN ISLAND, New York
Mar 23, 19
Vessel Inspection - Agency Action Complete
1
0
System Subsystem Cause 09 - Working and Living Conditions 092 - Working Conditions
Description Due Date Resolved A BARGE MUST HAVE ANCHORS IN ACCORDANCE WITH THIS PART. THE BARGE LOST AN ANCHOR WHILE IN THE VICINITY OF PERTH AMBOY ANCHORAGE. THE ANCHOR IS TO BE REPLACED PRIOR TO MOVEMENT FROM THE BERTH AT KMI STATEN ISLAND.
46CFR32.15-15 Yes
Resolved Date Resolution Mar 24, 19 Vessel installed a new anchor and three shots of chain. ABS attended, verified installation, and satisfactorily tested the equipment. Clas report in documents.
6564221
STATEN ISLAND, New York
Oct 19, 18
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause 18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) N/A - No Subsystem Improper/Lack of Maintenance
Description Due Date Resolved Electric installations on a vessels must ensure protection of passengers, crew, other persons, and vessel electrical hazards. 120 V electrical panel in machinery space had a ground caused by a steering light in the NL-100 panel on the accommodation space. Nov 02, 18 Yes
Resolved Date Resolution Nov 20, 18 120v Ground cleared.
6326395
STATEN ISLAND, New York
Dec 19, 17
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Fire Fighting Firemans Outfit Improper/Lack of Maintenance
Description Due Date Resolved Each emergency outfit shall be equipped with an SCBA. SCBAs are past due for hydrostatic test. Jan 19, 18 Yes
Resolved Date Resolution Jan 05, 18 Received documentation indicating bottles on board had been replaced with fleet spares.
6247672
STATEN ISLAND, New York
Aug 24, 17
Vessel Inspection - Agency Action Complete
4
0
System Subsystem Cause Electrical Electric Generation Source (service)
Description Due Date Resolved Each generator prime mover must have an overspeed device that is independent of the normal operating governor. Vessel must provide a means to test the overspeed on the generators. Sep 08, 17 Yes
Resolved Date Resolution Aug 25, 17 Tests conducted
System Subsystem Cause Engineering Fuel Oil Service System Improper/Lack of Maintenance
Description Due Date Resolved Fix fuel oil injector leak on forward generator. Sep 01, 17 Yes
Resolved Date Resolution Aug 24, 17 Corrected on spot.
System Subsystem Cause Deck/Cargo Cargo Transfer (solid) Improper/Lack of Maintenance
Description Due Date Resolved The two bellows on the cargo pumps are not vapor tight. Sep 01, 17 Yes
Resolved Date Resolution Aug 25, 17
System Subsystem Cause Lifesaving Lifebuoys Improper/Lack of Maintenance
Description Due Date Resolved Two float lights on the ring buoys had expired batteries. Sep 01, 17 Yes
Resolved Date Resolution Aug 25, 17
6235545
STATEN ISLAND, New York
Aug 10, 17
Vessel Inspection - Approved Inspection
5989239
Coram, New York
Sep 01, 16
Vessel Inspection - Approved Inspection
5878771
Coram, New York
May 16, 16
Vessel Transfer Monitor - Approved Inspection
5774586
Coram, New York
Dec 02, 15
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Pollution Prevention/Response Prevention Equipment
Description Due Date Resolved Horn for High Level alarm is not working. Repair or provide new. Dec 07, 15 Yes
Resolved Date Resolution Dec 09, 15
5769750
Coram, New York
Nov 24, 15
Vessel Transfer Monitor - Approved Inspection
5752151
STATEN ISLAND, New York
Oct 28, 15
Vessel Inspection - Approved Inspection
8
0
System Subsystem Cause Accommodation/Occupational Safety Sleeping Accommodations Improper/Lack of Maintenance
Description Due Date Resolved All living spaces must have not less than two avenues of escape. The emergency escape in the crews accommodation was stuck shut and could not be opened from within the space. Oct 28, 15 Yes
Resolved Date Resolution Oct 28, 15 Item was corrected on spot by loosening escape from outside. Informed crew of importance of escape being able to quickly open it from the inside.
System Subsystem Cause Engineering Diesel Engine (auxiliary) Invalid
Description Due Date Resolved All machinery must be available and ready for testing at each periodic inspection. The genarator's low lube oil and overspeed shutdowns could not be tested at the time of inspection. USCG to witness completion of generator shutdowns. Nov 30, 15 Yes
Resolved Date Resolution Dec 02, 15 Tested generator shutdowns, low lube, high temp, and overspeed.
System Subsystem Cause Engineering Pressure Vessel Invalid
Description Due Date Resolved All pressure vessels must be available and ready for testing at each periodic inspection. The air receiver could not be internally inspected and the relief valve was not tested at the time of inspection. USCG to witness internal inspection on PV as well as test of relief valve. Nov 30, 15 Yes
Resolved Date Resolution Dec 02, 15 internally inspected, SRV tested
System Subsystem Cause Electrical Electrical Distribution System (service) Improper Installation
Description Due Date Resolved Each propulsion, power, lighting, or distribution system having a neutral bus or conductor must have the neutral grounded. If the voltage of a distribution system is less than 1000 volts, line to line, a tank vessel must not have a grounded distribution system. The dryer contains a floating neutral and therefore needs to be isolated via an individual transformer to meet the requirements. Nov 30, 15 Yes
Resolved Date Resolution Dec 02, 15
System Subsystem Cause Pollution Prevention/Response Prevention Equipment Invalid
Description Due Date Resolved Each tank barge must be equipped with a high level, overfill, and loss of power alarm. Alarms could not be tested at time of inspection due to cargo operations. USCG to witness test of all alarms. Nov 30, 15 Yes
Resolved Date Resolution Dec 02, 15 Tested satisfactory
System Subsystem Cause Deck/Cargo Vapor Control Systems Improper/Lack of Maintenance
Description Due Date Resolved Fixed pressure sensing device must be installed as close as practicable to the vessel vapor connection. Replace broken pressure gage on the aft/stbd side vapor line and verify calibration of all vapor line pressure gages. Nov 30, 15 Yes
Resolved Date Resolution Dec 02, 15 all new gauges were installed thruout barge
System Subsystem Cause Deck/Cargo Cargo Transfer/Lightering (liquid) Invalid
Description Due Date Resolved The cargo tank safety relief valves shall be inspected at least once in every two years. During a periodic inspection all pressure vacuum valves shall be exercised. Due to cargo operations the PV valves could not be operated. USCG to witness operation of all PV valves. Nov 30, 15 Yes
Resolved Date Resolution Dec 02, 15 PV's tested satisfactory
System Subsystem Cause Operations/Management Lifesaving
Description Due Date Resolved The EPIRB must be stowed in a float-free bracket. The float-free hydrostatic release is expired. Replace with valid unit. Nov 30, 15 Yes
Resolved Date Resolution Dec 02, 15 Hydro release now good thru Nov 2017
5213643
STATEN ISLAND, New York
Aug 12, 15
Vessel Inspection - Approved Inspection
5183842
STATEN ISLAND, New York
Jul 14, 15
Vessel Inspection - Approved Inspection
5098855
Coram, New York
Apr 08, 15
Vessel Transfer Monitor - Agency Action Complete
5060728
Coram, New York
Jan 28, 15
Vessel Transfer Monitor - Agency Action Complete
5014395
Coram, New York
Oct 30, 14
Vessel Inspection - Approved Inspection
4967536
STATEN ISLAND, New York
Aug 28, 14
Vessel Inspection - Agency Action Complete
4946074
STATEN ISLAND, New York
Jul 22, 14
Facility Transfer Monitor - Approved Inspection
4744029
STATEN ISLAND, New York
Oct 31, 13
Vessel Inspection - Agency Action Complete
1
0
System Subsystem Cause Deck/Cargo Cargo Transfer/Lightering (liquid)
Description Due Date Resolved MAWP stenciled on cargo hoses and piping is incorrect. Vessel must re-stencil hoses and piping with correct MAWP. 33 CFR 154.500(f)(1). Nov 14, 13 Yes
Resolved Date Resolution Nov 04, 13 Vessel provided photo documentation that all cargo piping and cargo hoses had been properly senciled.
4434702
Port Arthur, Texas
Aug 25, 12
Vessel Inspection - Approved Inspection
4421051
Morgan City, Louisiana
Aug 24, 12
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Construction/Loadline Hull
Description Due Date Resolved Tug Kristen Grace was pushing new construction barge B NO 250 (double hull) empty barge. Tug pushed up waiting to pass traffic when vessel ran aground. Issued 835 to clear after the space has been gas freed and a inspector has inspected the space to the satisfaction of the attending marine inspector. Yes
Resolved Date Resolution Aug 25, 12 Vessel DD, no damage, Coating 100% intact.
4152642
Morgan City, Louisiana
Jul 07, 11
Vessel Inspection - Approved Inspection
Documents
Issued
Expires
Agency
Cargo Authority Attachment
October 2,2012
N/A
CERTIFICATE OF DOCUMENTATION
August 12,2022
August 31,2023
USCG
Certificate of Inspection
May 13,2022
May 13,2027
USCG
Certificate of Inspection - Amended
August 9,2012
August 9,2017
N/A
Classification Document
April 17,2013
August 8,2017
ABS
International Load Line Certificate
August 9,2012
August 8,2017
ABS
International Oil Pollution Prevention Certificate
August 9,2012
August 9,2017
N/A
Int'l Oil Poll Prevention, Form B Supplement
November 8,2017
August 24,2022
SECNY
ISM - Document Of Compliance
September 13,2012
September 18,2017
ABS
ISM - Safety Management Certificate
January 7,2013
January 6,2018
ABS
NLS Certificate
January 22,2013
August 9,2017
N/A
Tonnage Certificate, International
August 8,2012
ABS