B. No. 282
Print Q88   
IMO/VIN Callsign Flag Service Year
1204610 WDD9822 UNITED STATES Tank Barge 2007
Activity# Port Date Activity - Description Deficiencies
6948445 STATEN ISLAND, New York May 04, 20 Vessel Inspection - Approved Inspection
6903150 PHILADELPHIA, Pennsylvania Feb 05, 20 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
09 - Working and Living Conditions092 - Working Conditions
DescriptionDue DateResolved
Each pressure vessel must be examined or tested every 5 years. The pressure vessel located in the generator room of the barge had a due date of 14 January 2020 for the inspection. No inspection has been completed. The barge crew must take the pressure vessel out of service until an internal and external inspection is completed in addition to satisfactory testing of the safety or relief valves. Testing must be completed in the presence of a USCG marine inspector.Yes
Resolved DateResolution
May 04, 20Cleared by Sec New York Inspectors.
SystemSubsystemCause
07 - Fire SafetyN/A - No Subsystem
DescriptionDue DateResolved
Portable fire extinguishers are required to be inspected and maintained IAW NFPA 10 including annual maintenance and recharging of extinguishers. The vessel's extinguishers were last serviced 30MAR19. 46 CFR 31.10-18Yes
Resolved DateResolution
Apr 22, 20Received fire servicing report.
7089592 USCG Air Station, Massachusetts Dec 10, 19 Vessel Transfer Monitor - Agency Action Complete
6830386 STATEN ISLAND, New York Oct 08, 19 Vessel Inspection - Approved Inspection
  4
SystemSubsystemCause
07 - Fire SafetyN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
The owner, master, or person-in-charge of a tank vessel must ensure that portable and semi-portable extinguishers are inspected and maintained in accordance with NFPA 10. FS-2 semi-portable extinguisher was below minimum required nitrogen PSI 46 CFR 31.10-18(a)Nov 07, 19Yes
Resolved DateResolution
Nov 08, 19Received photo of charged nitrogen tank installed on board.
SystemSubsystemCause
13 - Propulsion and Auxiliary MachineryN/A - No SubsystemInvalid
DescriptionDue DateResolved
Each generator prime mover must have an overspeed device that is independent of the normal operating governor and adjusted so that the speed cannot exceed the maximum rated speed by more than 15 percent. Send technician report showing overspeed trip and low lube oil pressure tested. 46 CFR 111.12-1(b)(c)Nov 07, 19Yes
Resolved DateResolution
Nov 07, 19Crew provided documentation of contractor performing successful shutdowns.
SystemSubsystemCause
11 - Life Saving AppliancesN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
Each life jacket must have a whistle firmly secured by a cord to the life jacket. 3 out of 4 whistles are inoperable. 46 CFR 199.70(b)Oct 22, 19Yes
Resolved DateResolution
Oct 08, 19Replaced all 4 life jackets with brand new. Inspection team verified on the spot.
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
The high level and tank overfill alarm must activate an alarm in the event of loss of power to the alarm system. Audible alarm was inoperable. 46CFR39.2007(b)(2)Nov 07, 19Yes
Resolved DateResolution
Oct 16, 19Alarm was replaced and is in working order
6552719 WASHINGTON, District of Columbia Sep 28, 18 Incident Investigation - Agency Action Complete
6554296 STATEN ISLAND, New York Sep 28, 18 Vessel Inspection - Approved Inspection
6357584 BOSTON, Massachusetts Jan 23, 18 Vessel Transfer Monitor - Agency Action Complete
6375976 WASHINGTON, District of Columbia Jan 22, 18 Incident Investigation - Agency Action Complete
6326398 STATEN ISLAND, New York Dec 19, 17 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Deck/CargoHolds/Tanks
DescriptionDue DateResolved
Flame screen on starboard aft rake vent has hole in mesh and does not meet requirement.Dec 19, 17Yes
Resolved DateResolution
Dec 19, 17The flame screen was replaced with new.
6274248 STATEN ISLAND, New York Sep 25, 17 Vessel Inspection - Agency Action Complete
6071659 ST PETERSBURG, Florida Jan 16, 17 Vessel Inspection - Approved Inspection
6071659 Tampa, Florida Jan 16, 17 Vessel Inspection - Approved Inspection
5793151 New Orleans, Louisiana Jan 08, 16 Vessel Inspection - Approved Inspection
  3
SystemSubsystemCause
ElectricalElectric Generation Source (service)Improper/Lack of Maintenance
DescriptionDue DateResolved
Hotel & No 2 generator requires new batteries replaced to satisfaction of attending marine inspector.Feb 12, 16Yes
Resolved DateResolution
Jan 13, 16Witnessed installation of new batteries and satisfactory operation of generators.
SystemSubsystemCause
ElectricalElectric Generation Source (service)Improper/Lack of Maintenance
DescriptionDue DateResolved
Provide overspeed testing documentation to satisfaction of attending CG marine inspector.Feb 12, 16Yes
Resolved DateResolution
Jan 14, 16Received documentation attesting to satisfactory overspeed testing of engines.
SystemSubsystemCause
Deck/CargoHolds/TanksImproper/Lack of Maintenance
DescriptionDue DateResolved
Vacuum side of pressure-vacuum relief valve for vapor lines not working. Repair to satisfaction of attending CG Marine Inspector prior to loading.Feb 12, 16Yes
Resolved DateResolution
Jan 13, 16Witness satisfactory operation of pressure-vacuum relief valve and testing certificate.
5215735 ST PETERSBURG, Florida Aug 14, 15 Vessel Inspection - Approved Inspection
5215735 Tampa, Florida Aug 14, 15 Vessel Inspection - Approved Inspection
5050082 ST PETERSBURG, Florida Jan 08, 15 Vessel Inspection - Approved Inspection
5050082 Tampa, Florida Jan 08, 15 Vessel Inspection - Approved Inspection
4778781 New Orleans, Louisiana Jan 17, 14 Vessel Inspection - Approved Inspection
  9
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational Safety
DescriptionDue DateResolved
Install machinery guard on belt #2 generator.Feb 21, 14Yes
Resolved DateResolution
Jan 24, 14Verified instillation of guard from pictures.
SystemSubsystemCause
EngineeringDiesel Engine (propulsion/auxiliary-electric)
DescriptionDue DateResolved
Provide 3rd party overspeed test report for generators.Feb 21, 14Yes
Resolved DateResolution
Mar 11, 14Received satisfactory third party test for generator overspeed tests.
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational Safety
DescriptionDue DateResolved
Recalibrate or repair gas sampling system in the generator room.Feb 21, 14Yes
Resolved DateResolution
Feb 11, 14Vessel has removed gas sampling system in the generator room.
SystemSubsystemCause
EngineeringDiesel Engine (propulsion/auxiliary-electric)
DescriptionDue DateResolved
Repair coolant leak on #3 generator.Feb 21, 14Yes
Resolved DateResolution
Feb 17, 14Received third party report for repairs to the #3 generators radiator.
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational Safety
DescriptionDue DateResolved
Repair machinery guard stbd ballast pump room.Feb 21, 14Yes
Resolved DateResolution
Jan 24, 14Verified instillation of guard from pictures.
SystemSubsystemCause
Deck/CargoVapor Control Systems
DescriptionDue DateResolved
Repair/install vapor control studs on the port aft and stbd fwd vapor line connections. Vessel is prohibited from using these two vapor connections until inspected by a CG MI.Yes
Resolved DateResolution
Jan 24, 14Verified instillation of vapor control studs from pictures.
SystemSubsystemCause
Operations/ManagementEquipment Service/Testing
DescriptionDue DateResolved
Replace expired hydrostatic release unit.Yes
Resolved DateResolution
Jan 17, 14Verified Hydrostatic Release was replaced from pictures sent.
SystemSubsystemCause
Deck/CargoBallast
DescriptionDue DateResolved
Replace port ballast pump safe zone seal (sleeve) prior to operating port ballast pump.Yes
Resolved DateResolution
Feb 17, 14Company has renewed safe zone seals.
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
Replace/reseal safe zone seals (sleeves) on port cargo pump room prior to discharging cargo with port cargo pump.Yes
Resolved DateResolution
Feb 17, 14Company has renewed safe zone seals.
4522659 WASHINGTON, District of Columbia Jan 22, 13 Incident Investigation - Agency Action Complete
4443634 STATEN ISLAND, New York Sep 17, 12 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
ElectricalElectric Generation Source (service)
DescriptionDue DateResolved
Vessel must demonstrate proper overspeed and lube oil shutdowns of generators. 46CFR111.12-1Dec 16, 12Yes
Resolved DateResolution
Nov 21, 12Tested correctly.
4197316 STATEN ISLAND, New York Nov 29, 11 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
DocumentationCertificates/Documents
DescriptionDue DateResolved
Vessel is restricted to Domestic Service only until IAPP survey is completed as per CG543 Policy Letter 09-01.Dec 30, 11Yes
Resolved DateResolution
Oct 16, 12Route altered on COI.
4052389 STATEN ISLAND, New York Jun 21, 11 Vessel Inspection - Approved Inspection
3928823 STATEN ISLAND, New York Jan 19, 11 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
EngineeringDiesel Engine (auxiliary)
DescriptionDue DateResolved
Demonstrate over speed and low lube oil shut down for all generators. 46CFR111.12-1Feb 02, 11Yes
Resolved DateResolution
Jun 21, 11Grace period granted until 11Nov11 where at which time overspeed and low lube oil shutdowns must be demonstrated to attending USCG marine inspector.
3865979 STATEN ISLAND, New York Oct 08, 10 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
During ISE Marine Inspector found side shell to be buckled in 5 port bay #4 counting from aft. C/RNov 11, 10Yes
Resolved DateResolution
Nov 08, 10Received report from ABS , above mentioned was repaired and considered Satisfactory.
3684859 NEW HAVEN, Connecticut Feb 23, 10 Vessel Transfer Monitor - Agency Action Complete
3654116 STATEN ISLAND, New York Dec 22, 09 Vessel Inspection - Agency Action Complete
3605604 STATEN ISLAND, New York Sep 30, 09 Vessel Inspection - Approved Inspection
3602227 NEW HAVEN, Connecticut Sep 24, 09 Vessel Transfer Monitor - Agency Action Complete
3337740 STATEN ISLAND, New York Oct 03, 08 Vessel Inspection - Agency Action Complete
3122887 New Orleans, Louisiana Dec 31, 07 Vessel Inspection - Approved Inspection
3077641 New Orleans, Louisiana Oct 11, 07 Vessel Inspection - Approved Inspection
Documents Issued Expires Agency
Cargo Authority Attachment December 28,2007 N/A
CERTIFICATE OF DOCUMENTATION May 19,2021 May 31,2022 USCG
Certificate of Inspection October 25,2007 October 25,2012 N/A
Certificate of Inspection - Amended October 25,2007 October 25,2012 N/A
Classification Document September 22,2012 September 22,2017 N/A
International Load Line Certificate September 22,2012 October 24,2017 N/A