Gm 6508
Print Q88   
IMO/VIN Callsign Flag Service Year
1196474 WENM UNITED STATES Tank Barge 2008
Activity# Port Date Activity - Description Deficiencies
7122611 Morgan City, Louisiana Jan 11, 21 Vessel Inspection - Approved Inspection
6977503 STATEN ISLAND, New York Jun 15, 20 Vessel Inspection - Agency Action Complete
6944524 WASHINGTON, District of Columbia Apr 27, 20 Vessel Inspection - Agency Action Complete
6896654 PHILADELPHIA, Pennsylvania Jan 27, 20 Vessel Inspection - Approved Inspection
6594703 STATEN ISLAND, New York Dec 10, 18 Vessel Inspection - Agency Action Complete
6557257 PHILADELPHIA, Pennsylvania Oct 03, 18 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
99 - OtherN/A - No SubsystemDamaged By Earlier Event
DescriptionDue DateResolved
Vessel lost anchor during operation in the Mantua Creek area. Provide documentation to prove the vessel is able to meet the required emergency control systems required under 33 CFR 155.230(b).Oct 09, 18Yes
Resolved DateResolution
Oct 09, 18Recieved class report(attached).
6394194 STATEN ISLAND, New York Apr 16, 18 Vessel Inspection - Agency Action Complete
6068847 STATEN ISLAND, New York Jan 11, 17 Vessel Inspection - Approved Inspection
5917651 BOSTON, Massachusetts Jun 24, 16 Vessel Transfer Monitor - Approved Inspection
5800414 Houma, Louisiana Jan 20, 16 Vessel Inspection - Approved Inspection
5799765 Houma, Louisiana Jan 12, 16 Vessel Inspection - Approved Inspection
5085572 Houma, Louisiana Mar 20, 15 Vessel Inspection - Approved Inspection
4838815 Houma, Louisiana Apr 21, 14 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
ElectricalElectric Supply System (service)Improper/Lack of Maintenance
DescriptionDue DateResolved
#3 genset could not be adjusted to test the reverse power relay.Yes
Resolved DateResolution
Apr 25, 14Vsl found that they had installed the wrong type of frequency adjust knob. ABS attended vsl and tested the reverse power relay. Tested satisfactory.
SystemSubsystemCause
ElectricalElectric Generation Source (service)Improper/Lack of Maintenance
DescriptionDue DateResolved
Vsls #2 genset was torn apart and not operable during inspection. Workers were currently onboard working on genset.Yes
Resolved DateResolution
Apr 21, 14Prior to MI departure, vsl rep stated that the #2 genset was back together and back on line. Tested #2 genset on line with load, in parallel, and reverse power relay. Tested satisfactory.
4739751 Houston, Texas Oct 23, 13 Vessel Inspection - Approved Inspection
4532609 Morgan City, Louisiana Feb 13, 13 Vessel Inspection - Approved Inspection
  4
SystemSubsystemCause
ElectricalElectrical Distribution System (service)Improper Installation
DescriptionDue DateResolved
(07) drip shields required for all CB panels.Apr 01, 13Yes
Resolved DateResolution
Mar 02, 13All CB panels now have drip shields installed.
SystemSubsystemCause
LifesavingInflatable LiferaftsImproper Installation
DescriptionDue DateResolved
Liferaft was installed improperly. Found on top of the berthing accomodations. Determined that carrying the liferaft down the ladder was an unacceptable comliance to the easy side to transfer requirement. Vsl can either relocate liferaft or install second liferaft in opposite side of vessel.Yes
Resolved DateResolution
Mar 02, 13Vessel installed life raft amidships, behind the machinery space on a previously installed bracket. All components and markings were correct to the satisfaction of attending marine inspector.
SystemSubsystemCause
LifesavingLifebuoysPlaced in Improper Service
DescriptionDue DateResolved
Vessel was found to have only (04) life buoys in service. Due to length of vessel, (10) life buoys are required.Yes
Resolved DateResolution
Mar 02, 13Vessel is now in compliance with (10) required life buoys in the proper configuration.
SystemSubsystemCause
DocumentationLogs/RecordsImproper/Lack of Maintenance
DescriptionDue DateResolved
Waste management plan not present during inspection.Apr 01, 13Yes
Resolved DateResolution
Mar 02, 13Vessel provided waste management plan.
4306544 San Juan, Puerto Rico May 09, 12 Vessel Inspection - Approved Inspection
4300499 San Juan, Puerto Rico May 01, 12 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
Repair or replace sewage treatment tank in stbd aft rake.May 18, 12Yes
Resolved DateResolution
May 09, 12
3988799 San Juan, Puerto Rico Apr 18, 11 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
DocumentationSafety/Response Plans/Programs
DescriptionDue DateResolved
Submit fire & lifesaving plan for approval to Sector San Juan inspection office to include new location of life raft.May 18, 11Yes
Resolved DateResolution
Jun 23, 11
3944820 San Juan, Puerto Rico Feb 10, 11 Vessel Inspection - Approved Inspection
3747074 New Orleans, Louisiana May 14, 10 Vessel Inspection - Approved Inspection
3800144 San Juan, Puerto Rico Apr 28, 10 Vessel Inspection - Approved Inspection
  5
SystemSubsystemCause
Deck/CargoVapor Control SystemsImproper Installation
DescriptionDue DateResolved
Properly mark vapor control line IAW 33 CFR Sub OMay 28, 10Yes
Resolved DateResolution
May 28, 10Properly marked vapor control line IAW 33 Sub O
SystemSubsystemCause
EngineeringGenerator (propulsion/auxiliary-electric)
DescriptionDue DateResolved
Prove proper operation of generator prime mover over speed and low lube oil shut down.May 28, 10Yes
Resolved DateResolution
May 28, 10Proved proper operation of generator prime mover over speed and low lube oil shut down.
SystemSubsystemCause
EngineeringGenerator (propulsion-electric)
DescriptionDue DateResolved
Prove proper operation of reverse power relay of ship service generator.May 28, 10Yes
Resolved DateResolution
May 28, 10Proved proper operation of reverse power relay of ship service generator.
SystemSubsystemCause
Operations/ManagementDrug and Alcohol Testing
DescriptionDue DateResolved
Provide list of covered employees enrolled in random drug testing programMay 28, 10Yes
Resolved DateResolution
May 28, 10Provided list of covered employees enrolled in random drug testing program
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
Provide repair proposal for sharp inset on STBD stern.May 28, 10Yes
Resolved DateResolution
May 28, 10Provided repair proposal for sharp inset on STBD stern.
3576498 STATEN ISLAND, New York Aug 25, 09 Vessel Inspection - Agency Action Complete
3550780 STATEN ISLAND, New York Apr 28, 09 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
DocumentationCertificates/Documents
DescriptionDue DateResolved
Vessel was issue an IAPP certificate from MSU Morgan City but is un familiar with the regulations and procedures associated with it. Crew is to become familiar with MARPOL Annex VI regs, equipment and operations as per CG-543 policy letter 09-01.Apr 28, 09Yes
Resolved DateResolution
Jul 07, 09Attended vessel and observed compliance to MARPOL Annex VI regulations.
3432473 NEW HAVEN, Connecticut Mar 12, 09 Vessel Transfer Monitor - Agency Action Complete
3317095 Baltimore, Maryland Sep 03, 08 Vessel Transfer Monitor - Agency Action Complete
3141462 Morgan City, Louisiana Feb 04, 08 Vessel Inspection - Approved Inspection
Documents Issued Expires Agency
Cargo Authority Attachment June 4,2020 N/A
CERTIFICATE OF DOCUMENTATION February 4,2021 February 28,2022 USCG
Certificate of Inspection March 1,2013 March 1,2018 N/A
Certificate of Inspection - Amended March 1,2013 March 1,2018 N/A
Classification Document February 11,2014 February 10,2018 N/A
International Load Line Certificate January 26,2016 January 25,2021 ABS
International Oil Pollution Prevention Certificate January 22,2016 January 22,2021 N/A
NLS Certificate January 22,2021 January 22,2026 N/A
Stability Letter January 23,2008 ABS
Tonnage Certificate, U.S. January 24,2008 ABS