Ridgebury Katherine Z
Print Q88   
IMO/VIN Callsign Flag Service Year
9439797 V7CT5 MARSHALL ISLANDS Tank Ship 2009
Activity# Port Date Activity - Description Deficiencies
7282616 Port Arthur, Texas Aug 04, 21 Vessel Operational Control - Agency Action Complete
7282527 Port Arthur, Texas Jul 31, 21 Vessel Operational Control - Agency Action Complete
7219681 Port Arthur, Texas Jun 11, 21 Vessel Inspection - Agency Action Complete
6935654 Mobile, Alabama Apr 05, 20 Vessel Operational Control - Approved Inspection
6885958 San Francisco, California Jan 09, 20 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
07 - Fire SafetyN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
For tankers of 20,000 tonnes deadweight and upwards constructed on or after 1 July 2002 but before 1 January 2016, the protection of the argo tanks shall be achieved by a fixed inert gas system in accordance with the requirements of the Fire Safety Systems Code, as adopted by Resolution MSC.98/73, except that the Administration may accept other equivalent systems or arrangements as described in paragragh 5.5.4. The inert gas system referred to in Chapter II-2 of the Convention shall be designed, constructed, and tested to the satisfaction of the Administration. PSCO observed air leaking from windbox of IGG combustion chamber.Feb 12, 20Yes
Resolved DateResolution
Jan 14, 20Air box permanently repaired. Class attended and tested IGG, no further leaks found. See class report for further details.
SystemSubsystemCause
02 - Structural ConditionsN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
In tankers, electrical installations shall not be installed in hazardous locations unless it conforms with standards not inferior to those acceptable. On deck explosion-proof lighting was corroded and cracked on amidship location, starboard side. Another explosion-proof lighting on deck, forward, bow area, starboard side, had several holes and corrosion on casing.Jan 09, 20Yes
Resolved DateResolution
Jan 09, 20Spare parts onboard the vessel were used to replace light fixtures.
6815173 STATEN ISLAND, New York Sep 19, 19 Vessel Inspection - Approved Inspection
6621342 Seattle, Washington Feb 06, 19 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
15 - Safety Management Systems (ISM)N/A - No Subsystem
DescriptionDue DateResolved
2535 - THE COMPANY SHOULD ESTABLISH PROCEDURES, PLANS, AND INSTRUCTIONS, INCLUDING CHECKLISTS AS APPROPRIATE, FOR KEY SHIPBOARD OPERATIONS CONCERNING THE SAFETY OF THE PERSONNEL, SHIP, AND PROTECTION OF THE ENVIRONMENT. THE VARIOUS TASKS SHOULD BE DEFINED AND ASSIGNED TO QUALIFIED PERSONNEL. VESSEL MIS-SOUNDED TANK DURING BUNKER OPERATIONS, SPILLING AN UNKNOWN QUANTITY OF MDO OVER THE SIDE. RECOMMEND SMS AUDIT TO FOCUS ON BUNKERING PROCEDURES. - ISM (2018) A/7 - 40.A.B.C.Yes
Resolved DateResolution
Mar 13, 19ISM Audit report attests to rectification
6650553 WASHINGTON, District of Columbia Feb 05, 19 Incident Investigation - Agency Action Complete
6612748 San Pedro, California Jan 29, 19 Vessel Inspection - Approved Inspection
6600972 CORPUS CHRISTI, Texas Dec 20, 18 Vessel Inspection - Agency Action Complete
6586523 New Orleans, Louisiana Nov 26, 18 Vessel Inspection - Agency Action Complete
6512734 San Juan, Puerto Rico Aug 18, 18 Vessel Inspection - Approved Inspection
6391421 Lake Charles, Louisiana Apr 19, 18 Vessel Inspection - Approved Inspection
6315682 Lake Charles, Louisiana Nov 30, 17 Vessel Inspection - Approved Inspection
6098163 San Francisco, California Mar 02, 17 Vessel Inspection - Approved Inspection
6096771 San Francisco, California Mar 01, 17 Vessel Operational Control - Agency Action Complete
6098779 WASHINGTON, District of Columbia Mar 01, 17 Incident Investigation - Agency Action Complete
6071914 TEXAS CITY, Texas Jan 22, 17 Vessel Inspection - Approved Inspection
5787929 New Orleans, Louisiana Dec 28, 15 Vessel Inspection - Administrative Action
5748864 New Orleans, Louisiana Dec 02, 15 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
CommunicationsAlarms/IndicatorsDamaged By Earlier Event
DescriptionDue DateResolved
0999 - Safety - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO was informed the vessel's forward port, starboard, and steering gear bilge alarms were inoperative. 74 SOLAS (09) cons I/11(a)Jan 03, 16Yes
Resolved DateResolution
Dec 28, 15PSC NOLA received a class report from DNV-GL satisfying the requirement.
5150136 New Orleans, Louisiana Jun 11, 15 Vessel Inspection - Agency Action Complete
5012702 NEW HAVEN, Connecticut Oct 27, 14 Vessel Inspection - Approved Inspection
4884092 New Orleans, Louisiana Jun 16, 14 Vessel Inspection - Approved Inspection
4875146 TEXAS CITY, Texas May 31, 14 Vessel Operational Control - Approved Inspection
4776353 San Juan, Puerto Rico Jan 01, 14 Vessel Inspection - Approved Inspection
4729579 Mobile, Alabama Oct 12, 13 Vessel Inspection - Approved Inspection
4662556 Woods Hole, Massachusetts Jul 23, 13 Enforcement - Agency Action Complete
4662525 Woods Hole, Massachusetts Jul 23, 13 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Operations/ManagementMandatory Ship Reporting Systems
DescriptionDue DateResolved
Vessel failed to submit and ANOA to the Sector SENE port before arriving and anchoring at Brenton Reef. The vessel must submit an ANOA in compliance with the regulations under 33 CFR 160Jul 23, 13Yes
Resolved DateResolution
Jul 23, 13Vessel Submitted ANOA
4650463 STATEN ISLAND, New York Jul 11, 13 Vessel Inspection - Approved Inspection
4645296 STATEN ISLAND, New York Jul 11, 13 Boarding - Agency Action Complete
4442075 CORPUS CHRISTI, Texas Oct 01, 12 Vessel Inspection - Approved Inspection
4195600 Christiansted, Virgin Islands Dec 05, 11 Vessel Inspection - Approved Inspection
4040886 New Orleans, Louisiana Jun 10, 11 Vessel Inspection - Administrative Action
3813253 Houston, Texas Aug 02, 10 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Construction/LoadlineMarkingsPlaced in Improper Service
DescriptionDue DateResolved
Vessel shall have mark of authority by whom the load lines are asisgned alongside the load line ring. Vessel was marked as an ABS vessel with "AB" despite load line authority of NKK.Yes
Resolved DateResolution
Aug 02, 10Vessel made correction on spot by painting over "AB" and clearly painting "NK" in contrasting color IAW Annex I Reg 8 of same reference.
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel January 2,2014 October 1,2014 N/A
Certificate of Fitness - Chemical Carrier November 18,2014 September 30,2019 DNV
Classification Document July 13,2019 September 30,2024 Class
COC-TVE Annual October 22,2015 October 22,2016 N/A
International Certificate of Fitness - Chemical July 13,2019 September 30,2024 Class
International Load Line Certificate July 13,2019 September 30,2024 Class
International Oil Pollution Prevention Certificate September 13,2018 September 30,2019 DNV
ISM - Document Of Compliance July 25,2012 October 20,2014 NKK
ISM - Safety Management Certificate April 20,2018 September 30,2018 LR
Minimum Safe Manning Document February 17,2010 September 30,2014 TR
SOLAS Cargo Ship Safety Construction Certificate July 13,2019 September 30,2024 Class
SOLAS Cargo Ship Safety Equipment Certificate July 13,2019 September 30,2024 Class
SOLAS Cargo Ship Safety Radio Certificate July 13,2019 September 30,2024 Class
Tonnage Certificate, International March 28,2014 NKK