Andromeda
Print Q88   
IMO/VIN Callsign Flag Service Year
9352561 9HA3956 MALTA Tank Ship 2008
Activity# Port Date Activity - Description Deficiencies
6550952 San Diego, California Sep 29, 18 Vessel Inspection - Approved Inspection
6353749 TEXAS CITY, Texas Feb 24, 18 Vessel Inspection - Approved Inspection
5853484 San Pedro, California Apr 19, 16 Vessel Inspection - Approved Inspection
5055695 San Diego, California Jan 19, 15 Boarding - Agency Action Complete
5048352 San Diego, California Jan 17, 15 Vessel Inspection - Approved Inspection
4947268 WASHINGTON, District of Columbia Jul 16, 14 Incident Investigation - Agency Action Complete
4786421 San Pedro, California Jan 21, 14 Boarding - Agency Action Complete
4784662 San Pedro, California Jan 17, 14 Vessel Operational Control - Agency Action Complete
4676708 San Pedro, California Aug 12, 13 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Fire FightingStructural - A Class Divisions
DescriptionDue DateResolved
0710-ONE DOOR LEADING FROM OFFICERS MESS TO PANTRY/GALLEY AREA HAD A HOLDBACK ARRANGEMENT, ONE OTHER DOOR FROM CREWS MESS TO PANTRY/GALLEY HAD A HOLDBACK ARRANGEMENT. VSLS FCP SHOWED THOSE DOORS ARE TO BE SELF CLOSING. ISSUED 10C, 2ND TIME FOR THIS DEF.Yes
Resolved DateResolution
Aug 12, 13THE CREW REMOVED THE HOLDBACK ARRANGEMENTS.
4677327 San Pedro, California Aug 06, 13 Boarding - Agency Action Complete
4672691 San Pedro, California Aug 02, 13 Vessel Operational Control - Agency Action Complete
4668307 San Diego, California Jul 29, 13 Vessel Inspection - Approved Inspection
4668261 San Diego, California Jul 29, 13 Vessel Inspection - Approved Inspection
4454599 San Pedro, California Oct 12, 12 Vessel Inspection - Agency Action Complete
  5
SystemSubsystemCause
Fire FightingStructural - A Class Divisions
DescriptionDue DateResolved
0710-FIRE PREVENTION-DOORS REQUIRED TO BE SELF CLOSING SHALL NOT BE FITTED WITH HOLDBACK ARRANGEMENTS. FOUR DOORS AT THE GALLY AND MESSROOMS WERE IDENTIFIED TO BE SELF CLOSING ON VESSEL'S APPROVED FIRE CONTROL PLAN AND WERE INSTALLED WITH HOLDBACK ARRANGEMENTS. 74SOLAS(09)II-2/9.4.2.2 -10c-Oct 12, 12Yes
Resolved DateResolution
Oct 12, 12Vessel removed all holdback arrangements prior to departure of attending Marine Inspectors.
SystemSubsystemCause
EngineeringDiesel Engine (propulsion/auxiliary-electric)
DescriptionDue DateResolved
0750-FIRE PREVENTION-IN A SHIP IN WHICH OIL FUEL IS USED THE ARRANGEMENTS FOR THE STORAGE DISTRIBUTION AND UTILIZATION OF THE OIL FUEL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. EMERGENCY GENERATOR FUEL SUPPLY LINE IS LEAKING FROM FITTING. 74SOLAS(09)II-2/4.2.2 -10c-Oct 12, 12Yes
Resolved DateResolution
Oct 12, 12VESSEL CREW MEMBERS REPLACED NOZZLE FITTING ENSURING APPROPRIATE OPERATIONAL CONDITION.
SystemSubsystemCause
Deck/CargoMooring/Anchoring
DescriptionDue DateResolved
0999-OTHER(SAFETY IN GENERAL)-THE CONDITION OF THE SHIP AND IT'S EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF PRESENT REGULATIONS. ANCHOR ON STARBOARD SIDE NOTED WITH HYDRAULIC FUEL LEAK FROM RAM BRAKE SEAL. 74SOLAS(09)I/II(a) -10c-Oct 12, 12Yes
Resolved DateResolution
Oct 12, 12Vessel crew made adjustments to RAM on Anchor brake correcting the cause of Hydraulic fuel leak.
SystemSubsystemCause
Deck/CargoInert Gas SystemImproper/Lack of Maintenance
DescriptionDue DateResolved
0999-OTHER(SAFETY IN GENERAL)-THE CONDITION OF THE SHIP AND IT'S EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF PRESENT REGULATIONS. SCRUBBER SALT WATER FILL LINE HAS PINHOLE LEAKS AFTER TEMPORARY REPAIRS HAVE BEEN COMPLETED. 74SOLAS(09)I/II(a) -40ac-Yes
Resolved DateResolution
Jul 29, 13Vessel submitted Class Report attesting to repairs done to the scrubber salt water line.
SystemSubsystemCause
Pollution Prevention/ResponsePrevention EquipmentImproper/Lack of Maintenance
DescriptionDue DateResolved
1740-OIL DISCHARGE MON/CONTR SYSTEM-OIL FILTERING EQUIPMENT SHALL BE OF DESIGN AS WILL ENSURE THAT ANY OIL MIXTURE DISCHARGED INTO THE SEA HAS AN OIL CONTENT NOT EXCEEDING 15PPM. VESSEL UNABLE TO PROVIDE MANUFACTURER''S CALIBRATION CERTIFICATE ALIGNING WITH IOPP CERTIFICATE. MARPOL(11)AX.1/14.6 -17ac-Yes
Resolved DateResolution
Oct 14, 12The class granted an extension on the OCM calibration until the IOPP renewal survey.
4185623 San Diego, California Nov 23, 11 Vessel Inspection - Approved Inspection
3848762 Morgan City, Louisiana Sep 16, 10 Vessel Inspection - Approved Inspection
3428698 Morgan City, Louisiana Mar 08, 09 Vessel Inspection - Approved Inspection
Documents Issued Expires Agency
Certificate of Compliance - Tank Vessel October 12,2012 October 12,2014 N/A
Classification Document May 26,2015 April 7,2018 DNV GL
COC-TVE Annual November 23,2011 September 16,2012 SDCMS
COC-TVE Renewal September 16,2010 September 16,2012 N/A
International Load Line Certificate July 15,2015 April 7,2018 DNV GL
International Oil Pollution Prevention Certificate August 22,2017 April 7,2018 DNV GL
ISM - Document Of Compliance June 26,2013 September 12,2018 N/A
ISM - Safety Management Certificate July 24,2018 September 12,2023 DNV GL
Minimum Safe Manning Document May 27,2015 May 25,2020 MT
SOLAS Cargo Ship Safety Construction Certificate July 15,2015 April 7,2018 DNV GL
SOLAS Cargo Ship Safety Equipment Certificate July 15,2015 April 7,2018 DNV GL
SOLAS Cargo Ship Safety Radio Certificate July 15,2015 April 7,2018 DNV GL
Tonnage Certificate, International August 17,2015 DNV GL