Ns Stream
Print Q88   
IMO/VIN Callsign Flag Service Year
9318541 A8HY4 LIBERIA Tank Ship 2006
Activity# Port Date Activity - Description Deficiencies
7325778 Honolulu, Hawaii Oct 08, 21 Vessel Inspection - Approved Inspection
7054157 New Orleans, Louisiana Sep 11, 20 Vessel Inspection - Approved Inspection
6685792 STATEN ISLAND, New York May 16, 19 Vessel Inspection - Approved Inspection
6403761 NEW HAVEN, Connecticut May 02, 18 Vessel Inspection - Approved Inspection
6255311 STATEN ISLAND, New York Aug 30, 17 Vessel Inspection - Administrative Action
6129512 STATEN ISLAND, New York Apr 21, 17 Vessel Inspection - Approved Inspection
6011293 Houston, Texas Sep 28, 16 Vessel Inspection - Approved Inspection
6010176 New Orleans, Louisiana Sep 28, 16 Vessel Inspection - Approved Inspection
5839744 ST PETERSBURG, Florida Mar 24, 16 Vessel Inspection - Approved Inspection
5839744 Tampa, Florida Mar 24, 16 Vessel Inspection - Approved Inspection
5048437 New Orleans, Louisiana Jan 05, 15 Vessel Inspection - Administrative Action
4976050 TEXAS CITY, Texas Sep 09, 14 Vessel Inspection - Approved Inspection
4971435 Houston, Texas Sep 01, 14 Vessel Inspection - Failure to Show
4697337 San Juan, Puerto Rico Aug 28, 13 Vessel Inspection - Approved Inspection
4579874 New Orleans, Louisiana Apr 30, 13 Vessel Inspection - Administrative Action
  1
SystemSubsystemCause
NavigationCollision/Grounding Avoidance
DescriptionDue DateResolved
The S band radar was reported not operationalApr 30, 13Yes
Resolved DateResolution
Apr 30, 1330APR2013: Received a class/tech report. The report stated the (list equipment) was repaired, tested and found operating satisfactory. Cleared deficiency
4321611 San Juan, Puerto Rico May 25, 12 Vessel Inspection - Approved Inspection
4314882 San Juan, Puerto Rico May 18, 12 Vessel Inspection - Agency Action Complete
3930934 New Orleans, Louisiana Jan 22, 11 Boarding - Agency Action Complete
3787708 STATEN ISLAND, New York Jul 06, 10 Vessel Inspection - Approved Inspection
3518623 PHILADELPHIA, Pennsylvania Jun 29, 09 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
LifesavingLifeboat EquipmentUnknown
DescriptionDue DateResolved
0611 - Lifeboat Inventory - Lifeboats are to have food rations kept in airtight packaging totalling not less than 10,000 KJ for each person the lifeboat is certified to carry. 11 rations in free-fall lifeboat are no longer air-tight. Vessel is to replace affected lifeboat rations prior to departure. SOLAS 74 (2004 Cons Ed.) CH III Reg 13.1.4 / LSA 4.4.8.12Yes
Resolved DateResolution
Jun 30, 09Sector Delaware Bay received receipt for purchase of 24 Food Rations via E-mail
3299500 Woods Hole, Massachusetts Aug 15, 08 Vessel Inspection - Approved Inspection
3246864 Savannah, Georgia Jun 23, 08 Vessel Inspection - Agency Action Complete
  2
SystemSubsystemCause
DocumentationCertificates/Documents
DescriptionDue DateResolved
IOPP has incinerator for waste oil listed at 70 liters/hour the manual for the incinerator is states 70 kg/hr. Have IOPP corrected by Flag to reflect proper units for the oil waste incinerator.Yes
Resolved DateResolution
Aug 15, 08Det Norske Veritas issued a new IOPP Certificate and new IOPP Supplement to the vessel correcting the discrepancy outlined above. The correct throughput capacity (now reflected on both the equipment and the certificate) is 70 kg/hr.
SystemSubsystemCause
Deck/CargoInert Gas System
DescriptionDue DateResolved
Provide USCG approved letter for the vessels block and bleed system prior to returning to U.S. waters after sailing foreign.Yes
Resolved DateResolution
Aug 19, 08Received MSC Approval Ltr for IGS Double Block and Bleed alternative for the M/V NS STREAM, IMO#9318541. After reviewing the letter and supporting documents the vessel may have the IGS Block and Bleed alternative to the wet or semi-wet seal.
3153082 Brownsville, Texas Feb 25, 08 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Fire FightingFixed Fire Detection System
DescriptionDue DateResolved
Fire Detecting System was report was inoperative.Feb 27, 08Yes
Resolved DateResolution
Feb 27, 08Fire Detecting System was repaired by crew.
3035571 STATEN ISLAND, New York Aug 22, 07 Vessel Operational Control - Agency Action Complete
3006934 STATEN ISLAND, New York Jul 25, 07 Vessel Inspection - Agency Action Complete
2976299 STATEN ISLAND, New York Jun 28, 07 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
Bilge Oily Water Content Meter, crew was not able to bring the unit down to 0-2 PPM as per the manufacture; crew could only bring it down only to 16 ppm. Oil Content Meter to be cleaned, calibrated and retested to the satisfaction of Class.Jul 28, 07Yes
Resolved DateResolution
Jul 25, 07Received Det Norske Veritas survey report attesting that the measuring cell of the OWS has been ordered and fitted
SystemSubsystemCause
DocumentationCertificates/Documents
DescriptionDue DateResolved
Vessel is not in compliance with the revisions of MARPOL Annex II, which came into force after 31DECF06. The following items have not been approved, or update to reflect the revisions, Certificate of Fitness, P & A Manual, nor the Cargo record Book. Vessel is prohibited from carrying Annex II cargos until vessel can prove compliance.Yes
Resolved DateResolution
Jul 25, 07Received Det Norske Veritas Certificate of Fitness verifying that the vessel is in full compliance with MARPOL Annex II requirements. ENS N. Gordon USCG Sector NY Port State Control
2810878 Brownsville, Texas Oct 30, 06 Vessel Inspection - Agency Action Complete
2781192 Savannah, Georgia Sep 18, 06 Vessel Inspection - Agency Action Complete
2677853 Savannah, Georgia Jun 12, 06 Vessel Inspection - Agency Action Complete
  6
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
#1 cargo line has temporary repair due to leakage. Vessel is not to use #1 cargo line while in U.S. waters until satisfactory class report is received.Jul 11, 06Yes
Resolved DateResolution
Jun 29, 06Received class report verifying repairs to cargo line #1.
SystemSubsystemCause
Fire FightingFire Pumps
DescriptionDue DateResolved
#1 fire pump is dismantled awaiting spare partsJun 19, 06Yes
Resolved DateResolution
Sep 11, 06Received Class report attesting to repairs.
SystemSubsystemCause
Fire FightingMiscellaneous Items
DescriptionDue DateResolved
Fire damper for oil seperator room is tied in the open position.Jun 19, 06Yes
Resolved DateResolution
Sep 11, 06Received Class report attesting to repairs.
SystemSubsystemCause
Fire FightingFixed Deck Foam System
DescriptionDue DateResolved
Foam fire fighting system contaminated with sea water. Vessel is not allowed to conduct cargo operations until satisfactory plan of fire protection is received and approved by CG COTP, or replace foam, or supply CG with satisfactory foam analysis report.Yes
Resolved DateResolution
Jun 15, 06Recieved Class report verifying foam was replaced.
SystemSubsystemCause
Deck/CargoCargo Stowage
DescriptionDue DateResolved
Signage for high level and overfill alarms are reversed at front of pilot house/bridge.Jul 11, 06Yes
Resolved DateResolution
Sep 11, 06Received class report attesting to repairs.
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
Span gas for portable explosive meters not on board. Fix prior to departure.Yes
Resolved DateResolution
Jun 15, 06Received receipt for purchase of span gas.
2676985 Savannah, Georgia Jun 12, 06 Boarding - Agency Action Complete
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel October 8,2021 October 8,2023 N/A
Certificate of Fitness - Chemical Carrier May 8,2006 October 7,2006 DNV
Classification Document May 8,2006 October 7,2006 DNV
COC-TVE Renewal June 12,2006 June 12,2009 N/A
International Load Line Certificate May 8,2006 October 7,2006 DNV
International Oil Pollution Prevention Certificate May 8,2006 October 7,2006 DNV
ISM - Document Of Compliance May 30,2013 October 5,2017 LR
ISM - Safety Management Certificate September 9,2011 September 9,2016 N/A
Minimum Safe Manning Document November 7,2016 N/A
SOLAS Cargo Ship Safety Certificate June 30,2021 May 5,2026 Class
SOLAS Cargo Ship Safety Construction Certificate May 8,2006 October 7,2006 DNV
SOLAS Cargo Ship Safety Equipment Certificate May 8,2006 October 7,2006 DNV
SOLAS Cargo Ship Safety Radio Certificate May 8,2006 October 7,2006 DNV
Tonnage Certificate, International April 24,2006 DNV