Activity# Port Date Activity - Description Deficiencies
7411704 Houston, Texas Mar 14, 22 Vessel Inspection - Approved Inspection
7078884 New Orleans, Louisiana Oct 17, 20 Vessel Operational Control - Administrative Action
7078940 WASHINGTON, District of Columbia Oct 17, 20 Incident Investigation - Agency Action Complete
7074860 Houston, Texas Oct 10, 20 Vessel Inspection - Approved Inspection
6971271 STATEN ISLAND, New York Jun 08, 20 Vessel Inspection - Approved Inspection
6270059 Lewes, Delaware Sep 19, 17 Vessel Inspection - Approved Inspection
6254357 Lewes, Delaware Sep 06, 17 Vessel Inspection - Approved Inspection
  7
SystemSubsystemCause
Fire FightingFixed Gas Fire Extinguishing SystemImproper/Lack of Maintenance
DescriptionDue DateResolved
0725 Machinery spaces of cat A containing oil fuel units shall be provided w/one of the fixed-fire extinguishing systems in Paragraph 4.1.During exam of fixed gas fire-extinguishing system for purifier room,PSCOs found connections on flex lines from CO2 bottles to the distribution manifold disconnected, and svc valve for Purifier Room in OPEN pos. SOLASII-2/10.5.1.1 30 60 abYes
Resolved DateResolution
Sep 08, 17Received class report attesting to proper connections were made and signs posted to ensure service port for CO2 was closed.
SystemSubsystemCause
Fire FightingFixed Pressure Water-Spraying Fire Extinguishing SystemImproper/Lack of Maintenance
DescriptionDue DateResolved
0725- Fire protection system and fire fighting system and appliances shall be maintained and ready for use. PSCO observed both supply lines for water mist system closed preventing system to operate as designed. SOLASII-2/14.1.1 30,60abYes
Resolved DateResolution
Sep 08, 17Received class surveyor's report attesting to proper alignment of the vessel's water mist system. Additionally, vessel posted signs to ensure the valve for the water supply to the is open.
SystemSubsystemCause
NavigationPiloting/SteeringDamaged By Earlier Event
DescriptionDue DateResolved
1510-An ECDIS to plan and display ships route for intended voyage and back-up arrangement shall be equipped. Secondary ECDIS is not operational. SOLASV19.2.1.4.5 17abYes
Resolved DateResolution
Sep 08, 17Received tech report attesting to proper operation of the vessel's ECDIS.
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)Improper Installation
DescriptionDue DateResolved
1820- Cargo pump room shall be mechanically ventilated 20 air changes/hour. PSCO observed insufficient ventilation in cargo pump room. Stbd fan was working in reverse, causing a short circuit in air flow and not providing exchange of air in pump room. Complete prior to cargo ops. SOALSII-2/4.5.4.1 17abYes
Resolved DateResolution
Sep 08, 17Received class report stating that the ventilation for the pump room is now functioning properly.
SystemSubsystemCause
Deck/CargoHolds/TanksDamaged By Earlier Event
DescriptionDue DateResolved
1840-Gas detection equipment shall be designed to sample line of each space protected, sequentially at intervals not to exceed 30 min. PSCO's observed multiple errors for spaces protected. Also, cabinet was found open, preventing cabinet from producing proper sample. SOLASII-2/14.5.7.3.1 FSS16.2.2.3.1 17ab (Vessel restricted from loading cargo in US waters).Yes
Resolved DateResolution
Sep 19, 17Manufactures Technician attended vessel renewed o rings and solenoid valves and cleaned manifold. System was restored to operation, additional training was provided to crew.
SystemSubsystemCause
Operations/ManagementEPA Vessel General Permit (VGP)Improper/Lack of Maintenance
DescriptionDue DateResolved
9900- Advised master to submit NOI as per Vessel General Permit VGP1.5.1.1 Part 10 App E.Yes
Resolved DateResolution
Sep 08, 17NOI submitted.
SystemSubsystemCause
DocumentationSafety Management System
DescriptionDue DateResolved
The COTP questions the adequacy of the implementation of the vessels safety management system under the ISM code. An External audit is recommended to be conducted within 30 days by the Flag State or the RSO. If audit will take place, please notify MSD Lewes of the decision to conduct External Audit. SOLASIX/3.1 17abOct 06, 17Yes
Resolved DateResolution
Sep 28, 17ISM Audit was conducted with no deficiencies noted on summary.
5947181 Morgan City, Louisiana Jul 24, 16 Vessel Inspection - Approved Inspection
5950309 New Orleans, Louisiana Jul 23, 16 Vessel Operational Control - Agency Action Complete
5786314 New Orleans, Louisiana Dec 23, 15 Vessel Inspection - Administrative Action
5161174 New Orleans, Louisiana Jun 28, 15 Vessel Inspection - Approved Inspection
5162202 New Orleans, Louisiana Jun 24, 15 Vessel Operational Control - Agency Action Complete
Documents Issued Expires Agency
Classification Document January 20,2015 January 19,2020 LR
COC-TVE Annual June 28,2015 June 28,2017 MORMS
COC-TVE Renewal September 6,2017 September 6,2019 N/A
International Load Line Certificate April 5,2020 January 19,2025 ABS
International Oil Pollution Prevention Certificate April 5,2020 January 19,2025 ABS
ISM - Document Of Compliance January 12,2018 January 15,2023 BV
ISM - Safety Management Certificate April 17,2020 June 29,2025 BV
Minimum Safe Manning Document February 3,2015 January 2,2020 MT
SOLAS Cargo Ship Safety Construction Certificate April 5,2020 January 19,2025 ABS
SOLAS Cargo Ship Safety Equipment Certificate April 5,2020 January 19,2025 ABS
SOLAS Cargo Ship Safety Radio Certificate January 20,2015 January 19,2020 LR
Tonnage Certificate, International July 4,2015 LR