IMO/VIN
Callsign
Flag
Service
Year
1196474
WENM
UNITED STATES
Tank Barge
2008
Activity#
Port
Date
Activity - Description
Deficiencies
7122611
Morgan City, Louisiana
Jan 11, 21
Vessel Inspection - Approved Inspection
6977503
STATEN ISLAND, New York
Jun 15, 20
Vessel Inspection - Agency Action Complete
6944524
WASHINGTON, District of Columbia
Apr 27, 20
Vessel Inspection - Agency Action Complete
6896654
PHILADELPHIA, Pennsylvania
Jan 27, 20
Vessel Inspection - Approved Inspection
6594703
STATEN ISLAND, New York
Dec 10, 18
Vessel Inspection - Agency Action Complete
6557257
PHILADELPHIA, Pennsylvania
Oct 03, 18
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause 99 - Other N/A - No Subsystem Damaged By Earlier Event
Description Due Date Resolved Vessel lost anchor during operation in the Mantua Creek area. Provide documentation to prove the vessel is able to meet the required emergency control systems required under 33 CFR 155.230(b). Oct 09, 18 Yes
Resolved Date Resolution Oct 09, 18 Recieved class report(attached).
6394194
STATEN ISLAND, New York
Apr 16, 18
Vessel Inspection - Agency Action Complete
6068847
STATEN ISLAND, New York
Jan 11, 17
Vessel Inspection - Approved Inspection
5917651
BOSTON, Massachusetts
Jun 24, 16
Vessel Transfer Monitor - Approved Inspection
5800414
Houma, Louisiana
Jan 20, 16
Vessel Inspection - Approved Inspection
5799765
Houma, Louisiana
Jan 12, 16
Vessel Inspection - Approved Inspection
5085572
Houma, Louisiana
Mar 20, 15
Vessel Inspection - Approved Inspection
4838815
Houma, Louisiana
Apr 21, 14
Vessel Inspection - Approved Inspection
2
0
System Subsystem Cause Electrical Electric Supply System (service) Improper/Lack of Maintenance
Description Due Date Resolved #3 genset could not be adjusted to test the reverse power relay. Yes
Resolved Date Resolution Apr 25, 14 Vsl found that they had installed the wrong type of frequency adjust knob. ABS attended vsl and tested the reverse power relay. Tested satisfactory.
System Subsystem Cause Electrical Electric Generation Source (service) Improper/Lack of Maintenance
Description Due Date Resolved Vsls #2 genset was torn apart and not operable during inspection. Workers were currently onboard working on genset. Yes
Resolved Date Resolution Apr 21, 14 Prior to MI departure, vsl rep stated that the #2 genset was back together and back on line. Tested #2 genset on line with load, in parallel, and reverse power relay. Tested satisfactory.
4739751
Houston, Texas
Oct 23, 13
Vessel Inspection - Approved Inspection
4532609
Morgan City, Louisiana
Feb 13, 13
Vessel Inspection - Approved Inspection
4
0
System Subsystem Cause Electrical Electrical Distribution System (service) Improper Installation
Description Due Date Resolved (07) drip shields required for all CB panels. Apr 01, 13 Yes
Resolved Date Resolution Mar 02, 13 All CB panels now have drip shields installed.
System Subsystem Cause Lifesaving Inflatable Liferafts Improper Installation
Description Due Date Resolved Liferaft was installed improperly. Found on top of the berthing accomodations. Determined that carrying the liferaft down the ladder was an unacceptable comliance to the easy side to transfer requirement. Vsl can either relocate liferaft or install second liferaft in opposite side of vessel. Yes
Resolved Date Resolution Mar 02, 13 Vessel installed life raft amidships, behind the machinery space on a previously installed bracket. All components and markings were correct to the satisfaction of attending marine inspector.
System Subsystem Cause Lifesaving Lifebuoys Placed in Improper Service
Description Due Date Resolved Vessel was found to have only (04) life buoys in service. Due to length of vessel, (10) life buoys are required. Yes
Resolved Date Resolution Mar 02, 13 Vessel is now in compliance with (10) required life buoys in the proper configuration.
System Subsystem Cause Documentation Logs/Records Improper/Lack of Maintenance
Description Due Date Resolved Waste management plan not present during inspection. Apr 01, 13 Yes
Resolved Date Resolution Mar 02, 13 Vessel provided waste management plan.
4306544
San Juan, Puerto Rico
May 09, 12
Vessel Inspection - Approved Inspection
4300499
San Juan, Puerto Rico
May 01, 12
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Pollution Prevention/Response Prevention Equipment
Description Due Date Resolved Repair or replace sewage treatment tank in stbd aft rake. May 18, 12 Yes
Resolved Date Resolution May 09, 12
3988799
San Juan, Puerto Rico
Apr 18, 11
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Documentation Safety/Response Plans/Programs
Description Due Date Resolved Submit fire & lifesaving plan for approval to Sector San Juan inspection office to include new location of life raft. May 18, 11 Yes
Resolved Date Resolution Jun 23, 11
3944820
San Juan, Puerto Rico
Feb 10, 11
Vessel Inspection - Approved Inspection
3747074
New Orleans, Louisiana
May 14, 10
Vessel Inspection - Approved Inspection
3800144
San Juan, Puerto Rico
Apr 28, 10
Vessel Inspection - Approved Inspection
5
0
System Subsystem Cause Deck/Cargo Vapor Control Systems Improper Installation
Description Due Date Resolved Properly mark vapor control line IAW 33 CFR Sub O May 28, 10 Yes
Resolved Date Resolution May 28, 10 Properly marked vapor control line IAW 33 Sub O
System Subsystem Cause Engineering Generator (propulsion/auxiliary-electric)
Description Due Date Resolved Prove proper operation of generator prime mover over speed and low lube oil shut down. May 28, 10 Yes
Resolved Date Resolution May 28, 10 Proved proper operation of generator prime mover over speed and low lube oil shut down.
System Subsystem Cause Engineering Generator (propulsion-electric)
Description Due Date Resolved Prove proper operation of reverse power relay of ship service generator. May 28, 10 Yes
Resolved Date Resolution May 28, 10 Proved proper operation of reverse power relay of ship service generator.
System Subsystem Cause Operations/Management Drug and Alcohol Testing
Description Due Date Resolved Provide list of covered employees enrolled in random drug testing program May 28, 10 Yes
Resolved Date Resolution May 28, 10 Provided list of covered employees enrolled in random drug testing program
System Subsystem Cause Construction/Loadline Hull
Description Due Date Resolved Provide repair proposal for sharp inset on STBD stern. May 28, 10 Yes
Resolved Date Resolution May 28, 10 Provided repair proposal for sharp inset on STBD stern.
3576498
STATEN ISLAND, New York
Aug 25, 09
Vessel Inspection - Agency Action Complete
3550780
STATEN ISLAND, New York
Apr 28, 09
Vessel Inspection - Agency Action Complete
1
0
System Subsystem Cause Documentation Certificates/Documents
Description Due Date Resolved Vessel was issue an IAPP certificate from MSU Morgan City but is un familiar with the regulations and procedures associated with it. Crew is to become familiar with MARPOL Annex VI regs, equipment and operations as per CG-543 policy letter 09-01. Apr 28, 09 Yes
Resolved Date Resolution Jul 07, 09 Attended vessel and observed compliance to MARPOL Annex VI regulations.
3432473
NEW HAVEN, Connecticut
Mar 12, 09
Vessel Transfer Monitor - Agency Action Complete
3317095
Baltimore, Maryland
Sep 03, 08
Vessel Transfer Monitor - Agency Action Complete
3141462
Morgan City, Louisiana
Feb 04, 08
Vessel Inspection - Approved Inspection
Documents
Issued
Expires
Agency
Cargo Authority Attachment
June 4,2020
N/A
CERTIFICATE OF DOCUMENTATION
February 4,2021
February 28,2022
USCG
Certificate of Inspection
March 1,2013
March 1,2018
N/A
Certificate of Inspection - Amended
March 1,2013
March 1,2018
N/A
Classification Document
February 11,2014
February 10,2018
N/A
International Load Line Certificate
January 26,2016
January 25,2021
ABS
International Oil Pollution Prevention Certificate
January 22,2016
January 22,2021
N/A
NLS Certificate
January 22,2021
January 22,2026
N/A
Stability Letter
January 23,2008
ABS
Tonnage Certificate, U.S.
January 24,2008
ABS