Gm 11103
Print Q88   
IMO/VIN Callsign Flag Service Year
1170699 WDG9360 UNITED STATES Tank Barge 2005
Activity# Port Date Activity - Description Deficiencies
7499837 Morgan City, Louisiana Aug 08, 22 Vessel Inspection - Approved Inspection
7465388 PHILADELPHIA, Pennsylvania Jun 01, 22 Vessel Inspection - Approved Inspection
7301974 STATEN ISLAND, New York Sep 20, 21 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
07 - Fire SafetyN/A - No Subsystem
DescriptionDue DateResolved
If the voltage of a distribution system is less than 1,00 volts, a tank vessel must not have a grounded distribution system. A ground was detected via the ground detection at the 480 V panel. Provide electrician report that ground has been eliminated. 46 CFR 111.05-19(a), 705 c- rectify def in 7 daysSep 27, 21Yes
Resolved DateResolution
Sep 21, 21
7023642 STATEN ISLAND, New York Aug 03, 20 Vessel Inspection - Approved Inspection
7012429 PHILADELPHIA, Pennsylvania Jul 21, 20 Vessel Inspection - Agency Action Complete
  8
SystemSubsystemCause
13 - Propulsion and Auxiliary MachineryN/A - No Subsystem
DescriptionDue DateResolved
#1 Generator was not onboard at the time of inspection. Prove proper operation and conduct test of alarms and shutdowns prior to use in service in presence of attending CG marine inspector.Yes
Resolved DateResolution
Aug 03, 20Generator installed and conducted visual inspection, overspeed trip, and low lube oil shutdown.
SystemSubsystemCause
02 - Structural ConditionsN/A - No Subsystem
DescriptionDue DateResolved
#1 Starboard Cargo hatch cover was leaking cargo vapors when closed. Make adjustments and prove proper operation.Yes
Resolved DateResolution
Aug 03, 20Cargo hatch cover gasket replaced. Conducted leak test with complressed air via manometer and soapy water solution inspecting area for leaks. All sat.
SystemSubsystemCause
09 - Working and Living Conditions092 - Working Conditions
DescriptionDue DateResolved
A hydraulic leak was identified on the starboard side crane. Make repairs and prove proper operation.Yes
Resolved DateResolution
Aug 03, 20Third party company conducted repairs to hydraulic winch. Reviewed service report.
SystemSubsystemCause
11 - Life Saving AppliancesN/A - No Subsystem
DescriptionDue DateResolved
Renew faded SOLAS stickers on each deck house.Yes
Resolved DateResolution
Aug 03, 20New stickers were installed and verified by attending MI.
SystemSubsystemCause
02 - Structural ConditionsN/A - No Subsystem
DescriptionDue DateResolved
Steel wastage was identified underneath both deck houses. Gauge suspect areas and prove sufficient steel to prevent load line and vapor tightness concerns.Yes
Resolved DateResolution
Aug 04, 20ABS oversaw repairs and provided report attesting to temporary repairs scheduled to be permanently repaired on their next scheduled dry dock.
SystemSubsystemCause
09 - Working and Living Conditions092 - Working Conditions
DescriptionDue DateResolved
The #2 generator expansion tank is leaking into unknown area. Find source of leak and make repairs.Yes
Resolved DateResolution
Aug 03, 20ABS surveyor oversaw repair and provided report attesting to repairs.
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No Subsystem
DescriptionDue DateResolved
The thermal fluid heater was not operated or tested during the inspection due to type of cargo onboard. Prove proper operation and conduct operational tests and checks in presence of attending CG marine inspector prior to operation of the thermal fluid heater.Yes
Resolved DateResolution
Aug 05, 20Company informed CG the thermal fluid heater has been locked out, tagged out of service.
SystemSubsystemCause
09 - Working and Living Conditions092 - Working Conditions
DescriptionDue DateResolved
Wire channels under the starboard deck house are wasted out. Make repairs and prove satisfaction to CG inspectorYes
Resolved DateResolution
Aug 03, 20Wire channels replaced, attending MI inspected. All sat.
6895378 PHILADELPHIA, Pennsylvania Jan 23, 20 Vessel Inspection - Approved Inspection
6808096 PHILADELPHIA, Pennsylvania Sep 11, 19 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
11 - Life Saving AppliancesN/A - No Subsystem
DescriptionDue DateResolved
Replace expired batteries in lifebuoy self-igniting lights. 46 CFR 199.70(a)(3)(ii)Yes
Resolved DateResolution
Oct 23, 19Received e-mailed receipts and photos of replacement batteries on GM 11103.
SystemSubsystemCause
07 - Fire SafetyN/A - No Subsystem
DescriptionDue DateResolved
Replace the portable fire extinguisher brackets located on the starboard bow and aft of the starboard manifold with approved fire extinguisher brackets. 46 CFR 34.05-10Yes
Resolved DateResolution
Oct 23, 19Received e-mailed receipts and photos of replacement fire extinguisher brackets installed on GM 11103.
6742913 STATEN ISLAND, New York Jul 09, 19 Vessel Inspection - Approved Inspection
6677334 BOSTON, Massachusetts May 05, 19 Vessel Transfer Monitor - Approved Inspection
6455051 PHILADELPHIA, Pennsylvania Jun 27, 18 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
99 - OtherN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
Current Load Line shall be marked with contrasting color. 46 CFR 42.13-40Jun 28, 18Yes
Resolved DateResolution
Jun 28, 18Load line was painted during inspection.
SystemSubsystemCause
13 - Propulsion and Auxiliary MachineryN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
Prove proper operation of overspeed and low lube oil shutdowns on the #2 auxiliary generator prior to running generator. 46 CFR 111.12-1Jul 12, 18Yes
Resolved DateResolution
Jul 12, 18Received report from tech, all sat.
6366365 STATEN ISLAND, New York Mar 06, 18 Vessel Inspection - Agency Action Complete
6302463 BOSTON, Massachusetts Nov 07, 17 Vessel Transfer Monitor - Approved Inspection
6161756 Morgan City, Louisiana May 31, 17 Vessel Inspection - Approved Inspection
5825736 PHILADELPHIA, Pennsylvania Feb 24, 16 Vessel Inspection - Approved Inspection
5061592 Houma, Louisiana Feb 02, 15 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
LifesavingInflatable LiferaftsImproper Installation
DescriptionDue DateResolved
The installed life rafts were not mounted in a way that they could be easily deployed over the side of the vessel. The raft would have had to be thrown at least 7 feet to clear the main deck. As such required vessel to install a launching device to ensure that the rafts would not crash on the deck below when deployed.Yes
Resolved DateResolution
Feb 02, 15The vessel''s crew welded "ramps" for each liferaft to allow for easy deployment over the side of the vessel. Cleared at end of inspection. Crew used pipes welded to the superstructure to accomplish this.
5050231 Houma, Louisiana Jan 12, 15 Vessel Inspection - Approved Inspection
5046080 Houma, Louisiana Dec 31, 14 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
DocumentationCertificates/Documents
DescriptionDue DateResolved
Vessel must complete satisfactory Hull/ISE inspections prior to cargo operationsYes
Resolved DateResolution
Jan 28, 15Vessel completed Hull/ISE inspection on 01/12/2015.
4986685 TEXAS CITY, Texas Sep 17, 14 Vessel Inspection - Approved Inspection
4974444 New Orleans, Louisiana Sep 05, 14 Vessel Inspection - Approved Inspection
  3
SystemSubsystemCause
EngineeringDiesel Engine (auxiliary)
DescriptionDue DateResolved
Crew could not prove proper operation of the #1, #2, and #3 ships generators high engine temperature alarms. Prove proper operation of the high temperature alarms.Oct 05, 14Yes
Resolved DateResolution
Sep 17, 14Completed testing of High engine temperature alarm on all 3 generators - all sat
SystemSubsystemCause
EngineeringDiesel Engine (auxiliary)
DescriptionDue DateResolved
Crew failed to prove operation of #2 ships generators loss of lube oil alarm.Oct 05, 14Yes
Resolved DateResolution
Oct 05, 14Crew replaced faulty alarm sensor and proved proper operation of engine alarm to the attending marine inspector.
SystemSubsystemCause
ElectricalElectrical Distribution System (service)
DescriptionDue DateResolved
Vessel crew could not demonstrate proper operation of the #2 and #3 ships generator under voltage relay. Prove proper operation of under voltage relays.Oct 05, 14Yes
Resolved DateResolution
Sep 17, 14Vessel has replaced under voltage for the #2 and #3 generator tested both generators - all sat.
4739762 Houston, Texas Oct 23, 13 Vessel Inspection - Approved Inspection
4713996 CORPUS CHRISTI, Texas Sep 13, 13 Vessel Inspection - Approved Inspection
4666084 CORPUS CHRISTI, Texas Jul 27, 13 Facility Transfer Monitor - Approved Inspection
4660998 CORPUS CHRISTI, Texas Jul 18, 13 Vessel Inspection - Approved Inspection
  3
SystemSubsystemCause
EngineeringFuel Oil Service System
DescriptionDue DateResolved
Fuel hoses on generators were longer than 30 inches and were not SAE J1942.Sep 02, 13Yes
Resolved DateResolution
Sep 11, 13Vessel installed fuel hose type SAE J1942 and in lenghts not exceeding 30 inches.
SystemSubsystemCause
ElectricalElectric Generation Source (service)
DescriptionDue DateResolved
Operator could not perform reverse power relay test.Aug 18, 13Yes
Resolved DateResolution
Jul 19, 13Operator successfully completed reverse power relay test with Coast Guard Inspector.
SystemSubsystemCause
Deck/CargoCargo Heating
DescriptionDue DateResolved
Operator could not start thermal fluid heater.Aug 18, 13Yes
Resolved DateResolution
Jul 19, 13Operator successfuly started thermal fluid heater and tested alarms.
4504680 New Orleans, Louisiana Dec 19, 12 Vessel Inspection - Approved Inspection
4423336 New Orleans, Louisiana Aug 27, 12 Vessel Inspection - Approved Inspection
4388159 New Orleans, Louisiana Jul 26, 12 Vessel Inspection - Approved Inspection
4317986 TEXAS CITY, Texas May 21, 12 Vessel Inspection - Approved Inspection
4000308 Houma, Louisiana May 02, 11 Vessel Inspection - Approved Inspection
  3
SystemSubsystemCause
LifesavingLifebuoys
DescriptionDue DateResolved
(4) lifebouys require to be changed due to not being USCG approved.May 18, 11Yes
Resolved DateResolution
May 11, 11(4) new, approved USCG lifebouys properly stowed.
SystemSubsystemCause
ElectricalLighting (emergency)
DescriptionDue DateResolved
Barge requires additional E-Lights in following spaces: Ballast Pumproom, Aft Rake, Bow Thruster rooms to the satisfaction of attending marine inspector.Jun 13, 11Yes
Resolved DateResolution
Jun 07, 11Verified all E-Lights in the following spaces: Ballast Pump Room, Aft Rake, and Bow Thruster. All E-Lights were operational. All Sat.
SystemSubsystemCause
Deck/CargoCargo Stowage
DescriptionDue DateResolved
Port and Starboard Deck Cranes portable remote control cables unsafe/unsat. Replace/ Renew to orignial condition.May 18, 11Yes
Resolved DateResolution
May 10, 11Port and Starboard Deck Cranes, new portable remote control cables installed.
3883185 TOLEDO, Ohio Nov 02, 10 Vessel Transfer Monitor - Agency Action Complete
3741096 Houston, Texas May 18, 10 Vessel Inspection - Approved Inspection
3667181 Morgan City, Louisiana Jan 21, 10 Vessel Inspection - Approved Inspection
3656660 Morgan City, Louisiana Dec 30, 09 Vessel Inspection - Approved Inspection
3664736 Morgan City, Louisiana Dec 28, 09 Vessel Inspection - Approved Inspection
3591050 STATEN ISLAND, New York Sep 10, 09 Vessel Inspection - Agency Action Complete
3393939 Baltimore, Maryland Jan 08, 09 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
LifesavingInflatable Liferafts
DescriptionDue DateResolved
Both barge life raft certificates of re-inspection state that raft first aid kits are expired. starboard, 10-08 and port 12-08. last sevicing was 9-08. provide proof of validity.Feb 08, 09Yes
Resolved DateResolution
Jan 14, 09Kit remains current until next servicing date.
3387918 WASHINGTON, District of Columbia Jan 03, 09 Incident Investigation - Agency Action Complete
3330047 STATEN ISLAND, New York Sep 22, 08 Vessel Inspection - Agency Action Complete
  4
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
Properly stencil all oil cargo hoses Oil Service Only and MAWP 150 psi.Oct 23, 08Yes
Resolved DateResolution
Oct 14, 08Received pictures from vessel rep showing that oil cargo hoses had been stenciled properly. Deficiency cleared.
SystemSubsystemCause
EngineeringGenerator (propulsion/auxiliary-electric)
DescriptionDue DateResolved
Prove proper operation of low lube oil test on all gensets.Oct 23, 08Yes
Resolved DateResolution
Nov 06, 08All gensets tested for low lube oil pressure shutdown, all operated satisfactory. Deficiency cleared.
SystemSubsystemCause
ElectricalLighting (service)
DescriptionDue DateResolved
Repair junction box on Port side Nav light to original condition.Oct 23, 08Yes
Resolved DateResolution
Oct 14, 08Received pictures from vessel rep with satisfactory repairs of junction box completed. Deficiency cleared.
SystemSubsystemCause
Deck/CargoCargo Heating
DescriptionDue DateResolved
The Themal Fluid Heater was not inspected internally at last peridic inspection. TFH to be opened and visually inspected at next annual exam.Sep 30, 09Yes
Resolved DateResolution
Sep 10, 09
3125814 STATEN ISLAND, New York Jan 07, 08 Vessel Inspection - Agency Action Complete
3036515 STATEN ISLAND, New York Aug 23, 07 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
ElectricalElectric Generation Source (service)Unknown
DescriptionDue DateResolved
Demonstrate overspeed shutdown of #1 generator.Sep 24, 07Yes
Resolved DateResolution
Sep 10, 07Verified proper operation of over speed shutdown on #1 generator.
2871257 STATEN ISLAND, New York Feb 12, 07 Facility Transfer Monitor - Approved Inspection
2844306 Arlington, Virginia Dec 21, 06 Enforcement - Payment Received
2839649 STATEN ISLAND, New York Dec 13, 06 Enforcement - Agency Action Complete
2839647 STATEN ISLAND, New York Dec 13, 06 Enforcement - Agency Action Complete
2830057 WASHINGTON, District of Columbia Nov 17, 06 Incident Investigation - Agency Action Complete
2808563 STATEN ISLAND, New York Oct 26, 06 Facility Transfer Monitor - Approved Inspection
2782681 STATEN ISLAND, New York Sep 20, 06 Vessel Inspection - Approved Inspection
2778896 Washington, District of Columbia Sep 15, 06 Vessel Inspection - Administrative Action
2778356 Washington, District of Columbia Sep 14, 06 Vessel Inspection - Security Plan Approved by MSC
2587357 STATEN ISLAND, New York Feb 17, 06 Vessel Transfer Monitor - Approved Inspection
2582589 STATEN ISLAND, New York Feb 09, 06 Enforcement - Agency Action Complete
2574033 WASHINGTON, District of Columbia Jan 25, 06 Incident Investigation - Agency Action Complete
2399062 Washington, District of Columbia Jun 22, 05 Vessel Inspection - Security Plan Approved by MSC
2375462 STURGEON BAY, Wisconsin Jan 03, 05 Vessel Inspection - Approved Inspection
Documents Issued Expires Agency
Cargo Authority Attachment June 1,2022 N/A
CERTIFICATE OF DOCUMENTATION February 7,2022 February 28,2023 USCG
Certificate of Inspection May 19,2010 May 19,2015 N/A
Certificate of Inspection - Amended May 19,2010 May 19,2015 N/A
Classification Document June 30,2005 November 29,2005 N/A
International Load Line Certificate June 30,2005 November 29,2005 N/A
International Oil Pollution Prevention Certificate September 5,2014 June 29,2015 ABS
ISM - Document Of Compliance November 9,2006 November 14,2011 ABS
ISM - Safety Management Certificate November 11,2005 November 10,2010 ABS
Load Line Certificate (Coastwise) June 30,2005 June 29,2010 N/A
NLS Certificate October 9,2009 June 30,2010 N/A
Stability Book June 24,2005 N/A
Tonnage Certificate, International April 15,2014 ABS