Grand Ace9
Print Q88   
IMO/VIN Callsign Flag Service Year
9443865 D7TC SOUTH KOREA Tank Ship 2008
Activity# Port Date Activity - Description Deficiencies
7026586 TEXAS CITY, Texas Aug 11, 20 Vessel Inspection - Approved Inspection
7027807 Houston, Texas Aug 09, 20 Boarding - Agency Action Complete
6684970 San Juan, Puerto Rico May 22, 19 Vessel Inspection - Approved Inspection
6406066 Honolulu, Hawaii May 12, 18 Vessel Inspection - Approved Inspection
6163357 TEXAS CITY, Texas Jun 10, 17 Vessel Inspection - Approved Inspection
6114913 New Orleans, Louisiana Mar 31, 17 Vessel Inspection - Approved Inspection
6107946 Houston, Texas Mar 20, 17 Vessel Operational Control - Agency Action Complete
6105133 Port Arthur, Texas Mar 15, 17 Vessel Operational Control - Approved Inspection
6068341 Houston, Texas Jan 09, 17 Vessel Operational Control - Agency Action Complete
6038456 WASHINGTON, District of Columbia Nov 10, 16 Incident Investigation - Agency Action Complete
5884206 Houston, Texas May 23, 16 Vessel Inspection - Approved Inspection
5102587 FPO, AP, Guam Apr 14, 15 Vessel Inspection - Approved Inspection
5032580 FPO, AP, Guam Dec 02, 14 Vessel Inspection - Approved Inspection
  5
SystemSubsystemCause
LifesavingLifeboat
DescriptionDue DateResolved
Before the ship leaves port and all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. 74SOLAS(09Cons)III/20.2 The propulsion as required by LSS in inoperable on the port side lifeboat. Yes
Resolved DateResolution
Dec 12, 14Ship''''''''s engineers made repairs to the motor lifeboats engine to restore it to an operable condition.
SystemSubsystemCause
PersonnelCertificates/Documents/Licenses
DescriptionDue DateResolved
Certificates of a competency shall be issued only by the Administration, following the verification and validity of any necessary documentary evidence. STCWI/2.1 The application of license of the 2nd engineer is expired. Yes
Resolved DateResolution
Dec 12, 14The Administration provided a copy of the new valid license of the 2nd engineer.
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship and persons on board. 74SOLAS(09Cons)I/11(a) The #4 power pack and non-metallic expansion joints are leaking hydraulic oil. Yes
Resolved DateResolution
Apr 12, 15Attending DNVGL Surveyor attested to ssatisfactory replacement of non metallic power pack expansion joints.
SystemSubsystemCause
Deck/CargoInert Gas SystemImproper/Lack of Maintenance
DescriptionDue DateResolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship and persons on board. 74SOLAS(09Cons)I/11(a) The non metallic expansion joint on the #1 IGS fan is badly deteriorated. Apr 12, 15Yes
Resolved DateResolution
May 28, 16Attending DNVGL surveyor attested to satisfactory replacement of the non metallic expansion joint at the IGS Blower Fan.
SystemSubsystemCause
Deck/CargoInert Gas System
DescriptionDue DateResolved
The inert Gas System shall be designed, constructed and tested in accordance with the FSS code. For Inert Gas Systems, audible and visual alarms shall be provided. 74SOLAS(09Cons)II-2/4.5.5.3.2 The Inert Gas system Main Panel in CCR and sub-panel in ECR does not have a working audible alarm. Yes
Resolved DateResolution
Dec 12, 14Ship''''s engineers made repairs to the alarm panel that restored the inert gas generator alarms to an operable condition.
4851031 JBER, Alaska May 05, 14 Enforcement - Payment Received
4848334 JBER, Alaska May 01, 14 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
DocumentationSafety/Response Plans/Programs
DescriptionDue DateResolved
Vessel transited the WAK COTP Zone without having the approved GSA for WAK.May 01, 14Yes
Resolved DateResolution
May 01, 15Issued NOV
4840695 Seattle, Washington Apr 21, 14 Vessel Inspection - Approved Inspection
4810313 Seattle, Washington Mar 11, 14 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
DocumentationCertificates/Documents
DescriptionDue DateResolved
0135 - Minimum safe manning certificate - Every ship shall be provided with an appropriate Minimum Safe Manning document. Vessel's Minimum Safe Manning document does not comply with ammendment A.1047(27) specifically does not include company name or whether engine room is periodically unmanned. SOLAS 74 (2009 Cons.) V/14.2.1 - Code: 16 b/c.Mar 25, 14Yes
Resolved DateResolution
Apr 21, 14The vessel was issued a new Minimum Safe Manning Document by flag on 20MAR14. The vessel submitted a copy to Sector Puget Sound.
4466252 San Pedro, California Oct 22, 12 Vessel Inspection - Agency Action Complete
4072433 Woods Hole, Massachusetts Jul 03, 11 Boarding - Agency Action Complete
4063136 Woods Hole, Massachusetts Jun 30, 11 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
ElectricalElectric Generation Source (emergency)
DescriptionDue DateResolved
Inert gas cabinet at cargo control room audible alarm inoperable/missing. SOLAS (CONS) 2009 II-2/4.5.5 FSS CODE 15.2.4.3Jul 17, 11Yes
Resolved DateResolution
Jul 05, 11Inert gas cabinet at cargo control room audible alarm installed and operating
3930377 San Juan, Puerto Rico Jan 24, 11 Boarding - Agency Action Complete
3729682 Port Arthur, Texas May 04, 10 Vessel Inspection - Approved Inspection
3636993 JBER, Alaska Nov 20, 09 Vessel Inspection - Agency Action Complete
3449417 STATEN ISLAND, New York Apr 09, 09 Vessel Inspection - Approved Inspection
3418053 STATEN ISLAND, New York Feb 15, 09 Vessel Operational Control - Agency Action Complete
3403361 New Orleans, Louisiana Feb 04, 09 Vessel Inspection - Approved Inspection
3228621 STATEN ISLAND, New York Jun 06, 08 Vessel Operational Control - Administrative Action
3212788 New Orleans, Louisiana May 25, 08 Vessel Inspection - Approved Inspection
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel December 12,2014 December 12,2016 USCG
Certificate of Fitness - Chemical Carrier August 21,2013 March 27,2018 DNV
Classification Document June 24,2013 March 27,2018 DNV
International Certificate of Fitness - Chemical August 21,2013 March 27,2018 DNV
International Load Line Certificate December 1,2016 March 27,2018 DNV GL
International Oil Pollution Prevention Certificate May 16,2016 March 27,2018 DNV GL
ISM - Document Of Compliance June 17,2008 March 20,2012 ABS
ISM - Safety Management Certificate March 25,2018 September 24,2018 KR
SOLAS Cargo Ship Safety Construction Certificate April 12,2015 March 27,2018 DNV GL
SOLAS Cargo Ship Safety Equipment Certificate August 19,2008 March 28,2013 N/A
SOLAS Cargo Ship Safety Radio Certificate June 24,2013 March 27,2018 DNV