Torm Amalie
Print Q88   
IMO/VIN Callsign Flag Service Year
9466025 9V8552 SINGAPORE Tank Ship 2011
Activity# Port Date Activity - Description Deficiencies
7372628 San Pedro, California Dec 27, 21 Boarding - Agency Action Complete
7274891 STATEN ISLAND, New York Aug 02, 21 Vessel Inspection - Approved Inspection
6924852 San Pedro, California Mar 21, 20 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
07 - Fire SafetyN/A - No Subsystem
DescriptionDue DateResolved
The system shall be capable of discharging through fixed discharge outlets, in no more than 5 min, a quantity of foam sufficient to produce an effective foam blanket over the largest single area over which oil fuel is liable to spread. PSC Examiners were unable to determine if the vessel had sufficient foam concentrate onboard.Mar 21, 20Yes
Resolved DateResolution
Mar 23, 20Received class report from DNV-GL attesting to the proper amount of foam concentrate on board.
6452184 New Orleans, Louisiana Jun 22, 18 Vessel Inspection - Approved Inspection
6161259 Port Arthur, Texas Jun 01, 17 Vessel Inspection - Approved Inspection
6141152 Miami Beach, Florida May 13, 17 Vessel Inspection - Approved Inspection
6083293 New Orleans, Louisiana Feb 06, 17 Vessel Inspection - Administrative Action
6082090 New Orleans, Louisiana Feb 03, 17 Vessel Operational Control - Agency Action Complete
5948317 Brownsville, Texas Jul 25, 16 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
CommunicationsLong Range Identification and Tracking (LRIT)Improper/Lack of Maintenance
DescriptionDue DateResolved
Ships shall be fitted with a system to automatically transmit the vessels identity and position information. The vessel's long-range identification and tracking (LRIT) is inoperable. SOLAS 74(2009 cons.) Ch.V/19-1.4.1Yes
Resolved DateResolution
Jul 27, 16Prior to next port, to the satisfaction of RO/RSO and Coast Guard
5734035 New Orleans, Louisiana Oct 02, 15 Vessel Operational Control - Agency Action Complete
5738475 WASHINGTON, District of Columbia Oct 01, 15 Incident Investigation - Agency Action Complete
5733848 New Orleans, Louisiana Oct 01, 15 Vessel Operational Control - Agency Action Complete
5131546 CORPUS CHRISTI, Texas May 28, 15 Vessel Inspection - Approved Inspection
  9
SystemSubsystemCause
Fire FightingCombustible MaterialsImproper/Lack of Maintenance
DescriptionDue DateResolved
0710- Fire Prevention- The purpose is to prevent the ignition of combustible materials. PSCOs observed excess lube oil pooled on main diesel engine by number five and number six cylinders. 74 SOLAS 04 CONS II-2/4.3Yes
Resolved DateResolution
May 29, 15A class survey report and photos were provided to the USCG showing the lube oil had been cleaned from the main diesel engine.
SystemSubsystemCause
Fire FightingCombustible MaterialsImproper/Lack of Maintenance
DescriptionDue DateResolved
0710- Fire Prevention- The purpose is to prevent the ignition of combustible materials. PSCOs observed excess oil underneath generator number one in buckets, on deck and in containment. 74 SOLAS 04 CONS II-2/4.3Yes
Resolved DateResolution
May 29, 15A class survey report and photos were provided showing the excess oil was satisfactorily cleaned.
SystemSubsystemCause
Fire FightingCombustible MaterialsImproper/Lack of Maintenance
DescriptionDue DateResolved
0710- Fire Prevention- The purpose is to prevent the ignition of combustible materials. PSCOs observed oil soaked lagging throughout engine room. 74 SOLAS 04 CONS II-2/ 4.3Yes
Resolved DateResolution
May 29, 15A class survey report and photos were provided to the USCG attesting to the proper repair of the oil soaked lagging.
SystemSubsystemCause
Fire FightingCombustible MaterialsImproper/Lack of Maintenance
DescriptionDue DateResolved
0710- Fire Prevention- The purpose is to prevent the ignition of combustible materials. PSCOs observed oil soaked lagging throughout the generator space. 74 SOLAS 04 CONS II-2/4.3Yes
Resolved DateResolution
May 29, 15A class survey report and pictures were provided to the USCG, confirming new lagging had been placed in required areas.
SystemSubsystemCause
Fire FightingCombustible MaterialsDamaged By Earlier Event
DescriptionDue DateResolved
0710- Fire Prevention- The purpose is to prevent the ignition of combustible materials. PSCOs observed the exhaust lagging on ship service generator number 2 in wasted condition. 74 SOLAS 04 CONS II-2/4.3Yes
Resolved DateResolution
May 29, 15A Class survey report and photos were provided to the USCG and new lagging was placed on ship service generator number 2.
SystemSubsystemCause
Fire FightingRemote Fuel ShutoffImproper/Lack of Maintenance
DescriptionDue DateResolved
0899- Accident Prevention- After survey of the ship has been completed, no change shall be made in the structural arrangement, equipment, fittings, or machinery and other items covered by the survey without sanction. PSCOs discovered a nonrated soft plastic hose piped from the HFO holding tank in the Purifier room to the LSFO drain going to the sludge tank. 74 SOLAS 09 CONS I/II.Yes
Resolved DateResolution
May 29, 15A Class survey report was provided to the USCG and the unapproved softpipe was removed and clogged HFO and LSFO drain was restored to oeprational use.
SystemSubsystemCause
Construction/LoadlineMarkingsImproper/Lack of Maintenance
DescriptionDue DateResolved
1220- Freeboard Marks- The ring, lines, and letters shall be painted in white or yellow on dark ground. PSCOs observed the deck reference line not painted. ICLL 1-9Yes
Resolved DateResolution
May 28, 15A class survey report was provided to the USCG.
SystemSubsystemCause
Construction/LoadlineStructures
DescriptionDue DateResolved
2199- Other, Operational Def- The condition of the ship shall be maintained to conform with the provisions of the present regulations. PSCOs observed excess marine growth on the waterline and hull of the ship. International Convention on the Control of Harmful Anti-Fouling Systems on Ships. (74 SOLAS 09 CONS I/II)Yes
Resolved DateResolution
Jul 25, 16PSCO witness satifactory correction to deficiency issued.
SystemSubsystemCause
Operations/ManagementVessel Safety Management
DescriptionDue DateResolved
2560- Company Verification and Review- The Company should carry out internal safety audits on board and to verify compliance with the safety management system. PSCO's recommend ISM audit. 74 SOLAS 09 CONS IX/3 and ISM Code 12Yes
Resolved DateResolution
May 29, 15A Class survey report was provided to the USCG, outlining the findings of an vessel ISM audit, with no major or minor Non-conformities.
5031571 PORT ARANSAS, Texas Nov 30, 14 Boarding - Agency Action Complete
5029631 CORPUS CHRISTI, Texas Nov 25, 14 Vessel Operational Control - Agency Action Complete
4951470 Port Arthur, Texas Aug 14, 14 Vessel Inspection - Approved Inspection
4765745 San Francisco, California Dec 08, 13 Vessel Inspection - Approved Inspection
4597982 Port Arthur, Texas May 24, 13 Vessel Inspection - Approved Inspection
4047510 Portsmouth, Virginia Jun 17, 11 Vessel Inspection - Approved Inspection
Documents Issued Expires Agency
Certificate of Fitness - Chemical Carrier February 24,2020 February 28,2021 Class
Classification Document August 21,2013 February 29,2016 DNV
International Certificate of Fitness - Chemical March 21,2014 February 29,2016 ABS
International Load Line Certificate April 19,2011 February 29,2016 DNV
International Oil Pollution Prevention Certificate February 24,2020 July 12,2022 DNV
ISM - Document Of Compliance April 20,2018 May 1,2023 LR
ISM - Safety Management Certificate March 2,2011 September 1,2011 BV
Minimum Safe Manning Document March 2,2016 February 28,2021 SG
SOLAS Cargo Ship Safety Construction Certificate March 24,2014 February 29,2016 ABS
SOLAS Cargo Ship Safety Equipment Certificate March 24,2014 February 29,2016 ABS
SOLAS Cargo Ship Safety Radio Certificate April 19,2011 February 29,2016 DNV
Tonnage Certificate, International November 10,2010 DNV