Overseas Boston
Print Q88   
IMO/VIN Callsign Flag Service Year
1207239 WJBU UNITED STATES Tank Ship 2009
Activity# Port Date Activity - Description Deficiencies
7225207 WASHINGTON, District of Columbia Jun 14, 21 Incident Investigation - Agency Action Complete
7175126 ST PETERSBURG, Florida Apr 14, 21 Vessel Inspection - Approved Inspection
7175126 Tampa, Florida Apr 14, 21 Vessel Inspection - Approved Inspection
7008681 WASHINGTON, District of Columbia Jul 06, 20 Incident Investigation - Agency Action Complete
6963886 HOMER, Alaska May 23, 20 Vessel Inspection - Agency Action Complete
6958777 WASHINGTON, District of Columbia May 23, 20 Incident Investigation - Agency Action Complete
6942098 HOMER, Alaska Apr 21, 20 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
10 - Safety of NavigationN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
The M/T OVERSEAS BOSTON (ON 1207239, 576 FT, 29242 GT, Tanker) has a pin hole leak in the anchor windlass hydraulic system. The casualty prevents the vessel from weighing anchor until a piece of piping is repaired.Apr 21, 20Yes
Resolved DateResolution
Apr 22, 20Repair Completed.
6923795 San Pedro, California Mar 10, 20 Vessel Inspection - Approved Inspection
6890097 VALDEZ, Alaska Jan 13, 20 Facility Transfer Monitor - Agency Action Complete
6830772 WASHINGTON, District of Columbia Oct 04, 19 Incident Investigation - Agency Action Complete
6636023 WASHINGTON, District of Columbia Mar 02, 19 Incident Investigation - Agency Action Complete
6618065 San Pedro, California Feb 08, 19 Vessel Inspection - Approved Inspection
6392804 San Pedro, California Apr 20, 18 Vessel Inspection - Approved Inspection
6364377 JBER, Alaska Feb 13, 18 Vessel Inspection - Approved Inspection
6318958 VALDEZ, Alaska Dec 02, 17 Vessel Inspection - Agency Action Complete
6281139 Mobile, Alabama Sep 05, 17 Vessel Inspection - Approved Inspection
6215295 Houston, Texas May 17, 17 Vessel Inspection - Approved Inspection
6131417 Seattle, Washington Apr 26, 17 Vessel Inspection - Approved Inspection
6109750 Seattle, Washington Mar 23, 17 Boarding - Agency Action Complete
6077013 HOMER, Alaska Jan 23, 17 Vessel Inspection - Approved Inspection
6045606 Seattle, Washington Nov 19, 16 Vessel Operational Control - Agency Action Complete
6045552 WASHINGTON, District of Columbia Nov 19, 16 Incident Investigation - Agency Action Complete
6034634 Seattle, Washington Nov 02, 16 Vessel Inspection - Agency Action Complete
5946676 San Pedro, California Jul 20, 16 Vessel Transfer Monitor - Approved Inspection
5811434 VALDEZ, Alaska Feb 06, 16 Vessel Inspection - Agency Action Complete
5172744 San Pedro, California Jul 04, 15 Vessel Operational Control - Approved Inspection
5163495 HOMER, Alaska Jun 25, 15 Vessel Inspection - Agency Action Complete
5168808 HOMER, Alaska Jun 25, 15 Vessel Inspection - Agency Action Complete
5125068 JBER, Alaska May 18, 15 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
LifesavingInflatable Liferafts
DescriptionDue DateResolved
Provide liferafts with current servicing. 46CFR199.190(g)Yes
Resolved DateResolution
May 23, 15MSD Homer boarded vessel at anchor and verified loaner rafts are satisfactory.
5085102 HOMER, Alaska Mar 14, 15 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
EngineeringFuel Oil Service System
DescriptionDue DateResolved
1/8" crack on weld joint on the main engine fuel common header was discovered by crew members. Make permanent repairs to piping on main engine fuel common header.Mar 14, 15Yes
Resolved DateResolution
Mar 14, 15Vessel removed 1/2" schedule 40 drain pipe and replace with schedule 80 1/2" nipple. Witnessed sat die pen test, all sat.
5078903 HOMER, Alaska Mar 05, 15 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
NavigationCollision/Grounding Avoidance
DescriptionDue DateResolved
Repair inoperable 3cm RADAR prior to departure from Nikiski, AK.Mar 09, 15Yes
Resolved DateResolution
Mar 09, 15RADAR Repaired by technician and verified operational.
5039714 JBER, Alaska Dec 15, 14 Vessel Inspection - Agency Action Complete
4984999 WASHINGTON, District of Columbia Sep 16, 14 Incident Investigation - Agency Action Complete
4965981 Seattle, Washington Aug 25, 14 Facility Transfer Monitor - Agency Action Complete
4822654 San Francisco, California Mar 20, 14 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
EngineeringDiesel Engine (propulsion-direct drive)
DescriptionDue DateResolved
Provide report attesting to cause of fuel pump failures reported to Sectors LA/LB, San Fran, and Puget Sound (Feb-March). 46CFR31.10-25.May 05, 14Yes
Resolved DateResolution
May 01, 1401MAY13: Vessel switched to using only OEM fuel pump parts due to history of failures. Failure analysis no longer necessary.
4820679 WASHINGTON, District of Columbia Mar 20, 14 Incident Investigation - Agency Action Complete
4822739 San Francisco, California Mar 17, 14 Vessel Inspection - Approved Inspection
4817552 Seattle, Washington Mar 14, 14 Vessel Inspection - Agency Action Complete
4817908 WASHINGTON, District of Columbia Mar 14, 14 Incident Investigation - Agency Action Complete
4797426 San Pedro, California Feb 08, 14 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
EngineeringDiesel Engine (propulsion-direct drive)
DescriptionDue DateResolved
Battery back up for the electronic speed govener failed causing a loss of propulsion.Feb 08, 14Yes
Resolved DateResolution
Feb 08, 14Crew replaced battery back up and retined spares on board. Confirmed contorl from remote operating station, ahead and astern. All sat.
4815774 WASHINGTON, District of Columbia Feb 06, 14 Incident Investigation - Agency Action Complete
4776664 New Orleans, Louisiana Jan 02, 14 Vessel Inspection - Approved Inspection
4748087 Warrenton, Oregon Nov 05, 13 Enforcement - Agency Action Complete
4733239 Seattle, Washington Oct 11, 13 Vessel Inspection - Agency Action Complete
4596820 WASHINGTON, District of Columbia May 21, 13 Vessel Inspection - Approved Inspection
4590635 HOMER, Alaska May 13, 13 Vessel Inspection - Approved Inspection
4556736 HOMER, Alaska Mar 26, 13 Vessel Inspection - Approved Inspection
4516192 Seattle, Washington Jan 11, 13 Vessel Inspection - Agency Action Complete
4512081 WASHINGTON, District of Columbia Jan 02, 13 Incident Investigation - Agency Action Complete
4557777 WASHINGTON, District of Columbia Dec 28, 12 Incident Investigation - Agency Action Complete
4491611 HOMER, Alaska Nov 26, 12 Vessel Inspection - Approved Inspection
4357195 Seattle, Washington Jun 26, 12 Vessel Inspection - Approved Inspection
4312084 Homer, Alaska May 11, 12 Vessel Inspection - Approved Inspection
4240723 Seattle, Washington Feb 08, 12 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
EngineeringSteering Gear System
DescriptionDue DateResolved
During vessel UWILD divers were unable to remove access door for the lower pintle bearing. Vessel is in the ACP program, a work list item was issued to complete inspection at next available dock side no later than 09 April 2012. On 19 March 2012 Coast Guard received written request to defer final part of UWILD until NLT 30 April 2012. OCMI has allowed extension until then.Apr 30, 12Yes
Resolved DateResolution
Apr 28, 12ABS Class Surveyor attended vessel and cleared above CG 835.
4232606 Homer, Alaska Jan 25, 12 Vessel Inspection - Approved Inspection
4227856 Homer, Alaska Jan 19, 12 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
NavigationVoyage Data Recorder
DescriptionDue DateResolved
Replace/repair VDR.Jan 31, 12Yes
Resolved DateResolution
Jan 25, 12VDR repaired.
4213724 San Pedro, California Dec 25, 11 Vessel Operational Control - Approved Inspection
  1
SystemSubsystemCause
NavigationCollision/Grounding Avoidance
DescriptionDue DateResolved
24DEC2011 - Letter of Deviation issued due to an inoperable S.Band (10cm) Radar. Repairs to be completed in Port of Los Angeles / Long BeachYes
Resolved DateResolution
Dec 29, 11Received Tech Report attesting to repairs of Radar, and confirmation in good working order and worthy for Navigation.
4203997 Homer, Alaska Dec 07, 11 Vessel Inspection - Approved Inspection
4202259 Seattle, Washington Nov 28, 11 Vessel Inspection - Agency Action Complete
4200351 WASHINGTON, District of Columbia Nov 28, 11 Incident Investigation - Agency Action Complete
4232442 WASHINGTON, District of Columbia Oct 09, 11 Incident Investigation - Agency Action Complete
4163231 WASHINGTON, District of Columbia Oct 06, 11 Incident Investigation - Agency Action Complete
4087607 WASHINGTON, District of Columbia Jul 16, 11 Incident Investigation - Agency Action Complete
3962201 Homer, Alaska Mar 09, 11 Vessel Inspection - Approved Inspection
3960520 VALDEZ, Alaska Mar 07, 11 Facility Transfer Monitor - Agency Action Complete
3947227 Seattle, Washington Feb 17, 11 Vessel Inspection - Agency Action Complete
3947385 WASHINGTON, District of Columbia Feb 10, 11 Incident Investigation - Agency Action Complete
3925022 Homer, Alaska Jan 11, 11 Vessel Inspection - Approved Inspection
3895045 Seattle, Washington Nov 19, 10 Vessel Transfer Monitor - Approved Inspection
3892034 JBER, Alaska Nov 15, 10 Vessel Inspection - Approved Inspection
3853698 San Pedro, California Sep 16, 10 Vessel Inspection - Approved Inspection
3803676 Miami Beach, Florida Jul 23, 10 Vessel Inspection - Agency Action Complete
3767185 WASHINGTON, District of Columbia Jun 15, 10 Vessel Inspection - Approved Inspection
3749463 Honolulu, Hawaii May 27, 10 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Construction/LoadlineStructuresImproper Installation
DescriptionDue DateResolved
Make proper repairs for fractured weld located at frame 52-960 located near lower stool bottom plate and slope plate. Fractured weld is in located inside #6 cargo tank.Jun 04, 10Yes
Resolved DateResolution
Jun 04, 10
SystemSubsystemCause
EngineeringBilge Water Management SystemImproper Installation
DescriptionDue DateResolved
Vessel is not allowed to discharge decanted water ovbd. Prove proper operation of ODME to CG marine inspector at next US port.Jun 19, 10Yes
Resolved DateResolution
Jun 21, 10Verified to the satisfaction of attending marine inspector.
3714923 Homer, Alaska Apr 09, 10 Vessel Inspection - Agency Action Complete
3707099 WASHINGTON, District of Columbia Mar 30, 10 Incident Investigation - Agency Action Complete
3702306 Seattle, Washington Mar 23, 10 Vessel Inspection - Agency Action Complete
3701425 WASHINGTON, District of Columbia Mar 14, 10 Incident Investigation - Agency Action Complete
3692057 Homer, Alaska Mar 08, 10 Vessel Inspection - Agency Action Complete
3670319 VALDEZ, Alaska Jan 26, 10 Facility Transfer Monitor - Approved Inspection
3654684 Seattle, Washington Dec 23, 09 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Pollution Prevention/ResponsePrevention EquipmentUnknown
DescriptionDue DateResolved
Ship's crew found OWS inoperable during monthly check and reported to CGJan 22, 10Yes
Resolved DateResolution
Jan 05, 10Received Classification Report from ABS stating proper repairs have been made to the OWS and operational testing of the equipment was satisfactory to the attending surveyor.
3640525 San Francisco, California Nov 27, 09 Vessel Inspection - Approved Inspection
3579276 Homer, Alaska Aug 28, 09 Vessel Inspection - Agency Action Complete
3507501 Homer, Alaska Jun 18, 09 Vessel Inspection - Agency Action Complete
3474437 WASHINGTON, District of Columbia Apr 29, 09 Incident Investigation - Agency Action Complete
3450071 ST PETERSBURG, Florida Apr 10, 09 Vessel Inspection - Approved Inspection
3450071 Tampa, Florida Apr 10, 09 Vessel Inspection - Approved Inspection
3448305 San Pedro, California Apr 07, 09 Vessel Inspection - Approved Inspection
3439121 San Pedro, California Mar 24, 09 Boarding - Agency Action Complete
3437714 San Pedro, California Mar 21, 09 Vessel Operational Control - Agency Action Complete
3400733 PHILADELPHIA, Pennsylvania Jan 27, 09 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
Prior to operation of the incinerator show proper thermal capability (600 degree C with in first 5 minutes) to attending Coast Guard Marine Inspector.Yes
Resolved DateResolution
Apr 06, 09Witnessed satisfactory test of incinerator.
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
Provide paperwork / documents required for CG type approval for incinerator in accordance with MEPC 76(40) / MARPOL VI compliance to USCG Marine Safety Center, 1900 Half St SW Suite 1000, Rm 525 Washington DC 20593 with in 60 days.Apr 20, 09Yes
Resolved DateResolution
Apr 06, 09Received compliance documentation.
Documents Issued Expires Agency
CERTIFICATE OF DOCUMENTATION January 14,2021 February 28,2022 USCG
Certificate of Inspection February 8,2019 February 8,2024 USCG
Certificate of Inspection - Amended February 8,2019 February 8,2024 USCG
Classification Document February 19,2009 July 18,2009 N/A
International Certificate of Fitness - Chemical January 25,2014 February 18,2019 N/A
International Load Line Certificate January 25,2014 February 18,2019 N/A
International Oil Pollution Prevention Certificate January 25,2014 February 18,2019 N/A
ISM - Document Of Compliance September 14,2017 September 17,2022 ABS
ISM - Safety Management Certificate June 27,2019 July 11,2024 ABS
SOLAS Cargo Ship Safety Construction Certificate February 19,2009 June 18,2014 ABS
SOLAS Cargo Ship Safety Equipment Certificate February 19,2009 June 18,2014 ABS
SOLAS Cargo Ship Safety Radio Certificate September 8,2016 September 8,2017 N/A
Tonnage Certificate, International January 8,2009 ABS