Royal Peridot
Print Q88   
IMO/VIN Callsign Flag Service Year
9367449 V7OW2 MARSHALL ISLANDS Tank Ship 2007
Activity# Port Date Activity - Description Deficiencies
3399151 New Orleans, Louisiana Jan 24, 09 Vessel Operational Control - Agency Action Complete
3399150 New Orleans, Louisiana Jan 23, 09 Vessel Inspection - Administrative Action
3384494 San Francisco, California Dec 28, 08 Vessel Inspection - Approved Inspection
  6
SystemSubsystemCause
Operations/ManagementBallast Water Managment
DescriptionDue DateResolved
0199- Other Certs- Ballast water management plan provided by the company does not provide guidance or forms for sediment management or removal. Crew familiarization and training is not being performed or recorded for ballast exchange. Company provided handling log does not match form provided in the plan. Total number of tanks and volume listed on reports do not match the plan. (70 a/b)Dec 28, 08Yes
Resolved DateResolution
Jan 23, 09Received class report from ABS satisfying requirement.
SystemSubsystemCause
Fire FightingStructural - A Class Divisions
DescriptionDue DateResolved
0750- Fire Prevention- Numerous self closing fire doors throughout the ship have hold back devices installed. In addition self closing door between galley and officers mess does not close completely. (70 a/b)Dec 28, 08Yes
Resolved DateResolution
Jan 23, 09Received class report from ABS satisfying requirement.
SystemSubsystemCause
Deck/CargoVapor Control Systems
DescriptionDue DateResolved
1150- Loadings and Unloading Equipment- Vapor connection pins are missing from three of the four flange connections at port and starboard manifolds. 2 port side/1 starboard aft. (70 a/b) ISGOT 11.1.132Dec 28, 08Yes
Resolved DateResolution
Jan 23, 09Received class report from ABS satisfying requirement.
SystemSubsystemCause
EngineeringDiesel Engine (propulsion-direct drive)
DescriptionDue DateResolved
1410- Propulsion Main Engine- Main engine intercooler condensation drain has been modified by adding a flange and flexible hose leading to the aft bilge well tank. Class is to determine if modification is appropriate. (70 a/b) 70a/bDec 28, 08Yes
Resolved DateResolution
Jan 23, 09Received class report from ABS satisfying requirement.
SystemSubsystemCause
DocumentationManuals/Policy Documentation
DescriptionDue DateResolved
2045-Cargo Operartion- Cargo transfer procedures created for transfer in Richmond do not meet requirements of the regulations. (10) Dec 28, 08Yes
Resolved DateResolution
Dec 28, 08Template provided to the captain.
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
Marine sanitation device is not being maintained in accordance with the manufactures operating procedures. Chlorine tablets are the incorrect size for tube and test kit for weekly testing has not been provided by the company. (70 a/b) 33 CFR 159.121(b) 70 a/bDec 28, 08Yes
Resolved DateResolution
Jan 23, 09Received class report from ABS satisfying requirement.
Documents Issued Expires Agency
Certificate of Fitness - Chemical Carrier April 25,2008 June 14,2012 ABS
Classification Document April 24,2008 June 14,2012 ABS
International Load Line Certificate October 14,2008 June 14,2012 ABS
International Oil Pollution Prevention Certificate June 27,2008 June 14,2012 ABS
ISM - Document Of Compliance August 5,2008 March 15,2009 ABS
ISM - Safety Management Certificate September 6,2008 September 25,2013 KR
Minimum Safe Manning Document March 28,2008 MH
SOLAS Cargo Ship Safety Construction Certificate April 25,2008 June 14,2012 ABS
SOLAS Cargo Ship Safety Equipment Certificate April 25,2008 June 14,2012 ABS
SOLAS Cargo Ship Safety Radio Certificate April 25,2008 June 14,2012 ABS
Tonnage Certificate, International June 27,2008 ABS