IMO/VIN
Callsign
Flag
Service
Year
1139764
WDM9210
UNITED STATES
Tank Barge
2003
Activity#
Port
Date
Activity - Description
Deficiencies
7457925
STATEN ISLAND, New York
May 24, 22
Vessel Inspection - Administrative Action
7438699
STATEN ISLAND, New York
Apr 28, 22
Vessel Inspection - Approved Inspection
7128472
STATEN ISLAND, New York
Jan 22, 21
Vessel Inspection - Agency Action Complete
1
0
System Subsystem Cause 01 - Certificates & Documentation 011 - Ships Certificates Invalid
Description Due Date Resolved Certificates of Inspection will be issued for a period of 5 years; COI deactivated on 21JAN21 due to missed periodic inspection.
Complete COI Inspection prior to conducting cargo operations. May 18, 23 Yes
Resolved Date Resolution Mar 24, 22 Conducted inspection for certification.
6813713
STATEN ISLAND, New York
Sep 17, 19
Vessel Inspection - Approved Inspection
4
0
System Subsystem Cause 09 - Working and Living Conditions 092 - Working Conditions Damaged By Earlier Event
Description Due Date Resolved Generator room has 110v f/o alarm panel that has the visual indicator lighting that was punched out and could allow a person access to the wiring within.
46 CFR 111.01(a)(2) Oct 01, 19 Yes
Resolved Date Resolution Oct 29, 19 Lights were re-installed and covered. All Sat
System Subsystem Cause 09 - Working and Living Conditions 092 - Working Conditions Damaged By Earlier Event
Description Due Date Resolved Generator room has the hydraulic 440V pnl with a door that does not close.
46 CFR 111.01(a)(2) Oct 01, 19 Yes
Resolved Date Resolution Oct 29, 19 New latch mech was installed and verified.
System Subsystem Cause 06 - Cargo Operations Including Equipment N/A - No Subsystem
Description Due Date Resolved Vapor trunks from the cargo pump to the pump room had holes and were missing the band clamps making them not vapor tight.
46 CFR 111.105-31(k)(1) Oct 01, 19 Yes
Resolved Date Resolution Oct 29, 19 Vapor trunks were replaced with new along with clamps
System Subsystem Cause 06 - Cargo Operations Including Equipment N/A - No Subsystem
Description Due Date Resolved Vessel has leaking closed gauging windows on tanks 1-7P and 2,3,4,5,7 stbd. Closed gauging was rtv'd shut.
46 CFR 151.15-10(c) Oct 01, 19 Yes
Resolved Date Resolution Oct 29, 19 Replaced all gaskets on the closed gauging system. Conducted a pressure test @1.5 psi. Verified no pressure drop and that sightglass did not bubble when soapy solution was applied.
6436545
STATEN ISLAND, New York
Jun 07, 18
Vessel Inspection - Agency Action Complete
1
0
System Subsystem Cause 09 - Working and Living Conditions 092 - Working Conditions Improper/Lack of Maintenance
Description Due Date Resolved There must be ground detection for each: (b) Ship's power service system. Faulty ground detection noted on the 120V system. O/O to mitigate deficiency accordingly. Aug 03, 18 Yes
Resolved Date Resolution Nov 20, 18 Follow up conducted w/Owner-Operator and system is functioning to the satisfaction of the Marine Inspector.
6405763
STATEN ISLAND, New York
Jan 10, 18
Vessel Inspection - Approved Inspection
8
0
System Subsystem Cause Deck/Cargo Holds/Tanks
Description Due Date Resolved #3S cargo tank P/V valve had plug in the place of drain. Yes
Resolved Date Resolution Jan 11, 18 Replaced plug with drain fitting with new flame screen.
System Subsystem Cause Electrical Electrical Distribution System (service)
Description Due Date Resolved 120V and 240V panels in generator room are missing breaker covers. Jan 17, 18 Yes
Resolved Date Resolution Jan 11, 18 Covers were installed.
System Subsystem Cause Documentation Logs/Records
Description Due Date Resolved Abandon ship drills and fire fighting drills were not properly logged. Barge Captain was using company drill schedule and record sheets, however these drills were being documented and incorporated into other drill-types, and not as separate drills and individual items on the log. Jan 10, 18 Yes
Resolved Date Resolution Jan 10, 18 Onboard training was conducted.
System Subsystem Cause Deck/Cargo Holds/Tanks
Description Due Date Resolved Fwd rake entrance is within haz zone. Entrance has open wire runs that impede vapor tightness. Yes
Resolved Date Resolution Jan 11, 18 Wire runs were sealed.
System Subsystem Cause Electrical Electrical Distribution System (service)
Description Due Date Resolved Ground detection for 120V system in not functioning. Jan 17, 18 Yes
Resolved Date Resolution Jan 11, 18 Indicated ground was eliminated.
System Subsystem Cause Lifesaving Lifebuoys
Description Due Date Resolved Life rings not properly marked with name of vessel and hailing port. Feb 10, 18 Yes
Resolved Date Resolution Jan 11, 18 Markings were stenciled on.
System Subsystem Cause Deck/Cargo Cargo Transfer/Lightering (liquid)
Description Due Date Resolved Spare hoses at manifold need blank flanges and to be tested prior to use. Jan 11, 18 Yes
Resolved Date Resolution Jan 11, 18 Hoses were removed from the barge.
System Subsystem Cause Construction/Loadline Penetrations
Description Due Date Resolved The gaskets on port and starboard aft rake hatches are not continuous. Jan 17, 18 Yes
Resolved Date Resolution Jan 11, 18 Gaskets were replaced.
6150375
STATEN ISLAND, New York
May 13, 17
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Construction/Loadline Structures Damaged By Earlier Event
Description Due Date Resolved C/R sideshell plating IWO canted frame C to anchor slide PS forepeak; approx. 8-10 ft. by 12-15 ft. section to the satisfaction of the attending CG marine inspector. Vessel is allowed to discharge all cargo, then proceed to do repair to the satisfaction of the attending CG marine inspector. Prior to each movement contact the CG Sector NY Command Center at (718) 354-4353. Yes
Resolved Date Resolution May 23, 17 Inspected final repair, found satisfactory.
6048560
BOSTON, Massachusetts
Nov 28, 16
Vessel Transfer Monitor - Approved Inspection
5914007
STATEN ISLAND, New York
Jun 23, 16
Vessel Inspection - Approved Inspection
5794891
BOSTON, Massachusetts
Jan 11, 16
Vessel Transfer Monitor - Approved Inspection
5099576
ST PETERSBURG, Florida
Apr 10, 15
Vessel Inspection - Agency Action Complete
5099576
Tampa, Florida
Apr 10, 15
Vessel Inspection - Agency Action Complete
4984056
STATEN ISLAND, New York
Sep 15, 14
Vessel Inspection - Agency Action Complete
4951429
Miami Beach, Florida
Aug 12, 14
Vessel Inspection - Approved Inspection
5
0
System Subsystem Cause Fire Fighting Miscellaneous Items
Description Due Date Resolved Properly stow all flam liquids, paint, and used batteries from the machinery spaces and decks. Aug 13, 14 Yes
Resolved Date Resolution Aug 13, 14
System Subsystem Cause Electrical Electrical Distribution System (service)
Description Due Date Resolved Remove extension cord providing power to chest freezers in the stbd pump room. Aug 13, 14 Yes
Resolved Date Resolution Aug 13, 14
System Subsystem Cause Deck/Cargo Cargo Transfer/Lightering (liquid)
Description Due Date Resolved Repair fuel leak on #2 cargo pump prime mover IWO fuel filter. Aug 13, 14 Yes
Resolved Date Resolution Aug 13, 14
System Subsystem Cause Deck/Cargo Cargo Transfer/Lightering (liquid)
Description Due Date Resolved Repair oil leak on #2 cargo pump prime mover oil cooler IWO after cooler. Aug 19, 14 Yes
Resolved Date Resolution Aug 19, 14
System Subsystem Cause Documentation Certificates/Documents
Description Due Date Resolved Vessel is not to carry more than 2 persons as permitted on the COI. Contact CG Sector St Pete to de-conflict the COI manning with actual operations. Aug 13, 14 Yes
Resolved Date Resolution Sep 15, 14 Sector new York amending COI to reflect change in manning.
4617370
STATEN ISLAND, New York
Jun 10, 13
Vessel Inspection - Agency Action Complete
3
0
System Subsystem Cause Deck/Cargo Vapor Control Systems
Description Due Date Resolved All four Vapor Control connection piping was not properly painted/color coated.
46 CFR 39.20-1 Jul 05, 13 Yes
Resolved Date Resolution Jun 24, 13 Crewmembers onboard the vessel painted all four vapor control lines.
System Subsystem Cause Electrical Electric Generation Source (service)
Description Due Date Resolved House genereator was inoperable and not ready for inspection.
46. CFR 111.12 Jul 31, 13 Yes
Resolved Date Resolution Jul 16, 13 Operated the vessel''s house generator and tested the over speed and lube oil pressure safety trips. test was all satisfactory.
System Subsystem Cause Lifesaving Line-Throwing Appliances
Description Due Date Resolved Line throwing gun not onboard the during the COI examing.
46 CFR 199.170 Jul 05, 13 Yes
Resolved Date Resolution Jun 21, 13 Vessel brought on a valid Line Throwing gun prior to coast guard inspectors departing the vessel.
4388963
STATEN ISLAND, New York
Jul 24, 12
Vessel Inspection - Agency Action Complete
4375446
STATEN ISLAND, New York
Jul 11, 12
Vessel Inspection - Agency Action Complete
1
0
System Subsystem Cause Deck/Cargo Cargo Transfer/Lightering (liquid)
Description Due Date Resolved Replace seals in between pump house and cargo (hazardous) area to maintain Class I, Div I divisions. (Prior to carriage of cargo w/ flash point 140F ir below) Aug 11, 12 Yes
Resolved Date Resolution Jul 24, 12 Rcvd proof of replacement
4260321
WASHINGTON, District of Columbia
Mar 09, 12
Incident Investigation - Agency Action Complete
4035899
STATEN ISLAND, New York
Jun 01, 11
Vessel Inspection - Agency Action Complete
3938278
STATEN ISLAND, New York
Feb 03, 11
Vessel Transfer Monitor - Approved Inspection
3917313
WASHINGTON, District of Columbia
Dec 27, 10
Incident Investigation - Agency Action Complete
3864661
NEW HAVEN, Connecticut
Oct 06, 10
Vessel Transfer Monitor - Agency Action Complete
3767858
STATEN ISLAND, New York
Jun 16, 10
Vessel Inspection - Agency Action Complete
3720453
NEW HAVEN, Connecticut
Apr 20, 10
Vessel Inspection - Approved Inspection
3719899
NEW HAVEN, Connecticut
Apr 19, 10
Vessel Transfer Monitor - Agency Action Complete
3658856
NEW HAVEN, Connecticut
Jan 05, 10
Vessel Inspection - Agency Action Complete
3654071
STATEN ISLAND, New York
Dec 22, 09
Vessel Inspection - Agency Action Complete
3652517
NEW HAVEN, Connecticut
Dec 18, 09
Vessel Transfer Monitor - Agency Action Complete
3627628
WASHINGTON, District of Columbia
Oct 14, 09
Incident Investigation - Agency Action Complete
3527574
WASHINGTON, District of Columbia
Jul 07, 09
Incident Investigation - Agency Action Complete
3514424
STATEN ISLAND, New York
Jun 26, 09
Vessel Inspection - Agency Action Complete
3453870
WASHINGTON, District of Columbia
Apr 08, 09
Incident Investigation - Agency Action Complete
3447809
STATEN ISLAND, New York
Apr 07, 09
Vessel Inspection - Agency Action Complete
3295961
NEW HAVEN, Connecticut
Aug 11, 08
Vessel Transfer Monitor - Agency Action Complete
3221661
STATEN ISLAND, New York
May 29, 08
Vessel Inspection - Agency Action Complete
3207160
NEW HAVEN, Connecticut
May 15, 08
Vessel Transfer Monitor - Agency Action Complete
3147076
WASHINGTON, District of Columbia
Feb 13, 08
Incident Investigation - Agency Action Complete
3021782
STATEN ISLAND, New York
Aug 09, 07
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Pollution Prevention/Response Prevention Equipment
Description Due Date Resolved Prove operation of visual alarm for overfill protection system Sep 09, 07 Yes
Resolved Date Resolution Aug 10, 07 Recieved tech report stating that overfill alarm is in proper working order.
2888473
STATEN ISLAND, New York
Mar 15, 07
Facility Transfer Monitor - Approved Inspection
2743862
Washington, District of Columbia
Aug 11, 06
Vessel Inspection - Security Plan Approved by MSC
2656450
STATEN ISLAND, New York
May 23, 06
Vessel Inspection - Approved Inspection
2634954
STATEN ISLAND, New York
Apr 27, 06
Vessel Transfer Monitor - Approved Inspection
2603050
Washington, District of Columbia
Mar 15, 06
Vessel Inspection - Security Plan Approved by MSC
2578883
Washington, District of Columbia
Feb 03, 06
Vessel Inspection - Administrative Action
2384524
STATEN ISLAND, New York
Jun 09, 05
Vessel Inspection - Agency Action Complete
2309849
Washington, District of Columbia
Mar 14, 05
Vessel Inspection - Security Plan Approved by MSC
2274042
Woods Hole, Massachusetts
Jan 12, 05
Vessel Transfer Monitor - Approved Inspection
2241230
GRETNA, Louisiana
Nov 15, 04
Vessel Inspection - Approved Inspection
2140226
STATEN ISLAND, New York
Jul 21, 04
Vessel Inspection - Approved Inspection
2147892
Woods Hole, Massachusetts
Jul 19, 04
Vessel Transfer Monitor - Approved Inspection
2080664
Washington, District of Columbia
May 28, 04
Vessel Inspection - Security Plan Approved by MSC
1962413
Washington, District of Columbia
Dec 09, 03
Vessel Inspection - ASP Criteria Met
1925402
NEW HAVEN, Connecticut
Oct 10, 03
Vessel Transfer Monitor - Agency Action Complete
1797328
New Orleans, Louisiana
May 20, 03
Vessel Inspection - Approved Inspection
3
0
System Subsystem Cause Pollution Prevention/Response
Description Due Date Resolved Porvide SOPEP Jun 30, 03 Yes
Resolved Date Resolution Jun 10, 03
System Subsystem Cause Deck/Cargo
Description Due Date Resolved Provide Cargo Authority Authorization. Jun 30, 03 Yes
Resolved Date Resolution Jun 05, 03
System Subsystem Cause Pollution Prevention/Response
Description Due Date Resolved Provide Certificate of Financial Responsibility Yes
Resolved Date Resolution Jun 10, 03
Documents
Issued
Expires
Agency
Cargo Authority Attachment
January 9,2009
N/A
CERTIFICATE OF DOCUMENTATION
August 23,2021
August 31,2022
USCG
Certificate of Inspection
May 30,2003
May 30,2008
N/A
Certificate of Inspection - Amended
May 30,2003
May 30,2008
N/A
Classification Document
May 30,2008
May 30,2013
N/A
International Load Line Certificate
May 30,2008
May 30,2013
N/A
International Oil Pollution Prevention Certificate
November 15,2013
June 2,2018
N/A
Load Line Certificate (Coastwise)
May 30,2008
May 30,2013
ABS
NLS Certificate
November 15,2013
June 2,2018
N/A
Tonnage Certificate, International
May 27,2003
N/A