Chemtrans Cancale
Print Q88   
IMO/VIN Callsign Flag Service Year
9372858 A8MO9 LIBERIA Tank Ship 2007
Activity# Port Date Activity - Description Deficiencies
7208508 Houma, Louisiana May 29, 21 Vessel Inspection - Approved Inspection
7046372 Houston, Texas Aug 31, 20 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
15 - Safety Management Systems (ISM)N/A - No SubsystemDesign Flaw
DescriptionDue DateResolved
The company should establish procedures to ensure that the ship is maintained in meeting these requirements. The company should ensure that 1. inspections are held at appropriate intervals 2. any non conformity is reported, with its possible cause, if known 3. Appropriate corrective action is taken; and 4. records of these activities are maintained. Crew could not provide inspection schedule for ODME overboard discharge valve. 74SOLAS14 IX/3.1 ISM Code 10.2 50acSep 30, 20Yes
Resolved DateResolution
Sep 04, 2004SEP20 - Sector Houston-Galveston received satisfactory SMS updates for inspection schedule for ODME overboard discharge valve. Deficiency cleared.
SystemSubsystemCause
14 - Pollution Prevention141 - MARPOL Annex IImproper/Lack of Maintenance
DescriptionDue DateResolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present convention to ensure that the ship in all respects will remain fit to proceed to sea without presenting an unreasonable threat of harm to the marine environment. ODME valve overboard caused slop to discharge at the dock. Marpol Annex I / 6.4.1 17acYes
Resolved DateResolution
Sep 03, 2003SEP20: Sector Houston-Galveston received satisfactory Class Report from Lloyd's Register attesting replacement of defective solenoid of the hydraulic valve.
7020049 Port Arthur, Texas Jul 30, 20 Vessel Inspection - Agency Action Complete
6968865 New Orleans, Louisiana Jun 05, 20 Vessel Inspection - Administrative Action
6904041 Houston, Texas Feb 06, 20 Vessel Inspection - Approved Inspection
6900718 New Orleans, Louisiana Feb 01, 20 Vessel Inspection - Approved Inspection
6878146 Christiansted, Virgin Islands Dec 25, 19 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
The machinery, boilers, and associated piping systems and fittings shall be installed and protected as to reduce to a minimum any danger to persons on board. During the pumproom exam, PSCO discovered 02 holes on casing of cargo pump #3, which had water leaking and previous temporary repairs made. Until repaired to the satisifaction of class, cargo pump #3 shall not be used for cargo operations. Cite: 74SOLAS(14) II-1/26.1 Action: 40acYes
Resolved DateResolution
Feb 06, 20Received report from Class LR attesting to satisfactory repairs of water leaks in #3 cargo pump casing.
3127839 Woods Hole, Massachusetts Jan 10, 08 Vessel Inspection - Approved Inspection
3124344 Baltimore, Maryland Jan 03, 08 Enforcement - Payment Received
3114931 NEW HAVEN, Connecticut Dec 13, 07 Vessel Transfer Monitor - Agency Action Complete
3113778 NEW HAVEN, Connecticut Dec 11, 07 Vessel Inspection - Agency Action Complete
3110648 Baltimore, Maryland Dec 07, 07 Vessel Inspection - Approved Inspection
  9
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
46CFR153.296(g) The on deck emergency shutdown stations are not marked with the legend "emergency shutdown." Legend must be visible from work areas in the part of the deck where the carrgo containment systems are located. Prove labelling to CG prior to next US port.Yes
Resolved DateResolution
Dec 13, 07Boarded vessel and witnessed satisfactory stencilling, visable in working areas. Cleared def issued from Baltimore.
SystemSubsystemCause
Deck/CargoHolds/Tanks
DescriptionDue DateResolved
46CFR153.408(e) The vessel's cargo tank high level alarm (cargo deck light) is inoperable. // Vessel class (ABS) attended and issued condition of class due to part unavailability, vessel agreed not to load cargo in US prior to repairing (vsl will unload only in next US port) - c.c. due 10 Mar 08Mar 10, 08Yes
Resolved DateResolution
Jan 10, 08Visually observed proper operation of cargo tank high-high (overfill) level alarm system, both audible and visual.
SystemSubsystemCause
Deck/CargoHolds/Tanks
DescriptionDue DateResolved
46CFR153.409(b) The vessel's cargo tank high level alarm (open deck light) is inoperable.// Vessel class (ABS) attended and issued condition of class due to part unavailability, vessel agreed not to load cargo in US prior to repairing (vsl will unload only in next US port) - c.c. due 10 Mar 08Mar 10, 08Yes
Resolved DateResolution
Jan 10, 08Visually observed proper operation of cargo tank high level alarm system, both audible and visual.
SystemSubsystemCause
Fire FightingFire Hoses
DescriptionDue DateResolved
74solas(2004 cons.) II-2/10.2.3.1.1 Two fire station are missing the hose, nozzle and deck. (forward main deck)Yes
Resolved DateResolution
Dec 10, 07
SystemSubsystemCause
CommunicationsAlarms/Indicators
DescriptionDue DateResolved
74solas(2004 cons.) II-2/4.5.7.2.2 Fixed gas detection system for the vessel's ballast tanks is inoperable.Yes
Resolved DateResolution
Dec 10, 07
SystemSubsystemCause
Fire FightingEmergency Fire Pumps
DescriptionDue DateResolved
74solas(2004cons.)II-2/10.2.2.3.1.2 Emergency fire pump inoperableYes
Resolved DateResolution
Dec 10, 07
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
MArpol73/78 Annex1/6.4.1 Vessels oil discharge monitoring equipment is inoperable. Vessel is unable to prove proper operation.Yes
Resolved DateResolution
Dec 10, 07
SystemSubsystemCause
Operations/ManagementMandatory Ship Reporting SystemsImproper/Lack of Maintenance
DescriptionDue DateResolved
On 07 December 2007, the T/S Cancale Star was found to have an inoperative emergency fire pump. The vessel did not report this condition on its notice of arrival as required by 33 CFR 160.215.Dec 13, 07Yes
Resolved DateResolution
Dec 09, 07ABS Class report 07146801 states that the fire pump motor overhauled and installed back on the vessel with no problems noted.
SystemSubsystemCause
PersonnelCertificates/Documents/Licenses
DescriptionDue DateResolved
STCW95 Reg I/10 3rd assistant engineer has flag state endorsement for regulation III/3 but should be III/1.Dec 21, 07Yes
Resolved DateResolution
Jan 10, 083rd assistant engineer disembarked vessel in last port (foreign). Verified that ship was manned in accordance with minimum safe manning certificate. Checked each of the engineering officiers licenses to ensure that they met STCW requirements.
Documents Issued Expires Agency
Classification Document November 30,2019 June 24,2022 LR
COC-TVE Renewal May 29,2021 May 29,2023 N/A
International Load Line Certificate January 15,2020 June 24,2022 LR
International Oil Pollution Prevention Certificate November 30,2019 June 24,2022 LR
ISM - Document Of Compliance November 3,2016 November 14,2021 LR
ISM - Safety Management Certificate November 12,2007 November 11,2012 N/A
Minimum Safe Manning Document November 25,2019 LR
NLS Certificate June 25,2007 June 24,2012 N/A
SOLAS Cargo Ship Safety Construction Certificate November 1,2020 June 24,2022 LR
SOLAS Cargo Ship Safety Equipment Certificate October 4,2020 June 24,2022 LR
SOLAS Cargo Ship Safety Radio Certificate June 25,2007 June 24,2012 N/A
Tonnage Certificate, International November 30,2019 LR