Tavrichesky Bridge
Print Q88   
IMO/VIN Callsign Flag Service Year
9292060 A8IZ6 LIBERIA Tank Ship 2006
Activity# Port Date Activity - Description Deficiencies
7200834 PHILADELPHIA, Pennsylvania May 19, 21 Vessel Inspection - Approved Inspection
7168725 NEW HAVEN, Connecticut Apr 05, 21 Vessel Inspection - Agency Action Complete
6953802 CORPUS CHRISTI, Texas May 20, 20 Vessel Inspection - Approved Inspection
6683007 Houston, Texas May 19, 19 Vessel Inspection - Approved Inspection
6412144 New Orleans, Louisiana May 14, 18 Vessel Inspection - Approved Inspection
  4
SystemSubsystemCause
Fire FightingRemote Fuel Shutoff
DescriptionDue DateResolved
0750- Fire Prevention - PSCO observed the air reservoir for the engine room quick closing fuel shutoff valves was empty and the gauge at zero due to leaking air line. A requirement was issued to provide a class report attesting normal operation prior to movement. -74 SOLAS (2009 cons) II-2/4.2.2.3.4 -60aMay 14, 18Yes
Resolved DateResolution
May 16, 18Received, reviewed and accepted calls report from LR stating the deficiency was rectified. activation valve was replaced and air receiver was able to hold pressure.
SystemSubsystemCause
Fire FightingRemote Fuel Shutoff
DescriptionDue DateResolved
0750- Fire prevention - PSCO observed the quick closing fuel shutoff valve on the No. 1 HFO Service Tank was nonoperational after testing. A requirement was issued to provide a class report attesting to the proper operation of the valve prior to movement. -74 SOLAS (2009 cons) II-2/4.2.2.3.4 -60aMay 14, 18Yes
Resolved DateResolution
May 16, 18Received, reviewed and accepted calls report from LR stating the deficiency was rectified. All vavles were tested with satisfactor results
SystemSubsystemCause
Operations/ManagementBallast Water Managment
DescriptionDue DateResolved
9900- Other(not clearly hazardous)- The Master, Owner, Operator, Agent, or person in charge of a vessel equipped with ballast tanks that operate in the waters of the United States must employ one of the ballast water management methods listed in 33 CFR 151.2025. Vessel is outfitted with an approved alternative management system (AMS) described in 33 CFR 151.2025(a) (3), but failed to use the AMS while conducting a ballast water operations in the Mississippi River in April of 2018 .- 33CFR151.2025(a) CMay 14, 18Yes
Resolved DateResolution
May 18, 18Received, reviewed and accepted corrective action plan from company and amended company wide ballast procedures
SystemSubsystemCause
Operations/ManagementBallast Water Managment
DescriptionDue DateResolved
9900- Other(not clearly hazardous)- The Master, Owner, Operator, Agent, or person in charge of a vessel equipped with ballast tanks that operate in the waters of the United States must employ one of the ballast water management methods listed in 33 CFR 151.2025. Vessel is outfitted with an approved alternative management system (AMS) described in 33 CFR 151.2025(a) (3), but failed to use the AMS while conducting a ballast water operations in the Mississippi River. Vessel is prohibited from discharging untreated ballast water until one of the management requirements in 33 CFR 151.2025 is met.- 33CFR151.2025(a) CMay 14, 18Yes
Resolved DateResolution
May 18, 18Vessel conducted ballast water exchange outside 12 NM and has treated BW onboard the vessel.
6374441 BOSTON, Massachusetts Mar 18, 18 Vessel Inspection - Approved Inspection
6124325 STATEN ISLAND, New York Apr 14, 17 Vessel Inspection - Approved Inspection
6024719 CORPUS CHRISTI, Texas Oct 20, 16 Vessel Inspection - Agency Action Complete
5797136 ST PETERSBURG, Florida Jan 14, 16 Boarding - Agency Action Complete
5797136 Tampa, Florida Jan 14, 16 Boarding - Agency Action Complete
5795528 ST PETERSBURG, Florida Jan 12, 16 Vessel Operational Control - Agency Action Complete
5795528 Tampa, Florida Jan 12, 16 Vessel Operational Control - Agency Action Complete
5782899 San Juan, Puerto Rico Dec 20, 15 Vessel Inspection - Approved Inspection
5157736 STATEN ISLAND, New York Jun 19, 15 Vessel Operational Control - Failure to Show
5114115 Miami Beach, Florida Apr 30, 15 Vessel Inspection - Approved Inspection
5023133 Mobile, Alabama Nov 13, 14 Vessel Operational Control - Approved Inspection
5019194 STATEN ISLAND, New York Nov 07, 14 Vessel Inspection - Approved Inspection
4966115 Lake Charles, Louisiana Aug 29, 14 Vessel Inspection - Approved Inspection
4874487 Miami Beach, Florida May 30, 14 Vessel Inspection - Approved Inspection
4742553 BOSTON, Massachusetts Nov 04, 13 Vessel Inspection - Approved Inspection
4575028 Ponce, Puerto Rico Apr 23, 13 Vessel Inspection - Approved Inspection
4547614 CORPUS CHRISTI, Texas Mar 09, 13 Vessel Operational Control - Approved Inspection
4545823 Port Arthur, Texas Mar 06, 13 Vessel Operational Control - Agency Action Complete
  1
SystemSubsystemCause
NavigationCollision/Grounding Avoidance
DescriptionDue DateResolved
Vessels secondary radar screen is inoperable. Vessel was issued a outbound LOD and will have repairs made no later than 07Apr2013. See attached dispensation from Flag Administration.Apr 07, 13Yes
Resolved DateResolution
Apr 02, 13Received tech report confiming repair of vessels secondary radar.
4398030 San Juan, Puerto Rico Aug 01, 12 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
LifesavingLifeboatImproper/Lack of Maintenance
DescriptionDue DateResolved
0610- Before the ship leaves port and at all times during the voyage, all lifesaving equip. shall be in working order. Lifeboat battery was replaced and not charged. Must charge and prove proper operation of lifeboat.-SOLAS Ch3 Reg 20.2-17CAug 05, 12Yes
Resolved DateResolution
Aug 06, 12VSL received new batteries for the lifeboat and was able to prove proper operation.
3719500 STATEN ISLAND, New York Apr 19, 10 Vessel Inspection - Approved Inspection
3687984 STATEN ISLAND, New York Mar 01, 10 Vessel Inspection - Agency Action Complete
3668040 STATEN ISLAND, New York Jan 22, 10 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
EngineeringDiesel Engine (propulsion-direct drive)
DescriptionDue DateResolved
PSCO witnessed the broken cam chain on the main engine. Vessel shall make repairs to the satisfaction of class. Solas Reg 26 CH II-1. 17(a)Feb 23, 10Yes
Resolved DateResolution
Feb 22, 10After receiving faxed confirmation (class report from LR #MMI 000084) that defs issued on 22JAN10 by USCG Sector NY (activity# 3668040) was corrected, cleared the same. No deficiencies remain. LTJG Walsh
3666555 STATEN ISLAND, New York Jan 20, 10 Vessel Operational Control - Agency Action Complete
3666203 WASHINGTON, District of Columbia Jan 19, 10 Incident Investigation - Agency Action Complete
3428711 STATEN ISLAND, New York Mar 12, 09 Boarding - Agency Action Complete
3431410 STATEN ISLAND, New York Mar 11, 09 Vessel Inspection - Approved Inspection
3238693 STATEN ISLAND, New York Jun 17, 08 Boarding - Agency Action Complete
3152178 CORPUS CHRISTI, Texas Mar 01, 08 Vessel Inspection - Approved Inspection
3076394 NEW HAVEN, Connecticut Oct 09, 07 Vessel Transfer Monitor - Agency Action Complete
2915696 STATEN ISLAND, New York Apr 25, 07 Boarding - Agency Action Complete
2848113 STATEN ISLAND, New York Dec 30, 06 Vessel Inspection - Approved Inspection
2848163 STATEN ISLAND, New York Dec 30, 06 Boarding - Agency Action Complete
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel November 4,2013 November 4,2015 N/A
Classification Document January 19,2017 October 29,2021 LR
COC-TVE Annual November 7,2014 November 4,2015 N/A
COC-TVE Renewal November 4,2013 November 4,2015 USCG
International Load Line Certificate January 19,2017 October 29,2021 LR
International Oil Pollution Prevention Certificate March 19,2018 October 29,2021 LR
ISM - Document Of Compliance May 30,2013 October 5,2017 LR
ISM - Safety Management Certificate February 12,2017 March 5,2022 LR
Minimum Safe Manning Document November 8,2016 LR
SOLAS Cargo Ship Safety Construction Certificate January 19,2017 October 29,2021 LR
SOLAS Cargo Ship Safety Equipment Certificate September 22,2018 October 29,2021 LR
SOLAS Cargo Ship Safety Radio Certificate January 16,2017 October 29,2021 LR
Tonnage Certificate, International September 20,2006 LR