Ym Venus
Print Q88   
IMO/VIN Callsign Flag Service Year
9291585 9HCB8 MALTA Tank Ship 2005
Activity# Port Date Activity - Description Deficiencies
3424915 San Juan, Puerto Rico Feb 27, 09 Enforcement - Agency Action Complete
3424638 San Juan, Puerto Rico Feb 26, 09 Vessel Inspection - Agency Action Complete
3418984 San Juan, Puerto Rico Feb 17, 09 Vessel Inspection - Approved Inspection
3413261 San Juan, Puerto Rico Feb 06, 09 Vessel Inspection - Approved Inspection
  7   1
SystemSubsystemCause
Fire FightingFixed Fire Detection SystemImproper/Lack of Maintenance
DescriptionDue DateResolved
Gas sampling panel in cargo control room is showing a "flow error" for all tanks sampled. Make proper repairs to cargo sampling system no later than 05 MAR 2009 to Class/RO/RSO. Prior to completion of repairs conduct ballast tank sampling LEL levels prior to and following all loading and unloading cargo operations using vessels portable gas detectors. 04 SOLASMar 05, 09Yes
Resolved DateResolution
Feb 27, 09Received fax from Class stating that the gas sampling panel has been repaired and satisfactorily tested.
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational SafetyDamaged By Earlier Event
DescriptionDue DateResolved
Hand rails on deck at port side forward and on starboard forward are broken. Make the permanent arrangement to fix it no later than APR 2009 to the satisfaction of Class/RO/RSO. Requirement due date extended until vessel drydock in JAN 2010.Jan 01, 10No
SystemSubsystemCause
Pollution Prevention/ResponsePrevention EquipmentImproper Installation
DescriptionDue DateResolved
MSD is not properly placarded in accordance with 33 CFR 159.7. Device should be properly placard by 20 FEB 2009 to the satisfaction of Class/RO/RSO.Feb 20, 09Yes
Resolved DateResolution
Feb 17, 09ABS quality assessment certificate received VIA E-MAIL attesting to system approval.
SystemSubsystemCause
EngineeringSea-water System (primary cooling)Improper/Lack of Maintenance
DescriptionDue DateResolved
Raw water cooling delivery and return lines (Piping) on generator #3 are wasted due to leaks at flex coupling. Make permanent repairs to the satisfaction of class/RO/RSO no later than 13 FEB 2009. 04 SOLAS (Amend) II-1/41.Feb 13, 09Yes
Resolved DateResolution
Feb 17, 09BV Declares That They Surveyed The Ship And Found The Deficiency Corrected
SystemSubsystemCause
EngineeringSea-water System (primary cooling)Improper/Lack of Maintenance
DescriptionDue DateResolved
Raw water cooling delivery piping on generator #1 is wasted at flex-coupling due to leaks. Make permanent repairs no later than 13 FEB 09 to the satisfaction of class/RO/RSO. 04 SOLAS (Ammend) II-1/41.Feb 13, 09Yes
Resolved DateResolution
Feb 17, 09BV Declares That They Surveyed The Ship And Found The Deficiency Corrected
SystemSubsystemCause
Fire FightingMeans of EscapeUnknown
DescriptionDue DateResolved
Self closing door at emergency fire escape trunk in lowest level of engine room sticks open, make proper repairs to ensure door is able to self close. No later than 13 FEB 2009 to the satisfaction of Class/RO/RSO.Feb 13, 09Yes
Resolved DateResolution
Feb 17, 09BV Declares That They Surveyed The Ship And Found The Deficiency Corrected
SystemSubsystemCause
Pollution Prevention/ResponseResponse Equipment
DescriptionDue DateResolved
Vessel is required to have 04 chemical safety suits onboard. Vessel currently has 03 chemical safety suits onboard. Provide 01 additional chemical suit onboard vessel no later than 20 FEB 2009 to satisfaction of Class/RO/RSO. 04 SOLAS II-2/19Feb 20, 09Yes
Resolved DateResolution
Feb 17, 09Received Class report stating deficiency cleared.
SystemSubsystemCause
Fire FightingFixed Fire Detection System
DescriptionDue DateResolved
When fire alarm in engine room is activated both the fire and CO2 lights on the signal panel in the space illuminate, separate alarm indicators to reflect appropriate alarms no later than 05 MAR 2009 to satisfaction of Class/RO/RSO. 04 SOLAS II-1/7.4.2Mar 05, 09Yes
Resolved DateResolution
Feb 17, 09BV Declares That They Surveyed The Ship And Found The Deficiency Corrected
2532958 Houston, Texas Nov 11, 05 Vessel Inspection - Agency Action Complete
2534528 Houston, Texas Nov 04, 05 Vessel Inspection - Agency Action Complete
2527708 Savannah, Georgia Nov 02, 05 Vessel Inspection - Agency Action Complete
  6
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
#2P cargo pump is inoperable. Vessel may not load in #2P cargo tank until cargo pump and emergency stop is tested to satisfaction of Class.Yes
Resolved DateResolution
Nov 11, 05Recieved satisfactory class report.
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
MSD has missing placard.Nov 02, 05Yes
Resolved DateResolution
Nov 02, 05Vessel placed placard on MSD.
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
OWS oil content meter needs new dessicator and needs to be calibrated. Vessel to have oily waste retained onboard or sent to reception facility. Rectify to Class.Yes
Resolved DateResolution
Nov 11, 05Received satisfactory class report.
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
Vessel to prove proper calibration and operation of fixed gas detection system to the satisfaction of class.Yes
Resolved DateResolution
Nov 11, 05Received satisfactory class report.
SystemSubsystemCause
Deck/CargoVapor Control Systems
DescriptionDue DateResolved
Vessel vapor piping flange at manifold is not approved by class and is missing stud. System is not to be used in U.S. waters until inspected by class.Dec 02, 05Yes
Resolved DateResolution
Feb 02, 09AGENT FAXED TO SECTOR SAN JUAN PREVENTION DEPARTMENT A BV CERTIFICATION FOR THE VAPORS CONTROL SYSTEMS ON M/T YM VENUS
SystemSubsystemCause
DocumentationSafety/Response Plans/Programs
DescriptionDue DateResolved
Vessels fire control plan states that the bridge and separator room in E/R have gas tight doors. Both doors are not gas tight. Class must address this issue,Yes
Resolved DateResolution
Nov 11, 05Recieved satisfactory class report.
2526819 Savannah, Georgia Nov 02, 05 Boarding - Agency Action Complete
Documents Issued Expires Agency
Certificate of Fitness - Chemical Carrier August 23,2005 January 24,2010 BV
Classification Document August 23,2005 BV
International Load Line Certificate August 23,2005 January 24,2010 BV
International Oil Pollution Prevention Certificate August 23,2005 January 24,2010 BV
ISM - Document Of Compliance July 14,2005 June 16,2010 LR
ISM - Safety Management Certificate July 9,2008 June 26,2013 LR
SOLAS Cargo Ship Safety Construction Certificate August 23,2005 January 24,2010 BV
SOLAS Cargo Ship Safety Equipment Certificate August 23,2005 January 24,2010 BV
SOLAS Cargo Ship Safety Radio Certificate August 23,2005 January 24,2010 BV
Tonnage Certificate, International March 28,2005 BV