Navigator Saturn
Print Q88   
IMO/VIN Callsign Flag Service Year
9177569 ELYC9 LIBERIA Tank Ship 2000
Activity# Port Date Activity - Description Deficiencies
7068910 TEXAS CITY, Texas Oct 06, 20 Vessel Inspection - Approved Inspection
6675423 Houston, Texas May 10, 19 Vessel Inspection - Approved Inspection
6221737 Houston, Texas Aug 02, 17 Vessel Inspection - Approved Inspection
5800482 SOUTH PORTLAND, Maine Feb 03, 16 Boarding - Agency Action Complete
5799430 New Castle, New Hampshire Jan 30, 16 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Fire FightingFixed Pressure Water-Spraying Fire Extinguishing SystemImproper/Lack of Maintenance
DescriptionDue DateResolved
Feb 03, 16Yes
Resolved DateResolution
Feb 03, 16
5767299 Houston, Texas Nov 23, 15 Vessel Inspection - Approved Inspection
4977625 PHILADELPHIA, Pennsylvania Sep 08, 14 Facility Transfer Monitor - Agency Action Complete
4977607 PHILADELPHIA, Pennsylvania Sep 08, 14 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
LifesavingLifeboat EquipmentImproper/Lack of Maintenance
DescriptionDue DateResolved
0611- Each lifeboat shall have a food ration totaling not less than 10,000 kj for each person the lifeboat is permitted to accommodate. The lifeboat is permitted to carry 28 persons. Of the 28 food rations, 13 are not airtight. The vessel has 15 airtight food rations. 74 SOLAS (09 cons) III/ 34; LSA Code 4.4.8.12 (17ac)Yes
Resolved DateResolution
Sep 10, 14Vessel replaced the missing food rations.
SystemSubsystemCause
Deck/CargoCargo Refrigeration
DescriptionDue DateResolved
1099- An audible and visual alarm shall be provided on both sides of the airlock to indicate if more than one door is moved from the closed position. The visual alarm outside of the starboard airlock is not operational. 74 SOLAS (09 cons) VII/13.1; IGC Code 3.6.3 (10c)Sep 08, 14Yes
Resolved DateResolution
Sep 08, 14Crew were able to replace the light during the exam.
4797560 New Castle, New Hampshire Feb 22, 14 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
The gas Detection Equipment should be capable of sampling and analyzing for each sampling head location sequentially at intervals not exceeding 30 mins. when testing fixed gas system LEL and Flow alarms did not function Vessel is to manually sample all fixed sampling locations every 30 mins.Feb 22, 14Yes
Resolved DateResolution
Feb 23, 14Class Approved. Ship’s crew carried out trouble shooting the Moss Gas Detection System cabinet problem and found some sampling points flexible pipes end connections loose. The gas detecting system was satisfactorily tested again.
4797111 SOUTH PORTLAND, Maine Feb 19, 14 Boarding - Agency Action Complete
4685968 PHILADELPHIA, Pennsylvania Aug 16, 13 Vessel Inspection - Approved Inspection
4452513 PHILADELPHIA, Pennsylvania Sep 28, 12 Vessel Inspection - Agency Action Complete
4407760 PHILADELPHIA, Pennsylvania Aug 13, 12 Vessel Inspection - Approved Inspection
4404064 PHILADELPHIA, Pennsylvania Aug 10, 12 Vessel Inspection - Approved Inspection
4403193 PHILADELPHIA, Pennsylvania Aug 06, 12 Vessel Operational Control - Agency Action Complete
4333929 TEXAS CITY, Texas Jun 09, 12 Boarding - Agency Action Complete
4106678 Houston, Texas Aug 06, 11 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
DocumentationCertificates/Documents
DescriptionDue DateResolved
0199 Liquified gases not included in table 4 of 46 CFR 154 must be approved by the cmdt to be carried in bulk in US waters. Vsl ammendment to COF includes cargo mixtures that have not been approved by the cmdt. Prior to loading cargos listed on the COF amend, vsls sub-o endorsement must reflect additions. 46CFR154.30 50CSep 08, 11Yes
Resolved DateResolution
Aug 12, 11Delivered MSC updated and Signed Sub O endorsement to Vessel
4088201 Houston, Texas Jul 20, 11 Facility Transfer Monitor - Approved Inspection
3819666 Houston, Texas Aug 09, 10 Vessel Inspection - Approved Inspection
  5
SystemSubsystemCause
Construction/LoadlineStructures
DescriptionDue DateResolved
Airlock doors shaould be self closing. The airlock door closure dvice leading to teh IGG Room (stbd side) was broken. IGC Code Chpt 3.6Yes
Resolved DateResolution
Aug 09, 10Corrected on the spot.
SystemSubsystemCause
LifesavingLiferaft Equipment
DescriptionDue DateResolved
every rescue boat shall be provided with a means of bailing. The suction and discharge lines on the bailer were deteriorated beyond favorable use. LSA 5.1.1.10Aug 16, 10Yes
Resolved DateResolution
Aug 11, 10Received class survey report that stated the suction and discharge lines on the bailer have been replaced with new hoses, properly attached. Visually inspected and found to be satisfactory.
SystemSubsystemCause
ElectricalLighting (service)
DescriptionDue DateResolved
Lighting fittings should have pressurized enclosures or should be of the flameproof type. 2 light fixtures in the compressor room and 1 light fixture or deck were cracked and therefore not flameproof. IGC Code Chpt 10Yes
Resolved DateResolution
Aug 11, 10Received class survey report that the two light fixtures in the compressor room and one light fixture on the main deck have been replaced with new flameproof fixtures of original design. Visually inspected, operation tested and found to be satisfactory.
SystemSubsystemCause
LifesavingInflatable Liferafts
DescriptionDue DateResolved
Provisions shall be made for marking each life raft in such a way that the ship ID can be changed at anytime. The port side 12 man life raft id'd as 0119 on the Cert of re-inspection does not match #43873 on the life raft servicing record. LSA 4.2.7.2Yes
Resolved DateResolution
Aug 11, 10Received a class survey report stating the ID card inside the tube has been changed out by a licensed liferaft station of the manufacturer. The card now reflects the proper liferaft number. Visually inspected and found to be satisfactory.
SystemSubsystemCause
LifesavingLifeboat
DescriptionDue DateResolved
The name and port of registry of the ship shall be marked on each side of the lifeboat. The markings on the stbd side are faded and indecipherable. LSA Chpt 4.4.9.2Yes
Resolved DateResolution
Aug 11, 10Received class survey report that the lifeboats have been painted with the name and port of registry.
3817871 TEXAS CITY, Texas Aug 08, 10 Vessel Inspection - Approved Inspection
3819129 WASHINGTON, District of Columbia Aug 08, 10 Incident Investigation - Agency Action Complete
3817239 Houston, Texas Aug 07, 10 Vessel Inspection - Approved Inspection
3813595 TEXAS CITY, Texas Aug 07, 10 Boarding - Agency Action Complete
3138886 New Orleans, Louisiana Jan 30, 08 Vessel Inspection - Administrative Action
  1
SystemSubsystemCause
NavigationCollision/Grounding Avoidance
DescriptionDue DateResolved
The vessel was granted a deviation to enter The Port of New Orleans with only one of the two required independent marine radars.Jan 30, 08Yes
Resolved DateResolution
Jan 30, 08Received technicians report from Radio Holland satisfying requirement.
3134992 New Orleans, Louisiana Jan 23, 08 Vessel Operational Control - Agency Action Complete
3026650 Christiansted, Virgin Islands Aug 13, 07 Vessel Inspection - Approved Inspection
3019565 New Orleans, Louisiana Aug 06, 07 Boarding - Agency Action Complete
2907057 PHILADELPHIA, Pennsylvania Apr 13, 07 Vessel Inspection - Approved Inspection
2907193 PHILADELPHIA, Pennsylvania Apr 13, 07 Boarding - Agency Action Complete
2907179 PHILADELPHIA, Pennsylvania Apr 12, 07 Boarding - Agency Action Complete
2776596 PHILADELPHIA, Pennsylvania Sep 12, 06 Boarding - Agency Action Complete
2776210 PHILADELPHIA, Pennsylvania Sep 12, 06 Vessel Inspection - Approved Inspection
2348890 San Juan, Puerto Rico May 02, 05 Vessel Inspection - Approved Inspection
2346210 San Juan, Puerto Rico Apr 30, 05 Boarding - Agency Action Complete
2310787 Houston, Texas Feb 27, 05 Vessel Inspection - Approved Inspection
1771805 CORPUS CHRISTI, Texas Apr 11, 03 Vessel Inspection - Agency Action Complete
1768271 CORPUS CHRISTI, Texas Apr 09, 03 Vessel Inspection - Agency Action Complete
Documents Issued Expires Agency
Certificate of Compliance - Pass./Freight Vessel August 1,2017 August 1,2019 N/A
Certificate of Fitness - Gas Carrier March 14,2018 October 31,2020 DNV GL
Classification Document March 14,2018 October 31,2020 Class
International Certificate of Fitness - Gas Carrier December 21,2005 October 31,2010 N/A
International Load Line Certificate March 14,2018 October 31,2020 DNV GL
International Oil Pollution Prevention Certificate March 14,2018 October 31,2020 DNV GL
ISM - Document Of Compliance January 1,2007 March 12,2008 GL
ISM - Safety Management Certificate September 9,2011 September 8,2016 LR
Minimum Safe Manning Document October 19,2016 LR
NLS Certificate October 14,2010 October 31,2015 GL
SOLAS Cargo Ship Safety Construction Certificate March 14,2018 October 31,2020 DNV GL
SOLAS Cargo Ship Safety Equipment Certificate March 14,2018 October 31,2020 DNV GL
SOLAS Cargo Ship Safety Radio Certificate March 14,2018 October 31,2020 DNV GL
Subchapter O Endorsement September 8,2014 September 8,2016 N/A
Tonnage Certificate, International April 15,2015 DNV GL