Torm Arawa
Print Q88   
IMO/VIN Callsign Flag Service Year
9543548 9V9636 SINGAPORE Tank Ship 2012
Activity# Port Date Activity - Description Deficiencies
7126054 San Pedro, California Jan 17, 21 Boarding - Agency Action Complete
7037176 Houston, Texas Aug 28, 20 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
15 - Safety Management Systems (ISM)N/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
The company should ensure that any non-conformity is reported, with its possible cause, if known. PSCO observed auxiliary air receiver relief valve was wire tied to prevent the release of compressed air. Last internal inspection from SMS was 12 March 2020. There were no defect job reports made for this instance as required in ships procedures.Aug 28, 20Yes
Resolved DateResolution
Aug 28, 20Removed the wire from the valve and created a defect job report.
SystemSubsystemCause
09 - Working and Living Conditions092 - Working ConditionsImproper/Lack of Maintenance
DescriptionDue DateResolved
Where main or auxiliary machinery including pressure vessels or any parts of such machinery are subject to internal pressure and may be subject to dangerous overpressure, means shall be provided where practicable to protect against such excessive pressure. PSCO observed wire wrapped around safety valve handle of aux air receiver within the vicinity of start air compressors. Crew stated this was added because excessive vibration was causing unintended activation of the safety valve. Wire was removed and no unintended release happened.Aug 28, 20Yes
Resolved DateResolution
Aug 28, 20Removed the wire from the valve and created a defect job report.
7035403 Houston, Texas Aug 17, 20 Vessel Inspection - Approved Inspection
6706879 San Pedro, California Jun 10, 19 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
11 - Life Saving AppliancesN/A - No Subsystem
DescriptionDue DateResolved
Cite: 74SOLAS(14)II/20.2 / Code: 11118 / Action: 40ac before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO discovered that approximately 50 percent of the lifejackets on board the ship and internal buoyant material visibly showing due to the type of light that was inserted into the lifejacket.Yes
Resolved DateResolution
Aug 17, 20Vessel provided pictures and class correspondence that 50% of lifejackets have been renewed.
6296603 New Orleans, Louisiana Oct 28, 17 Vessel Inspection - Approved Inspection
6292580 STATEN ISLAND, New York Oct 22, 17 Vessel Inspection - Approved Inspection
6292346 STATEN ISLAND, New York Oct 21, 17 Boarding - Agency Action Complete
6290841 STATEN ISLAND, New York Oct 19, 17 Vessel Operational Control - Agency Action Complete
6290826 STATEN ISLAND, New York Oct 19, 17 Vessel Operational Control - Agency Action Complete
5873378 San Juan, Puerto Rico May 13, 16 Vessel Inspection - Approved Inspection
5126022 New Orleans, Louisiana May 19, 15 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Fire FightingFixed CO2 Fire Extinguishing System
DescriptionDue DateResolved
0799 - FF Other - The means of control of fixed gas fire-extinguishing system shall be simple to operate and shall be grouped together in as few locations as possible. At each location there shall be clear instructions relating to the operation of the system. The local release instructions do not correspond to the local release mechanism. - 74 SOLAS (am) II-2/4; FSS Code 5.2.1.3.2.May 22, 15Yes
Resolved DateResolution
May 23, 15Received, reviewed and accepted class report from DNV-GL stating the deficiency was rectified. Vessel relabled CO2 control valves and posted instructions accurately reflecting new labels.
5090694 WASHINGTON, District of Columbia Mar 25, 15 Incident Investigation - Agency Action Complete
4854397 STATEN ISLAND, New York May 10, 14 Vessel Inspection - Approved Inspection
4607249 TEXAS CITY, Texas Jun 05, 13 Vessel Inspection - Approved Inspection
4290259 New Orleans, Louisiana Apr 19, 12 Enforcement - Agency Action Complete
4264365 WASHINGTON, District of Columbia Mar 14, 12 Incident Investigation - Agency Action Complete
4255639 New Orleans, Louisiana Mar 10, 12 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Deck/CargoInert Gas System
DescriptionDue DateResolved
1850- Fire Protection Cargo Deck Area- During operation of the IGS, the scrubber saltwater supply pipe sprayed saltwater from three separate flange joints. Provide report from RO attesting to proper operation and structural integrity of the scrubber saltwater supply system. Prohibited from conducting cargo ops requiring IG in U.S. waters until the IGS is tested by USCG- SOLAS 74(a) 09cons II-2/4Mar 10, 12Yes
Resolved DateResolution
Mar 12, 12Received, reviewed, and accepted class report from Det Norske Veritas stating the outstanding deficiency was rectified. The report stated that all gaskets were renewed and system was tested to the satisfaction of the class surveyor.
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel May 13,2016 May 13,2018 N/A
Certificate of Fitness - Chemical Carrier August 28,2017 January 13,2022 N/A
Classification Document December 26,2017 January 13,2022 DNV
International Certificate of Fitness - Chemical January 13,2012 June 13,2012 DNV
International Load Line Certificate January 13,2012 June 13,2012 DNV
International Oil Pollution Prevention Certificate June 15,2017 June 15,2022 DNV
ISM - Document Of Compliance April 20,2018 May 1,2023 LR
ISM - Safety Management Certificate January 13,2012 July 12,2012 LR
Minimum Safe Manning Document February 13,2019 SG
SOLAS Cargo Ship Safety Construction Certificate January 13,2012 June 13,2012 DNV
SOLAS Cargo Ship Safety Equipment Certificate January 13,2012 June 13,2012 DNV
SOLAS Cargo Ship Safety Radio Certificate January 13,2012 June 13,2012 DNV
Tonnage Certificate, International September 25,2019 DNV
Tonnage Certificate, U.S. November 21,2011 DNV