IMO/VIN
Callsign
Flag
Service
Year
9410014
A8LQ2
LIBERIA
Tank Ship
2009
Activity#
Port
Date
Activity - Description
Deficiencies
7398215
New Orleans, Louisiana
Feb 18, 22
Vessel Inspection - Administrative Action
7396321
New Orleans, Louisiana
Feb 15, 22
Vessel Inspection - Approved Inspection
7371915
Houston, Texas
Dec 23, 21
Vessel Inspection - Approved Inspection
7316398
Houston, Texas
Sep 23, 21
Vessel Inspection - Approved Inspection
7005923
STATEN ISLAND, New York
Jul 14, 20
Vessel Inspection - Approved Inspection
7003894
STATEN ISLAND, New York
Jul 12, 20
Vessel Operational Control - Agency Action Complete
6359797
New Orleans, Louisiana
Mar 04, 18
Vessel Inspection - Approved Inspection
3
0
System Subsystem Cause Lifesaving Lifeboat
Description Due Date Resolved 0610-Lifeboats-The system shall have visual indicators to indicate the pressure of the air supply at all times. PSCO observed air leaking from O2 supply lines on both lifeboats. 74 SOLAS(14) III/31.1.6/LSA CODE 4.8 (17a) Yes
Resolved Date Resolution Mar 05, 18 5 MAR 18: Received class report from LR satisfying the requirements of the deficiency issued on 5 MAR 18.
System Subsystem Cause Construction/Loadline Markings
Description Due Date Resolved 1220-Freeboard Marks-The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. PSCO observed load line markings on both sides of the ship have all of the paint rubbed off and barely visible. LOAD LINES Reg. 8 (16a) Mar 18, 18 Yes
Resolved Date Resolution Mar 05, 18 5 MAR 18: Received class report from LR satisfying the requirements of the deficiency issued on 5 MAR 18.
System Subsystem Cause Documentation Manuals/Policy Documentation
Description Due Date Resolved 1840-Instrumentaion-Detailed instruction manuals shall be provided on board, covering the operations, safety and maintenance requirements and occupational health hazards relevant to the inert gas system. PSCO observed that the vessel does not have the correct manuals to calibrate IGS oxygen meter. 74 SOLAS(14) II-2/4.5.5.1.2/FSS CODE 15.2.4.4 ( Mar 18, 18 Yes
Resolved Date Resolution Mar 05, 18 5 MAR 18: Received class report from LR satisfying the requirements of the deficiency issued on 5 MAR 18.
4680239
STATEN ISLAND, New York
Aug 09, 13
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Deck/Cargo Inert Gas System
Description Due Date Resolved LCD monitor was not working properly. The LCD monitor controls the IGS and maintains the oxygen content. Yes
Resolved Date Resolution Aug 11, 13 Received class report from Lloyds Register (Certificate # NYK1300220) stating that the LCD monitor was replaced and that all IGS settings were adjusted and verified before operation.
4677607
STATEN ISLAND, New York
Aug 08, 13
Boarding - Agency Action Complete
4567254
Houston, Texas
Apr 11, 13
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Navigation Collision/Grounding Avoidance
Description Due Date Resolved Each vessel of 10,000 gross tons or more must have in addition to the primary radar system, a second marine radar system that operates independently of the first. Vessels secondary marine radar was reported to be inop. Vessel submitted an inbound LOD request. Yes
Resolved Date Resolution Apr 15, 13 Vessel submitted tech report attesting to the proper repair and operation of the secondary marine radar system.
4551728
San Juan, Puerto Rico
Mar 19, 13
Vessel Inspection - Approved Inspection
4418096
STATEN ISLAND, New York
Aug 21, 12
Vessel Transfer Monitor - Agency Action Complete
4251580
San Juan, Puerto Rico
Feb 27, 12
Vessel Inspection - Approved Inspection
4248252
San Juan, Puerto Rico
Feb 24, 12
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Pollution Prevention/Response Prevention Equipment
Description Due Date Resolved Any ship of 10000 gross tons and above shall be fitted with an oily water seperator complying with paragraph 7 of this regulation. Oily water seperator sensor desiccator was faulty and required replacement. Provide class report once unit is operational. MARPOL Annex I Regulation 14 Yes
Resolved Date Resolution Feb 25, 12 Vessel provided a class report for the renewed OWS oil content meter faulty sensor. Statement indicates that the OWS equipment is in good working condition.
3937262
North Charleston, South Carolina
Feb 01, 11
Vessel Transfer Monitor - Approved Inspection
3729782
STATEN ISLAND, New York
May 03, 10
Vessel Inspection - Approved Inspection
3729588
STATEN ISLAND, New York
May 03, 10
Vessel Inspection - Approved Inspection
3726187
STATEN ISLAND, New York
Apr 28, 10
Boarding - Agency Action Complete
Documents
Issued
Expires
Agency
Certificate of Compliance - Tank Vessel
February 24,2012
February 24,2014
USCG
Certificate of Fitness - Chemical Carrier
July 5,2019
April 9,2024
LR
Classification Document
March 28,2014
April 9,2019
LR
COC-TVE Renewal
July 14,2020
July 14,2022
N/A
International Certificate of Fitness - Chemical
March 24,2010
August 23,2010
N/A
International Load Line Certificate
July 5,2019
April 9,2024
LR
International Oil Pollution Prevention Certificate
March 1,2016
April 9,2019
LR
ISM - Document Of Compliance
September 4,2013
September 11,2018
LR
ISM - Safety Management Certificate
September 2,2019
October 29,2020
LR
Minimum Safe Manning Document
April 10,2009
N/A
SOLAS Cargo Ship Safety Construction Certificate
July 5,2019
April 9,2024
LR
SOLAS Cargo Ship Safety Equipment Certificate
July 5,2019
April 9,2024
LR
SOLAS Cargo Ship Safety Radio Certificate
March 28,2014
April 9,2019
LR
Tonnage Certificate, International
November 17,2009
GL