Activity# Port Date Activity - Description Deficiencies
7069989 STATEN ISLAND, New York Sep 30, 20 Vessel Transfer Monitor - Approved Inspection
6916626 STATEN ISLAND, New York Feb 27, 20 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
09 - Working and Living Conditions092 - Working ConditionsImproper/Lack of Maintenance
DescriptionDue DateResolved
Eletrical installations on vessels must ensure: Protection of passengers, crew, other persons, and the vessel from eletrical hazards. During inspection, ground detection light was found to be out on the panel in the galley. Also, in the generator space, the panel indicated that there was a ground.Mar 12, 20Yes
Resolved DateResolution
Mar 05, 20Tech rep attended vessel and determined that a faulty heater was causing the ground. Report has been attached to this case.
6868217 STATEN ISLAND, New York Dec 06, 19 Vessel Inspection - Approved Inspection
6589309 STATEN ISLAND, New York Sep 27, 18 Vessel Inspection - Approved Inspection
6281703 STATEN ISLAND, New York Oct 05, 17 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Construction/LoadlineHullImproper/Lack of Maintenance
DescriptionDue DateResolved
See attached worklist for list of welds to be V/W.Nov 05, 19Yes
Resolved DateResolution
Feb 18, 20
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)Improper/Lack of Maintenance
DescriptionDue DateResolved
The bellow covers on the all three cargo pumps are not vapor tight. 46 CFR 111.105-31jOct 19, 17Yes
Resolved DateResolution
Oct 19, 17The bellows have been rewnewed to a vapor tight condition.
5967089 STATEN ISLAND, New York Aug 09, 16 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
ElectricalElectrical Distribution System (service)
DescriptionDue DateResolved
The ground detection lights on the 440V switchboard indicated either a ground or phase imbalance. Determine & isolate the source, tag out affected equipment, and perform necessary repairs. 46CFR111.01-1(a)(2)Aug 23, 16Yes
Resolved DateResolution
Aug 12, 16Ground/phase imbalance was corrected. Attending MI verified that ground was no longer present.
5946889 WASHINGTON, District of Columbia Jul 20, 16 Incident Investigation - Agency Action Complete
5727589 STATEN ISLAND, New York Sep 24, 15 Vessel Inspection - Approved Inspection
5211486 STATEN ISLAND, New York Aug 10, 15 Vessel Inspection - Agency Action Complete
  4
SystemSubsystemCause
ElectricalElectric Generation Source (service)
DescriptionDue DateResolved
Demonstrate proper operation of automatic shutdown upon loss of lubricating oil pressure to the bearings on the outboard generator.Sep 10, 15Yes
Resolved DateResolution
Aug 21, 15conducted satisfactory low l/o shutdown on the generator.
SystemSubsystemCause
ElectricalElectric Generation Source (service)
DescriptionDue DateResolved
Demonstrate proper operation of overspeed device that prevents speed of generator prime mover from exceeding the maximum rated speed by more than 15% on outboard generator.Sep 10, 15Yes
Resolved DateResolution
Aug 21, 15conducted satisfactory test of the overspedd shutdown on the generator.
SystemSubsystemCause
ElectricalElectric Generation Source (service)
DescriptionDue DateResolved
Vessel must demonstrate proper parallel operation of service generators.Sep 10, 15Yes
Resolved DateResolution
Sep 24, 15The paralleling capabilites have been removed from this barge.
SystemSubsystemCause
ElectricalElectrical Distribution System (service)
DescriptionDue DateResolved
Vessel must isolate and repair the ground in the 120V distribution system.Aug 18, 15Yes
Resolved DateResolution
Aug 21, 15ground detected and rectified, all sat.
5018657 STATEN ISLAND, New York Nov 05, 14 Vessel Inspection - Approved Inspection
4740987 STATEN ISLAND, New York Oct 25, 13 Vessel Inspection - Agency Action Complete
4728638 STATEN ISLAND, New York Oct 08, 13 Vessel Inspection - Agency Action Complete
  8
SystemSubsystemCause
EngineeringDiesel Engine (propulsion/auxiliary-electric)
DescriptionDue DateResolved
Demonstrate proper operation of an automatic shutdown upon loss of lubrication oil pressure to the bearings on each generator.Nov 08, 13Yes
Resolved DateResolution
Oct 31, 13Vessel conducted the test for lube oil shutdown.
SystemSubsystemCause
EngineeringDiesel Engine (propulsion/auxiliary-electric)
DescriptionDue DateResolved
Vessel must demonstrate proper operation of overspeed device that prevents speed of generator prime mover from exceeding the maximum rated speed by more than 15% on both generators.Nov 08, 13Yes
Resolved DateResolution
Oct 31, 13Vessel conducted the proper testing of the over speed for both generators onboard.
SystemSubsystemCause
EngineeringGenerator (propulsion/auxiliary-electric)
DescriptionDue DateResolved
Vessel must demonstrate reverse power relay. Extended due date from 08NOV to 22NOV per company request and need for marine electrician to troubleshoot transformer problems. Due to long delivery time of governor component, vessel is prohibited from paralleling generators until satisfactory demonstration of reverse power relay.Yes
Resolved DateResolution
Dec 01, 14Tested reverse power relay.
SystemSubsystemCause
EngineeringDiesel Engine (auxiliary)
DescriptionDue DateResolved
Vessel must label emergency shutdowns to cargo pumpsNov 08, 13Yes
Resolved DateResolution
Oct 31, 13Vessel labeled emergency shutdown for cargo pumps.
SystemSubsystemCause
Fire FightingMiscellaneous Items
DescriptionDue DateResolved
Vessel must make shaft penetrations for all cargo pumproom engines must be vapor tight. Vessel requested due date extension; Chief, Cargo Vessel Branch granted a 60 day repair period. Changed due date from 08NOV to 08DEC.Dec 08, 13Yes
Resolved DateResolution
Nov 07, 13Attended vessel and verified all three cargo pump shaft penetrations were gas-tight.
SystemSubsystemCause
Deck/CargoCargo Heating
DescriptionDue DateResolved
Vessel must prove proper operation of thermal fluid heater safety shutdowns.Nov 08, 13Yes
Resolved DateResolution
Oct 31, 13Vessel provided tech report for the satisfactory testing of the thermal fluid heater that was conducted on 24OCT2013.
SystemSubsystemCause
ElectricalElectric Supply System (service)
DescriptionDue DateResolved
Vessel must provide over current protection on nav light above generator space and install with approved wiring.Nov 08, 13Yes
Resolved DateResolution
Oct 31, 13Vessel removed and replaced Nav light with portable approved light.
SystemSubsystemCause
ElectricalElectric Supply System (service)
DescriptionDue DateResolved
Vessel must replace welding cable in all battery installations with marine grade cable.Nov 08, 13Yes
Resolved DateResolution
Oct 31, 13Vessel replaced cable with marine grade approved battery cable.
4535198 STATEN ISLAND, New York Feb 19, 13 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
DBL 32 has a crack on deck above three port void tank. Vessel may offload cargo, but must make permanent repair to affected area prior to future cargo operations.Yes
Resolved DateResolution
Feb 21, 13Damaged area cropped and repair insert satisfactorily fit up, welded, back gouged, and air tested (1.5 psi).
4481363 STATEN ISLAND, New York Oct 30, 12 Vessel Inspection - Agency Action Complete
4172157 STATEN ISLAND, New York Oct 20, 11 Vessel Inspection - Agency Action Complete
4052520 STATEN ISLAND, New York Jun 21, 11 Vessel Inspection - Approved Inspection
3819795 STATEN ISLAND, New York Aug 09, 10 Vessel Inspection - Agency Action Complete
3826482 STATEN ISLAND, New York Aug 08, 10 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
Vessel sustained damage to the midships, port side, at the knuckle of the lower deck when it allided with the M/V HANJIN COLOMBO. Prior to loading cargo, make necessary repairs to the satisfaction of attending Class Society Surveyor and Coast Guard Marine Inspector.Aug 09, 10Yes
Resolved DateResolution
Aug 14, 10Repairs were completed to the satisfaction of CG and ABS.
3833487 WASHINGTON, District of Columbia Aug 08, 10 Incident Investigation - Agency Action Complete
3664762 WASHINGTON, District of Columbia Dec 19, 09 Incident Investigation - Agency Action Complete
3628254 STATEN ISLAND, New York Nov 09, 09 Vessel Inspection - Agency Action Complete
3492322 STATEN ISLAND, New York May 31, 09 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Construction/LoadlineHullUnknown
DescriptionDue DateResolved
Make permanent repairs to damage forward port side rake IWO knuckle area approximately 6' draft line to the satisfaction of attending coast guard marine inspector and before loading cargo.Yes
Resolved DateResolution
Jun 04, 09Received ABS report from class surveyor Justin Marsac, noting repairs sat and complete to damaged area.
3669534 WASHINGTON, District of Columbia May 31, 09 Incident Investigation - Agency Action Complete
3416593 WASHINGTON, District of Columbia Feb 05, 09 Incident Investigation - Agency Action Complete
3365320 STATEN ISLAND, New York Nov 24, 08 Vessel Inspection - Agency Action Complete
3356860 STATEN ISLAND, New York Nov 03, 08 Vessel Inspection - Agency Action Complete
3356945 WASHINGTON, District of Columbia Nov 03, 08 Incident Investigation - Agency Action Complete
3081444 STATEN ISLAND, New York Oct 17, 07 Vessel Inspection - Agency Action Complete
3071298 STATEN ISLAND, New York Oct 02, 07 Enforcement - Agency Action Complete
3054158 WASHINGTON, District of Columbia Sep 08, 07 Incident Investigation - Agency Action Complete
3011056 STATEN ISLAND, New York Jul 29, 07 Vessel Inspection - Agency Action Complete
  2
SystemSubsystemCause
Construction/LoadlineHullDamaged By Earlier Event
DescriptionDue DateResolved
Make Temporary repairs prior to trip to Albany Ny.Yes
Resolved DateResolution
Aug 05, 07Permanent repairs completed.
SystemSubsystemCause
Construction/LoadlineHullDamaged By Earlier Event
DescriptionDue DateResolved
Prior to loading cargo after Albany, NY, submit temporary repair plan to extend commercial operations until Sept07 for drydocking.Yes
Resolved DateResolution
Aug 05, 07Permanent repairs completed. Cargo operations cleared to resume.
3020323 WASHINGTON, District of Columbia Jul 29, 07 Incident Investigation - Agency Action Complete
2782999 STATEN ISLAND, New York Sep 20, 06 Vessel Inspection - Approved Inspection
2594819 STATEN ISLAND, New York Feb 16, 06 Facility Transfer Monitor - Approved Inspection
2504525 STATEN ISLAND, New York Sep 30, 05 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Fire FightingSemiportable Chemical-Foam Fire ExtinguishersImproper/Lack of Maintenance
DescriptionDue DateResolved
Vessels B-V extinguisher is not of adequate size for the area to be protected. Provide B-V extinguisher(s) to satisfy the requirements of 46CFR34.50-10(a) taking account of 46CFR34.50-20.Oct 30, 05Yes
Resolved DateResolution
Sep 20, 06Vessel installed a hose of adequate size to cover deck area.
2253966 WASHINGTON, District of Columbia Dec 05, 04 Incident Investigation - Agency Action Complete
2229209 STATEN ISLAND, New York Oct 27, 04 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
ElectricalLighting (service)Unknown
DescriptionDue DateResolved
No light in the pump room (vsl conducts night ops)Nov 27, 04Yes
Resolved DateResolution
Sep 30, 05Verified installation of lighting in all pump engine houses.
2220119 STATEN ISLAND, New York Oct 13, 04 Vessel Inspection - Agency Action Complete
2114970 STATEN ISLAND, New York Apr 12, 04 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
Make proper repairs to damaged area in forepeak to satisfaction of attending ABS surveyor or USCG Marine Inspector prior to commercial operations.Yes
Resolved DateResolution
Apr 15, 04
2049412 WASHINGTON, District of Columbia Apr 10, 04 Incident Investigation - Agency Action Complete
2006062 STATEN ISLAND, New York Feb 13, 04 Vessel Inspection - Approved Inspection
1985240 Washington, District of Columbia Dec 31, 03 Vessel Inspection - Security Plan Approved by MSC
1928666 STATEN ISLAND, New York Oct 15, 03 Vessel Inspection - Agency Action Complete
1679976 STATEN ISLAND, New York Sep 25, 02 Vessel Inspection - Administrative Action
1630024 STATEN ISLAND, New York Jun 12, 02 Enforcement - Agency Action Complete
1478811 STATEN ISLAND, New York Jan 15, 02 Enforcement - Agency Action Complete
1475135 STATEN ISLAND, New York Jan 04, 02 Vessel Inspection - Agency Action Complete
767476 STATEN ISLAND, New York Dec 10, 01 Enforcement - Payment Received
211592 WASHINGTON, District of Columbia Dec 07, 01 Incident Investigation - Agency Action Complete
502917 STATEN ISLAND, New York Aug 30, 01 Vessel Transfer Monitor - Approved Inspection
87444 WASHINGTON, District of Columbia Feb 05, 01 Incident Investigation - Agency Action Complete
1426515 STATEN ISLAND, New York Jan 27, 01 Vessel Inspection - Agency Action Complete
1420402 STATEN ISLAND, New York Oct 06, 00 Vessel Inspection - Agency Action Complete
  17
SystemSubsystemCause
Accommodation/Occupational SafetyUnknown
DescriptionDue DateResolved
Make air rcvr ready for USCG internal inspection or hydro at 1.5 x MAWP. Oct 06, 00Yes
Resolved DateResolution
Oct 23, 00
SystemSubsystemCause
Deck/CargoUnknown
DescriptionDue DateResolved
Prove proper operation and testing of thermal fluid heater IAW approved opsmanual. TFH was inoperative with parts on order so test was not conducted. Sep 24, 15Yes
Resolved DateResolution
Sep 24, 15Thermal fluid heater is working properly and was satisfactorily tested on our last COI inspection dated 10AUG15.
SystemSubsystemCause
Accommodation/Occupational SafetyUnknown
DescriptionDue DateResolved
Prove proper operation of air compressor & relief valve. Oct 06, 00Yes
Resolved DateResolution
Oct 23, 00
SystemSubsystemCause
Deck/CargoUnknown
DescriptionDue DateResolved
Prove proper operation of cargo pump engines and shutdowns. Oct 06, 00Yes
Resolved DateResolution
Oct 23, 00
SystemSubsystemCause
NavigationUnknown
DescriptionDue DateResolved
Prove proper operation of nav lights. Daylight ops only until cleared by USCG. Oct 06, 00Yes
Resolved DateResolution
Oct 23, 00
SystemSubsystemCause
LifesavingUnknown
DescriptionDue DateResolved
Provide 12 rocket parachute flares in suitable container. Oct 06, 00Yes
Resolved DateResolution
Oct 23, 00
SystemSubsystemCause
LifesavingUnknown
DescriptionDue DateResolved
Provide 2 life jackets with lights and vsl name on them. Oct 06, 00Yes
Resolved DateResolution
Oct 23, 00
SystemSubsystemCause
LifesavingUnknown
DescriptionDue DateResolved
Provide approved line throwing apparatus on board IAW 46 CFR 199.170. Oct 06, 00Yes
Resolved DateResolution
Oct 23, 00
SystemSubsystemCause
Construction/LoadlineUnknown
DescriptionDue DateResolved
Provide bilge pumps for fwd/aft rakes. Oct 06, 00Yes
Resolved DateResolution
Oct 23, 00
SystemSubsystemCause
Deck/CargoUnknown
DescriptionDue DateResolved
Provide oil discharge removal equipment. Oct 06, 00Yes
Resolved DateResolution
Oct 23, 00
SystemSubsystemCause
DocumentationUnknown
DescriptionDue DateResolved
Provide person in charge designation. Oct 06, 00Yes
Resolved DateResolution
Oct 23, 00
SystemSubsystemCause
Fire FightingUnknown
DescriptionDue DateResolved
Provide proof of current fire extinguisher servicing. Oct 06, 00Yes
Resolved DateResolution
Oct 23, 00
SystemSubsystemCause
LifesavingUnknown
DescriptionDue DateResolved
Provide proof of current liferaft servicing. Oct 06, 00Yes
Resolved DateResolution
Oct 23, 00
SystemSubsystemCause
Deck/CargoUnknown
DescriptionDue DateResolved
Provide proof of piping, relief valve and cargo pressure gauge hydro/testing. Oct 06, 00Yes
Resolved DateResolution
Oct 23, 00
SystemSubsystemCause
DocumentationUnknown
DescriptionDue DateResolved
Provide transfer procedures, VRP, SOPEP, current COD decal, original COFR and proof of current enrollment in a drug/alcohol program. Oct 06, 00Yes
Resolved DateResolution
Oct 23, 00
SystemSubsystemCause
LifesavingUnknown
DescriptionDue DateResolved
Stencil vsl name on immersion suits. Oct 06, 00Yes
Resolved DateResolution
Oct 23, 00
SystemSubsystemCause
Deck/CargoUnknown
DescriptionDue DateResolved
Vsl crew was not on board so vsl rep chose not to test anchor windlass during initial visit. Oct 06, 00Yes
Resolved DateResolution
Oct 23, 00
818734 PHILADELPHIA, Pennsylvania Jun 26, 00 Vessel Inspection - Agency Action Complete
816952 Baltimore, Maryland Mar 11, 00 Vessel Inspection - Agency Action Complete
1369364 Baltimore, Maryland Oct 01, 99 Vessel Inspection - Agency Action Complete
  5
SystemSubsystemCause
Construction/LoadlineUnknown
DescriptionDue DateResolved
Appropriate holdbacks on all 3 cargo pump room doors. Oct 06, 99Yes
Resolved DateResolution
Oct 06, 99
SystemSubsystemCause
Deck/CargoUnknown
DescriptionDue DateResolved
Finish safety line on main deck for remote cargo pump emergency shutdowns. Oct 06, 99Yes
Resolved DateResolution
Oct 06, 99
SystemSubsystemCause
Deck/CargoUnknown
DescriptionDue DateResolved
Label ID on the Thermal Fluid Heater exhaust stack blowers. Oct 06, 99Yes
Resolved DateResolution
Oct 06, 99
SystemSubsystemCause
NavigationUnknown
DescriptionDue DateResolved
Operate special flashing and STBD running nav light. Oct 06, 99Yes
Resolved DateResolution
Oct 05, 99
SystemSubsystemCause
Construction/LoadlineUnknown
DescriptionDue DateResolved
Reinstall gaskets on Water tight doors.    x Oct 06, 99Yes
Resolved DateResolution
Oct 06, 99
1397265 Baltimore, Maryland Sep 30, 99 Vessel Inspection - Agency Action Complete
Documents Issued Expires Agency
CERTIFICATE OF DOCUMENTATION August 25,2020 September 30,2021 USCG
Certificate of Inspection September 30,2005 September 30,2010 N/A
Certificate of Inspection - Amended September 30,2005 September 30,2010 N/A
Classification Document November 29,2009 October 31,2014 ABS
ISM - Document Of Compliance October 26,2011 September 19,2016 ABS