Beks Iron
Print Q88   
IMO/VIN Callsign Flag Service Year
9306562 SYQM GREECE Tank Ship 2005
Activity# Port Date Activity - Description Deficiencies
7644402 CORPUS CHRISTI, Texas Mar 02, 23 Vessel Inspection - Approved Inspection
7594382 Houston, Texas Dec 04, 22 Vessel Inspection - Approved Inspection
7594004 Houston, Texas Nov 14, 22 Vessel Inspection - Agency Action Complete
7128612 New Orleans, Louisiana Jan 22, 21 Vessel Inspection - Administrative Action
7113220 PHILADELPHIA, Pennsylvania Dec 21, 20 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
11 - Life Saving AppliancesN/A - No Subsystem
DescriptionDue DateResolved
IF A SHIP HAS ANY WATCH OR WORK STATIONS WHICH ARE LOCATED REMOTELY FROM THE PLACE OR PLACES WEHRE IMMERSION SUITS ARE NORMALLY STOWED.... ADDITIONAL IMMERSION SUITS OF AN APPROPRIATE SIZE SHALL BE PROVIDED AT THESE LOCATIONS FOR THE NUMBER OF PERSOS NORMALLY ON WATCH OR WORKING AT THESE LOCATION AT ANY TIME. THE ENGINE CONTROL ROOM HAS 04 LIFE JACKETS BUT NO IMMERSION SUITS, THIS IS IAW THE LIFESAVING/FIRE CONTROL PLAN BUT SHOULD BE AMENDED TO INCLUDE THE REQURIED NUMBER OF IMMERSION SUITS AT THIS REMOTE WATCH STATION. 74 SOLAS (2014) III Regulation 32.3.3Yes
Resolved DateResolution
Jan 21, 21
SystemSubsystemCause
10 - Safety of NavigationN/A - No Subsystem
DescriptionDue DateResolved
PILOT LADDER WAS RIGGED WITH SHACKLES HOLDING LADDER AT THE STEP, WHICH IS NOT A POINT AS STRONG AS THE SIDE ROPES. THIS IS NOT A COMPLIANT ARRANGEMENT AS PER SOLAS V/23 AND RESOLUTION A 1045(27). REGULATION 23 & IMO RES. A 1045(27)Yes
Resolved DateResolution
Jan 21, 21
6849003 CORPUS CHRISTI, Texas Nov 14, 19 Vessel Inspection - Approved Inspection
6705910 San Francisco, California Jun 06, 19 Vessel Operational Control - Agency Action Complete
6568311 Port Arthur, Texas Nov 07, 18 Vessel Inspection - Approved Inspection
6517634 PHILADELPHIA, Pennsylvania Aug 20, 18 Vessel Inspection - Approved Inspection
6291593 New Orleans, Louisiana Oct 25, 17 Vessel Inspection - Approved Inspection
6142394 San Francisco, California May 09, 17 Boarding - Agency Action Complete
6018729 New Orleans, Louisiana Oct 16, 16 Vessel Inspection - Approved Inspection
5957524 San Francisco, California Jul 30, 16 Vessel Inspection - Approved Inspection
5837386 CORPUS CHRISTI, Texas Mar 21, 16 Vessel Inspection - Approved Inspection
5793694 Houston, Texas Jan 08, 16 Vessel Inspection - Agency Action Complete
5743216 Houston, Texas Oct 15, 15 Vessel Inspection - Approved Inspection
5228619 Mobile, Alabama Aug 28, 15 Vessel Inspection - Approved Inspection
5225802 Mobile, Alabama Aug 28, 15 Vessel Inspection - Approved Inspection
5059047 Cape Canaveral, Florida Jan 26, 15 Vessel Inspection - Approved Inspection
5025655 STATEN ISLAND, New York Nov 18, 14 Vessel Inspection - Approved Inspection
4736196 CORPUS CHRISTI, Texas Oct 17, 13 Vessel Inspection - Approved Inspection
4726666 Houston, Texas Oct 02, 13 Vessel Inspection - Approved Inspection
4565874 San Pedro, California Apr 09, 13 Vessel Inspection - Approved Inspection
4565826 San Diego, California Apr 09, 13 Vessel Inspection - Approved Inspection
4449110 Port Arthur, Texas Sep 26, 12 Boarding - Agency Action Complete
4448865 Port Arthur, Texas Sep 26, 12 Vessel Inspection - Approved Inspection
4153660 San Pedro, California Oct 02, 11 Vessel Inspection - Agency Action Complete
4018500 Port Arthur, Texas May 22, 11 Boarding - Agency Action Complete
3864585 STATEN ISLAND, New York Oct 06, 10 Vessel Inspection - Approved Inspection
3795831 PHILADELPHIA, Pennsylvania Jul 14, 10 Vessel Inspection - Approved Inspection
3705126 PHILADELPHIA, Pennsylvania Mar 29, 10 Vessel Inspection - Approved Inspection
3670833 Houston, Texas Jan 27, 10 Vessel Operational Control - Approved Inspection
  1
SystemSubsystemCause
Operations/ManagementNavigation Safety
DescriptionDue DateResolved
Letter of Deviation granted for inoperable rudder angle indicator. 33CFr 164.35 fFeb 05, 10Yes
Resolved DateResolution
Jan 29, 10On 29JAN2010, Technical Report was submitted attesting vessel''''s rudder angle indicator was working normal, OPCON released.
3595130 PHILADELPHIA, Pennsylvania Sep 15, 09 Vessel Inspection - Approved Inspection
3466187 New Orleans, Louisiana May 03, 09 Vessel Inspection - Administrative Action
3395418 Portsmouth, Virginia Jan 16, 09 Vessel Inspection - Approved Inspection
3310570 Lewes, Delaware Aug 29, 08 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
DocumentationCertificates/DocumentsUnknown
DescriptionDue DateResolved
0199 -- Certificates documents other -- SOLAS Certificates are required to be on board at all times. The original solas safety equipment certificate had been removed by the vessel's agent. SOLAS 2004 Chapter I Reg 16.Yes
Resolved DateResolution
Dec 22, 08documents returned to vessel.
SystemSubsystemCause
Construction/LoadlineMarkingsImproper Installation
DescriptionDue DateResolved
1299 -- Load line other -- Initials of the marking authority are required to be permanently assigned on vessel, however the marks were simply painted upon the hull. ICLL 1966 Chapter I Reg 8.Yes
Resolved DateResolution
Jan 16, 09The vessel is not required to have the initials of the marking authority on the load line.
3147694 Port Arthur, Texas Feb 14, 08 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
NavigationCollision/Grounding AvoidanceUnknown
DescriptionDue DateResolved
Radar was found loose and in hanging position and held by 1 of 4 bolts. Need to reinstall motor and scanner as per manufacturer's specifications.Yes
Resolved DateResolution
Feb 16, 08Recieved technichian''s report attasting to repairs made to the radar motor and antenna.
3125565 New Orleans, Louisiana Jan 12, 08 Vessel Inspection - Approved Inspection
3059659 Houston, Texas Sep 17, 07 Vessel Inspection - Agency Action Complete
3037525 New Orleans, Louisiana Aug 30, 07 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Deck/CargoHolds/Tanks
DescriptionDue DateResolved
While conducting the cargo portion of the COC exam the PSCO could not test and verify the proper operation of the High (95%) level alarms. Vessel is prohibited from loading any cargos that require High level alarms and from using their Vapor Control System in U.S. waters.Aug 30, 07Yes
Resolved DateResolution
Sep 01, 07PSC NOLA received proper documentation from Rosemont Tank Gauging attesting to the satisfactory repairs of the vessel''s high level alarms.
2990677 Savannah, Georgia Jul 10, 07 Vessel Transfer Monitor - Approved Inspection
2985928 Jacksonville, Florida Jul 06, 07 Vessel Operational Control - Agency Action Complete
2849112 Jacksonville, Florida Jan 02, 07 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Operations/ManagementBallast Water ManagmentImproper/Lack of Maintenance
DescriptionDue DateResolved
Vessel failed to file Ballast Water Report at least 24 hours prior to arrival. To the satisfaction of USCG.Yes
Resolved DateResolution
Jan 12, 07MSU Wilmington confirmed submission of BWM report on 4Jan2007.
2849888 ATLANTIC BEACH, Florida Jan 02, 07 Boarding - Agency Action Complete
2857397 Savannah, Georgia Dec 29, 06 Vessel Operational Control - Agency Action Complete
2847682 Jacksonville, Florida Dec 29, 06 Vessel Operational Control - Agency Action Complete
2792650 New Orleans, Louisiana Oct 03, 06 Vessel Inspection - Approved Inspection
2753476 STATEN ISLAND, New York Aug 20, 06 Vessel Inspection - Approved Inspection
2651048 Houston, Texas May 17, 06 Boarding - Approved Inspection
2597502 San Pedro, California Mar 07, 06 Vessel Operational Control - Agency Action Complete
2556400 CORPUS CHRISTI, Texas Dec 26, 05 Vessel Inspection - Agency Action Complete
2551834 Christiansted, Virgin Islands Dec 15, 05 Vessel Inspection - Approved Inspection
2520189 New Orleans, Louisiana Oct 23, 05 Vessel Inspection - Approved Inspection
2495885 Miami Beach, Florida Sep 19, 05 Vessel Operational Control - Agency Action Complete
2491578 Port Arthur, Texas Aug 19, 05 Vessel Operational Control - Agency Action Complete
2467914 Port Arthur, Texas Aug 19, 05 Vessel Inspection - Approved Inspection
2459145 CORPUS CHRISTI, Texas Aug 15, 05 Vessel Inspection - Agency Action Complete
  2
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
OWS not installed IAW approved OWS plans. Class to attend prior to next US port. Rec'd class rpt dated 16Aug05 stating the crossover valve was removed and flanges blanked off. Vsl is to provide a copy of the drawing that shows the crossover on an ABS approved drawing.Yes
Resolved DateResolution
Oct 23, 05Received class report from ABS satisfying requirement.
SystemSubsystemCause
Deck/CargoHolds/Tanks
DescriptionDue DateResolved
Tank overfill alarm not operable. Repair to satisfaction of class prior to loading cargo. Rec'd class rpt dated 16Aug05 limiting vsl to 95% loading of cargo tanks and tank level alarm to be operational at the next US port.Aug 31, 05Yes
Resolved DateResolution
Oct 23, 05Received class report from ABS satisfying requirement.
2454971 CORPUS CHRISTI, Texas Aug 14, 05 Boarding - Agency Action Complete
Documents Issued Expires Agency
Classification Document September 7,2005 June 9,2010 ABS
COC-TVE Annual October 20,2010 October 6,2012 N/A
COC-TVE Renewal September 18,2009 September 18,2011 N/A
International Load Line Certificate August 13,2020 June 4,2025 GR
International Oil Pollution Prevention Certificate May 17,2015 June 4,2020 LR
ISM - Document Of Compliance October 25,2019 November 4,2024 LR
ISM - Safety Management Certificate November 15,2005 November 14,2010 ABS
Minimum Safe Manning Document June 16,2017 GR
SOLAS Cargo Ship Safety Construction Certificate September 16,2020 June 4,2025 GR
SOLAS Cargo Ship Safety Equipment Certificate August 13,2020 June 4,2025 GR
SOLAS Cargo Ship Safety Radio Certificate May 17,2015 June 4,2020 N/A
Tonnage Certificate, International October 11,2007 GR