Flagship Ivy
Print Q88   
IMO/VIN Callsign Flag Service Year
9520869 V7VZ3 MARSHALL ISLANDS Tank Ship 2011
Activity# Port Date Activity - Description Deficiencies
7379736 PHILADELPHIA, Pennsylvania Jan 13, 22 Vessel Inspection - Approved Inspection
  3
SystemSubsystemCause
07 - Fire SafetyN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
FOR TANKERS OF 20000 DWT AND UPWARDS CONSTRUCTED ON OR AFTER 1JULY2002 BUT BEFORE 1JAN2016, THE PROTECTION OF THE CARGO TANKS SHALL BE AVCHIEVED BY A FIXED INERT GAS SYSTEM IN ACCORDANCE WITH THE REQUIREMENTS OF THE FSS CODE. THE ARRANGEMENT OF THE WATER SEAL OR EQUIVALENT DEVICES AND ITS ASSOCIATED FITTINGS SHALL BE SUCH THAT IT WILL PREVENT BACKFLOW OF VAPOR AND LIQUIDS AND WILL ENSURE THE PROPER FUNCTIONING. PSCO OBSERVED 2 X 1 CM HOLE IN THE DECK WATER SEAL DUE TO WASTEAGE.DECK WATER SEAL WAS FOUND ACTIVELY LEAKING DURING EXAM.Yes
Resolved DateResolution
Jan 14, 22Recieved class report attesting to repairs, condition of class has been issued. Class has approved temporary repair. No further action required, def has been cleared.
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No Subsystem
DescriptionDue DateResolved
TANKERS SHALL BE EQUIPPED WITH ATLEAST ONE PORTABLE INSTRUMENTS FOR MEASURING OXYGEN AND ONE FOR MEASURING FLAMMABLE VAPOR CONCENTRAITION TOGETHER WITH A SUFFICIENT SET OF SPARES. WHILE WITNESSING PORTABLE GAS DETECTION CALIBRATION, PSCO WITNESSED THREE FAILED SPAN GAS CALIBRATIONS ON TWO SEPERATE SPAN GAS TEST BOTTLES. VESSEL CURRENTLY HAS NO ACCURATE MEANS OF DETERMINING ATMOSPHERIC CONDITION OF CARGO TANKS, BALLAST TANKS, AND VOID SPACES.Yes
Resolved DateResolution
Jan 14, 22Recieved class report from DNV attesting to the operation of portable gas detectors. Proper gas was provided and sensors had been replaced in accordance with shoreside technical assistance.
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No Subsystem
DescriptionDue DateResolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. AT THE TIME OF INSPECTION PSCO WAS UNABLE TO WITNESS TEST OF FIXED GAS DETECTION SYSTEM. BOTH 10% AND 30% LEL ALARMS ACTIVATED. HOWEVER, LEL PERCENT CONTINUED TO READ 0.0%.Yes
Resolved DateResolution
Jan 22, 22Recieved class report from DNV attesting to the operation of fixed gas detection system. Report reviewed and found satisfactory.
6554868 New Orleans, Louisiana Oct 10, 18 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
07 - Fire SafetyN/A - No Subsystem
DescriptionDue DateResolved
07126 Fire Safety The machinery, boilers and other pressure vessels, associated piping systems and fitting shall be of a design and construction adequate for the service for which they are intended and shall be so installed and, protected as to reduce to a minimum and danger to persons on board, due regard being paid to moving parts, hot surface and other hazards. The design shall have regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected. PSCO observed 1, 2, and 4 fuel injector supply valves were closed. Upon opening valves, excessive fuel leaks were evident. 74SOLAS(14)II-1/26.1 60acYes
Resolved DateResolution
Oct 11, 18Recieved, reviewed, and accepted class report from DNV-GL stating the deficiency had be rectified. No leaks were detected.
SystemSubsystemCause
11 - Life Saving AppliancesN/A - No Subsystem
DescriptionDue DateResolved
11113 Life Saving Appliances Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed a ruptured accumulator bladder on the davit system of rescue boat which hindered operational readiness of rescue boat. 74SOLAS(14)III/20.2 17acYes
Resolved DateResolution
Oct 11, 18Recieved, reviewed, and accepted class report from DNV-GL stating the deficiency had be rectified. Rescue boat davit accumlator was replaced.
6241860 STATEN ISLAND, New York Aug 15, 17 Vessel Inspection - Approved Inspection
5965467 STATEN ISLAND, New York Aug 08, 16 Vessel Operational Control - Agency Action Complete
5795950 Miami Beach, Florida Dec 19, 15 Vessel Inspection - Approved Inspection
5031239 New Orleans, Louisiana Dec 04, 14 Vessel Inspection - Approved Inspection
4757457 Houston, Texas Dec 01, 13 Vessel Inspection - Approved Inspection
4387906 Houston, Texas Jul 23, 12 Vessel Inspection - Approved Inspection
4056756 PHILADELPHIA, Pennsylvania Jun 26, 11 Vessel Inspection - Approved Inspection
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel June 26,2011 June 26,2013 N/A
Classification Document April 29,2011 October 28,2011 GL
COC-TVE Annual July 28,2012 June 26,2013 N/A
COC-TVE Renewal June 26,2011 June 26,2013 N/A
International Load Line Certificate April 29,2011 September 28,2011 GL
International Oil Pollution Prevention Certificate April 29,2011 September 28,2011 GL
ISM - Document Of Compliance November 25,2009 November 28,2011 GL
ISM - Safety Management Certificate April 27,2011 October 28,2011 GL
Load Line Certificate (Coastwise) February 3,2016 April 28,2021 DNV
Minimum Safe Manning Document October 23,2012 MH
SOLAS Cargo Ship Safety Construction Certificate April 29,2011 September 28,2011 GL
SOLAS Cargo Ship Safety Equipment Certificate April 29,2011 September 28,2011 GL
SOLAS Cargo Ship Safety Radio Certificate April 29,2011 September 28,2011 GL
Tonnage Certificate, International June 15,2018 DNV