IMO/VIN
Callsign
Flag
Service
Year
1147851
UNITED STATES
Tank Barge
2003
Activity#
Port
Date
Activity - Description
Deficiencies
7367099
San Francisco, California
Dec 13, 21
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause 06 - Cargo Operations Including Equipment N/A - No Subsystem Improper/Lack of Maintenance
Description Due Date Resolved Periodic inspection. Your vessel must undergo a periodic inspection within 3 months before or after the second or third anniversary of the date of your vessel's COI. The scope of the periodic inspection is the same as that for the inspection for certification as specified in 31.10-15(b). The inspection for certification shall include an inspection of machinery and equipment. Both prime movers were not in a condition to witness operational tests and shutdowns. Dec 13, 21 Yes
Resolved Date Resolution Dec 20, 21 Operational tests and shutdowns of prime movers inspected satisfactorily.
7346238
San Francisco, California
Nov 06, 21
Vessel Inspection - Approved Inspection
7186321
San Francisco, California
Aug 24, 21
Vessel Inspection - Approved Inspection
7096542
San Francisco, California
Nov 16, 20
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause 13 - Propulsion and Auxiliary Machinery N/A - No Subsystem Improper/Lack of Maintenance
Description Due Date Resolved All tank vessels are subject to the regulatoins in parts 50 to 63 of Subchapter F. Exhaust manifold heat shielding missing on port and stbd cargo pump engine.
31.30-1
56.95(b) Dec 17, 20 Yes
Resolved Date Resolution Feb 26, 21 Photos submitted 18 NOV 2020.
6890383
San Francisco, California
Jan 17, 20
Vessel Inspection - Approved Inspection
6588608
San Francisco, California
Nov 27, 18
Vessel Inspection - Approved Inspection
3
0
System Subsystem Cause 06 - Cargo Operations Including Equipment N/A - No Subsystem Improper/Lack of Maintenance
Description Due Date Resolved Cargo tanks in which Grade A, B, or C liquids are to be transported shall be fitted with either individual pessure-vacuum relief valves or shall be fitted with a venting system consisting of branch vent lines. Inboard P/V relief valve was seized on the vacuum side. Ensure proper operation of P/V relief valve. Nov 26, 18 Yes
Resolved Date Resolution Nov 26, 18
System Subsystem Cause 13 - Propulsion and Auxiliary Machinery N/A - No Subsystem Improper Installation
Description Due Date Resolved Each ungrounded system must be provided with a suitably sensitive ground detection system located at the respective switchboard which provides continuous indication of circuit status to ground with a provision to momentarily remove the indicating device from the reference ground. The ground fault indicating lamps were burnt out. Dec 26, 18 Yes
Resolved Date Resolution Dec 18, 18 New bulbs were installed.
System Subsystem Cause 13 - Propulsion and Auxiliary Machinery N/A - No Subsystem Improper Installation
Description Due Date Resolved There must be ground detection for each power system that is isolated from the ship's service power by transformers. Vessel does not have ground detection at the transformer. Dec 26, 18 Yes
Resolved Date Resolution Sep 24, 19 Ground detection installed.
6567191
San Francisco, California
Oct 24, 18
Vessel Inspection - Approved Inspection
6518282
San Francisco, California
Aug 20, 18
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause 02 - Structural Conditions N/A - No Subsystem
Description Due Date Resolved Conduct permanent repairs to pinhole weld leak in #4P fwd, centerline blkhd during next drydock. Oct 31, 18 Yes
Resolved Date Resolution Jan 16, 20 Vessel representative provided maintenance evidence of repair completion.
6406103
WASHINGTON, District of Columbia
Apr 15, 18
Incident Investigation - Agency Action Complete
6322490
San Francisco, California
Nov 16, 17
Vessel Inspection - Approved Inspection
6030877
San Francisco, California
Oct 26, 16
Vessel Inspection - Approved Inspection
5778325
San Francisco, California
Dec 09, 15
Vessel Inspection - Approved Inspection
5039623
San Francisco, California
Dec 15, 14
Vessel Inspection - Approved Inspection
4960817
San Francisco, California
Aug 07, 14
Vessel Inspection - Approved Inspection
4727947
San Francisco, California
Oct 02, 13
Vessel Inspection - Approved Inspection
4466407
San Francisco, California
Oct 17, 12
Vessel Inspection - Approved Inspection
4335797
San Francisco, California
Jun 06, 12
Vessel Transfer Monitor - Approved Inspection
4286076
San Francisco, California
Apr 12, 12
Vessel Transfer Monitor - Approved Inspection
4267299
San Francisco, California
Mar 19, 12
Enforcement - Agency Action Complete
4227353
San Francisco, California
Jan 13, 12
Vessel Inspection - Approved Inspection
4214995
San Francisco, California
Dec 27, 11
Vessel Inspection - Approved Inspection
4
0
System Subsystem Cause Construction/Loadline Hull
Description Due Date Resolved Make permanent repairs to the portside bow rake prior to cargo operations. Yes
Resolved Date Resolution Jan 12, 12 Crop and renew hull plating IWO damage areas marked out by CG inspectors and ABS rep. Crop and renew all bottom longitudinals and deep web framing IWO of damaged areas marked out by CG inspectors and ABS rep. All repairs were made and 835 cleared.
System Subsystem Cause Construction/Loadline Hull
Description Due Date Resolved Provide a repair plan for the damaged section of the portside bow rake. Yes
Resolved Date Resolution Jan 12, 12 Received details from shipyard for repairs made.
System Subsystem Cause Deck/Cargo Holds/Tanks
Description Due Date Resolved Provide access to port wing tanks as necessary to survey the damage. Yes
Resolved Date Resolution Dec 29, 11 The port # 1 wing tank was thoroughly inspected and no other damage was apparent.
System Subsystem Cause Deck/Cargo Cargo Transfer/Lightering (liquid)
Description Due Date Resolved Vessel is granted a onetime cargo operation prior to making repairs, to offload any remaining cargo onboard. Yes
Resolved Date Resolution Jan 12, 12
4253652
WASHINGTON, District of Columbia
Dec 26, 11
Incident Investigation - Agency Action Complete
4142932
San Francisco, California
Sep 14, 11
Vessel Inspection - Approved Inspection
2
0
System Subsystem Cause Deck/Cargo Cargo Stowage
Description Due Date Resolved Issued CG-835:
Identify source of cargo leaks found in the #4 double bottom, on the fwd bulkhead, and fractured weld next to ladder on cargo tank wall, IAW 46 CFR 31.10-21(c). Yes
Resolved Date Resolution Sep 17, 11 ALOT of back gouging and re-welding on either side of suspected weld fractures. Pressed up wing voids (soap solution), air lance and finally dye penetrate. No leaks from any site. (ABS - class present during the whole evolution).
System Subsystem Cause Deck/Cargo Holds/Tanks
Description Due Date Resolved Issued CG-835:
Make proper repairs to leaking hydraulic line from day tank (hose clamps). Oct 14, 11 Yes
Resolved Date Resolution Sep 17, 11 Replaced hose and clamps.
4017074
San Francisco, California
May 17, 11
Vessel Inspection - Approved Inspection
4017189
WASHINGTON, District of Columbia
May 11, 11
Incident Investigation - Agency Action Complete
4078318
San Francisco, California
May 03, 11
Vessel Inspection - Approved Inspection
3960833
ALAMEDA, California
Feb 18, 11
Vessel Inspection - Approved Inspection
3908498
San Francisco, California
Dec 10, 10
Vessel Transfer Monitor - Agency Action Complete
3865339
San Francisco, California
Oct 26, 10
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Documentation Certificates/Documents
Description Due Date Resolved Provide on board the stability letter dated 11 March 2004. Oct 26, 10 Yes
Resolved Date Resolution Oct 26, 10
3680510
San Francisco, California
Feb 10, 10
Vessel Transfer Monitor - Agency Action Complete
3684688
WASHINGTON, District of Columbia
Jan 25, 10
Incident Investigation - Agency Action Complete
3612294
San Francisco, California
Oct 13, 09
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Engineering Pressure Vessel
Description Due Date Resolved Demonstrate successful hydrostatic test of pressure vessel (compressed air cylinder) located in the machinery room in accordance with 46CFR61.10-5(d). Nov 11, 09 Yes
Resolved Date Resolution Nov 09, 09 The owner/operator elected to remove the PV from the vessel and not replace it.
3355199
San Francisco, California
Oct 31, 08
Enforcement - Payment Received
3350066
WASHINGTON, District of Columbia
Oct 21, 08
Incident Investigation - Agency Action Complete
3338124
San Francisco, California
Oct 14, 08
Vessel Inspection - Approved Inspection
3089322
San Francisco, California
Oct 29, 07
Vessel Inspection - Approved Inspection
2815611
WASHINGTON, District of Columbia
Nov 06, 06
Incident Investigation - Agency Action Complete
2776245
San Francisco, California
Sep 12, 06
Vessel Inspection - Approved Inspection
2659053
San Francisco, California
May 25, 06
Enforcement - Agency Action Complete
2648557
San Francisco, California
May 13, 06
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Construction/Loadline Hull
Description Due Date Resolved Make #5 starboard void available for inspection by a Coast Guard Marine Inspector prior to conducting cargo operations with the barge. May 31, 06 Yes
Resolved Date Resolution May 19, 06
2650084
WASHINGTON, District of Columbia
May 13, 06
Incident Investigation - Agency Action Complete
2563407
San Francisco, California
Jan 11, 06
Vessel Inspection - Approved Inspection
2
0
System Subsystem Cause Fire Fighting Semiportable Chemical-Foam Fire Extinguishers
Description Due Date Resolved Provide one B-V semi-portable extinguisher in the cargo area IAW 46 CFR Table 34.10(a). This requirement must be completed prior to transiting with persons onboard. Feb 11, 06 Yes
Resolved Date Resolution May 19, 06
System Subsystem Cause Lifesaving Lifefloat
Description Due Date Resolved Provide one six person life float IAW Title 46 Subchapter W and local policy. This requirement must be completed prior to transiting with persons onboard. Feb 11, 06 Yes
Resolved Date Resolution May 19, 06
2318764
San Francisco, California
Apr 21, 05
Vessel Inspection - Approved Inspection
2318756
San Francisco, California
Apr 21, 05
Vessel Inspection - Approved Inspection
2336717
WASHINGTON, District of Columbia
Apr 18, 05
Incident Investigation - Agency Action Complete
2314888
San Francisco, California
Mar 18, 05
Vessel Inspection - Approved Inspection
12
0
System Subsystem Cause Deck/Cargo Cargo Transfer/Lightering (liquid)
Description Due Date Resolved Clean flame screens on vent on common vapor header. Apr 21, 05 Yes
Resolved Date Resolution Mar 21, 05 Operator corrected on the spot.
System Subsystem Cause Electrical Electrical Distribution System (service)
Description Due Date Resolved Properly blank off the unused circuit breaker (#6) on the main panel in cargo pump engine shack. Apr 21, 05 Yes
Resolved Date Resolution Apr 21, 05
System Subsystem Cause Engineering Compressed Air System (control)
Description Due Date Resolved Properly secure air receiver in cargo pump engine shack. Apr 21, 05 Yes
Resolved Date Resolution Apr 01, 05 Removed requirement and issued a different requirement on 01APR05 that required the operator to remove the air receiver completely.
System Subsystem Cause Deck/Cargo Cargo Stowage
Description Due Date Resolved Properly secure drum on stern. Must be completed prior to getting underway with persons onboard. Apr 21, 05 Yes
Resolved Date Resolution Mar 21, 05 Operator provided written attestation.
System Subsystem Cause Deck/Cargo Cargo Transfer/Lightering (liquid)
Description Due Date Resolved Properly secure fuel piping on starboard cargo pump engine. Apr 21, 05 Yes
Resolved Date Resolution Apr 21, 05
System Subsystem Cause Engineering Diesel Engine (auxiliary)
Description Due Date Resolved Prove proper operation of emergency fuel shut-off valve for the starboard cargo pump engine. Apr 21, 05 Yes
Resolved Date Resolution Mar 21, 05 Operator corrected on the spot.
System Subsystem Cause Lifesaving Lifejacket/PFD (Type I)
Description Due Date Resolved Provide 2 Type-I lifejackets IAW 46CFR199.620. Must be completed prior to getting underway with persons onboard. Apr 21, 05 Yes
Resolved Date Resolution Mar 21, 05 Operator provide receipt and written attestation.
System Subsystem Cause Deck/Cargo Cargo Transfer/Lightering (liquid)
Description Due Date Resolved Provide proof of annual calibration of all pressure gauges on cargo lines and pumps IAW 46CFR35.35-70. Apr 21, 05 Yes
Resolved Date Resolution Apr 21, 05
System Subsystem Cause Engineering Compressed Air System (control)
Description Due Date Resolved Remove the Husky 5 HP 26 gallon vertical compressor from the tank barge. The barge is restricted from operating the compressor at any time until removal from the barge. All air pressure shall be relieved from the pressure vessel and its electrical source properly disconnected. Cite: 46 CFR 54.01-5(c)(4) May 01, 05 Yes
Resolved Date Resolution Apr 21, 05
System Subsystem Cause Lifesaving Lifebuoys
Description Due Date Resolved Renew batteries in waterlight. Apr 21, 05 Yes
Resolved Date Resolution Mar 21, 05 Operator corrected on the spot.
System Subsystem Cause Lifesaving Lifebuoys
Description Due Date Resolved Stencil name of vessel and port on lifebuoy. Apr 21, 05 Yes
Resolved Date Resolution Mar 21, 05 Operator corrected on the spot.
System Subsystem Cause Operations/Management Cargo Transfer/Lightering
Description Due Date Resolved Vessel is permitted to offload all cargo at a port within the confines of San Francisco Bay and its tributaries at the first available opportunity. Following offload, vessel is restricted from conducting any cargo operations until a satisfactory COI inspection is completed. Yes
Resolved Date Resolution Apr 21, 05 Conducted a satisfactory COI inspection.
2307300
San Francisco, California
Mar 10, 05
Enforcement - Agency Action Complete
2307220
WASHINGTON, District of Columbia
Jan 12, 05
Incident Investigation - Agency Action Complete
2167520
San Francisco, California
Aug 05, 04
Facility Transfer Monitor - Approved Inspection
2039540
San Francisco, California
Apr 07, 04
Vessel Inspection - Approved Inspection
1983259
WASHINGTON, District of Columbia
Jan 12, 04
Incident Investigation - Agency Action Complete
1975447
Washington, District of Columbia
Dec 31, 03
Vessel Inspection - ASP Criteria Met
1942133
San Francisco, California
Oct 31, 03
Vessel Inspection - Approved Inspection
1929009
Warrenton, Oregon
Oct 24, 03
Vessel Inspection - Agency Action Complete
2
0
System Subsystem Cause Operations/Management Pollution Unknown
Description Due Date Resolved Provide valid Vessel Response Plan and Shipboard Oil Pollution Emergency Plan. This item is to be completed prior to loading of cargo. LEGACY COMPONENT DESC: Vessel Response Plan Nov 15, 03 Yes
Resolved Date Resolution Oct 29, 03
System Subsystem Cause Deck/Cargo Holds/Tanks Improper Installation
Description Due Date Resolved Repair and demonstrate operation of High Level and Overfill alarms. This item is to be completed prior to loading of cargo LEGACY COMPONENT DESC: Tank Level Monitoring Device Nov 15, 03 Yes
Resolved Date Resolution Oct 31, 03 Alarms tested sat.
Documents
Issued
Expires
Agency
Cargo Authority Attachment
October 23,2003
N/A
CERTIFICATE OF DOCUMENTATION
December 3,2021
January 31,2023
USCG
Certificate of Inspection
March 21,2005
October 24,2008
N/A
Certificate of Inspection - Amended
March 21,2005
October 24,2008
N/A
Classification Document
October 23,2008
October 23,2013
ABS
International Load Line Certificate
October 23,2008
October 23,2013
ABS
International Oil Pollution Prevention Certificate
October 24,2003
October 24,2008
N/A
Stability Letter
March 11,2004
N/A
Tonnage Certificate, International
January 23,2004
ABS