Nave Cielo
Print Q88   
IMO/VIN Callsign Flag Service Year
9301976 ZCTC3 CAYMAN ISLANDS Tank Ship 2007
Activity# Port Date Activity - Description Deficiencies
6455111 Houston, Texas Jun 25, 18 Vessel Inspection - Approved Inspection
6432000 Houston, Texas Jun 02, 18 Vessel Inspection - Approved Inspection
6400920 Houston, Texas Apr 28, 18 Vessel Inspection - Approved Inspection
6392317 New Orleans, Louisiana Apr 16, 18 Vessel Inspection - Administrative Action
6351729 New Orleans, Louisiana Feb 17, 18 Vessel Inspection - Approved Inspection
6321508 PHILADELPHIA, Pennsylvania Dec 09, 17 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Construction/LoadlineHullPlaced in Improper Service
DescriptionDue DateResolved
Vessel reported grounding: See General Information.Yes
Resolved DateResolution
Dec 18, 17Recieved ABS Class Report; See General Information and attached document in Documents section.
6317956 PHILADELPHIA, Pennsylvania Dec 05, 17 Vessel Inspection - Approved Inspection
  6
SystemSubsystemCause
LifesavingLifeboat EquipmentDamaged By Earlier Event
DescriptionDue DateResolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the code. Except for free fall lifeboats, sufficient oars to make headway in calm sea shall be provided. PSCO observed a broken oar in port side of the boat. 74 SOLAS (14) Ch. III/ Reg 34. LSA 4.4.8.1. 16acDec 18, 17Yes
Resolved DateResolution
Dec 23, 17A new oar was provided and verified by ABS
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
Any failure of the oil discharge monitor and control system shall be noted in the Oil Record Book part II. ODME log displays sensor error on multiple locations including 02NOV17 and 30OCT17. These failures are not noted in the Oil Record Book Part II. Provide technician's report attesting to proper operation of ODME Oil Content Meter and associated sensors. MARPOL I/36.6, 17acYes
Resolved DateResolution
Dec 23, 17ODME Technician's report provided attesting to satisfactory repairs and testing of ODME.
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)Damaged By Earlier Event
DescriptionDue DateResolved
In tankers, cargo pumps shall be fitted with temperature sensing device for bearings and pum p cases. A continuous audible and visual alarm shall automatically be effected in cargo control or the pump control station.Cargo pump bearing temperature sensors are not functional on all three cargo pumps. 74 SOLAS (14) CH. II-2/ Reg 4.5.10.1.1. 40acFeb 28, 18Yes
Resolved DateResolution
Apr 27, 18Repairs made to satisfaction of RO.
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
In the event of failure of the ODME, a manually operated alternative method may be used, but the defective unit shall be made operable as soon as possible. According to the records, the ODME flow rate has been entered manually since Jan of 2016. MARPOL I/31.2Yes
Resolved DateResolution
Dec 23, 17Training was conducted with all crewmwmbers regarding the ODME and operation in manual mode. The vessel was also provided with procedures for notifying the company should be ODME need to be operated with manual inputs.
SystemSubsystemCause
Operations/ManagementVessel Safety Management
DescriptionDue DateResolved
The company and ship shall comply with the requirements of the ISM code. For purposes of this regulation, the requirements of the code shall be treated as mandatory. In meeting these requirements the company should ensure that any non conformity is reported with its possible cause, if known. Pollution control equipment (ODME) was not operated properly as indicated by incorrect flow rates. Additionally equipment was being operated with manual flow rates entered. Cargo pump bearing temperature sensors were observed not operational. Temporary thermostats were fitted to bearings. No reports were made to the RO. A ISM audit is recommended. 74SOLAS(14) IX/3.1 ISM 10.2.2Yes
Resolved DateResolution
Dec 23, 17ABS conducted an external ISM audit on behalf of the Administration (Cayman Islands).
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
The System shall be fitted with a recording device to provide a continuous record of the discharge in liters per nautical mile and total quantity discharged of the oil content and rare of discharge. ODME was not operational and failed to operate on multiple attempts when presented to PSC for examination. Flow meter does not show accurate rate of discharge. MARPOL/I.31.2Yes
Resolved DateResolution
Dec 23, 17A new flow sensor was installed in a new location as approved by ABS and a certified OEM technician.
6285185 New Orleans, Louisiana Oct 11, 17 Vessel Operational Control - Agency Action Complete
6168174 San Francisco, California Jun 08, 17 Vessel Inspection - Approved Inspection
  5
SystemSubsystemCause
EngineeringFreshwater System (intermediary cooling)Improper/Lack of Maintenance
DescriptionDue DateResolved
2550: After any survey of the ship has been completed, no change shall be made in the structural arrangement, machinery, and equipment without the sanction of the administration. The main engine seawater to fresh water cooler line has multiple large patches and leaks resulting from corrosion and paint failure. IGS Blower #1 was found to have pin hole leaks, 74 SOLAS (14 Ccon) 1/11, 17(a)(c).Yes
Resolved DateResolution
Jun 10, 17Addressed and corrected to the satisfaction of the attending Classification Representative.
SystemSubsystemCause
DocumentationLogs/RecordsImproper/Lack of Maintenance
DescriptionDue DateResolved
2120: Every ship of 100GT shall carry a Garbage Management Plan, which the crew shall follow. The plan shall provide written procedures for collecting, storing, processing, and disposing of garbage. Crew is not following vessel's garbage plans resulting in mixed garbage with food waste at eh final collection point. Vessel has discharged food waster appearing to be contaminated by, see narrative.Jun 08, 17Yes
Resolved DateResolution
Jun 08, 17Discussed procedures with Captain, Chief Officer, Chief Engineer, Chief Cook and Bos'n.
SystemSubsystemCause
Operations/ManagementCargo Transfer/LighteringImproper/Lack of Maintenance
DescriptionDue DateResolved
2510: The operator of a vessel with a capacity of 250 or more barrels of oil shall provide transfer procedures for transferring to or from the vessel and from tank to tank within the vessel. Vessel transfer procedures do not include necessary detains regarding personnel duties and cargo hazards, 33CFR155.720, 10(c).Jun 08, 17Yes
Resolved DateResolution
Jun 08, 17Reviewed procedures with Captain and Chief Officer. Gave crew guidance on procedures requirements plus handout.
SystemSubsystemCause
DocumentationLogs/RecordsImproper/Lack of Maintenance
DescriptionDue DateResolved
2510: Vessel must maintain a Ballast Water Management Plan that includes detailed fouling maintenance and sediment removal procedures and detailed reporting requirements and procedures. Vessel in not maintaining a Bio-Fouling Plan and Ballast Water Management Plan does not refer to sediment removal precedes. BWM Plan lacks references to necessary logs, 33CFR151.2050(g)(3+(6), 40c).Jun 23, 17Yes
Resolved DateResolution
Jun 10, 17Addressed and corrected to the satisfaction of the attending Classification Representative.
SystemSubsystemCause
EngineeringFuel Oil Storage/Transfer SystemImproper/Lack of Maintenance
DescriptionDue DateResolved
2550: After any survey of the ship has been completed, no change shall be made in the structural arrangement, machinery, and equipment without the sanction of the administration. Waste Oil Tank #1 has been modified to all evaporation and changes have not been approved, 74 SOOLAS (14 con) 1/11, 17(a)c).Yes
Resolved DateResolution
Jun 10, 17Addressed and corrected to the satisfaction of the attending Classification Representative.
6073969 New Orleans, Louisiana Jan 20, 17 Vessel Inspection - Approved Inspection
5815765 Savannah, Georgia Feb 16, 16 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Deck/CargoInert Gas SystemImproper/Lack of Maintenance
DescriptionDue DateResolved
1850-Arrangements for purging &/or gas freeing shall be such as to minimize the hazards due to dispersal of flammable vapors in the atmosphere & to the flammable mixtures in a cargo tank. PSCO observed the No. 2 fan outlet valve to remain in the closed position while attempting to conduct a blower failure test. No. 2 fan outlet valve is automated. SOLAS (04) II-2/4.5.6.1 17acFeb 17, 16Yes
Resolved DateResolution
Feb 17, 16Received class report.
SystemSubsystemCause
Deck/CargoInert Gas SystemImproper/Lack of Maintenance
DescriptionDue DateResolved
1850-Arrangements for purging &/or gas freeing shall be such as to minimize the hazards due to dispersal of flammable vapors in the atmosphere & to the flammable mixtures in a cargo tank. PSCO observed the scrubber for their IGS in way of the sight glass to have a hole approximately 2 in long by 1 in wide. Prove proper operation & repairs to the attending class surveyor. SOLAS (04) II-2/4.5.6.1Feb 17, 16Yes
Resolved DateResolution
Feb 17, 16Received class report.
5815265 North Charleston, South Carolina Feb 15, 16 Vessel Operational Control - Agency Action Complete
5802312 New Orleans, Louisiana Jan 24, 16 Vessel Operational Control - Agency Action Complete
5798907 New Orleans, Louisiana Jan 17, 16 Vessel Inspection - Administrative Action
5746575 TEXAS CITY, Texas Oct 16, 15 Vessel Inspection - Approved Inspection
5080168 New Orleans, Louisiana Mar 09, 15 Vessel Inspection - Approved Inspection
4790200 San Pedro, California Feb 01, 14 Vessel Inspection - Approved Inspection
4789906 San Diego, California Jan 27, 14 Vessel Inspection - Approved Inspection
4728445 San Diego, California Oct 03, 13 Vessel Inspection - Approved Inspection
4525899 Miami Beach, Florida Feb 02, 13 Vessel Inspection - Approved Inspection
4272261 TEXAS CITY, Texas Apr 09, 12 Vessel Inspection - Approved Inspection
4249699 San Juan, Puerto Rico Feb 23, 12 Vessel Transfer Monitor - Approved Inspection
4216940 San Juan, Puerto Rico Jan 12, 12 Vessel Inspection - Approved Inspection
3928040 STATEN ISLAND, New York Jan 18, 11 Vessel Inspection - Approved Inspection
3418096 San Pedro, California Feb 15, 09 Boarding - Agency Action Complete
3417486 San Pedro, California Feb 13, 09 Vessel Operational Control - Agency Action Complete
3367711 New Orleans, Louisiana Nov 22, 08 Vessel Inspection - Administrative Action
3345337 PHILADELPHIA, Pennsylvania Oct 16, 08 Vessel Inspection - Approved Inspection
3128177 Savannah, Georgia Jan 10, 08 Vessel Inspection - Agency Action Complete
  2
SystemSubsystemCause
Pollution Prevention/ResponsePrevention EquipmentUnknown
DescriptionDue DateResolved
Oil like substance was discovered on the vessel 's hull leading to the ODEM discharge opening. In addition upon review of the ODME electronic log a manual override of the ODME was conducted on the 12OCT07 which directly conflicts with the system manual. Vessel required to have attending classification society surveyor conduct full function test and attest crew competence.Jan 12, 08Yes
Resolved DateResolution
Jan 12, 08Received satisfactory class report attesting to the operation of the vessel''s ODME and attested to the crews comprehension of the ODME system.
SystemSubsystemCause
Pollution Prevention/ResponseResponse Equipment
DescriptionDue DateResolved
Vessel must properly clean and dispose of the oil like subtsance found on the vessel's hull prior to depature.Jan 12, 08Yes
Resolved DateResolution
Jan 12, 08Vessel cleaned and properly disposed of oil like substance found on the vessel''''s hull.
3075391 Mobile, Alabama Oct 08, 07 Vessel Inspection - Approved Inspection
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel January 18,2011 January 18,2013 USCG
Classification Document August 25,2016 June 12,2017 ABS
COC-TVE Annual October 16,2008 October 12,2009 N/A
COC-TVE Renewal October 8,2007 October 12,2009 N/A
International Load Line Certificate June 12,2012 June 12,2017 ABS
International Oil Pollution Prevention Certificate July 17,2013 June 12,2017 ABS
ISM - Document Of Compliance October 17,2016 October 30,2021 KY
ISM - Safety Management Certificate November 8,2012 October 14,2016 ABS
Load Line Certificate (Coastwise) October 24,2007 March 24,2008 ABS
Minimum Safe Manning Document July 10,2013 May 5,2018 KY
SOLAS Cargo Ship Safety Construction Certificate July 31,2012 June 12,2017 ABS
SOLAS Cargo Ship Safety Equipment Certificate July 17,2013 June 12,2017 ABS
SOLAS Cargo Ship Safety Radio Certificate July 31,2012 June 12,2017 ABS
Tonnage Certificate, International July 25,2012 ABS