Double Skin 19
Print Q88   
IMO/VIN Callsign Flag Service Year
1065658 WDH2082 UNITED STATES Tank Barge 1998
Activity# Port Date Activity - Description Deficiencies
7219157 Baltimore, Maryland Jun 08, 21 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
02 - Structural ConditionsN/A - No SubsystemInvalid
DescriptionDue DateResolved
46 CFR 91.40-3 2( c ) If during an internal structural , cargo tank examination, or underwater survey, damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the officer in charge, marine inspection, may require the vessel to be dry docked or otherwise taken out of service to further assess the extent of the damage and to effect permanent repairs. During internal structural exam minor cracks to in way of side transverse vertical and side longitudinal in side shell voids. The cracks were minor and the opposing side of each had good welds. There were 7 total spots throughout : 2 port (1) 3P (2) 4P (2) 5P (1) and 6S (1) . Grid and re-weld. Items to be completed by end of next scheduled dry dock in 2023. 46 CFR 91.40-3 2No
7154825 Baltimore, Maryland Mar 12, 21 Vessel Inspection - Approved Inspection
7076286 Baltimore, Maryland Oct 13, 20 Vessel Inspection - Approved Inspection
  5
SystemSubsystemCause
09 - Working and Living Conditions092 - Working ConditionsImproper/Lack of Maintenance
DescriptionDue DateResolved
01 - All cargo tank hatches must be clearly marked in not less than three inch lettering “Danger—Keep Out,” and all hatch covers must be closed and dogged down in such a way that the hatch cannot be opened by the use of bare hands alone. Markings on hatches were observed deteriorated and illegible. 46CFR35.05-15(b)(3)(ii)Oct 13, 20Yes
Resolved DateResolution
Mar 12, 21All appropriate hatches have been marked.
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No SubsystemInvalid
DescriptionDue DateResolved
Each hose must be marked with one of the following: For oil products, the words “OIL SERVICE," Each hose also must be marked with the following, Maximum allowable working pressure. 33CFR154.500(e)(2, 33CFR154.500(f)(1)Oct 13, 20Yes
Resolved DateResolution
Mar 12, 21All hoses have been properly marked.
SystemSubsystemCause
11 - Life Saving AppliancesN/A - No SubsystemImproper Installation
DescriptionDue DateResolved
Each liferaft must be stowed to permit manual release from its securing arrangements. Liferaft was not stowed in proper fashion to permit manual release. 46CFR31.36-1, 46CFR199.130(c)(1)Oct 13, 20Yes
Resolved DateResolution
Mar 12, 21Life raft has been removed.Vessel not required to have it onboard- Unmanned Barge.
SystemSubsystemCause
12 - Dangerous GoodsN/A - No SubsystemImproper Installation
DescriptionDue DateResolved
Fuel filters are required to meet standards specified by ASTM F 1201. Fuel filter onboard was not of type suitable for intended service. 46CFR56.60-1(b)Oct 13, 20Yes
Resolved DateResolution
Mar 11, 21Fuel filters have been replaced with the correct model.
SystemSubsystemCause
09 - Working and Living Conditions092 - Working ConditionsImproper/Lack of Maintenance
DescriptionDue DateResolved
The barge must have a working means for releasing the anchor that can be operated safely by one or two persons. Release means were inoperable for inspection. 46CFR32.15-15(f)Oct 13, 20Yes
Resolved DateResolution
Mar 12, 21Anchor was shown to be properly working.
6934986 Baltimore, Maryland Apr 03, 20 Vessel Inspection - Approved Inspection
6928692 ST PETERSBURG, Florida Mar 18, 20 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
03 - Water/Weathertight ConditionsN/A - No Subsystem
DescriptionDue DateResolved
If, during an internal structural examination, cargo tank internal examination, or underwater survey, damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the Officer in Charge, Marine Inspection, may require the vessel to be drydocked or otherwise taken out of service to further assess the extent of the damage and to effect permanent repairs. Watertight hatches for #1 Port and Starboard Voids, and Starboard Aft Peak found in wasted condition. Repair or replace . IAW: 46 CFR 31.10-21 (c)Apr 20, 20Yes
Resolved DateResolution
Apr 03, 20Inspected 03 new hatch covers. all sat.
6928692 Tampa, Florida Mar 18, 20 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
03 - Water/Weathertight ConditionsN/A - No Subsystem
DescriptionDue DateResolved
If, during an internal structural examination, cargo tank internal examination, or underwater survey, damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the Officer in Charge, Marine Inspection, may require the vessel to be drydocked or otherwise taken out of service to further assess the extent of the damage and to effect permanent repairs. Watertight hatches for #1 Port and Starboard Voids, and Starboard Aft Peak found in wasted condition. Repair or replace . IAW: 46 CFR 31.10-21 (c)Apr 20, 20Yes
Resolved DateResolution
Apr 03, 20Inspected 03 new hatch covers. all sat.
6792772 ST PETERSBURG, Florida Sep 09, 19 Vessel Inspection - Approved Inspection
  5
SystemSubsystemCause
02 - Structural ConditionsN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
DEF CODE: 02108 MI found electrical wiring going to the mast headlight switch not sealed. 46 CFR 111.81-1 ACTION:701 ACTION CODE:CYes
Resolved DateResolution
Sep 26, 19Switch sealed, def corrected to the satisfaction of the MI.
SystemSubsystemCause
02 - Structural ConditionsN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
DEFICIENCY CODE: 02108 MI found Hydrulic motor electrical box not sealed in the wire run side. Seal wire run to the attending MI satisfaction. 46 CFR 111.81-3 ACTION:701 ACTION CODE:CYes
Resolved DateResolution
Sep 30, 19Electrical box sealed, def corrected to the satisfaction of the MI.
SystemSubsystemCause
02 - Structural ConditionsN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
DEFICIENCY CODE: 02108 MI found receptacle outlet by the galley area with out a cover. Install proper cover for the receptacle to the MI satisfaction. 46 CFR 111.79-1 ACTION:701 ACTION TAKEN:CYes
Resolved DateResolution
Sep 26, 19Receptacle cover installed, def corrected to the satisfaction of the MI.
SystemSubsystemCause
07 - Fire SafetyN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
Deficiency Code: 07116 MI found #1 and #2 cargo man hole vents needs replacement. Replace vent mesh to the attending MI satisfaction. 46 CFR 32.55-25 ACTION:701 ACTION CODE:CYes
Resolved DateResolution
Sep 26, 19Flame screens replaced with new ones, def corrected to the satisfaction of the MI.
SystemSubsystemCause
09 - Working and Living Conditions092 - Working ConditionsImproper/Lack of Maintenance
DescriptionDue DateResolved
DEFICIENCY CODE: 09203 MI found light fixture diffuser broken in the gen set room. Replace diffuser to the satisfaction of attending MI. 46 CFR 111.75-20 ACTION:701 ACTION CODE:CYes
Resolved DateResolution
Sep 26, 19Light fixture replaced completly, def corrected to the satisfaction of the MI.
6792772 Tampa, Florida Sep 09, 19 Vessel Inspection - Approved Inspection
  5
SystemSubsystemCause
02 - Structural ConditionsN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
DEF CODE: 02108 MI found electrical wiring going to the mast headlight switch not sealed. 46 CFR 111.81-1 ACTION:701 ACTION CODE:CYes
Resolved DateResolution
Sep 26, 19Switch sealed, def corrected to the satisfaction of the MI.
SystemSubsystemCause
02 - Structural ConditionsN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
DEFICIENCY CODE: 02108 MI found Hydrulic motor electrical box not sealed in the wire run side. Seal wire run to the attending MI satisfaction. 46 CFR 111.81-3 ACTION:701 ACTION CODE:CYes
Resolved DateResolution
Sep 30, 19Electrical box sealed, def corrected to the satisfaction of the MI.
SystemSubsystemCause
02 - Structural ConditionsN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
DEFICIENCY CODE: 02108 MI found receptacle outlet by the galley area with out a cover. Install proper cover for the receptacle to the MI satisfaction. 46 CFR 111.79-1 ACTION:701 ACTION TAKEN:CYes
Resolved DateResolution
Sep 26, 19Receptacle cover installed, def corrected to the satisfaction of the MI.
SystemSubsystemCause
07 - Fire SafetyN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
Deficiency Code: 07116 MI found #1 and #2 cargo man hole vents needs replacement. Replace vent mesh to the attending MI satisfaction. 46 CFR 32.55-25 ACTION:701 ACTION CODE:CYes
Resolved DateResolution
Sep 26, 19Flame screens replaced with new ones, def corrected to the satisfaction of the MI.
SystemSubsystemCause
09 - Working and Living Conditions092 - Working ConditionsImproper/Lack of Maintenance
DescriptionDue DateResolved
DEFICIENCY CODE: 09203 MI found light fixture diffuser broken in the gen set room. Replace diffuser to the satisfaction of attending MI. 46 CFR 111.75-20 ACTION:701 ACTION CODE:CYes
Resolved DateResolution
Sep 26, 19Light fixture replaced completly, def corrected to the satisfaction of the MI.
6566115 ST PETERSBURG, Florida Sep 21, 18 Vessel Inspection - Approved Inspection
6566115 Tampa, Florida Sep 21, 18 Vessel Inspection - Approved Inspection
6482354 ST PETERSBURG, Florida Jul 17, 18 Vessel Inspection - Approved Inspection
6482354 Tampa, Florida Jul 17, 18 Vessel Inspection - Approved Inspection
6417048 ST PETERSBURG, Florida May 17, 18 Vessel Inspection - Approved Inspection
6417048 Tampa, Florida May 17, 18 Vessel Inspection - Approved Inspection
6385942 ST PETERSBURG, Florida Feb 07, 18 Vessel Transfer Monitor - Approved Inspection
6385942 Tampa, Florida Feb 07, 18 Vessel Transfer Monitor - Approved Inspection
6342896 WASHINGTON, District of Columbia Jan 20, 18 Incident Investigation - Agency Action Complete
6331821 WASHINGTON, District of Columbia Nov 30, 17 Incident Investigation - Agency Action Complete
6297659 PHILADELPHIA, Pennsylvania Oct 31, 17 Vessel Inspection - Approved Inspection
6234444 PHILADELPHIA, Pennsylvania Oct 27, 17 Vessel Inspection - Approved Inspection
6101778 WASHINGTON, District of Columbia Feb 10, 17 Incident Investigation - Agency Action Complete
6024530 PHILADELPHIA, Pennsylvania Oct 18, 16 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Construction/LoadlineHullImproper/Lack of Maintenance
DescriptionDue DateResolved
Complete attached worklist prior to receiving credit ISE.Yes
Resolved DateResolution
Oct 24, 16Completed all required repairs.
5843809 PHILADELPHIA, Pennsylvania Mar 31, 16 Vessel Inspection - Approved Inspection
  4
SystemSubsystemCause
Deck/CargoHolds/Tanks
DescriptionDue DateResolved
Prove proper operation of high level/overfill visual indicator for 2 stbd tank.Apr 22, 16Yes
Resolved DateResolution
Apr 20, 16Vessel repaired level indicator by replacing the contact magnet.
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
Provide valve postiion indicators for non-rising stem type valves in cargo system.Apr 22, 16Yes
Resolved DateResolution
Apr 20, 16Valve position indicators were installed on all required valves.
SystemSubsystemCause
LifesavingLifebuoys
DescriptionDue DateResolved
Relocate forward life ring buoy with water light to a location outside of the hazardous zone.Apr 22, 16Yes
Resolved DateResolution
Apr 20, 16Relocated buoy outside of hazard area.
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational Safety
DescriptionDue DateResolved
Repair port side railing, middle course, as original.Apr 22, 16Yes
Resolved DateResolution
Apr 20, 16Deck rail was bent back into place, welds appeared intact.
5125995 PHILADELPHIA, Pennsylvania May 04, 15 Facility Transfer Monitor - Approved Inspection
5078318 STATEN ISLAND, New York Mar 04, 15 Vessel Inspection - Approved Inspection
5041307 STATEN ISLAND, New York Dec 18, 14 Vessel Inspection - Agency Action Complete
4805747 STATEN ISLAND, New York Feb 25, 14 Vessel Inspection - Agency Action Complete
4754448 STATEN ISLAND, New York Nov 18, 13 Vessel Inspection - Agency Action Complete
4742335 Baltimore, Maryland Oct 24, 13 Vessel Inspection - Approved Inspection
4726236 Baltimore, Maryland Oct 01, 13 Vessel Inspection - Approved Inspection
4682975 STATEN ISLAND, New York Aug 13, 13 Vessel Inspection - Agency Action Complete
4537407 PHILADELPHIA, Pennsylvania Feb 22, 13 Vessel Inspection - Approved Inspection
4525790 PHILADELPHIA, Pennsylvania Jan 29, 13 Vessel Inspection - Approved Inspection
  5
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational Safety
DescriptionDue DateResolved
ADDRESS EXCESSIVE OIL IN AUXILIARY MACHINERY SPACE.Feb 12, 13Yes
Resolved DateResolution
Feb 12, 13
SystemSubsystemCause
LifesavingLifebuoys
DescriptionDue DateResolved
PROPERLY LABEL AFT LIFE RING BUOY WITH VESSEL NAME AND HAILING PORT.Feb 12, 13Yes
Resolved DateResolution
Feb 06, 13
SystemSubsystemCause
EngineeringCompressed Air System (control)
DescriptionDue DateResolved
PROVE PROPER OPERATION OF AIR COMPRESSOR RELIEF VALVE.Feb 12, 13Yes
Resolved DateResolution
Feb 06, 13
SystemSubsystemCause
ElectricalElectric Generation Source (service)
DescriptionDue DateResolved
PROVE PROPER OPERATION OF LOW LUBE OIL PRESSURE SHUTDOWN ON GENERATOR.Feb 12, 13Yes
Resolved DateResolution
Feb 06, 13
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
REPAIR/REPLACE TORN CARGO HOSE, 1127105-BFeb 12, 13Yes
Resolved DateResolution
Feb 06, 13
4217314 PHILADELPHIA, Pennsylvania Jan 03, 12 Vessel Inspection - Approved Inspection
4166193 PHILADELPHIA, Pennsylvania Oct 12, 11 Vessel Inspection - Approved Inspection
4052419 STATEN ISLAND, New York Jun 21, 11 Vessel Inspection - Approved Inspection
4047748 PHILADELPHIA, Pennsylvania Jun 14, 11 Vessel Inspection - Administrative Action
3936161 PHILADELPHIA, Pennsylvania Jan 31, 11 Vessel Inspection - Approved Inspection
3894207 STATEN ISLAND, New York Nov 19, 10 Vessel Inspection - Agency Action Complete
3664860 STATEN ISLAND, New York Jan 15, 10 Vessel Inspection - Agency Action Complete
  2
SystemSubsystemCause
Construction/LoadlineHullDamaged By Earlier Event
DescriptionDue DateResolved
#1 Cargo Port Cargo Tank deck plating punctured by fallen containers. Make temporary repairs to tank deck to prevent vapor escape prior to movement of barge.Yes
Resolved DateResolution
Oct 31, 17Def Administratively closed. Repairs completed in 2010 but def was never cleared.
SystemSubsystemCause
Construction/LoadlineHullDamaged By Earlier Event
DescriptionDue DateResolved
Take vessel out of service, gas free cargo tanks # 1 P&S and make available for USCG damage survey. Submit repair proposal & make permanent repairs to vessel prior to cargo operations.Yes
Resolved DateResolution
Jan 25, 10pressure test of welds conducted and passed on 1-25-2010.
3670664 WASHINGTON, District of Columbia Jan 15, 10 Incident Investigation - Agency Action Complete
3662604 STATEN ISLAND, New York Jan 12, 10 Vessel Inspection - Agency Action Complete
3422909 STATEN ISLAND, New York Feb 26, 09 Vessel Inspection - Agency Action Complete
3400943 WASHINGTON, District of Columbia Jan 24, 09 Incident Investigation - Agency Action Complete
3346463 STATEN ISLAND, New York Oct 09, 08 Vessel Inspection - Agency Action Complete
3122802 STATEN ISLAND, New York Dec 31, 07 Vessel Inspection - Agency Action Complete
3055831 STATEN ISLAND, New York Sep 12, 07 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Construction/LoadlineHullDamaged By Earlier Event
DescriptionDue DateResolved
Crop & renew damage to fwd rake/port corner (approx 3 ft x 2 ft).Oct 11, 07Yes
Resolved DateResolution
Sep 24, 07Permanent repairs completed.
2958466 STATEN ISLAND, New York Jun 11, 07 Vessel Inspection - Agency Action Complete
2911619 STATEN ISLAND, New York Apr 20, 07 Vessel Inspection - Agency Action Complete
2849278 STATEN ISLAND, New York Jan 03, 07 Vessel Inspection - Agency Action Complete
2525484 Portsmouth, Virginia Oct 31, 05 Vessel Inspection - Approved Inspection
2492170 Portsmouth, Virginia Sep 16, 05 Vessel Inspection - Approved Inspection
2426909 STATEN ISLAND, New York Jul 15, 05 Vessel Inspection - Agency Action Complete
2383661 STATEN ISLAND, New York Jun 10, 05 Vessel Inspection - Agency Action Complete
2274714 Portsmouth, Virginia Jan 14, 05 Vessel Inspection - Agency Action Complete
2263972 WASHINGTON, District of Columbia Dec 22, 04 Incident Investigation - Agency Action Complete
2261160 Portsmouth, Virginia Dec 17, 04 Vessel Inspection - Approved Inspection
2260013 Washington, District of Columbia Dec 15, 04 Vessel Inspection - Security Plan Approved by MSC
2255767 Portsmouth, Virginia Dec 08, 04 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Deck/CargoHolds/TanksUnknown
DescriptionDue DateResolved
Renew flame screens on all gooseneck cargo vent lines.Yes
Resolved DateResolution
Dec 14, 04Flame screens on all gooseneck cargo vent lines replaced.
1979692 Washington, District of Columbia Dec 30, 03 Vessel Inspection - Security Plan Approved by MSC
1900861 Portsmouth, Virginia Sep 15, 03 Vessel Inspection - Approved Inspection
1755085 WASHINGTON, District of Columbia Mar 06, 03 Incident Investigation - Agency Action Complete
1675233 Portsmouth, Virginia Sep 13, 02 Vessel Inspection - Approved Inspection
1493733 Jacksonville, Florida Mar 14, 02 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
DocumentationMarkings/PlacardsImproper Installation
DescriptionDue DateResolved
Provide vessel markings P&S bow and stern to show new owners name of vessel and hailing port. LEGACY COMPONENT DESC: Vessel Number (state)Yes
Resolved DateResolution
Oct 18, 02
1462263 Jacksonville, Florida Sep 11, 01 Vessel Inspection - Agency Action Complete
520930 Cape Canaveral, Florida Sep 08, 01 Vessel Transfer Monitor - Agency Action Complete
822835 Jacksonville, Florida Sep 29, 00 Vessel Inspection - Agency Action Complete
822919 Jacksonville, Florida Sep 15, 00 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Deck/CargoUnknown
DescriptionDue DateResolved
CONDUCT ANNUAL HYDROSTATIC TEST OF CARGO PIPING IN ACCORDANCE WITH 33 CFR 156.170. Sep 15, 00Yes
Resolved DateResolution
Sep 15, 00
804359 Jacksonville, Florida Nov 02, 99 Vessel Inspection - Agency Action Complete
489407 Cape Canaveral, Florida Jun 07, 99 Vessel Transfer Monitor - Agency Action Complete
513723 Cape Canaveral, Florida Apr 08, 99 Vessel Transfer Monitor - Agency Action Complete
789808 Jacksonville, Florida Jan 27, 99 Vessel Inspection - Agency Action Complete
441467 Cape Canaveral, Florida Jan 24, 99 Vessel Transfer Monitor - Agency Action Complete
450877 Cape Canaveral, Florida Jan 09, 99 Vessel Transfer Monitor - Agency Action Complete
503140 Cape Canaveral, Florida Nov 28, 98 Vessel Transfer Monitor - Agency Action Complete
1464774 TEXAS CITY, Texas Sep 18, 98 Vessel Inspection - Agency Action Complete
  2
SystemSubsystemCause
DocumentationUnknown
DescriptionDue DateResolved
PRIOR TO LOADING CARGO PROVIDE USCG MARINE INSPECTOR WITH AN ORIGINAL VALIDCOFR. Oct 14, 98Yes
Resolved DateResolution
Oct 14, 98
SystemSubsystemCause
Deck/CargoUnknown
DescriptionDue DateResolved
PRIOR TO LOADING CARGO, INSTALL FLAME SCREENS ON #1, 2, AND 3 P/S CARGO TANKS. Sep 18, 98Yes
Resolved DateResolution
Sep 18, 98
Documents Issued Expires Agency
CERTIFICATE OF DOCUMENTATION October 6,2021 October 31,2022 USCG
Certificate of Inspection September 16,2005 September 16,2010 N/A
Certificate of Inspection - Amended September 15,2000 September 15,2005 N/A