RCM 225
Print Q88   
IMO/VIN Callsign Flag Service Year
1139764 WDM9210 UNITED STATES Tank Barge 2003
Activity# Port Date Activity - Description Deficiencies
7457925 STATEN ISLAND, New York May 24, 22 Vessel Inspection - Administrative Action
7438699 STATEN ISLAND, New York Apr 28, 22 Vessel Inspection - Approved Inspection
7128472 STATEN ISLAND, New York Jan 22, 21 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
01 - Certificates & Documentation011 - Ships CertificatesInvalid
DescriptionDue DateResolved
Certificates of Inspection will be issued for a period of 5 years; COI deactivated on 21JAN21 due to missed periodic inspection. Complete COI Inspection prior to conducting cargo operations.May 18, 23Yes
Resolved DateResolution
Mar 24, 22Conducted inspection for certification.
6813713 STATEN ISLAND, New York Sep 17, 19 Vessel Inspection - Approved Inspection
  4
SystemSubsystemCause
09 - Working and Living Conditions092 - Working ConditionsDamaged By Earlier Event
DescriptionDue DateResolved
Generator room has 110v f/o alarm panel that has the visual indicator lighting that was punched out and could allow a person access to the wiring within. 46 CFR 111.01(a)(2)Oct 01, 19Yes
Resolved DateResolution
Oct 29, 19Lights were re-installed and covered. All Sat
SystemSubsystemCause
09 - Working and Living Conditions092 - Working ConditionsDamaged By Earlier Event
DescriptionDue DateResolved
Generator room has the hydraulic 440V pnl with a door that does not close. 46 CFR 111.01(a)(2)Oct 01, 19Yes
Resolved DateResolution
Oct 29, 19New latch mech was installed and verified.
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No Subsystem
DescriptionDue DateResolved
Vapor trunks from the cargo pump to the pump room had holes and were missing the band clamps making them not vapor tight. 46 CFR 111.105-31(k)(1)Oct 01, 19Yes
Resolved DateResolution
Oct 29, 19Vapor trunks were replaced with new along with clamps
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No Subsystem
DescriptionDue DateResolved
Vessel has leaking closed gauging windows on tanks 1-7P and 2,3,4,5,7 stbd. Closed gauging was rtv'd shut. 46 CFR 151.15-10(c)Oct 01, 19Yes
Resolved DateResolution
Oct 29, 19Replaced all gaskets on the closed gauging system. Conducted a pressure test @1.5 psi. Verified no pressure drop and that sightglass did not bubble when soapy solution was applied.
6436545 STATEN ISLAND, New York Jun 07, 18 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
09 - Working and Living Conditions092 - Working ConditionsImproper/Lack of Maintenance
DescriptionDue DateResolved
There must be ground detection for each: (b) Ship's power service system. Faulty ground detection noted on the 120V system. O/O to mitigate deficiency accordingly.Aug 03, 18Yes
Resolved DateResolution
Nov 20, 18Follow up conducted w/Owner-Operator and system is functioning to the satisfaction of the Marine Inspector.
6405763 STATEN ISLAND, New York Jan 10, 18 Vessel Inspection - Approved Inspection
  8
SystemSubsystemCause
Deck/CargoHolds/Tanks
DescriptionDue DateResolved
#3S cargo tank P/V valve had plug in the place of drain.Yes
Resolved DateResolution
Jan 11, 18Replaced plug with drain fitting with new flame screen.
SystemSubsystemCause
ElectricalElectrical Distribution System (service)
DescriptionDue DateResolved
120V and 240V panels in generator room are missing breaker covers.Jan 17, 18Yes
Resolved DateResolution
Jan 11, 18Covers were installed.
SystemSubsystemCause
DocumentationLogs/Records
DescriptionDue DateResolved
Abandon ship drills and fire fighting drills were not properly logged. Barge Captain was using company drill schedule and record sheets, however these drills were being documented and incorporated into other drill-types, and not as separate drills and individual items on the log.Jan 10, 18Yes
Resolved DateResolution
Jan 10, 18Onboard training was conducted.
SystemSubsystemCause
Deck/CargoHolds/Tanks
DescriptionDue DateResolved
Fwd rake entrance is within haz zone. Entrance has open wire runs that impede vapor tightness.Yes
Resolved DateResolution
Jan 11, 18Wire runs were sealed.
SystemSubsystemCause
ElectricalElectrical Distribution System (service)
DescriptionDue DateResolved
Ground detection for 120V system in not functioning.Jan 17, 18Yes
Resolved DateResolution
Jan 11, 18Indicated ground was eliminated.
SystemSubsystemCause
LifesavingLifebuoys
DescriptionDue DateResolved
Life rings not properly marked with name of vessel and hailing port.Feb 10, 18Yes
Resolved DateResolution
Jan 11, 18Markings were stenciled on.
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
Spare hoses at manifold need blank flanges and to be tested prior to use.Jan 11, 18Yes
Resolved DateResolution
Jan 11, 18Hoses were removed from the barge.
SystemSubsystemCause
Construction/LoadlinePenetrations
DescriptionDue DateResolved
The gaskets on port and starboard aft rake hatches are not continuous.Jan 17, 18Yes
Resolved DateResolution
Jan 11, 18Gaskets were replaced.
6150375 STATEN ISLAND, New York May 13, 17 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Construction/LoadlineStructuresDamaged By Earlier Event
DescriptionDue DateResolved
C/R sideshell plating IWO canted frame C to anchor slide PS forepeak; approx. 8-10 ft. by 12-15 ft. section to the satisfaction of the attending CG marine inspector. Vessel is allowed to discharge all cargo, then proceed to do repair to the satisfaction of the attending CG marine inspector. Prior to each movement contact the CG Sector NY Command Center at (718) 354-4353.Yes
Resolved DateResolution
May 23, 17Inspected final repair, found satisfactory.
6048560 BOSTON, Massachusetts Nov 28, 16 Vessel Transfer Monitor - Approved Inspection
5914007 STATEN ISLAND, New York Jun 23, 16 Vessel Inspection - Approved Inspection
5794891 BOSTON, Massachusetts Jan 11, 16 Vessel Transfer Monitor - Approved Inspection
5099576 ST PETERSBURG, Florida Apr 10, 15 Vessel Inspection - Agency Action Complete
5099576 Tampa, Florida Apr 10, 15 Vessel Inspection - Agency Action Complete
4984056 STATEN ISLAND, New York Sep 15, 14 Vessel Inspection - Agency Action Complete
4951429 Miami Beach, Florida Aug 12, 14 Vessel Inspection - Approved Inspection
  5
SystemSubsystemCause
Fire FightingMiscellaneous Items
DescriptionDue DateResolved
Properly stow all flam liquids, paint, and used batteries from the machinery spaces and decks.Aug 13, 14Yes
Resolved DateResolution
Aug 13, 14
SystemSubsystemCause
ElectricalElectrical Distribution System (service)
DescriptionDue DateResolved
Remove extension cord providing power to chest freezers in the stbd pump room.Aug 13, 14Yes
Resolved DateResolution
Aug 13, 14
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
Repair fuel leak on #2 cargo pump prime mover IWO fuel filter.Aug 13, 14Yes
Resolved DateResolution
Aug 13, 14
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
Repair oil leak on #2 cargo pump prime mover oil cooler IWO after cooler.Aug 19, 14Yes
Resolved DateResolution
Aug 19, 14
SystemSubsystemCause
DocumentationCertificates/Documents
DescriptionDue DateResolved
Vessel is not to carry more than 2 persons as permitted on the COI. Contact CG Sector St Pete to de-conflict the COI manning with actual operations.Aug 13, 14Yes
Resolved DateResolution
Sep 15, 14Sector new York amending COI to reflect change in manning.
4617370 STATEN ISLAND, New York Jun 10, 13 Vessel Inspection - Agency Action Complete
  3
SystemSubsystemCause
Deck/CargoVapor Control Systems
DescriptionDue DateResolved
All four Vapor Control connection piping was not properly painted/color coated. 46 CFR 39.20-1Jul 05, 13Yes
Resolved DateResolution
Jun 24, 13Crewmembers onboard the vessel painted all four vapor control lines.
SystemSubsystemCause
ElectricalElectric Generation Source (service)
DescriptionDue DateResolved
House genereator was inoperable and not ready for inspection. 46. CFR 111.12Jul 31, 13Yes
Resolved DateResolution
Jul 16, 13Operated the vessel''s house generator and tested the over speed and lube oil pressure safety trips. test was all satisfactory.
SystemSubsystemCause
LifesavingLine-Throwing Appliances
DescriptionDue DateResolved
Line throwing gun not onboard the during the COI examing. 46 CFR 199.170Jul 05, 13Yes
Resolved DateResolution
Jun 21, 13Vessel brought on a valid Line Throwing gun prior to coast guard inspectors departing the vessel.
4388963 STATEN ISLAND, New York Jul 24, 12 Vessel Inspection - Agency Action Complete
4375446 STATEN ISLAND, New York Jul 11, 12 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
Replace seals in between pump house and cargo (hazardous) area to maintain Class I, Div I divisions. (Prior to carriage of cargo w/ flash point 140F ir below)Aug 11, 12Yes
Resolved DateResolution
Jul 24, 12Rcvd proof of replacement
4260321 WASHINGTON, District of Columbia Mar 09, 12 Incident Investigation - Agency Action Complete
4035899 STATEN ISLAND, New York Jun 01, 11 Vessel Inspection - Agency Action Complete
3938278 STATEN ISLAND, New York Feb 03, 11 Vessel Transfer Monitor - Approved Inspection
3917313 WASHINGTON, District of Columbia Dec 27, 10 Incident Investigation - Agency Action Complete
3864661 NEW HAVEN, Connecticut Oct 06, 10 Vessel Transfer Monitor - Agency Action Complete
3767858 STATEN ISLAND, New York Jun 16, 10 Vessel Inspection - Agency Action Complete
3720453 NEW HAVEN, Connecticut Apr 20, 10 Vessel Inspection - Approved Inspection
3719899 NEW HAVEN, Connecticut Apr 19, 10 Vessel Transfer Monitor - Agency Action Complete
3658856 NEW HAVEN, Connecticut Jan 05, 10 Vessel Inspection - Agency Action Complete
3654071 STATEN ISLAND, New York Dec 22, 09 Vessel Inspection - Agency Action Complete
3652517 NEW HAVEN, Connecticut Dec 18, 09 Vessel Transfer Monitor - Agency Action Complete
3627628 WASHINGTON, District of Columbia Oct 14, 09 Incident Investigation - Agency Action Complete
3527574 WASHINGTON, District of Columbia Jul 07, 09 Incident Investigation - Agency Action Complete
3514424 STATEN ISLAND, New York Jun 26, 09 Vessel Inspection - Agency Action Complete
3453870 WASHINGTON, District of Columbia Apr 08, 09 Incident Investigation - Agency Action Complete
3447809 STATEN ISLAND, New York Apr 07, 09 Vessel Inspection - Agency Action Complete
3295961 NEW HAVEN, Connecticut Aug 11, 08 Vessel Transfer Monitor - Agency Action Complete
3221661 STATEN ISLAND, New York May 29, 08 Vessel Inspection - Agency Action Complete
3207160 NEW HAVEN, Connecticut May 15, 08 Vessel Transfer Monitor - Agency Action Complete
3147076 WASHINGTON, District of Columbia Feb 13, 08 Incident Investigation - Agency Action Complete
3021782 STATEN ISLAND, New York Aug 09, 07 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
Prove operation of visual alarm for overfill protection systemSep 09, 07Yes
Resolved DateResolution
Aug 10, 07Recieved tech report stating that overfill alarm is in proper working order.
2888473 STATEN ISLAND, New York Mar 15, 07 Facility Transfer Monitor - Approved Inspection
2743862 Washington, District of Columbia Aug 11, 06 Vessel Inspection - Security Plan Approved by MSC
2656450 STATEN ISLAND, New York May 23, 06 Vessel Inspection - Approved Inspection
2634954 STATEN ISLAND, New York Apr 27, 06 Vessel Transfer Monitor - Approved Inspection
2603050 Washington, District of Columbia Mar 15, 06 Vessel Inspection - Security Plan Approved by MSC
2578883 Washington, District of Columbia Feb 03, 06 Vessel Inspection - Administrative Action
2384524 STATEN ISLAND, New York Jun 09, 05 Vessel Inspection - Agency Action Complete
2309849 Washington, District of Columbia Mar 14, 05 Vessel Inspection - Security Plan Approved by MSC
2274042 Woods Hole, Massachusetts Jan 12, 05 Vessel Transfer Monitor - Approved Inspection
2241230 GRETNA, Louisiana Nov 15, 04 Vessel Inspection - Approved Inspection
2140226 STATEN ISLAND, New York Jul 21, 04 Vessel Inspection - Approved Inspection
2147892 Woods Hole, Massachusetts Jul 19, 04 Vessel Transfer Monitor - Approved Inspection
2080664 Washington, District of Columbia May 28, 04 Vessel Inspection - Security Plan Approved by MSC
1962413 Washington, District of Columbia Dec 09, 03 Vessel Inspection - ASP Criteria Met
1925402 NEW HAVEN, Connecticut Oct 10, 03 Vessel Transfer Monitor - Agency Action Complete
1797328 New Orleans, Louisiana May 20, 03 Vessel Inspection - Approved Inspection
  3
SystemSubsystemCause
Pollution Prevention/Response
DescriptionDue DateResolved
Porvide SOPEPJun 30, 03Yes
Resolved DateResolution
Jun 10, 03
SystemSubsystemCause
Deck/Cargo
DescriptionDue DateResolved
Provide Cargo Authority Authorization.Jun 30, 03Yes
Resolved DateResolution
Jun 05, 03
SystemSubsystemCause
Pollution Prevention/Response
DescriptionDue DateResolved
Provide Certificate of Financial ResponsibilityYes
Resolved DateResolution
Jun 10, 03
Documents Issued Expires Agency
Cargo Authority Attachment January 9,2009 N/A
CERTIFICATE OF DOCUMENTATION August 23,2021 August 31,2022 USCG
Certificate of Inspection May 30,2003 May 30,2008 N/A
Certificate of Inspection - Amended May 30,2003 May 30,2008 N/A
Classification Document May 30,2008 May 30,2013 N/A
International Load Line Certificate May 30,2008 May 30,2013 N/A
International Oil Pollution Prevention Certificate November 15,2013 June 2,2018 N/A
Load Line Certificate (Coastwise) May 30,2008 May 30,2013 ABS
NLS Certificate November 15,2013 June 2,2018 N/A
Tonnage Certificate, International May 27,2003 N/A