B. No. 262
Print Q88   
IMO/VIN Callsign Flag Service Year
1216336 WDE7230 UNITED STATES Tank Barge 2009
Activity# Port Date Activity - Description Deficiencies
7116360 STATEN ISLAND, New York Dec 26, 20 Vessel Inspection - Approved Inspection
  1   1
SystemSubsystemCause
02 - Structural ConditionsN/A - No Subsystem
DescriptionDue DateResolved
BARGE EXPERIENCED IMPACT FROM A TUG THAT BROKE FREE FROM ITS MOORING. THE IMPACT WAS IN THE FORWARD RAKE ON THE STARBOARD SIDE IN THE VICINITY OF THE BILGE KNUCKLE, APPROXIMATELY 3-FEET FROM THE WATERLINE. SPACE TO BE GAS FREED AND CERTIFIED BY A MARINE CHEMIST PRIOR TO C.G. MARINE INSPECTOR ENTRY FOR A DAMAGE SURVEY. 46 CFR 35.01-1; 46 CFR 31.01-1Yes
Resolved DateResolution
Dec 29, 20Recieved Marine Chemist certificate ceritifying space safe for entry.
SystemSubsystemCause
02 - Structural ConditionsN/A - No SubsystemDamaged By Earlier Event
DescriptionDue DateResolved
If during an internal structural examination damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the Officer in Charge, Marine Inspection, may require the vessel to be drydocked or otherwise taken out of service to further assess the extent of the damage and to effect permanent repairs. Structural damage located on the stbd bow/fwd rake must be repaired at next scheduled dry dock or as required by the OCMI, anytime the vessel is no longer fit for intended service. Insets located on the bilge knuckle at the fwd bottom plate and side shell plate require C/R. Logitudinal stiffener in the vicinity of damage has an approximate 04 cracked weld and will require to be V/W at next dry dock.Dec 29, 20No
7105100 STATEN ISLAND, New York Dec 02, 20 Vessel Inspection - Agency Action Complete
7026688 STATEN ISLAND, New York Aug 07, 20 Vessel Inspection - Approved Inspection
6669940 STATEN ISLAND, New York Apr 25, 19 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
11 - Life Saving AppliancesN/A - No SubsystemImproper Installation
DescriptionDue DateResolved
Vessel carried an inadequate number of life buoys with self-igniting lights. Acquire the adequate amount and provide evidence of installation.Apr 29, 19Yes
Resolved DateResolution
May 09, 19
SystemSubsystemCause
11 - Life Saving AppliancesN/A - No SubsystemImproper Installation
DescriptionDue DateResolved
Vessel carried an inadequate number of lifebuoys.Apr 29, 19Yes
Resolved DateResolution
May 09, 19
6651280 STATEN ISLAND, New York Mar 28, 19 Vessel Inspection - Approved Inspection
6343368 STATEN ISLAND, New York Jan 25, 18 Vessel Inspection - Approved Inspection
6333123 STATEN ISLAND, New York Jan 05, 18 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Operations/ManagementDrills/Instruction
DescriptionDue DateResolved
Abandon ship drills and fire fighting drills were not properly logged.Jan 05, 18Yes
Resolved DateResolution
Jan 05, 18Crew was trained to document as seperate drills and individual items on the log and vessel drill record.
SystemSubsystemCause
Construction/LoadlinePenetrations
DescriptionDue DateResolved
Gaskets on hatches for starboard void were either missing or non-continuous.Jan 15, 18Yes
Resolved DateResolution
Jan 17, 18Received pictures of replaced gaskets.
6132030 STATEN ISLAND, New York Apr 28, 17 Vessel Inspection - Approved Inspection
5910298 Portsmouth, Virginia Jun 20, 16 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)Improper/Lack of Maintenance
DescriptionDue DateResolved
Vessel had no proof of annual pressure gauge testing for gargo pipping. Provide proof of annual cargo pipping gauge testing. Cite: 49CFR40Jul 04, 16Yes
Resolved DateResolution
Jun 20, 16Provided document proving that gauges were tested along with pipping.
SystemSubsystemCause
DocumentationCertificates/Documents
DescriptionDue DateResolved
Vessel had no proof of which personnel were enrolled in drug consortium. Provide proof of crewmember enrollment in drug testing program. Cite: 49CFR40Jul 04, 16Yes
Resolved DateResolution
Jun 21, 16
5222348 STATEN ISLAND, New York Aug 21, 15 Vessel Inspection - Agency Action Complete
5169928 STATEN ISLAND, New York Jul 01, 15 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
ElectricalElectrical Distribution System (service)
DescriptionDue DateResolved
Barge's 240v ground detection system was inoperable at time of inspection.Jul 09, 15Yes
Resolved DateResolution
Jul 09, 15Received tech report from vessel stating new ground detection system has been installed and tested to work.
5147979 STATEN ISLAND, New York Jun 08, 15 Vessel Inspection - Approved Inspection
5095873 WASHINGTON, District of Columbia Apr 02, 15 Incident Investigation - Agency Action Complete
5064818 WASHINGTON, District of Columbia Feb 05, 15 Incident Investigation - Agency Action Complete
4827518 STATEN ISLAND, New York Apr 02, 14 Vessel Inspection - Agency Action Complete
4625121 STATEN ISLAND, New York Jun 20, 13 Vessel Inspection - Agency Action Complete
  2
SystemSubsystemCause
ElectricalElectrical Distribution System (service)
DescriptionDue DateResolved
Investigate and provide electrician's report on faults in 240V and 120V ground detection systems. 46 CFR 111.05-21Jul 19, 13Yes
Resolved DateResolution
Jul 08, 13Electrician replaced damaged bulbs and renewed damaged high temp wiring in forward mast floodlight. All ground detection systems tested with no faults.
SystemSubsystemCause
ElectricalElectrical Distribution System (service)
DescriptionDue DateResolved
Properly terminate exposed wiring to battery bank between #1 and #2 generators. 46 CFR 111.60Jul 19, 13Yes
Resolved DateResolution
Jul 08, 13Electrician properly terminated spare wiring inside battery box.
4495199 STATEN ISLAND, New York Dec 03, 12 Vessel Inspection - Agency Action Complete
4359304 STATEN ISLAND, New York Jun 28, 12 Vessel Inspection - Agency Action Complete
  6
SystemSubsystemCause
DocumentationCertificates/Documents
DescriptionDue DateResolved
Vessel must correct bunker reciepts and bunker notes to correctly correspond with each other. Prior to sailing foreign.Yes
Resolved DateResolution
Jun 20, 13Reviewed vessel records for bunker notes/receipts. Vessel has implemented new company procedure for tracking bunker activities and now records information on consolidated spreadsheet.
SystemSubsystemCause
ElectricalElectric Generation Source (service)
DescriptionDue DateResolved
Vessel must demonstrate overspeed and low lube oil shutdowns on generators. 46CFR111.12Jul 13, 12Yes
Resolved DateResolution
Jul 13, 12Rcvd proof of testing by generator tech.
SystemSubsystemCause
Operations/ManagementCargo Transfer/Lightering
DescriptionDue DateResolved
Vessel must mark vapor line in accordance with 49CFR39.20-1Jul 05, 12Yes
Resolved DateResolution
Jul 05, 12Rcvd proof of correct marking.
SystemSubsystemCause
DocumentationCertificates/Documents
DescriptionDue DateResolved
Vessel must obtain EIAPP documents before issuance of IAPP. Prior to sailing foreign.Yes
Resolved DateResolution
Jun 25, 13Vessel provided EIAPP documentation for cargo pump engines. IAPP certificate drafted for issuance.
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational Safety
DescriptionDue DateResolved
Vessel must obtain functioning gas detection equipment. 46CFR35.30-15Jul 13, 12Yes
Resolved DateResolution
Jul 13, 12Rcvd report, vssl has new gas meter.
SystemSubsystemCause
LifesavingLine-Throwing Appliances
DescriptionDue DateResolved
Vessel must obtain valid (not expired) line throwing appliance. [Flares should be checked at this time as well] 46CFR199.170Jul 05, 12Yes
Resolved DateResolution
Jul 05, 12Rcvd proof or vssl rcving new LTA.
4276853 STATEN ISLAND, New York Apr 02, 12 Vessel Inspection - Agency Action Complete
4052303 STATEN ISLAND, New York Jun 21, 11 Vessel Inspection - Approved Inspection
4014996 STATEN ISLAND, New York May 18, 11 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Operations/ManagementPollution
DescriptionDue DateResolved
Provide proof of bunker notes with percent of sulfur and properly mark sample bottles IAW Marpol Annex VI.May 25, 11Yes
Resolved DateResolution
May 19, 11
3963914 WASHINGTON, District of Columbia Mar 14, 11 Incident Investigation - Agency Action Complete
3941227 STATEN ISLAND, New York Feb 08, 11 Vessel Inspection - Failure to Show
3917420 STATEN ISLAND, New York Dec 29, 10 Vessel Inspection - Agency Action Complete
3860991 Woods Hole, Massachusetts Sep 30, 10 Facility Transfer Monitor - Approved Inspection
3669279 STATEN ISLAND, New York Jan 25, 10 Vessel Inspection - Agency Action Complete
3653481 STATEN ISLAND, New York Dec 21, 09 Vessel Inspection - Agency Action Complete
3472517 NEW HAVEN, Connecticut May 11, 09 Vessel Transfer Monitor - Agency Action Complete
3439786 Morgan City, Louisiana Oct 15, 08 Vessel Inspection - Approved Inspection
Documents Issued Expires Agency
Cargo Authority Attachment February 4,2009 N/A
CERTIFICATE OF DOCUMENTATION August 29,2020 September 30,2021 USCG
Certificate of Inspection March 31,2014 March 31,2019 N/A
Certificate of Inspection - Amended March 31,2009 March 31,2014 N/A
Classification Document April 8,2014 March 30,2019 ABS
International Load Line Certificate March 31,2009 March 31,2014 N/A
International Oil Pollution Prevention Certificate March 31,2009 March 31,2014 USCG
Int'l Oil Poll Prevention, Form B Supplement April 25,2019 April 25,2023 SECNY
NLS Certificate August 4,2010 March 31,2014 N/A
Tonnage Certificate, International March 26,2009 N/A