Torm Atlantic
Print Q88   
IMO/VIN Callsign Flag Service Year
9433509 9V3389 SINGAPORE Tank Ship 2010
Activity# Port Date Activity - Description Deficiencies
7289147 Jacksonville, Florida Aug 20, 21 Boarding - Agency Action Complete
7290211 Jacksonville, Florida Aug 18, 21 Vessel Inspection - Administrative Action
7132417 STATEN ISLAND, New York Jan 28, 21 Vessel Inspection - Approved Inspection
7132502 STATEN ISLAND, New York Jan 28, 21 Boarding - Agency Action Complete
6550895 STATEN ISLAND, New York Sep 28, 18 Vessel Inspection - Approved Inspection
6235290 Port Arthur, Texas Aug 11, 17 Vessel Inspection - Approved Inspection
6240192 Lake Charles, Louisiana Aug 11, 17 Boarding - Agency Action Complete
6234510 Port Arthur, Texas Aug 11, 17 Boarding - Agency Action Complete
5155786 New Orleans, Louisiana May 30, 15 Vessel Inspection - Approved Inspection
5139110 New Orleans, Louisiana May 29, 15 Vessel Operational Control - Agency Action Complete
5139240 WASHINGTON, District of Columbia May 29, 15 Incident Investigation - Agency Action Complete
5155853 New Orleans, Louisiana May 29, 15 Vessel Inspection - Approved Inspection
5137685 New Orleans, Louisiana May 28, 15 Vessel Operational Control - Agency Action Complete
5137823 WASHINGTON, District of Columbia May 27, 15 Incident Investigation - Agency Action Complete
5127538 New Orleans, Louisiana May 23, 15 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
PersonnelTraining
DescriptionDue DateResolved
0725 - Fixed fire extinguishing installation - Crew was unfamiliar with requirments of hyper-mist system and secured section valve for #3 Aux Engine rendering it inoperable. SOLAS XI-1/4May 23, 15Yes
Resolved DateResolution
May 24, 15Received, reviewed and accepted class report from ABS satisfying the requirements. Vessel made proper notifications to owner''s safety management system and they were accepted.
SystemSubsystemCause
Fire FightingFixed Pressure Water-Spraying Fire Extinguishing System
DescriptionDue DateResolved
0725 - Fixed fire extinguishing installation - PSCO found hyper-mist section valve for #3 Aux Engine in the closed position. SOLAS II-2/14May 23, 15Yes
Resolved DateResolution
May 24, 15Received, reviewed and accepted class report from ABS satisfying the requirement. Valve had been repaired, tested and found satisfactory by attending surveyor.
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel January 28,2021 January 28,2023 N/A
Certificate of Fitness - Chemical Carrier December 23,2020 February 2,2025 Class
Classification Document February 11,2015 July 10,2015 RINA
COC-TVE Renewal January 28,2021 January 28,2023 N/A
International Certificate of Fitness - Chemical April 20,2016 February 2,2020 ABS
International Load Line Certificate February 11,2015 July 10,2015 RINA
International Oil Pollution Prevention Certificate March 17,2017 May 17,2022 ABS
ISM - Document Of Compliance May 7,2015 October 6,2015 RINA
ISM - Safety Management Certificate February 20,2015 July 19,2015 RINA
Minimum Safe Manning Document July 28,2016 SG
NLS Certificate April 20,2016 ABS
SOLAS Cargo Ship Safety Construction Certificate February 11,2015 July 10,2015 RINA
SOLAS Cargo Ship Safety Equipment Certificate February 11,2015 July 10,2015 RINA
SOLAS Cargo Ship Safety Radio Certificate February 11,2015 July 10,2015 RINA
Tonnage Certificate, International January 7,2016 ABS