Octaden
Print Q88   
IMO/VIN Callsign Flag Service Year
9340477 DYPZ PHILIPPINES Tank Ship 2007
Activity# Port Date Activity - Description Deficiencies
6963716 Portsmouth, Virginia Jun 01, 20 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No SubsystemPlaced in Improper Service
DescriptionDue DateResolved
06106 - Cargo Operations Including Equipment - Each hose must be marked with "OIL SERVICE" or "HAZMAT SERVICE-SEE LIST" and the MAWP. Date of Manufacturer and date of latest test can either be marked on the hose or in a log book. Flex hoses amidship were not marked properly. 33CFR155.800 / 33CFR154.500(e) & (f) - 50acJul 02, 20Yes
Resolved DateResolution
Jun 05, 20Received satisfactory class survey report, attesting to rectification of hose markings.
4844702 Houston, Texas Apr 27, 14 Vessel Inspection - Approved Inspection
4823469 San Pedro, California Apr 05, 14 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Deck/CargoVapor Control Systems
DescriptionDue DateResolved
1899 - Each Vessel vapor connection flange face must have a permanent stud projecting outward that has a .5 in diameter and is at lease 1 in. long. There are 4 vapor flanges on the port side missing the 1 in. stud. 40acYes
Resolved DateResolution
Apr 27, 14Received, reviewed and accepted class report from BV attesting to the installation of vapor studs as required.
4033510 Savannah, Georgia Jun 08, 11 Vessel Inspection - Agency Action Complete
3943349 Baltimore, Maryland Feb 11, 11 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Deck/CargoCargo Heating
DescriptionDue DateResolved
Steam Supply lines used for heating cargo have leaks at the following location; at number 3 starboard cargo tank; at number 4 starboard cargo tank; and number 7 cargo tank.Yes
Resolved DateResolution
Feb 21, 11Received Class report attesting to proper repairs
3427439 STATEN ISLAND, New York Mar 05, 09 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Deck/CargoCargo Heating
DescriptionDue DateResolved
Make permanent repairs to the main steam supply line on deck that is wasted and leaking in the following three (03) places: Amidships of 3p/3s cargo tanks, 2s/2p cargo tanks, and IWO 6-person liferaft forward. Make permanent repairs prior to next US port after sailing foreign to the satisfaction of Class.Yes
Resolved DateResolution
Feb 11, 11Cleared onscene by inspection dated 11FEB11
3426407 STATEN ISLAND, New York Mar 05, 09 Boarding - Approved Inspection
3122279 New Orleans, Louisiana Dec 29, 07 Vessel Inspection - Administrative Action
3083072 PHILADELPHIA, Pennsylvania Oct 19, 07 Vessel Inspection - Approved Inspection
Documents Issued Expires Agency
Certificate of Compliance - Pass./Freight Vessel October 19,2007 October 19,2009 N/A
Certificate of Compliance - Tank Vessel April 5,2014 April 5,2016 N/A
Certificate of Fitness - Chemical Carrier July 7,2012 May 31,2017 BV
Certificate of Fitness - Gas Carrier January 13,2011 September 30,2012 BV
Classification Document July 7,2012 May 31,2017 BV
International Load Line Certificate July 7,2012 May 31,2017 BV
International Oil Pollution Prevention Certificate October 10,2013 May 31,2017 BV
ISM - Document Of Compliance March 2,2012 March 10,2017 BV
ISM - Safety Management Certificate July 22,2017 September 30,2022 BV
Minimum Safe Manning Document July 10,2012 July 5,2017 PH
SOLAS Cargo Ship Safety Construction Certificate March 21,2017 May 31,2022 BV
SOLAS Cargo Ship Safety Equipment Certificate May 21,2017 May 31,2022 BV
SOLAS Cargo Ship Safety Radio Certificate July 7,2012 May 31,2017 BV
Tonnage Certificate, International July 4,2012 BV