Gm 11105
Print Q88   
IMO/VIN Callsign Flag Service Year
1175715 KETU UNITED STATES Tank Barge 2005
Activity# Port Date Activity - Description Deficiencies
7112243 STATEN ISLAND, New York Dec 15, 20 Vessel Inspection - Agency Action Complete
7081793 Morgan City, Louisiana Oct 21, 20 Vessel Inspection - Approved Inspection
7067010 Morgan City, Louisiana Sep 28, 20 Vessel Inspection - Approved Inspection
6957032 WASHINGTON, District of Columbia May 20, 20 Incident Investigation - Agency Action Complete
6896653 STATEN ISLAND, New York Jan 23, 20 Facility Transfer Monitor - Agency Action Complete
6853576 STATEN ISLAND, New York Nov 12, 19 Vessel Inspection - Agency Action Complete
  2
SystemSubsystemCause
09 - Working and Living Conditions092 - Working Conditions
DescriptionDue DateResolved
If the voltage of a distribution system is less than 1,000 volts, a tank vessel must not have a grounded distribution system. MIs identified single pole breakers which indicates a grounded system. Provide an explanation as to why the tank vessel has a grounded distribution system. 46 CFR 111.05-19(a)Nov 26, 19Yes
Resolved DateResolution
Nov 26, 19
SystemSubsystemCause
14 - Pollution Prevention146 - MARPOL Annex VI
DescriptionDue DateResolved
The bunker delivery note shall be accompanied by a sample of the fuel oil delivered IAW the guidelines of MPEC.182(59). Vessel did not have an approved method to properly obtain fuel samples. MARPOL 73/78(2011 cons) Annex VI / Reg 18.8.1 MPEC.182(59)4.1Dec 10, 19Yes
Resolved DateResolution
Jan 16, 20Received photographic evidence of new continuous fuel sampling valve.
6559104 STATEN ISLAND, New York Oct 11, 18 Vessel Inspection - Approved Inspection
6327899 WASHINGTON, District of Columbia Dec 17, 17 Incident Investigation - Agency Action Complete
6307864 STATEN ISLAND, New York Nov 16, 17 Vessel Inspection - Approved Inspection
6040411 WASHINGTON, District of Columbia Nov 13, 16 Incident Investigation - Agency Action Complete
6024532 STATEN ISLAND, New York Oct 18, 16 Vessel Inspection - Approved Inspection
5961216 BOSTON, Massachusetts Aug 02, 16 Vessel Transfer Monitor - Approved Inspection
5751586 STATEN ISLAND, New York Oct 27, 15 Vessel Inspection - Approved Inspection
5717659 STATEN ISLAND, New York Sep 14, 15 Vessel Inspection - Approved Inspection
5138752 STATEN ISLAND, New York May 29, 15 Vessel Inspection - Agency Action Complete
5037217 STATEN ISLAND, New York Dec 10, 14 Vessel Inspection - Agency Action Complete
4977901 WASHINGTON, District of Columbia Sep 07, 14 Incident Investigation - Agency Action Complete
4836581 STATEN ISLAND, New York Apr 15, 14 Vessel Inspection - Agency Action Complete
4739801 Houston, Texas Oct 23, 13 Vessel Inspection - Approved Inspection
4730154 STATEN ISLAND, New York Oct 07, 13 Vessel Inspection - Agency Action Complete
  8
SystemSubsystemCause
LifesavingLifejacket/PFD (General)
DescriptionDue DateResolved
Each lifejacket must have a light approved under approval series 161.112 securely attached to the front shoulder area. Vessel must replace all expired lifejacket lights. 46 CFR 199.70(b)(4)Nov 05, 13Yes
Resolved DateResolution
Oct 31, 13Received purchase order for 6 ACR auto hemi lights, delivered by Sea Safety International INC.
SystemSubsystemCause
LifesavingInflatable Liferafts
DescriptionDue DateResolved
Inflatable life rafts must be arranged for float free launching. 46 CFR 199.130(c)(7)Nov 05, 13Yes
Resolved DateResolution
Oct 31, 13Vessel provided photo documentation of proper mounting of hydrostatic release units for Port/Stbd inflatable liferafts.
SystemSubsystemCause
EngineeringFuel Oil Service System
DescriptionDue DateResolved
Nonmetallic flexible hose may be used in fuel oil systems in lengths not exceeding 30 inches. Fuel oil systems on all 3 generator prime movers exceed the 30 inch maximum. Vsl must install fixed piping to reduce flex hose length below the maximum. Flex hose must be SAE J1942 compliant. 46 CFR 56.60-25(b)(4) (25NOV13) Extended due date from 29NOV to 29DEC. Extended due date from 28FEB to 14MAR14.Mar 14, 14Yes
Resolved DateResolution
Apr 15, 14Vessel installed double wall fuel line on three Caterpillar Diesel Generators which intern shorten the non-metallic flexible fuel line and lube oil line to below the 30" maximum allowance. Repairs are satisfactory,
SystemSubsystemCause
DocumentationLogs/Records
DescriptionDue DateResolved
NOx Technical Files are not up-to-date. Vsl must review engine history of all 3 generator prime movers and make chronological entries in the record book of engine parameters for each. MARPOL Annex VI Reg. 5.3.2 / NOx Technical Code Reg . 6.2.2.8 (25NOV13) Extended due date from 29NOV to 13DEC. Extended due date from 13DEC to 29DEC.Dec 29, 13Yes
Resolved DateResolution
Dec 31, 13Reviewed updated Records of Changes for each engine on IAPP. Updates satisfactory and vsl rep understands the standard which must be maintained.
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
Provided documentation that all cargo pump discharge pressure gauges have been calibrated. 33 CFR 156.170(c)(3) (12NOV13) Extended due date from 12NOV to 29NOV per company request. (25NOV13) Extended due date from 29NOV to 13DEC.Dec 13, 13Yes
Resolved DateResolution
Dec 04, 13Vessel provided documentation showing pressure gauges had been tested/calibrated on 03DEC2013.
SystemSubsystemCause
ElectricalElectrical Distribution System (service)
DescriptionDue DateResolved
Troubleshoot, repair & provide electrician's report for the inoperable ground detection system on the 120v electrical panel. 46 CFR 111.05-21Nov 12, 13Yes
Resolved DateResolution
Oct 29, 13Vessel provided documentation that the ground detection system is fully operational. Vessel indicated that a bad transformer was the cause of the problem.
SystemSubsystemCause
Operations/ManagementPollution
DescriptionDue DateResolved
Vessel does not have an approved Volatile Organic Compounds (VOC) Management Plan onboard. Vessel is prohibited from carrying crude oil on an international voyage. MARPOL Annex VI Reg. 15. (25NOV13) Extended due date from 29NOV to 13DEC.Dec 13, 13Yes
Resolved DateResolution
Dec 02, 13Vessel provided copy of MSC approval letter (Serial #C1-1304030) dated 26NOV2013 for VOC management plan. Copies uploaded to MISLE.
SystemSubsystemCause
Deck/CargoVapor Control Systems
DescriptionDue DateResolved
Vessel must demonstrate proper testing of intrinsically safe overfill control system. 46 CFR 39.20-9 (b)(3) (25NOV13) Extended due date from 29NOV to 13DEC. Extended due date from 13DEC to 29DEC.Dec 29, 13Yes
Resolved DateResolution
Dec 31, 13Verified proper operation of overfill alarm system, including the tether-plug for use by shoreside facilities.
4690684 SOUTH PORTLAND, Maine Aug 19, 13 Vessel Transfer Monitor - Approved Inspection
4509727 STATEN ISLAND, New York Jan 03, 13 Vessel Inspection - Agency Action Complete
4456195 STATEN ISLAND, New York Oct 02, 12 Facility Transfer Monitor - Agency Action Complete
4327105 BOSTON, Massachusetts May 29, 12 Vessel Inspection - Approved Inspection
4294761 BOSTON, Massachusetts Apr 24, 12 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
EngineeringShafting/Propeller Arrangements
DescriptionDue DateResolved
Failure of hydraulic oil seal on bow thruster controllable pitch propeller. Make repairs, provide technical report and conduct satisfactory test in the presence of Coast Guard Marine Inspector.Jun 25, 12Yes
Resolved DateResolution
May 29, 12Vessel submitted class survey report from ABS tech clearing oil seal on bow thruster.
4217372 STATEN ISLAND, New York Jan 04, 12 Vessel Inspection - Agency Action Complete
4167294 BOSTON, Massachusetts Sep 21, 11 Vessel Transfer Monitor - Agency Action Complete
3849394 STATEN ISLAND, New York Sep 14, 10 Vessel Inspection - Agency Action Complete
3719792 STATEN ISLAND, New York Apr 19, 10 Vessel Inspection - Agency Action Complete
3650349 STATEN ISLAND, New York Dec 15, 09 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
ElectricalElectric Generation Source (service)Unknown
DescriptionDue DateResolved
Generator #1 is not to be operated until a servicing technician evaluates cause and an corrective repair of said fire/failure to gen set. Provide USCG with copy of servicing report.Yes
Resolved DateResolution
Apr 19, 10Received documentation from General Marine Electric LLC, attesting to the satisfactory replacement and testing of the 550KW generator onboard. Copy Attached electronically.
3675842 WASHINGTON, District of Columbia Dec 14, 09 Incident Investigation - Agency Action Complete
3601950 STATEN ISLAND, New York Sep 22, 09 Vessel Inspection - Agency Action Complete
3569731 STATEN ISLAND, New York Aug 13, 09 Vessel Inspection - Agency Action Complete
3378022 STATEN ISLAND, New York Dec 11, 08 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
DocumentationCertificates/Documents
DescriptionDue DateResolved
COI route and conditions is limited to domestic service until company decides on intentions of MARPOL Annex II regulations. See most recent special note.Yes
Resolved DateResolution
May 19, 09Notified by operator that they wish to operate with Annex I cargoes only and in international service. Amended COI and CAA accordingly.
3364501 Portsmouth, Virginia Nov 05, 08 Vessel Inspection - Approved Inspection
3134895 Houston, Texas Jan 23, 08 Vessel Inspection - Approved Inspection
3008153 STURGEON BAY, Wisconsin Jun 13, 07 Vessel Inspection - Agency Action Complete
2931007 STURGEON BAY, Wisconsin May 15, 07 Vessel Inspection - Agency Action Complete
2854612 Houston, Texas Jan 12, 07 Vessel Inspection - Approved Inspection
2778918 Washington, District of Columbia Sep 15, 06 Vessel Inspection - Administrative Action
2778358 Washington, District of Columbia Sep 14, 06 Vessel Inspection - Security Plan Approved by MSC
2544551 STATEN ISLAND, New York Dec 02, 05 Vessel Inspection - Agency Action Complete
2536600 Buffalo, New York Nov 17, 05 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
Make double bottom tanks 1s, 2s, 3s, 4s, and 5s available for inspeciton in order to assess possible damage incurred from 11/16/2005 groudning in the Welland Canal. Dive survey dated 11/16 noted abrasions running fore and aft between frames 12-30 and 38-45 in way of the turn of the bilge.Dec 01, 05Yes
Resolved DateResolution
Dec 02, 05
2536367 WASHINGTON, District of Columbia Nov 15, 05 Incident Investigation - Agency Action Complete
2479638 STURGEON BAY, Wisconsin Oct 28, 05 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
DocumentationCertificates/Documents
DescriptionDue DateResolved
Prior to carrying cargo, barge must have valid Certificate of Documentation.Nov 04, 05Yes
Resolved DateResolution
Nov 04, 05
2509235 Washington, District of Columbia Oct 06, 05 Vessel Inspection - Security Plan Approved by MSC
Documents Issued Expires Agency
Cargo Authority Attachment August 11,2009 USCG
Certificate of Approval October 28,2005 N/A
CERTIFICATE OF DOCUMENTATION September 23,2021 October 31,2022 USCG
Certificate of Inspection September 14,2015 September 14,2020 USCG
Certificate of Inspection - Amended September 14,2015 September 14,2020 USCG
Classification Document October 8,2010 October 26,2015 ABS
International Load Line Certificate October 8,2010 October 8,2015 ABS
International Oil Pollution Prevention Certificate October 8,2010 October 8,2015 ABS
ISM - Document Of Compliance December 24,2011 November 14,2016 ABS
Load Line Certificate (Coastwise) October 8,2010 October 8,2015 ABS
NLS Certificate November 3,2015 September 14,2020 N/A
Stability Book October 26,2005 N/A
Stability Letter November 1,2005 N/A
Tonnage Certificate, International October 24,2005 ABS