IMO/VIN
Callsign
Flag
Service
Year
1251312
WDM6573
UNITED STATES
Towing Vessel
2014
Activity#
Port
Date
Activity - Description
Deficiencies
7556955
STATEN ISLAND, New York
Sep 12, 22
Vessel Inspection - Agency Action Complete
7483148
STATEN ISLAND, New York
Jun 21, 22
Vessel Inspection - Approved Inspection
7408561
STATEN ISLAND, New York
Mar 09, 22
Vessel Inspection - Agency Action Complete
7358627
STATEN ISLAND, New York
Nov 29, 21
Vessel Inspection - Approved Inspection
7348936
STATEN ISLAND, New York
Nov 10, 21
Vessel Inspection - Administrative Action
7322480
New Orleans, Louisiana
Sep 28, 21
Vessel Inspection - Approved Inspection
7241885
STATEN ISLAND, New York
Jul 02, 21
Vessel Inspection - Administrative Action
7135121
STATEN ISLAND, New York
Feb 03, 21
Vessel Inspection - Approved Inspection
3
0
System Subsystem Cause 07 - Fire Safety N/A - No Subsystem Improper/Lack of Maintenance
Description Due Date Resolved 46 CFR 143.260 (b) To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shut off valve must be fitted on any fuel line that supplies fuel to engine or generator prime mover. While on board, crew was unable to located where the fuel shut off valves where resulting in the inability to witness the valves being able to close. A re-inspection with attending marine inspectors will be required for the crew to show proper closing and opening of the fuel shut off valves Apr 06, 21 Yes
Resolved Date Resolution Apr 07, 21 Remote means of fuel shut-offs verified and functioning properly.
System Subsystem Cause 01 - Certificates & Documentation 011 - Ships Certificates Improper/Lack of Maintenance
Description Due Date Resolved 46 CFR 16.230 (k) An individual may not be engaged or employed on a vessel as master, operator or person in charge for which a credential is required without being subject to the random testing requirements of this section. There were no marine employer's drug testing records. Vessel was unable to provide a list of enrolled employees, and no records of random and pre-employment tests for the last couple years. Apr 06, 21 Yes
Resolved Date Resolution Apr 07, 21 Verified Crew enrollment in the DAPI program.
System Subsystem Cause 11 - Life Saving Appliances N/A - No Subsystem Placed in Improper Service
Description Due Date Resolved 46 CFR 199.130 (c)(3) Each life raft must be arranged to permit it to drop into the water from the deck on which it is stowed. Life raft on board is stowed in a alongside continuous handrail above bridge in a secured cradle which does not allow for manual release into the water from its securing arrangements. Vessel must provide a plan proposal for addressing this issue. Apr 06, 21 Yes
Resolved Date Resolution Apr 07, 21 Liferaft launching arrangements properly installed.
6957229
STATEN ISLAND, New York
May 21, 20
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause 01 - Certificates & Documentation 011 - Ships Certificates
Description Due Date Resolved All owners and operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is one of the 25% of the vessels that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 30 days. If an inspection is not completed prior to this date, the action for this deficiency
shall be changed to a 60 (Rectify deficiencies prior to (movement) and the vessel may no long be permitted to operate. Jun 21, 20 Yes
Resolved Date Resolution Apr 07, 21 COI inspection satisfactory completed. Issued COI.
6906076
PHILADELPHIA, Pennsylvania
Feb 10, 20
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause 01 - Certificates & Documentation 011 - Ships Certificates
Description Due Date Resolved The vessel currently only has a master onboard. The vessel must meet the manning requirement of one Master, one Mate, and two deckhands prior to movement. Yes
Resolved Date Resolution Apr 19, 20 Vessel was manned correctly
6755392
STATEN ISLAND, New York
Jul 12, 19
Vessel Inspection - Administrative Action
6454946
Savannah, Georgia
Jun 25, 18
Uninspected Towing Vessel Exam - Approved Inspection
6324052
STATEN ISLAND, New York
Dec 14, 17
Vessel Operational Control - Agency Action Complete
5238528
ST PETERSBURG, Florida
Sep 04, 15
Vessel Transfer Monitor - Agency Action Complete
5238528
Tampa, Florida
Sep 04, 15
Vessel Transfer Monitor - Agency Action Complete
5131407
Lake Charles, Louisiana
May 21, 15
Boarding - Agency Action Complete
5074022
Lake Charles, Louisiana
Mar 09, 15
Uninspected Towing Vessel Exam - Approved Inspection
Documents
Issued
Expires
Agency
CERTIFICATE OF DOCUMENTATION
December 22,2022
January 31,2024
USCG
Certificate of Inspection
March 23,2021
March 23,2026
USCG
Certificate of Inspection - Amended
March 23,2021
March 23,2026
USCG
Classification Document
July 3,2014
May 26,2019
ABS
International Load Line Certificate
May 27,2014
May 26,2019
ABS
International Oil Pollution Prevention Certificate
May 27,2014
May 26,2019
ABS
ISM - Document Of Compliance
July 26,2017
September 18,2022
ABS
ISM - Safety Management Certificate
October 22,2014
October 2,2019
ABS
Stability Letter
May 20,2014
ABS
Tonnage Certificate, International
May 20,2014
ABS
Tonnage Certificate, U.S.
May 20,2014
ABS