Thun Blyth
Print Q88   
IMO/VIN Callsign Flag Service Year
9224130 PBLM NETHERLANDS Freight Ship 2000
Activity# Port Date Activity - Description Deficiencies
6613151 New Orleans, Louisiana Feb 03, 19 Vessel Inspection - Approved Inspection
5867068 New Orleans, Louisiana May 02, 16 Vessel Inspection - Approved Inspection
5738576 ATLANTIC BEACH, North Carolina Oct 08, 15 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
LifesavingVisual Distress Signals (General)
DescriptionDue DateResolved
All pyrotechnics (visual distress signals) for bridge and lifeboat are expired.Yes
Resolved DateResolution
Oct 10, 15Received Class NK report attesting to replacement of all required VDS.
SystemSubsystemCause
LifesavingInflatable LiferaftsDamaged By Earlier Event
DescriptionDue DateResolved
Forward liferaft container damaged/compromised during severe weather.Yes
Resolved DateResolution
Oct 10, 15Received NK Class report attesting to replacement of raft.
4880611 Houston, Texas Jul 01, 14 Vessel Inspection - Approved Inspection
4875218 TEXAS CITY, Texas May 31, 14 Boarding - Agency Action Complete
4873381 New Orleans, Louisiana May 29, 14 Vessel Inspection - Administrative Action
4841074 New Orleans, Louisiana Apr 28, 14 Vessel Inspection - Approved Inspection
  7
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational Safety
DescriptionDue DateResolved
0730 - Appliances (general) - Fire protection systems and fire-fighting systems and appliances shall be maintained and ready for use. PSCO observed accumulator which controls the pneumatic quick closing valves empty. C/E stated that it, "Must always have air". He could not provide any procedures. Provide operating procedures from company. SOLAS 74 (a) CH II-2/14May 12, 14Yes
Resolved DateResolution
Jul 01, 14Received class report stating that the written procedures, and a secondary foot pump have been provided to the vessel.
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
0750 - Fire Prevention - The arrangements for the storage, distribution and use of oil used in pressure lubrication systems shall be such to ensure the safety of persons onboard. PSCE observed dirty and clean oil drums being stored in the bosun hole. Provide clarification from company authorizing this as a storage location. SOLAS 97 CONS. II-2/15Yes
Resolved DateResolution
Jun 01, 14Received class report from Lloyd''s Register satisfying requirement.
SystemSubsystemCause
ElectricalElectric Generation Source (service)
DescriptionDue DateResolved
0950 - Electrical equipment in general - Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. PSCE observed water leaking from electrical cables penetrating a bulkhead in the CO2 compartment. Rectify to the satisfaction of certificate issuing authority. SOLAS 97 CONS. II-1/40Yes
Resolved DateResolution
Jun 01, 14Received class report from Lloyd''s Register satisfying requirement.
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational Safety
DescriptionDue DateResolved
0999 - other (safety in general) - Efficient guard rails or bulwarks shall be fitted to all exposed parts of the freeboard and superstructure decks. PSCO identified several missing, wasted and broken rails on port and stbd side of vessel. Repair to satisfaction of certificates issuing authority. ILLC, 2005, ANNEX I CH III/25Yes
Resolved DateResolution
Jun 01, 14Received class report from Lloyd''s Register satisfying requirement.
SystemSubsystemCause
ElectricalElectric Generation Source (emergency)
DescriptionDue DateResolved
1430 - aux engines - Second source of energy shall be provided for an additional 03 starts. C/E had never used spring start to turn over emergency generator. Provide corrective action plan attesting to familiarity and starting of emergency generator. SOLAS 97 CONS. CH II-1/44Yes
Resolved DateResolution
Jul 01, 14Received class report attesting to a corrective action plan, and increased familiarity with the second means of starting with the ship''s emergency generator.
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational Safety
DescriptionDue DateResolved
1430 - Auxiliary engines - Steering gear compartments shall be provided with non slip surface, in the event of hydraulic fuel leakage. PSCO noted that the walking area in steering room is slippery and there is no grating or slip resistant matting/surface. Rectify to satisfaction of certificate issuing authority. SOLAS 97 CONS. II-1/29Yes
Resolved DateResolution
Jun 01, 14Received class report from Lloyd''s Register satisfying requirement.
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational Safety
DescriptionDue DateResolved
1499 - Other prop. and Aux. Machinery - Machinery, boiler and other pressure vessels, associated piping systems and fitting shall be of design an construction adequate for the service for which they are intended. PSCE observed excessive hydraulic oil leaking from #1 loading crane while in use. Repair to satisfaction of cert. issuing authority. SOLAS 97 CONS. II-1/26May 28, 14Yes
Resolved DateResolution
Jun 01, 14Received class report from Lloyd''s Register satisfying requirement.
4841076 New Orleans, Louisiana Apr 27, 14 Boarding - Agency Action Complete
4455595 Mobile, Alabama Oct 10, 12 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
LifesavingRescue BoatImproper/Lack of Maintenance
DescriptionDue DateResolved
0615 - RESCUE BOATS - ALL ITEMS OF THE RESCUE BOAT EQUIPMENT, WITH THE EXCEPTION OF BOAT HOOKS, WHICH SHALL BE KEPT FREE FOR FENDING OFF PURPOSE, SHALL BE SECURED WITHIN THE RESCUE BOAT BY LASHING, STORAGE LOCKER OR COMPARTMENT. THE PSCO WITNESSED THE FORWARD COMPARTMENT WAS FILLED WITH WATER AND THE RESCUE BOAT EQUIPMENT WAS NOT WITHIN THE RESCUE BOAT - 74 SOLAS (97) CHAP III/47.2.1 50(a)(c)Nov 09, 12Yes
Resolved DateResolution
Apr 28, 14Received GL report satisfying the requirement
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational SafetyDamaged By Earlier Event
DescriptionDue DateResolved
1230 - RAILING CAT WALKS - EFFICIENT GUARD RAILS OR BULWARKS SHALL BE FITTED TO ALL EXPOSED PARTS OF THE FREEBOARD AND SUPERSTRUCTURE DECKS. THE HEIGHT OF THE BULWARKS OR GUARDRAILS SHALL BE AT LEAST 1 METER (39.5 INCHES) FROM THE DECK. THE PSCO IDENTIFIED SEVERAL MISSING, WASTED AND BROKEN RAILS ON BOTH THE PORT AND STARBOARD SIDE OF THE VESSEL - ILLC, 2005 ED. REG 25/2. 50(a)(c)Nov 09, 12Yes
Resolved DateResolution
Apr 28, 14Received GL report satisfying the requirement.
4305226 ST PETERSBURG, Florida May 08, 12 Vessel Inspection - Approved Inspection
4305226 Tampa, Florida May 08, 12 Vessel Inspection - Approved Inspection
4305205 ST PETERSBURG, Florida May 08, 12 Vessel Inspection - Approved Inspection
4305205 Tampa, Florida May 08, 12 Vessel Inspection - Approved Inspection
4280058 New Orleans, Louisiana Apr 17, 12 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Operations/ManagementEPA Vessel General Permit (VGP)
DescriptionDue DateResolved
0199-Other (certificate)-The vessel master and senior crew on board could not produce a Vessel General Permit (VGP). PSCO instructed the master and crew that they must obtain and read the VGP. PSCO provided the master and crew with a copy of the EPA VGP fact sheet.- 33 USC 1251Apr 17, 12Yes
Resolved DateResolution
Apr 17, 12Deficiency rectified.
SystemSubsystemCause
LifesavingLifeboat Equipment
DescriptionDue DateResolved
0611-Lifeboat inventory-Food rations totaling not less than 10,000 kJ for each person the lifeboat is permitted to accommodate, shall be kept in an airtight package and be stowed in a watertight container. PSOC observed that 6 of the 12 required food rations were lacking an airtight seal.-SOLAS 74 (09 cons) III/20.7 & LSA Code IV/4.4.8.12Apr 20, 12Yes
Resolved DateResolution
May 09, 12
4184126 North Charleston, South Carolina Nov 12, 11 Vessel Inspection - Approved Inspection
  10
SystemSubsystemCause
PersonnelCertificates/Documents/Licenses
DescriptionDue DateResolved
0230 - Number/composition (manning) - Ships Chief Mate does not have a endorsement from Antigua and Barbuda accepting his Russian Mariners License. STCW Article VI (2)Yes
Resolved DateResolution
Nov 14, 11New Chief Mate is o/b and has valid License and Endorsement.
SystemSubsystemCause
LifesavingRescue Boat
DescriptionDue DateResolved
0615 - Rescue Boat - The rescue boat engine is not discharging water from the discharge port and is leaking excessive amounts of gear oil from the propeller. 97' SOLAS Chp. III Reg 19.2Yes
Resolved DateResolution
Nov 14, 11Engine is functioning properly. Repairs have been made.
SystemSubsystemCause
LifesavingInflatable Liferafts
DescriptionDue DateResolved
0620 - Inflatable Liferafts - The weak link and hydrostatic release were improperly installed on the Stbd side liferaft. The weak link and painter line were not attached to the vessel. 97' SOLAS Chp. III Reg 38.6Yes
Resolved DateResolution
Nov 13, 11Weak link and hydrostatic in correct positions.
SystemSubsystemCause
Fire FightingMiscellaneous Items
DescriptionDue DateResolved
0710 - Fire Prevention - Machinery shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons o/b. Excessive oil leaks from the M/E into the bilge and excessive fuel leaks from Aux Gen #3 pose fire hazard and risk to crew. 97' SOLAS Chp. II-1 Reg 26.1Yes
Resolved DateResolution
Nov 14, 11Leaks have been secured and fire hazards have been removed.
SystemSubsystemCause
Fire FightingMiscellaneous Items
DescriptionDue DateResolved
0710 - Fire Prevention - The portable fuel tanks for the rescue boat are being stored in a locker outside and behind the pilot house. There is no fixed fire fighting or detection for this space creating a fire hazard and risk to the crew. 09' SOLAS Chp. I Reg 11Yes
Resolved DateResolution
Nov 14, 11Portable fuel tanks have been moved to protected space.
SystemSubsystemCause
Fire FightingStructural - A Class Divisions
DescriptionDue DateResolved
0710 - Fire Prevention - The self-closing doors in the main stairwell are inoperable. All doors in main stairwell must be self-closing. 97' SOLAS Chp. II-2 Reg 46.1Yes
Resolved DateResolution
Nov 14, 11Fire doors have been adjusted and are working properly
SystemSubsystemCause
Fire FightingMiscellaneous Items
DescriptionDue DateResolved
0710 - Fire Prevention - The ship has a flammable paint locker located in the forepeak with a fixed fire fighting system yet all paint is being stored outside this space in the boatswains storage hold. The improperly stowed paint creates a fire hazard to the ship and crew. 09' SOLAS Chp. I Reg. 11Yes
Resolved DateResolution
Nov 14, 11All flammable materials have been moved into the Paint Locker.
SystemSubsystemCause
Fire FightingFire Main
DescriptionDue DateResolved
0720 - Fire Fighting Equipment - Fire-extinguishing appliances shall be kept in good order and be available for immediate use at all times. Fire main located on the Port side, near the aft cargo hold is holed and wasted. Temporary repairs have already been made and are not holding. Crop and renew in accordance with ships drawings. 97' SOLAS Chp. II-2 Reg 21Yes
Resolved DateResolution
Nov 20, 11
SystemSubsystemCause
Construction/LoadlineStructures
DescriptionDue DateResolved
0930 - Stability/Strength - Vessel has soft spots on 02 aft staiwell steps and deck in front of the sitting position on the starboard side of the navigational bridge. Class has surveyed areas. Stairwell soft spots will be repaired within 30 days and Bridge soft spot has received a temporary repair which will be renewed at their next drydock. See Class report attached.Dec 14, 11Yes
Resolved DateResolution
Nov 20, 11All work was completed at Detyens Shipyard.
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
1730 - OWS Equipment - Oil Filtering Equipment shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15 parts per million. 3 way valve is inconsistent and does not activate every time 15 parts per million is exceeded. Crew is not familiar with the operation of the system. MARPOL Annex I Reg 14.6Yes
Resolved DateResolution
Nov 14, 11OWS has been tested and is functioning properly. Crew is familiar with system.
4184516 North Charleston, South Carolina Nov 11, 11 Boarding - Agency Action Complete
3967434 ST PETERSBURG, Florida Mar 19, 11 Vessel Inspection - Approved Inspection
3967434 Tampa, Florida Mar 19, 11 Vessel Inspection - Approved Inspection
3893777 ST PETERSBURG, Florida Nov 18, 10 Vessel Inspection - Approved Inspection
3893777 Tampa, Florida Nov 18, 10 Vessel Inspection - Approved Inspection
3754852 Houston, Texas Jun 01, 10 Vessel Inspection - Approved Inspection
3656643 ST PETERSBURG, Florida Dec 30, 09 Vessel Inspection - Approved Inspection
3656643 Tampa, Florida Dec 30, 09 Vessel Inspection - Approved Inspection
3605675 ST PETERSBURG, Florida Sep 16, 09 Vessel Operational Control - Approved Inspection
3605675 Tampa, Florida Sep 16, 09 Vessel Operational Control - Approved Inspection
3595532 ST PETERSBURG, Florida Sep 16, 09 Boarding - Agency Action Complete
3595532 Tampa, Florida Sep 16, 09 Boarding - Agency Action Complete
3552151 ST PETERSBURG, Florida Aug 01, 09 Vessel Inspection - Approved Inspection
3552151 Tampa, Florida Aug 01, 09 Vessel Inspection - Approved Inspection
3489015 New Orleans, Louisiana May 28, 09 Vessel Inspection - Administrative Action
  1
SystemSubsystemCause
Deck/CargoMooring/Anchoring
DescriptionDue DateResolved
Vessel lost its Port Anchor.Yes
Resolved DateResolution
Aug 05, 09Received statment from Master attesting to replacement of Port Anchor.
3486192 New Orleans, Louisiana May 26, 09 Vessel Operational Control - Agency Action Complete
3480271 New Orleans, Louisiana May 25, 09 Vessel Inspection - Approved Inspection
3229621 North Charleston, South Carolina Jun 07, 08 Vessel Operational Control - Agency Action Complete
3224901 North Charleston, South Carolina Jun 02, 08 Vessel Inspection - Agency Action Complete
3224779 North Charleston, South Carolina Jun 02, 08 Boarding - Agency Action Complete
3193123 PHILADELPHIA, Pennsylvania Apr 27, 08 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
LifesavingEmbarkation Appliances/Stations
DescriptionDue DateResolved
Aft ladder from main deck embarkation area has holed treads.May 27, 08Yes
Resolved DateResolution
Jun 02, 08Steps on ladder have been replaced.
SystemSubsystemCause
ElectricalElectric Generation Source (emergency)
DescriptionDue DateResolved
Emergency generator starting batteries will not hold charge and consequently will not start engine.Apr 28, 08Yes
Resolved DateResolution
Apr 28, 08Received invoice with 02 lead acid batteries.
3165070 ST PETERSBURG, Florida Mar 15, 08 Vessel Operational Control - Agency Action Complete
3165070 Tampa, Florida Mar 15, 08 Vessel Operational Control - Agency Action Complete
3107885 ST PETERSBURG, Florida Dec 01, 07 Enforcement - Agency Action Complete
3107885 Tampa, Florida Dec 01, 07 Enforcement - Agency Action Complete
3107872 ST PETERSBURG, Florida Dec 01, 07 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Operations/ManagementMandatory Ship Reporting SystemsUnknown
DescriptionDue DateResolved
Vessel failed to submit proper ANOA to NVMC: crew member information was found to be wrong on the vessel during an enforcement boarding.Dec 01, 07Yes
Resolved DateResolution
Dec 01, 07
3107872 Tampa, Florida Dec 01, 07 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Operations/ManagementMandatory Ship Reporting SystemsUnknown
DescriptionDue DateResolved
Vessel failed to submit proper ANOA to NVMC: crew member information was found to be wrong on the vessel during an enforcement boarding.Dec 01, 07Yes
Resolved DateResolution
Dec 01, 07
3099244 Port Arthur, Texas Nov 15, 07 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
NavigationCollision/Grounding Avoidance
DescriptionDue DateResolved
Vessel agent requesting Letter of Deviation for an inoperable secondary radar. Approved request for one inbound transit with a requirement to effect permanent repairs to the radar prior to departing port.Nov 19, 07Yes
Resolved DateResolution
Nov 16, 07
3065876 ST PETERSBURG, Florida Sep 25, 07 Boarding - Agency Action Complete
3065876 Tampa, Florida Sep 25, 07 Boarding - Agency Action Complete
2940148 ST PETERSBURG, Florida May 25, 07 Vessel Inspection - Agency Action Complete
2940148 Tampa, Florida May 25, 07 Vessel Inspection - Agency Action Complete
2934107 Port Arthur, Texas May 18, 07 Vessel Inspection - Approved Inspection
2726416 Port Arthur, Texas Jul 27, 06 Boarding - Agency Action Complete
2657720 WASHINGTON, District of Columbia May 24, 06 Incident Investigation - Agency Action Complete
2650118 TEXAS CITY, Texas May 15, 06 Vessel Inspection - Approved Inspection
2555240 ST PETERSBURG, Florida Dec 22, 05 Vessel Inspection - Approved Inspection
2555240 Tampa, Florida Dec 22, 05 Vessel Inspection - Approved Inspection
2354812 ST PETERSBURG, Florida May 11, 05 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Operations/ManagementDrills/Instruction
DescriptionDue DateResolved
DUE TO TIME VESSEL DID NOT CONDUCT DRILLS. DUE NEXT TIME USMay 11, 05Yes
Resolved DateResolution
Dec 22, 05COMPLETED SATISFACTORY DRILLS
2354812 Tampa, Florida May 11, 05 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Operations/ManagementDrills/Instruction
DescriptionDue DateResolved
DUE TO TIME VESSEL DID NOT CONDUCT DRILLS. DUE NEXT TIME USMay 11, 05Yes
Resolved DateResolution
Dec 22, 05COMPLETED SATISFACTORY DRILLS
2314764 Port Arthur, Texas Mar 20, 05 Vessel Operational Control - Agency Action Complete
2314690 Port Arthur, Texas Mar 20, 05 Vessel Operational Control - Agency Action Complete
2275477 ST PETERSBURG, Florida Feb 22, 05 Vessel Inspection - Agency Action Complete
2275477 Tampa, Florida Feb 22, 05 Vessel Inspection - Agency Action Complete
2278228 ST PETERSBURG, Florida Jan 20, 05 Boarding - Agency Action Complete
2278228 Tampa, Florida Jan 20, 05 Boarding - Agency Action Complete
2211876 New Orleans, Louisiana Oct 02, 04 Vessel Operational Control - Administrative Action
2213059 ST PETERSBURG, Florida Sep 30, 04 Vessel Operational Control - Agency Action Complete
2213059 Tampa, Florida Sep 30, 04 Vessel Operational Control - Agency Action Complete
2211043 ST PETERSBURG, Florida Sep 30, 04 Vessel Inspection - Approved Inspection
2211043 Tampa, Florida Sep 30, 04 Vessel Inspection - Approved Inspection
2131310 ST PETERSBURG, Florida Jul 22, 04 Vessel Inspection - Approved Inspection
2131310 Tampa, Florida Jul 22, 04 Vessel Inspection - Approved Inspection
2064541 Portsmouth, Virginia May 11, 04 Vessel Inspection - Approved Inspection
1781947 North Charleston, South Carolina Apr 24, 03 Boarding - Agency Action Complete
1771110 New Orleans, Louisiana Apr 09, 03 Vessel Inspection - Approved Inspection
1681241 New Orleans, Louisiana Sep 27, 02 Vessel Inspection - Approved Inspection
1612590 ST PETERSBURG, Florida May 03, 02 Vessel Inspection - Approved Inspection
  4
SystemSubsystemCause
Pollution Prevention/ResponsePrevention EquipmentDamaged By Earlier Event
DescriptionDue DateResolved
OILY WATER SEPARATER WAS FOUND INOPERABLE. CREW WAITING FOR PART TO REPAIR RELAY SOLENOID. VESSEL TO KEEP ALL OILY WASTE/BILGE WATER ON BOARD FOR DISCHARGE TO AN APPROVED SHORESIDE FACILITY. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)May 04, 02Yes
Resolved DateResolution
Sep 28, 02Deficiency cleared by Germanischer Lloyd class report.
SystemSubsystemCause
DocumentationCertificates/DocumentsUnknown
DescriptionDue DateResolved
PROVIDE CLASS REPORT ADDRESSING ALL OUTSTANDING ITEMS NOTED BY MSO TAMMS DURING EXAM ON 03MAY2002. ATTEST TO COMPLETION/COMPLIANCE.May 04, 02Yes
Resolved DateResolution
Sep 27, 02Deficiency cleared during NEWMS re-inspection.
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational SafetyUnknown
DescriptionDue DateResolved
PROVIDE EMERGENCY ESCAPE PLACARD ON DOOR IN ENGINE ROOM AT DECK PLATE LEVEL, PORT SIDE.May 04, 02Yes
Resolved DateResolution
Sep 27, 02Deficiency cleared during NEWMS re-inspection.
SystemSubsystemCause
Fire FightingStructural - A Class DivisionsImproper Installation
DescriptionDue DateResolved
REMOVE HOLD BACK HOOK ON FIRE SCREEN DOOR LEADING TO STEERING GEAR SPACE ROOM FROM ENGINE SPACE. LEGACY COMPONENT DESC: Bulkheads - Machinery SpacesMay 04, 02Yes
Resolved DateResolution
Sep 27, 02Deficiency cleared during NEWMS re-inspection.
1612590 Tampa, Florida May 03, 02 Vessel Inspection - Approved Inspection
  4
SystemSubsystemCause
Pollution Prevention/ResponsePrevention EquipmentDamaged By Earlier Event
DescriptionDue DateResolved
OILY WATER SEPARATER WAS FOUND INOPERABLE. CREW WAITING FOR PART TO REPAIR RELAY SOLENOID. VESSEL TO KEEP ALL OILY WASTE/BILGE WATER ON BOARD FOR DISCHARGE TO AN APPROVED SHORESIDE FACILITY. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)May 04, 02Yes
Resolved DateResolution
Sep 28, 02Deficiency cleared by Germanischer Lloyd class report.
SystemSubsystemCause
DocumentationCertificates/DocumentsUnknown
DescriptionDue DateResolved
PROVIDE CLASS REPORT ADDRESSING ALL OUTSTANDING ITEMS NOTED BY MSO TAMMS DURING EXAM ON 03MAY2002. ATTEST TO COMPLETION/COMPLIANCE.May 04, 02Yes
Resolved DateResolution
Sep 27, 02Deficiency cleared during NEWMS re-inspection.
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational SafetyUnknown
DescriptionDue DateResolved
PROVIDE EMERGENCY ESCAPE PLACARD ON DOOR IN ENGINE ROOM AT DECK PLATE LEVEL, PORT SIDE.May 04, 02Yes
Resolved DateResolution
Sep 27, 02Deficiency cleared during NEWMS re-inspection.
SystemSubsystemCause
Fire FightingStructural - A Class DivisionsImproper Installation
DescriptionDue DateResolved
REMOVE HOLD BACK HOOK ON FIRE SCREEN DOOR LEADING TO STEERING GEAR SPACE ROOM FROM ENGINE SPACE. LEGACY COMPONENT DESC: Bulkheads - Machinery SpacesMay 04, 02Yes
Resolved DateResolution
Sep 27, 02Deficiency cleared during NEWMS re-inspection.
294349 Houston, Texas Oct 12, 01 Vessel Inspection - Agency Action Complete
290005 Houston, Texas Apr 23, 01 Vessel Inspection - Agency Action Complete
289265 Houston, Texas Apr 23, 01 Vessel Inspection - Agency Action Complete
280419 Baltimore, Maryland Jul 31, 00 Vessel Inspection - Agency Action Complete
Documents Issued Expires Agency
Classification Document February 3,2016 June 30,2020 NKK
International Load Line Certificate October 15,2015 June 30,2020 NKK
International Oil Pollution Prevention Certificate April 5,2012 September 4,2012 GL
ISM - Document Of Compliance March 3,2017 May 8,2021 LR
ISM - Safety Management Certificate October 14,2010 September 26,2015 DNV
Load Line Certificate (Coastwise) October 12,2001 January 11,2002 GL
Minimum Safe Manning Document June 13,2014 NL
SOLAS Cargo Ship Safety Certificate December 23,2018 June 30,2020 NKK
SOLAS Cargo Ship Safety Construction Certificate July 29,2010 June 30,2015 GL
SOLAS Cargo Ship Safety Equipment Certificate September 15,2012 November 14,2012 GL
SOLAS Cargo Ship Safety Radio Certificate July 29,2010 June 30,2015 GL
Tonnage Certificate, International January 14,2014 LR