IMO/VIN
Callsign
Flag
Service
Year
9396787
9HOD9
MALTA
Tank Ship
2008
Activity#
Port
Date
Activity - Description
Deficiencies
6858254
New Orleans, Louisiana
Nov 21, 19
Vessel Inspection - Approved Inspection
6628018
San Pedro, California
Feb 19, 19
Vessel Inspection - Administrative Action
6612139
New Orleans, Louisiana
Jan 18, 19
Vessel Inspection - Administrative Action
6594057
Mobile, Alabama
Dec 13, 18
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause 04 - Emergency Systems N/A - No Subsystem
Description Due Date Resolved Electrical installations shall be such as to minimize the risk of fire and explosion from flammable products. PSCO noted (02) explosion proof emergency lighting fixture housings, located near forward portable life raft, are excessively corroded. Integrity of explosion proof appears intact. Replace in kind. Jan 12, 19 Yes
Resolved Date Resolution Feb 19, 19 Class report received attesting to satisfactory repair.
6594373
Mobile, Alabama
Dec 09, 18
Vessel Inspection - Approved Inspection
6280739
Houston, Texas
Oct 12, 17
Vessel Inspection - Approved Inspection
3
0
System Subsystem Cause Deck/Cargo Cargo Transfer/Lightering (liquid) Improper/Lack of Maintenance
Description Due Date Resolved 1135 Dangerous liquid chemicals in bulk- After any survey of the ship has been completed, no change shall be made in the fittings and material covered by the survey without the sanction of the administration except by direct replacement. PSCOs found evidence of soft patch on the #4 cargo tank drop line. SOLAS 74(2014) VII/10.1 Ref IBC 1.5.3.2. Oct 11, 17 Yes
Resolved Date Resolution Oct 20, 17 Received class report attesting to installation of new section of pipe and testing in presence of attending RINA surveyor.
System Subsystem Cause Deck/Cargo Cargo Transfer/Lightering (liquid) Improper/Lack of Maintenance
Description Due Date Resolved 1135 Dangerous liquid chemicals in bulk- The minimum wall thickness of cargo piping shall be within recognized standards and not less than that required in 5.1.1. Cargo line from steam condenser to slop tank (drain line) found wasted and holed. SOLAS 74(2014) VII/10.1 REF IBC Code 5.1, and 6.1. Oct 11, 17 Yes
Resolved Date Resolution Oct 20, 17 Received class report attesting to installation of new pipe, which was inspected and tested by attending RINA surveyor.
System Subsystem Cause Operations/Management Vessel Safety Management Invalid
Description Due Date Resolved 2535 Development of Shipboard Plans- The company shall establish procedures for key shipboard operations concerning the safety of personnel. Procedures for controlling narcotics state that they shall be kept in a locked cabinet or safe. PSCOs found a large bag of expired medication in an unlocked safety/fire locker on bridge deck. Found expired morphine in bag. 20 of the 50 listed on the inventory are unaccounted for. SOLAS 74(2014)IX/3.1 Ref ISM Code 7 Oct 11, 17 Yes
Resolved Date Resolution Oct 12, 17 Received revised SMS procedures from management company and class report.
6000966
NEW HAVEN, Connecticut
Sep 15, 16
Vessel Operational Control - Agency Action Complete
5999415
Coram, New York
Sep 14, 16
Vessel Inspection - Agency Action Complete
5156442
PHILADELPHIA, Pennsylvania
Jun 18, 15
Vessel Inspection - Approved Inspection
4846758
Port Arthur, Texas
Apr 30, 14
Vessel Inspection - Approved Inspection
4844682
Houston, Texas
Apr 27, 14
Vessel Inspection - Failure to Show
4800897
New Orleans, Louisiana
Feb 17, 14
Vessel Inspection - Administrative Action
4739625
New Orleans, Louisiana
Oct 25, 13
Vessel Inspection - Approved Inspection
4739617
New Orleans, Louisiana
Oct 24, 13
Boarding - Agency Action Complete
4622582
Miami Beach, Florida
Jun 19, 13
Vessel Inspection - Agency Action Complete
4599246
Lake Charles, Louisiana
May 23, 13
Vessel Inspection - Approved Inspection
4572407
Lake Charles, Louisiana
Apr 22, 13
Vessel Inspection - Approved Inspection
2
0
System Subsystem Cause Pollution Prevention/Response Prevention Equipment
Description Due Date Resolved Oil filtering equipment shall be of a design approved by the Administration. The Administration shall have regard to the specification recommended by the Organization. The oil content meter is not reflecting the correct date.
MARPOL 73/78 Cons 2011 / Annex I/17.6 50b May 22, 13 Yes
Resolved Date Resolution May 23, 13 MSU Lake Charles has received the Class survey for the maintance to the OWS content meter. Class has deemed the content meter is now in compliance with its factory settings.
System Subsystem Cause Deck/Cargo Inert Gas System
Description Due Date Resolved Unless the cargo tanks are gas free, the master of each tank ship shall ensure that the inert gas system is operated to maintain an inert atmosphere in the cargo tanks. As per section 39 of the quality, safety and Environmental Protection Management System Procedure Manual, cargo tanks are always kept inerted (oxygen level below 8% of volume). PSC members witnessed the oxygen content sampling of Apr 22, 13 Yes
Resolved Date Resolution Apr 22, 13 Vessel''''s crew used inert gas generator and lowered the atmosphere in the tank to below 6% oxygen by volume.
4116193
Christiansted, Virgin Islands
Aug 23, 11
Vessel Inspection - Approved Inspection
4118267
San Juan, Puerto Rico
Aug 17, 11
Boarding - Agency Action Complete
4111320
WASHINGTON, District of Columbia
Oct 28, 10
Incident Investigation - Agency Action Complete
3872150
New Orleans, Louisiana
Oct 23, 10
Vessel Inspection - Approved Inspection
2
0
System Subsystem Cause Lifesaving Lifeboat Equipment
Description Due Date Resolved 0611 - Lifeboat inventory - 5 of 27 food rations in the starboard 27 person lifeboat have lost airtight integrity as well as 4 of 27 in port 27 person lifeboat. - LSA Code 4.4.8.12 Oct 24, 10 Yes
Resolved Date Resolution Oct 25, 10 Received, reviewed and accepted class report from DNV stating the deficiency was rectified. Class provided a copy of the receipt and a photo of the replacement rations.
System Subsystem Cause Engineering Diesel Engine (propulsion-direct drive)
Description Due Date Resolved 1410 - The number 5 cylinder on the main engine is excessively leaking jacket water. - SOLAS 74am II/1-26 Oct 25, 10 Yes
Resolved Date Resolution Oct 25, 10 Received, reviewed and accepted class report from DNV stating the deficiency was rectified. Overhead casing for the number 5 cylinder was overhauled and two o-rings were replaced.
3723655
New Orleans, Louisiana
Apr 24, 10
Vessel Inspection - Administrative Action
3496660
Port Arthur, Texas
Jun 13, 09
Vessel Inspection - Approved Inspection
Documents
Issued
Expires
Agency
Certificate of Fitness - Chemical Carrier
June 3,2017
May 19,2022
RINA
Classification Document
June 25,2017
November 24,2017
RINA
International Load Line Certificate
April 18,2009
September 18,2009
DNV
International Oil Pollution Prevention Certificate
April 19,2016
September 19,2016
RINA
ISM - Document Of Compliance
December 12,2013
May 11,2014
RINA
ISM - Safety Management Certificate
April 15,2013
September 15,2013
DNV
Minimum Safe Manning Document
January 2,2012
June 22,2013
MT
SOLAS Cargo Ship Safety Construction Certificate
June 3,2017
May 19,2022
RINA
SOLAS Cargo Ship Safety Equipment Certificate
June 3,2017
May 19,2022
RINA
SOLAS Cargo Ship Safety Radio Certificate
June 3,2017
May 19,2022
RINA
Tonnage Certificate, International
July 3,2014
N/A