Stolt Kiri
Print Q88   
IMO/VIN Callsign Flag Service Year
9266231 D5MW8 LIBERIA Tank Ship 2003
Activity# Port Date Activity - Description Deficiencies
7254761 Houston, Texas Jul 19, 21 Vessel Inspection - Approved Inspection
6999366 New Orleans, Louisiana Jul 14, 20 Vessel Inspection - Approved Inspection
6836342 Houston, Texas Oct 17, 19 Vessel Inspection - Approved Inspection
6763880 Houston, Texas Aug 01, 19 Vessel Inspection - Approved Inspection
6766115 Houston, Texas Jul 29, 19 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
02 - Structural ConditionsN/A - No SubsystemDamaged By Earlier Event
DescriptionDue DateResolved
EACH SEPERATE CIRCUIT SHALL BE PROTECTED AGAINST SHORT CIRCUIT AND AGAINST OVERLOAD. THE PRIMARY FAN BREAKER WASTED, BURNING WIRES IN THE LOCAL CONTROL PANEL OF THE BOILER.Yes
Resolved DateResolution
Jul 30, 19Received, reviewed and accepted class report / proper documentation from class (LR), Master and C/E stating the deficiency was rectified. Faulty electrical breakers installed, tested satisfactory.
6676764 Houston, Texas May 04, 19 Vessel Inspection - Approved Inspection
6505390 PHILADELPHIA, Pennsylvania Aug 09, 18 Vessel Inspection - Agency Action Complete
  2
SystemSubsystemCause
12 - Dangerous GoodsN/A - No Subsystem
DescriptionDue DateResolved
01 12105 IBC CODE 7.1.5 50AC MEANS SHALL BE PROVIDED FOR MEASURING THE CARGO TEMPERATURE. PSCO OBSERVED THE 7P CARGO TANK TEMPERATURE SENSOR INOP. VESSEL RESTRICTED FROM LOADING HEATED CARGO IN 7P TANK UNTIL SENSORS ARE REPAIRED.Yes
Resolved DateResolution
Aug 21, 18Sensor was repaired. See attached documentation.
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No Subsystem
DescriptionDue DateResolved
02 06106 IBC CODE 10.2 10C ALL GASKETED CARGO-PIPE JOINTS AND HOSE CONNECTIONS SHALL BE ELECTRONICALLY BONDED. MULTIPLE ELECTRICAL BONDING STRIPS WERE MISSING FROM FLANGES ON STARBOARD MANIFOLD.Yes
Resolved DateResolution
Aug 09, 18
6276881 Victoria, Texas Sep 26, 17 Vessel Inspection - Approved Inspection
6061111 TEXAS CITY, Texas Dec 21, 16 Vessel Inspection - Approved Inspection
6084121 WASHINGTON, District of Columbia Dec 06, 16 Incident Investigation - Agency Action Complete
6039712 TEXAS CITY, Texas Nov 18, 16 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
LifesavingLifeboat Equipment
DescriptionDue DateResolved
FOOD RATIONS TOTALING NOT LESS THAN 10,000KJ FOR EACH PERSON THE LIFEBOAT IS PERMITTED TO ACCODATE, THESE RATIONS SHALL BE KEPT IN AIRTIGHT PACKAGING AND BE STOWED IN A WATERTIGHT CONTAINER. PSCO DISCOVERED 13 NON AIRTIGHT FOOD RATIONS.74 SOLAS (14)III/13.1.4 LSA CODE 4.4.8.12Dec 02, 16Yes
Resolved DateResolution
Nov 22, 16Received satisfactory documentation showing a purchase order and photos of new lifeboat rations.
5990733 New Orleans, Louisiana Sep 03, 16 Vessel Inspection - Approved Inspection
5799412 Houston, Texas Jan 19, 16 Vessel Inspection - Approved Inspection
5735961 STATEN ISLAND, New York Oct 05, 15 Vessel Inspection - Approved Inspection
  3
SystemSubsystemCause
EngineeringSteam System (auxiliary)Improper/Lack of Maintenance
DescriptionDue DateResolved
[40a]74SOLAS(04)II-1/32.4--Every steam generating system which provides services essential for the safety of the ship, or which could be rendered dangerous by the failure of its feedwater supply shall be provided with not less than two separate feedwater systems from and including the feed water pumps. One of the feedwater pumps for the steam system was wasted and unserviceable.Yes
Resolved DateResolution
Jan 19, 16Deficiency rectified to the satisfaction of attending class surveyor.
SystemSubsystemCause
ElectricalLighting (service)Improper Installation
DescriptionDue DateResolved
[40a]74SOLAS(04)II-1/45.5.6--Terminations and joints in all conductors shall be so made as to retain the original electrical, mechanical, flame-retarding and, fire-resisting properties of the cable. Lighting ballasts were installed without the use of junction boxes and were being held together with electrical tape.Yes
Resolved DateResolution
Jan 19, 16Deficiency rectified to the satisfaction of attending class surveyor.
SystemSubsystemCause
Fire FightingStructural Fire Protection - GeneralImproper/Lack of Maintenance
DescriptionDue DateResolved
[40a]74SOLAS(14)/14.2.1.1-Structural fire protection, including fire resisting divisions, and protections of openings and penetrations in these divisions shall be kept in good order. The A-Boundary outside the Em. escape to the E-room was deteriorated. Several A-class door-closers were not working as designed.Yes
Resolved DateResolution
Jan 19, 16Deficiency rectified to the satisfaction of attending class surveyor.
5028960 STATEN ISLAND, New York Nov 24, 14 Vessel Operational Control - Agency Action Complete
5068816 WASHINGTON, District of Columbia Oct 01, 14 Incident Investigation - Agency Action Complete
4976034 TEXAS CITY, Texas Sep 17, 14 Vessel Inspection - Approved Inspection
4899091 Savannah, Georgia Jun 25, 14 Vessel Inspection - Approved Inspection
4796368 New Orleans, Louisiana Feb 08, 14 Vessel Operational Control - Agency Action Complete
4796516 New Orleans, Louisiana Feb 07, 14 Vessel Inspection - Administrative Action
  1
SystemSubsystemCause
EngineeringSteering Gear System
DescriptionDue DateResolved
The vessel experienced a steering loss while in the Mississippi River due to a failed steering gear pump.Feb 07, 14Yes
Resolved DateResolution
Feb 08, 14Received, reviewed, and accepted class report from LR stating the steering gear was repaired, tested, and found satisfactory.
4797193 WASHINGTON, District of Columbia Feb 07, 14 Incident Investigation - Agency Action Complete
4713005 Houston, Texas Sep 12, 13 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
EngineeringDiesel Engine (propulsion-direct drive)Improper/Lack of Maintenance
DescriptionDue DateResolved
1410-Loss of Propulsion-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Vessel experienced loss of astern propulsion due to low fluid level in camshaft shifting gear.74 SOLAS (09) I/ 11(a) Sep 12, 13Yes
Resolved DateResolution
Sep 12, 13Vessel made satisfactory repairs and submitted class report.
4721967 WASHINGTON, District of Columbia Sep 11, 13 Incident Investigation - Agency Action Complete
4699325 STATEN ISLAND, New York Aug 29, 13 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
LifesavingLifeboat EquipmentPlaced in Improper Service
DescriptionDue DateResolved
0611- Lifesaving Equipment- Lifeboat shall consist of a food ration for each person the lifeboat is permitted to accommodate. Nine food rations were found with no vacuum seal and no replacements onboard. Must receive food rations prior to departure to satisfaction of CG. -74 SOLAS 09 III/13.1.4 LSA 4.4.8.12Yes
Resolved DateResolution
Aug 30, 13Received, reviewed, and accepted a receipt signed by the Captain of the vessel stating that 10 food rations have been delivered to the ship meeting the requirements of 74 SOLAS 09 III/13.1.4 and LSA 4.4.8.12.
4533210 WASHINGTON, District of Columbia Feb 14, 13 Incident Investigation - Agency Action Complete
4512830 STATEN ISLAND, New York Jan 08, 13 Vessel Operational Control - Agency Action Complete
4395777 Savannah, Georgia Aug 06, 12 Vessel Inspection - Approved Inspection
4284665 TEXAS CITY, Texas Apr 11, 12 Vessel Transfer Monitor - Agency Action Complete
4122208 PHILADELPHIA, Pennsylvania Aug 21, 11 Vessel Inspection - Approved Inspection
3917249 TEXAS CITY, Texas Dec 29, 10 Vessel Operational Control - Approved Inspection
  1
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
Vessel was involved in an allision. Vessel must submit a class report attesting to the material condition of the vessels hull.Yes
Resolved DateResolution
Dec 29, 10Received class report stating no repairs are required at this time and no conditions of class will be raised.
3926899 WASHINGTON, District of Columbia Dec 29, 10 Incident Investigation - Agency Action Complete
3875673 Houston, Texas Oct 22, 10 Enforcement - Agency Action Complete
3875639 Houston, Texas Oct 22, 10 Vessel Operational Control - Agency Action Complete
  1
SystemSubsystemCause
Operations/ManagementCargo Transfer/Lightering
DescriptionDue DateResolved
During transfer, the vessel did not notify the barge to slow transfer rate when the high level alarm sounded.Yes
Resolved DateResolution
Dec 13, 10
3852314 Savannah, Georgia Sep 27, 10 Vessel Inspection - Approved Inspection
3575199 PHILADELPHIA, Pennsylvania Aug 24, 09 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
LifesavingLifeboat EquipmentUnknown
DescriptionDue DateResolved
0611-Lifeboat Inventory-Anti-seasickness medication is a required item in lifeboat inventory for both port and starboard lifeboats. Enough inventory is required for 48 hours for each crewmember. Vessel's port and starboard lifeboats are missing anti-seasickness medicine. 74 SOLAS (2004 Cons Ed) Ch III Reg 13.1.4, LSA Code (2003 Ed) Reg 4.4.8.21Yes
Resolved DateResolution
Aug 24, 09Sector Delaware Bay received a delivery receipt from the vessel''s agent for delivery of 10 dozen sea sick tablets. (Scanned into MISLE)
3414911 Houston, Texas Feb 09, 09 Enforcement - Payment Received
3414610 WASHINGTON, District of Columbia Feb 05, 09 Incident Investigation - Agency Action Complete
3401603 Wilmington, North Carolina Jan 29, 09 Vessel Inspection - Agency Action Complete
3364244 STATEN ISLAND, New York Nov 16, 08 Vessel Operational Control - Agency Action Complete
3322662 New Orleans, Louisiana Sep 19, 08 Vessel Inspection - Approved Inspection
3170254 Houston, Texas Mar 24, 08 Enforcement - Payment Received
3168757 WASHINGTON, District of Columbia Mar 21, 08 Incident Investigation - Agency Action Complete
3155200 PHILADELPHIA, Pennsylvania Feb 28, 08 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Operations/ManagementPollutionUnknown
DescriptionDue DateResolved
Person in charge did not follow the vessels procedure and arrangement manual in regard to conducting a prewash of a Cat X Cargo discharged in previous port. Vessel must develop and submit a discharge plan proposal to the satisfaction of CG prior to departure.Feb 28, 08Yes
Resolved DateResolution
Feb 29, 08Vsl submitted discharge plan for vsl. Plan was reviewed and accepted satisfactory by USCG.
3108646 Savannah, Georgia Dec 03, 07 Vessel Transfer Monitor - Approved Inspection
3073605 Port Arthur, Texas Oct 02, 07 Vessel Inspection - Approved Inspection
3053978 PHILADELPHIA, Pennsylvania Sep 10, 07 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Fire FightingSelf-contained Breathing Apparatus
DescriptionDue DateResolved
While conducting a fire drill it was found that 02 SCBA's are leaking oxygen from the seal between the tank and the hose. Vessel must have SCBA's serviced.Sep 17, 07Yes
Resolved DateResolution
Oct 02, 07This unit attended subject vessel; viewed technician''s report. Cleared 01 deficiency for innoperative SCBA''s.
2884721 New Orleans, Louisiana Mar 09, 07 Vessel Inspection - Administrative Action
2788160 STATEN ISLAND, New York Sep 27, 06 Vessel Inspection - Approved Inspection
2656552 STATEN ISLAND, New York May 23, 06 Vessel Inspection - Approved Inspection
2653625 Houston, Texas May 19, 06 Vessel Inspection - Agency Action Complete
2571322 Houston, Texas Jan 23, 06 Vessel Transfer Monitor - Agency Action Complete
2483189 Savannah, Georgia Sep 01, 05 Vessel Inspection - Agency Action Complete
2116407 BATON ROUGE, Louisiana Jun 30, 04 Vessel Inspection - Approved Inspection
2063083 CORPUS CHRISTI, Texas May 09, 04 Boarding - Agency Action Complete
2050683 ST PETERSBURG, Florida Apr 23, 04 Vessel Inspection - Approved Inspection
2050683 Tampa, Florida Apr 23, 04 Vessel Inspection - Approved Inspection
1983025 Houston, Texas Jan 09, 04 Boarding - Agency Action Complete
1949381 Houston, Texas Nov 17, 03 Vessel Transfer Monitor - Approved Inspection
1883568 New Orleans, Louisiana Aug 20, 03 Vessel Operational Control - Administrative Action
1780030 Savannah, Georgia Apr 24, 03 Vessel Inspection - Approved Inspection
1768929 New Orleans, Louisiana Apr 06, 03 Vessel Inspection - Approved Inspection
1768600 Houston, Texas Apr 05, 03 Vessel Inspection - Agency Action Complete
1766178 New Orleans, Louisiana Mar 31, 03 Vessel Operational Control - Administrative Action
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel August 21,2011 August 21,2013 N/A
Certificate of Fitness - Chemical Carrier June 5,2020 January 27,2023 LR
Classification Document January 29,2008 January 28,2013 LR
International Certificate of Fitness - Chemical June 6,2014 January 27,2018 LR
International Load Line Certificate January 29,2008 January 28,2013 LR
International Oil Pollution Prevention Certificate January 22,2009 January 28,2013 LR
ISM - Document Of Compliance May 24,2005 May 19,2010 DNV
ISM - Safety Management Certificate July 5,2016 September 13,2021 LR
Minimum Safe Manning Document August 18,2017 LR
SOLAS Cargo Ship Safety Construction Certificate January 29,2008 January 28,2013 LR
SOLAS Cargo Ship Safety Equipment Certificate January 29,2008 January 28,2013 LR
SOLAS Cargo Ship Safety Radio Certificate January 29,2008 January 28,2013 LR
Tonnage Certificate, International September 19,2017 LR