Fenno Swan
Print Q88   
IMO/VIN Callsign Flag Service Year
9390331 9HLI9 MALTA Tank Ship 2008
Activity# Port Date Activity - Description Deficiencies
7118074 Savannah, Georgia Jan 03, 21 Vessel Inspection - Agency Action Complete
  1   1
SystemSubsystemCause
10 - Safety of NavigationN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
The angular position of the rudder shall be indicated on the navigation bridge. Rudder angle indicators could not display rudder angle past 20 degrees starboard. SOLAS (2004) CH II-1 Reg 29.11.1Yes
Resolved DateResolution
Jan 04, 21Class issued short term safe equipment cert to expire 31JAN2021 due to part availbility.
SystemSubsystemCause
02 - Structural ConditionsN/A - No SubsystemInvalid
DescriptionDue DateResolved
Vessel must have an installed CG approved BWMS or AMS to discharge ballast water into the waters of the United States. Vessel's BW extension expired on 01JUN19 and a system was not installed. Vessel cannot discharge ballast water into water's of the US unless they employ a method as per 33CFR151.2025(a)(2),(4) and (5). 33CFR151.2035No
6680542 Mobile, Alabama May 09, 19 Vessel Inspection - Approved Inspection
6650642 Mobile, Alabama Mar 27, 19 Vessel Inspection - Approved Inspection
6643843 Mobile, Alabama Mar 26, 19 Vessel Inspection - Approved Inspection
  2   1
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No Subsystem
DescriptionDue DateResolved
06107- Where inerting or padding of cargo tanks is required by the International Bulk Chemical (IBC) Code the vessel shall have an adequate supply of inert gas for use. The crew was unable to operate and test the alarms/indicators required for the installed nitrogen generator system in accorance with the FSS Code. SOLAS 74(14)VII/10 IBC CODE 9.1.3Yes
Resolved DateResolution
Mar 27, 19Multiple alarms were tested for the N2 Generator which were found to operating as per manufacturer's specifications.
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No Subsystem
DescriptionDue DateResolved
06199- The transfer procedures must contain either in order listed or by use of a cross-reference index page in accordance with 33 CFR 155.750. Crew was unable to provide transfer procedures meeting the requirements of 33 CFR 155.750.No
SystemSubsystemCause
13 - Propulsion and Auxiliary MachineryN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
13101-Connections within the fuel supply and spill lines shall be constructed having regard to their ability to prevent pressurized oil fuel leaks while in service and after maintenance. PSCO noted multiple leaks on main engine high pressure fuel lines. SOLAS 74(04 CONS.) II-2/4.2.2.5.4Yes
Resolved DateResolution
Mar 27, 19The ship's crew renewed all O-Rings on high pressure fuel lines. After completion of repairs, the main engine was operationally tested with no apparent leaks detected.
6643846 Mobile, Alabama Mar 17, 19 Vessel Inspection - Approved Inspection
5844988 STATEN ISLAND, New York Apr 01, 16 Vessel Inspection - Agency Action Complete
5824638 Houma, Louisiana Mar 01, 16 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Deck/CargoVapor Control SystemsImproper Installation
DescriptionDue DateResolved
1835 - VCS - VAPOR CONNECTION FLANGE MUST HAVE A PERMANENT STUD PROJECTING OUTWARD THAT HAS A 12.7 mm DIATEMTER AND IS AT LEAST 25.4 mm LONG. VAPOR CONNECTION FLANGE STUD IS NOT PERMANENTLY AFFIXED. VESSEL MUST PROVIDE EVIDENCE OF PROPER REPAIR PRIOR TO LOADING CARGOES REQUIRING VAPOR CONTROL IN THE UNITED STATES. -46 CFR 39.2001 (j)Mar 01, 16Yes
Resolved DateResolution
Mar 04, 16Received and verified proof of permanant installation of stud.
4756889 Houston, Texas Nov 29, 13 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Deck/CargoCargo Stowage
DescriptionDue DateResolved
1099-TANK OVERFILL AUDIBLE & VISUAL ALARM NOT WORKING PROPERLY FOR #5 STARBOARD TANK. 46CFR39.20-7(d)(2)Nov 29, 13Yes
Resolved DateResolution
Dec 01, 13Received, reviewed and accepted class report documentation from GL class.
4760684 TEXAS CITY, Texas Nov 28, 13 Boarding - Agency Action Complete
3880640 Port Arthur, Texas Nov 03, 10 Vessel Inspection - Approved Inspection
Documents Issued Expires Agency
Certificate of Fitness - Chemical Carrier August 13,2015 April 20,2018 BV
Classification Document December 23,2020 April 20,2023 BV
International Certificate of Fitness - Chemical December 23,2020 April 20,2023 BV
International Load Line Certificate April 20,2018 April 20,2023 BV
International Oil Pollution Prevention Certificate April 20,2018 April 20,2023 BV
ISM - Document Of Compliance September 23,2016 October 4,2021 N/A
ISM - Safety Management Certificate October 27,2008 October 26,2013 LR
Minimum Safe Manning Document November 28,2019 April 20,2023 MT
NLS Certificate June 13,2008 April 20,2013 BV
SOLAS Cargo Ship Safety Construction Certificate April 20,2018 April 20,2023 BV
SOLAS Cargo Ship Safety Equipment Certificate April 20,2018 April 20,2023 BV
SOLAS Cargo Ship Safety Radio Certificate June 13,2008 April 30,2011 BV
Tonnage Certificate, International May 28,2013 GL