Bw Hudson
Print Q88   
IMO/VIN Callsign Flag Service Year
9324306 9V2881 SINGAPORE Tank Ship 2007
Activity# Port Date Activity - Description Deficiencies
6656201 WASHINGTON, District of Columbia Apr 05, 19 Incident Investigation - Agency Action Complete
6655613 CORPUS CHRISTI, Texas Apr 04, 19 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
02 - Structural ConditionsN/A - No Subsystem
DescriptionDue DateResolved
A ship which is designed, constructed and maintained in compliance with the appropriate requirements of an organization including a classification society, which is recognized by the Administration or with applicable national standards of the Administration in accordance with the provisions of regulation 2-1, may be considered to provide an acceptable level of strength. The above provisions shall apply to all structures, equipment, and fittings covered by this annex for which standards for strength and construction are not expressly provided. On 04 APR 2019 at approximately 0558 while mooring at Buckeye Dock 3, the vessel allided with the dolphin pier tie off, forward starboard side way of number one ballast tank. Puncture approximately 1 foot by 3 inch approximate 8 feet above the water line. Vessel restricted in movement to inner harbor until classification survey is complete. ICLL (88) Annex B/Reg 1.2Yes
Resolved DateResolution
Apr 07, 19Received class report attesting to the permenant repair of the puncture on the stbd side shell plating.
6652943 CORPUS CHRISTI, Texas Mar 31, 19 Vessel Inspection - Administrative Action
6603107 STATEN ISLAND, New York Dec 29, 18 Vessel Inspection - Approved Inspection
5929220 New Orleans, Louisiana Jul 06, 16 Vessel Inspection - Approved Inspection
  4
SystemSubsystemCause
LifesavingLifeboatImproper/Lack of Maintenance
DescriptionDue DateResolved
0610- Lifeboats- A lifeboat which has a water spray fire-protection system shall comply with the following: the system shall be arranged for flushing with fresh water and allowing complete drainage. Crew was unable to provide means to flush with fresh water. SOLAS 74/78 III/34, LSA Code 4.9.2.3Jul 20, 16Yes
Resolved DateResolution
Jul 12, 16Received class report from DNV stating deficiency has been cleared.
SystemSubsystemCause
Construction/LoadlineMarkingsImproper/Lack of Maintenance
DescriptionDue DateResolved
1220- Freeboard Marks- The ring lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. PSCO observed freeboard lines on the port side were not appropriatly painted. ICLL 66 as modified Annex I/8 Rectify prior to next U.S. Port after sailing foreign.Jul 06, 16Yes
Resolved DateResolution
Mar 31, 19Vessel provided documentation that the deficiency had been cleared by Sector New Orleans via their CG-5437B from 29DEC2018. This document is attached to this activity for reference.
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
1899- Other (tankers)- Each cargo tank of a tank ship must be equipped with an intrinsically safe high level alarm and overfill alarm. PSCO observed audible alarm for overfill not sounding on deck. Crew cleaned air line and tested alarms satisfactorily. 46 CFR 39.2007Jul 06, 16Yes
Resolved DateResolution
Jul 06, 16Crew cleaned air line and tested alarms to PSCO satisfaction.
SystemSubsystemCause
Operations/ManagementDrills/InstructionImproper/Lack of Maintenance
DescriptionDue DateResolved
2099- Other SOlas Operational Def.- Crew members with enclosed space entry or rescue responsibilities shall participate in an enclosed space entry and rescue drill to be held on board the ship at least every two months. The crew has not completed an enclosed space rescue drill withinn two months (April 25, 2016) SOLAS 74/78 III/19.3.3Jul 06, 16Yes
Resolved DateResolution
Jul 06, 16PSCO witnessed satisfactory Enclosed Space Entry and Rescue Drill during examination.
5038335 STATEN ISLAND, New York Dec 12, 14 Vessel Inspection - Approved Inspection
4638612 New Orleans, Louisiana Jul 09, 13 Vessel Inspection - Approved Inspection
4214444 New Orleans, Louisiana Dec 27, 11 Vessel Inspection - Administrative Action
4211603 New Orleans, Louisiana Dec 20, 11 Vessel Inspection - Administrative Action
4191821 New Orleans, Louisiana Nov 28, 11 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
ElectricalElectrical Distribution System (service)
DescriptionDue DateResolved
0950-Elec. Equip. in Gen.-Where which are installed in hazardous areas introduce the risk of fire or explosion in the event of electrical fault in such areas, special precautions shall be taken. Electrical junction boxes at cargo tanks 3, 5 and 6 port side are fractured. Provide documentation from the class attesting to the sat arrangements of the electrical junction boxes.-SOLAS 74a II-1/45Nov 28, 11Yes
Resolved DateResolution
Dec 20, 11Received class report from American Bureau of Shipping satisfying requirement.
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
2199-Other MARPOL- Any discharge of oil from the cargo area shall not exceed 30 l/nautical mile. PSCO observed a 1 foot by 5 feet spray of crude oil on the port side of the ship originating from the ODME overboard discharge. Clean ODME line and side of the ship to the satisfaction of class. Provide a corrective action plan from the company with concurrence from the administration. MARPOL I/34Nov 28, 11Yes
Resolved DateResolution
Dec 04, 11Received, reviewed and accepted class report from ABS with flag concurrence stating the ODME overboard discharge line and side of vessel was cleaned, examined and found satisfactory.
4168454 PHILADELPHIA, Pennsylvania Oct 15, 11 Vessel Inspection - Approved Inspection
4080848 Woods Hole, Massachusetts Jul 14, 11 Vessel Inspection - Approved Inspection
4038944 PHILADELPHIA, Pennsylvania Jun 09, 11 Vessel Inspection - Approved Inspection
3876024 Lewes, Delaware Oct 23, 10 Vessel Inspection - Approved Inspection
3880573 PHILADELPHIA, Pennsylvania Oct 22, 10 Boarding - Agency Action Complete
3874047 PHILADELPHIA, Pennsylvania Oct 20, 10 Vessel Operational Control - Agency Action Complete
3214597 STATEN ISLAND, New York May 24, 08 Vessel Inspection - Approved Inspection
  3
SystemSubsystemCause
Deck/CargoCargo Stowage
DescriptionDue DateResolved
Oxygen levels in slop starboard and slop port tanks carrying cargo (unleaded gasoline) are at 9.2% and 10.8%. Bring oxygen content in all cargo tanks to no more than 8% by volume. Rectify prior to movement. FSS Code Ch. 15 2.1.3.2Yes
Resolved DateResolution
May 24, 08IGS system brought online, delivered oxygen content of 3.9%. All cargo tanks at or less than 6% by volume.
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational Safety
DescriptionDue DateResolved
Remove wooden decks in way of gangways to center catwalk from both port and stbd sides. The wooden decks are deteriorating. Have this completed prior to next US port after sailing foreign to the satisfaction of Class.Yes
Resolved DateResolution
May 24, 08Crew removed wooden decks on both sides of vessel. No need for Class to examine. All in satisfactory condition. Deficiency cleared by PSCO.
SystemSubsystemCause
NavigationPiloting/Steering
DescriptionDue DateResolved
US Coast Pilot not onboard vessel. Receipt for purchase of US Coast Pilot must be faxed to USCG prior to departure. 33 CFR 164.33Yes
Resolved DateResolution
May 24, 08Received receipt for US Coast Pilot via fax from agent.
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel July 9,2013 July 9,2014 NEWMS
Classification Document June 24,2012 June 11,2017 ABS
COC-TVE Annual November 28,2011 October 23,2012 NEWMS
COC-TVE Renewal October 23,2010 October 23,2012 N/A
International Load Line Certificate July 25,2014 June 11,2017 DNV GL
International Oil Pollution Prevention Certificate June 24,2012 June 11,2017 ABS
ISM - Document Of Compliance June 3,2016 June 7,2021 LR
ISM - Safety Management Certificate September 15,2012 November 2,2017 ABS
Minimum Safe Manning Document September 3,2014 SG
SOLAS Cargo Ship Safety Construction Certificate June 24,2012 June 11,2017 ABS
SOLAS Cargo Ship Safety Equipment Certificate June 24,2012 June 11,2017 ABS
SOLAS Cargo Ship Safety Radio Certificate June 24,2012 June 11,2017 ABS
Tonnage Certificate, International April 27,2015 DNV GL