Riverside
Print Q88   
IMO/VIN Callsign Flag Service Year
9412464 9HA5289 MALTA Tank Ship 2009
Activity# Port Date Activity - Description Deficiencies
7412799 New Orleans, Louisiana Mar 29, 22 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
14 - Pollution Prevention148 - Ballast WaterDamaged By Earlier Event
DescriptionDue DateResolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO attended vessel after recieveing report of hydraulic fluid leak into #6 Ballast tank. Vessel personnel determined that #5 port or #6 port tank valves are the cause of the hydraulic fluid leaking into the #6 ballast tank. Request repair plan for the correction of hydraulic leak and cleaning of any contaminated tanks and components. Vessel is not authorized to discharge any contaminated or untreated ballast at any time. 74SOLAS(20) I-11.aYes
Resolved DateResolution
Apr 12, 22PSC NOLA received a class report from ABS satisfying the requirement.
7298675 Houston, Texas Aug 28, 21 Vessel Inspection - Approved Inspection
7279041 New Orleans, Louisiana Aug 11, 21 Vessel Inspection - Approved Inspection
7281561 New Orleans, Louisiana Aug 09, 21 Vessel Inspection - Administrative Action
7221630 WASHINGTON, District of Columbia Jun 10, 21 Vessel Inspection - Approved Inspection
7156677 CORPUS CHRISTI, Texas Mar 15, 21 Vessel Inspection - Agency Action Complete
  6
SystemSubsystemCause
02 - Structural ConditionsN/A - No Subsystem
DescriptionDue DateResolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. Electrical junction boxes for General Service/Fire and Fire/Bilge pumps were found to be hanging loosely and without proper support. 74 SOLAS (04 Cons.) Ch. II-1/Reg. 45.1.3Yes
Resolved DateResolution
Mar 27, 21DNV Class report outlining rectification of the electrical junction boxes for the General Service/Fire and Fire/Bilge pumps received. Crew completed secure mounting of electrical junction boxes.
SystemSubsystemCause
02 - Structural ConditionsN/A - No Subsystem
DescriptionDue DateResolved
Cables and wiring shall be installed and supported in such a manner as to avoid chafing or other damage. Cabling for General Service/Fire and Fire/Bilge pumps were found to be exposed and improperly fastened to cable glands. 74 SOLAS (04 Cons.) Ch. II-1/Reg. 45.5.5Yes
Resolved DateResolution
Mar 27, 21DNV Class report outlining rectification of cabling for General Service/Fire and Fire/Bilge pumps received. Crew conducted repairs; reconnected and tightened cable glands/secured loose cables.
SystemSubsystemCause
13 - Propulsion and Auxiliary MachineryN/A - No Subsystem
DescriptionDue DateResolved
Main and auxiliary machinery essential for the propulsion and safety of the ship shall be provided with effective means for its operation and control. Vessel reported a loss of propulsion during outbound transit on 03/15/2021 resulting in the allision of the vessel with the MODA pier located in Ingleside, TX. Vessel's main engine shut down and crew was unable to regain propulsion and maneuverability. 74 SOLAS (04) II-1/31.1Yes
Resolved DateResolution
Mar 27, 21DNV Class report outlining main engine failure due to stuck #6 actuator in the start air distributor received. MAN service engineer completed repairs. Main engine operational test and propulsion sea trials completed.
SystemSubsystemCause
15 - Safety Management Systems (ISM)N/A - No Subsystem
DescriptionDue DateResolved
Objective evidence discovered in an expanded ISM exam revealed the following non-conformities; the vessel failed to fully implement the requirements of the SMS as evident by deficiency #01 and #02. An external audit is required. 74 SOLAS (20 Cons.) Ch. IX 3 & 5/ISM Code 9Yes
Resolved DateResolution
Mar 27, 21DNV external audit completed. Shipboard ISM audit report listing Non-conformity and Observations, Class report, and Corrective Action Plan received.
SystemSubsystemCause
13 - Propulsion and Auxiliary MachineryN/A - No Subsystem
DescriptionDue DateResolved
Precautions shall be taken to prevent any oil that may escape under pressure from any pump, filter or heater coming into contact with heated surfaces. Main diesel engine was found to have fuel leaking from #1 and #5 fuel oil pumps. PSCO observed excess amount of fuel oil collecting on top of the main diesel engine, leaking over the #1 and #5 fuel oil pumps, and expending onto the main engine A-Frame. 74 SOLAS (04 Cons.) Ch.II-2/Reg.4.2.2.6.2Yes
Resolved DateResolution
Mar 27, 21DNV Class report outlining rectification of fuel oil pump leaks received. Crew overhauled and replaced damaged seals. Areas where collection of fuel oil have been rectified.
SystemSubsystemCause
02 - Structural ConditionsN/A - No Subsystem
DescriptionDue DateResolved
Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault in such areas, special precautions against such risks shall be taken to the satisfaction of the Administration. Cabling from the fuel circulation pumps in the fuel oil purifier room was found to be exposed and not properly secured. 74 SOLAS (04 Cons.) Ch. II-1/Reg. 45.5.4Yes
Resolved DateResolution
Mar 27, 21DNV Class report outlining rectification of exposed and unsupported cables on the fuel oil circulating pumps in the fuel oil purifier room received. Crew conducted repairs; reconnected and tightened cable glands/secured loose cables.
7156808 WASHINGTON, District of Columbia Mar 15, 21 Incident Investigation - Agency Action Complete
7127482 CORPUS CHRISTI, Texas Jan 20, 21 Vessel Inspection - Agency Action Complete
7054273 BATON ROUGE, Louisiana Sep 09, 20 Vessel Inspection - Approved Inspection
6642662 Honolulu, Hawaii Mar 21, 19 Vessel Inspection - Approved Inspection
6189712 CORPUS CHRISTI, Texas Jul 03, 17 Vessel Inspection - Approved Inspection
6090635 TEXAS CITY, Texas Feb 17, 17 Boarding - Agency Action Complete
5939399 New Orleans, Louisiana Jul 20, 16 Vessel Inspection - Approved Inspection
5941311 New Orleans, Louisiana Jul 15, 16 Vessel Operational Control - Agency Action Complete
5926126 Christiansted, Virgin Islands Jul 02, 16 Vessel Inspection - Approved Inspection
4623781 CORPUS CHRISTI, Texas Jun 25, 13 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations. The incinerator was inoperable.Jul 09, 13Yes
Resolved DateResolution
Jul 01, 16Cleared during exam.
SystemSubsystemCause
EngineeringFreshwater System (jacketwater cooling)
DescriptionDue DateResolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations. There was excessive leakage on the jacket water line.Jul 09, 13Yes
Resolved DateResolution
Jul 01, 16Cleared during exam.
4543258 New Orleans, Louisiana Mar 10, 13 Vessel Inspection - Approved Inspection
4544563 New Orleans, Louisiana Mar 06, 13 Vessel Inspection - Agency Action Complete
4530749 New Orleans, Louisiana Feb 09, 13 Vessel Operational Control - Administrative Action
4376682 STATEN ISLAND, New York Jul 13, 12 Vessel Inspection - Approved Inspection
4265997 Lake Charles, Louisiana Mar 24, 12 Vessel Inspection - Approved Inspection
4109866 PHILADELPHIA, Pennsylvania Aug 08, 11 Vessel Inspection - Approved Inspection
4089777 CORPUS CHRISTI, Texas Jul 21, 11 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
NavigationCollision/Grounding AvoidanceImproper/Lack of Maintenance
DescriptionDue DateResolved
MASTER REPORTED THAT THE VESSELS ECHO DEPT SOUNDER LOST FUNCTIONALITY, LOD OUTBOUND REQUEST GRANTED BY COTP UNDER THE CONDITION THAT VESSEL IS TUG ASSISTED, AND DAYLIGHT RESTRICTED AS WELL.Jul 22, 11Yes
Resolved DateResolution
Aug 09, 11Vessel submitted a tech report for the Echo Depth Sounder. Echo Depth Sounder has been repaired and tested operational.
4089654 CORPUS CHRISTI, Texas Jul 20, 11 Vessel Inspection - Approved Inspection
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel September 9,2020 September 9,2022 BATU
Classification Document July 26,2018 June 3,2019 DNV GL
COC-TVE Annual September 9,2020 September 9,2021 N/A
COC-TVE Renewal March 21,2019 March 21,2021 N/A
International Load Line Certificate May 22,2021 June 3,2024 DNV
International Oil Pollution Prevention Certificate March 27,2022 May 26,2022 DNV
ISM - Document Of Compliance October 13,2008 October 13,2013 DNV
ISM - Safety Management Certificate May 22,2021 September 11,2025 DNV
Minimum Safe Manning Document May 4,2017 MH
SOLAS Cargo Ship Safety Certificate June 3,2009 June 3,2014 DNV
SOLAS Cargo Ship Safety Construction Certificate May 22,2021 June 3,2024 DNV
SOLAS Cargo Ship Safety Equipment Certificate May 22,2021 June 3,2024 DNV
SOLAS Cargo Ship Safety Radio Certificate July 24,2018 June 3,2019 DNV GL
Tonnage Certificate, International January 17,2011 DNV