IMO/VIN
Callsign
Flag
Service
Year
9340477
DYPZ
PHILIPPINES
Tank Ship
2007
Activity#
Port
Date
Activity - Description
Deficiencies
6963716
Portsmouth, Virginia
Jun 01, 20
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause 06 - Cargo Operations Including Equipment N/A - No Subsystem Placed in Improper Service
Description Due Date Resolved 06106 - Cargo Operations Including Equipment - Each hose must be marked with "OIL SERVICE" or "HAZMAT SERVICE-SEE LIST" and the MAWP. Date of Manufacturer and date of latest test can either be marked on the hose or in a log book. Flex hoses amidship were not marked properly. 33CFR155.800 / 33CFR154.500(e) & (f) - 50ac Jul 02, 20 Yes
Resolved Date Resolution Jun 05, 20 Received satisfactory class survey report, attesting to rectification of hose markings.
4844702
Houston, Texas
Apr 27, 14
Vessel Inspection - Approved Inspection
4823469
San Pedro, California
Apr 05, 14
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Deck/Cargo Vapor Control Systems
Description Due Date Resolved 1899 - Each Vessel vapor connection flange face must have a permanent stud projecting outward that has a .5 in diameter and is at lease 1 in. long. There are 4 vapor flanges on the port side missing the 1 in. stud. 40ac Yes
Resolved Date Resolution Apr 27, 14 Received, reviewed and accepted class report from BV attesting to the installation of vapor studs as required.
4033510
Savannah, Georgia
Jun 08, 11
Vessel Inspection - Agency Action Complete
3943349
Baltimore, Maryland
Feb 11, 11
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Deck/Cargo Cargo Heating
Description Due Date Resolved Steam Supply lines used for heating cargo have leaks at the following location; at number 3 starboard cargo tank; at number 4 starboard cargo tank; and number 7 cargo tank. Yes
Resolved Date Resolution Feb 21, 11 Received Class report attesting to proper repairs
3427439
STATEN ISLAND, New York
Mar 05, 09
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Deck/Cargo Cargo Heating
Description Due Date Resolved Make permanent repairs to the main steam supply line on deck that is wasted and leaking in the following three (03) places: Amidships of 3p/3s cargo tanks, 2s/2p cargo tanks, and IWO 6-person liferaft forward. Make permanent repairs prior to next US port after sailing foreign to the satisfaction of Class. Yes
Resolved Date Resolution Feb 11, 11 Cleared onscene by inspection dated 11FEB11
3426407
STATEN ISLAND, New York
Mar 05, 09
Boarding - Approved Inspection
3122279
New Orleans, Louisiana
Dec 29, 07
Vessel Inspection - Administrative Action
3083072
PHILADELPHIA, Pennsylvania
Oct 19, 07
Vessel Inspection - Approved Inspection
Documents
Issued
Expires
Agency
Certificate of Compliance - Pass./Freight Vessel
October 19,2007
October 19,2009
N/A
Certificate of Compliance - Tank Vessel
April 5,2014
April 5,2016
N/A
Certificate of Fitness - Chemical Carrier
July 7,2012
May 31,2017
BV
Certificate of Fitness - Gas Carrier
January 13,2011
September 30,2012
BV
Classification Document
July 7,2012
May 31,2017
BV
International Load Line Certificate
July 7,2012
May 31,2017
BV
International Oil Pollution Prevention Certificate
October 10,2013
May 31,2017
BV
ISM - Document Of Compliance
March 2,2012
March 10,2017
BV
ISM - Safety Management Certificate
July 22,2017
September 30,2022
BV
Minimum Safe Manning Document
July 10,2012
July 5,2017
PH
SOLAS Cargo Ship Safety Construction Certificate
March 21,2017
May 31,2022
BV
SOLAS Cargo Ship Safety Equipment Certificate
May 21,2017
May 31,2022
BV
SOLAS Cargo Ship Safety Radio Certificate
July 7,2012
May 31,2017
BV
Tonnage Certificate, International
July 4,2012
BV