Everbright
Print Q88   
IMO/VIN Callsign Flag Service Year
9408217 V7BH9 MARSHALL ISLANDS Tank Ship 2010
Activity# Port Date Activity - Description Deficiencies
6723758 Port Arthur, Texas Jun 28, 19 Vessel Inspection - Approved Inspection
6161598 Houston, Texas Jun 01, 17 Vessel Inspection - Approved Inspection
4900439 Lewes, Delaware Jun 29, 14 Vessel Inspection - Approved Inspection
  5
SystemSubsystemCause
DocumentationCertificates/Documents
DescriptionDue DateResolved
An IOPP shall be issued to any oil tanker 150 GT and above. The vessels IOPP does not mirror the rated throughput of the OWS manual.Jul 30, 14Yes
Resolved DateResolution
Jul 09, 14See attached Class report.
SystemSubsystemCause
DocumentationLogs/Records
DescriptionDue DateResolved
Operation shall be recorded w/o delay in ORB PT 1, entries in book appropriate to operation are completed. PSCO was provided a SL by CEng for JUN. Discrepancies between the figures recorded and ORB. 2JUN14 SL 36.85m3 in bilge holding tank, ORB 3JUN14 11.8m3 discharged overboard through OWS w/ 1.0m3 remaining. No record for 24m3 recorded in sounding. 14.5m3 remaining 4JUN vs. 1.0m3 in ORB.Yes
Resolved DateResolution
Jul 09, 14See attached Class report.
SystemSubsystemCause
Operations/ManagementBilge/Bilge System Management
DescriptionDue DateResolved
Ship subject to insp by auth concerning op req where grounds for believing that the Master/crew not familiar w/ shipboard procedures relating to the prev of pollution by oil. Chief/2Eng couldn’t demonstrate op of OWS. System op was demonstrated to PSCO w/o sample prov to the OCM. Crew unable to demonstrate op after efforts despite OWS oper logged 3 days prior. Op 3 way valve couldn’t demonstrated.Yes
Resolved DateResolution
Jul 09, 14See attached Class report.
SystemSubsystemCause
DocumentationSafety Management System
DescriptionDue DateResolved
SMS IAW ISM. Company should implement & maintain SMS watch includes safety & environ-protection policy. Policy is implemented & maintained all levels of org, ship & shore based. SMS states soundings conducted daily & recorded in a logbook/computer. Not being implemented by crew. Ships maint shall be recorded in the PMS computer program. OWS maint was logged in ORB not PMS. ISM audit recommended.Yes
Resolved DateResolution
Jul 09, 14See attached Class report.
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
The cond of the equipment shall be maint to conform with the convention to ensure that the ship will remain fit to proceed to sea w/o presenting harm to the env. The OWS was operated with the sample line to the OCM closed. Once the sample line opened, the oil content rose above 15PPM then to 0PPM. The 3 way valve did not change positions from recirculation. The OWS could not be properly operated.Yes
Resolved DateResolution
Jul 09, 14See attached Class report.
4903904 PHILADELPHIA, Pennsylvania Jun 29, 14 Boarding - Agency Action Complete
4898625 PHILADELPHIA, Pennsylvania Jun 24, 14 Vessel Operational Control - Agency Action Complete
4519075 New Orleans, Louisiana Jan 19, 13 Vessel Inspection - Administrative Action
4512543 TEXAS CITY, Texas Jan 14, 13 Vessel Inspection - Approved Inspection
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel June 28,2019 June 28,2021 N/A
Classification Document March 27,2018 March 18,2020 DNV GL
COC-TVE Renewal June 29,2014 June 29,2016 N/A
International Load Line Certificate March 27,2018 March 18,2020 DNV GL
International Oil Pollution Prevention Certificate March 27,2018 March 18,2020 DNV GL
ISM - Document Of Compliance June 21,2018 July 23,2023 LR
ISM - Safety Management Certificate October 6,2011 July 13,2015 N/A
Minimum Safe Manning Document August 26,2015 MH
SOLAS Cargo Ship Safety Construction Certificate March 27,2018 March 18,2020 DNV GL
SOLAS Cargo Ship Safety Equipment Certificate March 27,2018 March 18,2020 DNV GL
SOLAS Cargo Ship Safety Radio Certificate April 15,2019 March 18,2020 DNV GL
Tonnage Certificate, International August 28,2013 DNV GL