IMO/VIN
Callsign
Flag
Service
Year
1234439
WCX3683
UNITED STATES
Tank Barge
2011
Activity#
Port
Date
Activity - Description
Deficiencies
6761332
STATEN ISLAND, New York
Jul 25, 19
Vessel Inspection - Approved Inspection
6719988
Savannah, Georgia
Jun 20, 19
Vessel Transfer Monitor - Agency Action Complete
6656106
STATEN ISLAND, New York
Apr 04, 19
Vessel Inspection - Approved Inspection
6517430
STATEN ISLAND, New York
Aug 20, 18
Vessel Inspection - Approved Inspection
6339852
Woods Hole, Massachusetts
Jan 18, 18
Vessel Transfer Monitor - Agency Action Complete
6288865
WASHINGTON, District of Columbia
Oct 14, 17
Incident Investigation - Agency Action Complete
6259641
STATEN ISLAND, New York
Sep 05, 17
Vessel Inspection - Agency Action Complete
6227186
Woods Hole, Massachusetts
Aug 02, 17
Vessel Inspection - Approved Inspection
6102611
STATEN ISLAND, New York
Mar 10, 17
Vessel Inspection - Approved Inspection
6056262
NEW HAVEN, Connecticut
Dec 12, 16
Facility Transfer Monitor - Approved Inspection
6049337
New Bedford, Massachusetts
Nov 29, 16
Facility Transfer Monitor - Approved Inspection
6042951
WASHINGTON, District of Columbia
Nov 17, 16
Incident Investigation - Agency Action Complete
6027519
STATEN ISLAND, New York
Oct 22, 16
Vessel Inspection - Approved Inspection
5975476
STATEN ISLAND, New York
Aug 18, 16
Vessel Inspection - Agency Action Complete
4
0
System Subsystem Cause Electrical Electrical Distribution System (service) Damaged By Earlier Event
Description Due Date Resolved A cable must not be spliced in a hazardous location. Replace wire run to hydraulic pump controller in-kind, or submit repair proposal for review. Yes
Resolved Date Resolution Sep 20, 16 Removed damage section of wire and moved hydraulic pump controller closer to centerline. Performed insulation resistance test (Megger test) with satisfactory results.
System Subsystem Cause Deck/Cargo Cargo Transfer/Lightering (liquid) Placed in Improper Service
Description Due Date Resolved The COI inspection shall be such as to ensure the vsl is in satisfactory condition and fit for service. P/V valves were not ready for service as a result of paint within their components. Service all P/V valves to ensure proper lift and re-seat. Hydro all prior to reinstall. Yes
Resolved Date Resolution Sep 20, 16 All P/V relief valves removed, serviced, hydrostatically tested (witnessed by ABS) and reinstalled. MIs verified proper function and reviewed hydro certificate.
System Subsystem Cause Electrical Electrical Distribution System (service) Placed in Improper Service
Description Due Date Resolved There must be ground detection for each ships service power system. The ground detection system on the generator switchboard was not monitoring grounds on one of the power phases. Repair or replace and ensure proper function. Yes
Resolved Date Resolution Sep 20, 16 Installed new ground detection system which was found in working condition.
System Subsystem Cause Electrical Electrical Distribution System (service)
Description Due Date Resolved When installed, the metallic armor or sheath must meet the installation reqs of Sec 25 of IEEE 45-2002. Armored sheathing on cabling fwd of mast was found discontinuous and worn. Repair armor or install bonding straps to make continuous. Repair damaged wire insulation prior to cargo ops. Provide repair proposal for modifications. Oct 19, 16 Yes
Resolved Date Resolution Sep 20, 16 Worn wire run to the anchor windlass was replaced. Damaged sheathing was patched with jumpers of replacement sheathing and secured with metallic wire ties.
5813228
BOSTON, Massachusetts
Feb 10, 16
Vessel Transfer Monitor - Approved Inspection
5830665
WASHINGTON, District of Columbia
Feb 06, 16
Incident Investigation - Agency Action Complete
5777049
STATEN ISLAND, New York
Dec 10, 15
Vessel Inspection - Approved Inspection
5751898
STATEN ISLAND, New York
Oct 27, 15
Vessel Inspection - Agency Action Complete
5206797
STATEN ISLAND, New York
Aug 05, 15
Vessel Inspection - Approved Inspection
5028778
STATEN ISLAND, New York
Nov 24, 14
Facility Transfer Monitor - Agency Action Complete
4983528
STATEN ISLAND, New York
Sep 15, 14
Vessel Inspection - Approved Inspection
4777856
STATEN ISLAND, New York
Jan 06, 14
Vessel Inspection - Approved Inspection
1
0
System Subsystem Cause Documentation Logs/Records
Description Due Date Resolved Vessel is required to provide verification that the vessel and its crew partake in a benzene monitoring program. Jan 21, 14 Yes
Resolved Date Resolution Jan 21, 14 Recieved medical reports from vessel indicating that all crew mbrs have undergone benzene exams within the past year.
4630037
WASHINGTON, District of Columbia
Jun 16, 13
Incident Investigation - Agency Action Complete
4557684
STATEN ISLAND, New York
Mar 28, 13
Enforcement - Agency Action Complete
4521569
WASHINGTON, District of Columbia
Jan 10, 13
Incident Investigation - Agency Action Complete
4495725
STATEN ISLAND, New York
Dec 04, 12
Vessel Inspection - Agency Action Complete
4265028
STATEN ISLAND, New York
Mar 16, 12
Vessel Inspection - Agency Action Complete
4256038
Woods Hole, Massachusetts
Mar 04, 12
Vessel Transfer Monitor - Approved Inspection
4125143
Woods Hole, Massachusetts
Aug 23, 11
Vessel Inspection - Approved Inspection
3
0
System Subsystem Cause Deck/Cargo Holds/Tanks Improper Installation
Description Due Date Resolved Demonstrate toxic calibration of portable meters to satisfaction of attending Marine Inspector. Prior to hazmat cargo or 07 Nov. (*required for 153 cargoes). Nov 07, 11 Yes
Resolved Date Resolution Oct 13, 11
System Subsystem Cause Deck/Cargo Vapor Control Systems Improper Installation
Description Due Date Resolved Install p/v valve for vcs as specified on approved plans. Oct 14, 11 Yes
Resolved Date Resolution Oct 13, 11
System Subsystem Cause Operations/Management Cargo Transfer/Lightering Improper Installation
Description Due Date Resolved Provide cargo tank coating documentation that coating as installed are copatible with all cargo's authorized by CG cargo authority C1-1103160 dtd 28SEP11. Nov 07, 11 Yes
Resolved Date Resolution Nov 02, 11 Cleared requirement per ABS Letter dated 24 Oct 2011. ABS approved carriage as authorized by USCG cargo authority issued 28 Sep 2011 C1-1103160. See Docs/Certs for this activity.
Documents
Issued
Expires
Agency
Cargo Authority Attachment
September 28,2011
N/A
CERTIFICATE OF DOCUMENTATION
September 29,2020
October 31,2021
USCG
Certificate of Fitness - Chemical Carrier
October 7,2011
October 7,2016
N/A
Certificate of Inspection
September 19,2016
September 19,2021
USCG
Certificate of Inspection - Amended
September 19,2016
September 19,2021
USCG
Classification Document
September 19,2016
October 6,2021
ABS
International Certificate of Fitness - Chemical
September 26,2016
September 19,2021
N/A
International Load Line Certificate
September 19,2016
October 6,2021
ABS
International Oil Pollution Prevention Certificate
September 26,2016
September 19,2021
N/A
Stability Letter
September 28,2011
N/A
Tonnage Certificate, International
August 17,2011
ABS
Tonnage Certificate, U.S.
August 17,2011
N/A