Tenjun
Print Q88   
IMO/VIN Callsign Flag Service Year
9343390 3ETD4 PANAMA Tank Ship 2008
Activity# Port Date Activity - Description Deficiencies
7423218 TEXAS CITY, Texas Apr 09, 22 Vessel Inspection - Approved Inspection
  3
SystemSubsystemCause
07 - Fire SafetyN/A - No SubsystemPlaced in Improper Service
DescriptionDue DateResolved
DOORS REQUIRED TO BE SELF-CLOSING SHALL NOT BE FITTED WITH HOLD-BACK HOOKS. PSCO OBSERVED 3 SELF-CLOSING FIRE DOORS ABOVE THE "A" DECK CORRIDOR WITH HOLD-BACK HOOKS. 74SOLAS(04)II-2/9.4.2.2Apr 09, 22Yes
Resolved DateResolution
Apr 09, 22
SystemSubsystemCause
07 - Fire SafetyN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
NO ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN ANY SPACE WHERE FLAMMABLE MIXTURES ARE LIABLE TO COLLECT INCLUDING THOSE ONBOARD TANKERS OF A TYPE WHICH WILL NOT IGNITE THE MIXTURES CONCERNED. PSCO OBSERVED 05 EXPLOSION PROOF LIGHT FIXTURE CASINGS THAT WERE CRACKED IN THE CARGO PUMP ROOM. 74 SOLAS (04) II-I/45.10.2Yes
Resolved DateResolution
Jun 11, 22Vsl submitted class survey attesting to the repair of the lights in the cargo pump room.
SystemSubsystemCause
07 - Fire SafetyN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
WHERE THE ATMOSPHERE IN DOUBLE HULL SPACES CANNOT BE RELIABLY MEASURED USING FLEXIBLE GAS SAMPLING HOSES, SUCH SPACES SHALL BE FITTED WITH PERMANENT GAS SAMPLING LINES. THE CONFIGURATION OF GAS SAMPLING LINES SHALL BE ADAPTED TO THE DESIGN OF SUCH SPACES. THE FIXED GAS SAMPLING SYSTEM WAS OBSERVED TO BE OUT OF CALIBRATION BY PSCO. 74SOLAS(04) II-2/4.5.7.2.2Apr 09, 22Yes
Resolved DateResolution
Apr 09, 22
6053860 Morgan City, Louisiana Dec 08, 16 Vessel Inspection - Approved Inspection
4581911 Morgan City, Louisiana May 02, 13 Vessel Inspection - Approved Inspection
4071353 Morgan City, Louisiana Jul 20, 11 Vessel Inspection - Approved Inspection
3715026 Morgan City, Louisiana Apr 12, 10 Vessel Inspection - Approved Inspection
3387419 Morgan City, Louisiana Jan 01, 09 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Deck/CargoInert Gas System
DescriptionDue DateResolved
Blower discharge high temperature alarm failed on the IGS. This caused the entire system to fail.Yes
Resolved DateResolution
Jan 04, 09CG verified proper operation of IGS
SystemSubsystemCause
ElectricalElectric Generation Source (emergency)
DescriptionDue DateResolved
The secondary starting arrangment for the emergency generator is inoperable due to broken starter. Emergency Generator is still opertional with battery start.Apr 12, 10Yes
Resolved DateResolution
Apr 12, 10replacement starter on board.
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel July 20,2011 July 20,2013 MORMS
Classification Document January 5,2012 September 19,2013 NKK
COC-TVE Annual April 18,2010 January 4,2011 N/A
COC-TVE Renewal May 4,2013 May 4,2015 N/A
International Load Line Certificate November 13,2008 September 16,2013 NKK
International Oil Pollution Prevention Certificate January 5,2012 September 16,2013 NKK
ISM - Document Of Compliance June 13,2012 June 11,2017 NKK
ISM - Safety Management Certificate October 12,2018 January 12,2024 N/A
Minimum Safe Manning Document October 7,2013 N/A
SOLAS Cargo Ship Safety Construction Certificate November 13,2008 September 16,2013 NKK
SOLAS Cargo Ship Safety Equipment Certificate November 19,2012 September 16,2013 NKK
SOLAS Cargo Ship Safety Radio Certificate November 13,2008 September 16,2013 NKK
Tonnage Certificate, International September 17,2008 N/A