Rtc 100
Print Q88   
IMO/VIN Callsign Flag Service Year
1170443 UNITED STATES Tank Barge 2005
Activity# Port Date Activity - Description Deficiencies
7261815 STATEN ISLAND, New York Jul 20, 21 Vessel Inspection - Agency Action Complete
7071634 STATEN ISLAND, New York Oct 05, 20 Vessel Inspection - Approved Inspection
7046727 STATEN ISLAND, New York Aug 31, 20 Facility Transfer Monitor - Approved Inspection
6948724 STATEN ISLAND, New York May 05, 20 Vessel Inspection - Approved Inspection
6873247 STATEN ISLAND, New York Dec 11, 19 Facility Transfer Monitor - Approved Inspection
6732311 STATEN ISLAND, New York Jul 01, 19 Vessel Inspection - Approved Inspection
6706096 STATEN ISLAND, New York Jun 07, 19 Vessel Inspection - Approved Inspection
6711703 WASHINGTON, District of Columbia Jun 06, 19 Incident Investigation - Agency Action Complete
6520764 NEW HAVEN, Connecticut Aug 23, 18 Vessel Transfer Monitor - Agency Action Complete
6519429 NEW HAVEN, Connecticut Aug 17, 18 Vessel Transfer Monitor - Agency Action Complete
6394110 STATEN ISLAND, New York Apr 17, 18 Vessel Inspection - Approved Inspection
6291645 STATEN ISLAND, New York Oct 20, 17 Vessel Inspection - Approved Inspection
6244550 Woods Hole, Massachusetts Aug 17, 17 Vessel Inspection - Approved Inspection
6163810 STATEN ISLAND, New York May 31, 17 Vessel Inspection - Agency Action Complete
6139866 NEW HAVEN, Connecticut May 05, 17 Vessel Transfer Monitor - Agency Action Complete
6139844 New Bedford, Massachusetts May 05, 17 Facility Transfer Monitor - Approved Inspection
6144672 WASHINGTON, District of Columbia May 04, 17 Incident Investigation - Agency Action Complete
5955140 STATEN ISLAND, New York Jul 23, 16 Vessel Inspection - Agency Action Complete
5945150 STATEN ISLAND, New York Jul 18, 16 Vessel Inspection - Approved Inspection
5947137 BOSTON, Massachusetts Jul 09, 16 Vessel Transfer Monitor - Approved Inspection
5884123 NEW HAVEN, Connecticut May 20, 16 Facility Transfer Monitor - Approved Inspection
5809602 BOSTON, Massachusetts Feb 04, 16 Vessel Transfer Monitor - Approved Inspection
5112651 STATEN ISLAND, New York Apr 28, 15 Vessel Inspection - Agency Action Complete
  2
SystemSubsystemCause
ElectricalElectrical Distribution System (service)Design Flaw
DescriptionDue DateResolved
12 volt system is ungrounded and does not have ground detection. Must have ground detection capability in accordance with 46 CFR 111.05-25Jul 05, 15Yes
Resolved DateResolution
Jun 12, 15They had the 12 volt system rewired. They took the power source from the 120 volt system to power the nav lights which now have proper ground detection.
SystemSubsystemCause
ElectricalLighting (service)
DescriptionDue DateResolved
Deck lights in hazardous locations are required to be intrinsically safe, could not verify that the lighting onboard the RTC 100 was Class I Div I. Please provide proof that the lighting is either Class I Div I or replace the lights as necessary.Jul 05, 15Yes
Resolved DateResolution
Jul 02, 15Met the RTC 100 at the Phillips 66 facility and verified that the lights near the high velocity P/V were class one div one, also ensured proper installation and operation of the lighting, all sat.
5064415 WASHINGTON, District of Columbia Jan 18, 15 Incident Investigation - Agency Action Complete
5053783 STATEN ISLAND, New York Jan 15, 15 Vessel Inspection - Agency Action Complete
5048041 BOSTON, Massachusetts Jan 05, 15 Vessel Transfer Monitor - Approved Inspection
4981688 STATEN ISLAND, New York Sep 11, 14 Vessel Inspection - Agency Action Complete
  2
SystemSubsystemCause
EngineeringFuel Oil Service System
DescriptionDue DateResolved
Vessel currently has nonmetallic hoses on their generator that does not meet the standards of SAEJ 1942 IAW 46 CFR 56.60-25(4) b.Sep 30, 14Yes
Resolved DateResolution
Oct 28, 14MI visually confirmed installation of proper hoses that do not exceed 30 inches.
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
Vessel dos not meet the requirements of 46 CFR 32.50-5(b) that states: cargo pump pressure gauges shall be located at a point visible with respect to the pump controls.Sep 30, 14Yes
Resolved DateResolution
Sep 15, 14Vessel routed pressure gauges so that it is visible from the cargo controls.
4646925 WASHINGTON, District of Columbia Jul 03, 13 Incident Investigation - Agency Action Complete
4570663 STATEN ISLAND, New York Apr 17, 13 Vessel Inspection - Agency Action Complete
4471841 STATEN ISLAND, New York Oct 04, 12 Vessel Inspection - Agency Action Complete
4358052 STATEN ISLAND, New York Jun 27, 12 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
ElectricalElectric Generation Source (service)
DescriptionDue DateResolved
Vessel not fitted with overspeed trips. Required to install and test.Aug 27, 12Yes
Resolved DateResolution
Oct 04, 12T. Cowan attended vessel and witnessed proper overspeed trip installed and operational.
4265038 BOSTON, Massachusetts Mar 16, 12 Vessel Transfer Monitor - Agency Action Complete
4098202 STATEN ISLAND, New York Jul 29, 11 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Deck/CargoHolds/Tanks
DescriptionDue DateResolved
Replace vapor hose on the sludge tank vacuum pump after the condensate holding tank & the vapor hose running from the upper condensate tank to the vacuum pump. 46 CFR 32.55-20Aug 26, 11Yes
Resolved DateResolution
Aug 25, 11Received photos and letter from the barge captain stating the vapor hoses on the vacuum tank were replaced in kind.
3937027 STATEN ISLAND, New York Jan 19, 11 Vessel Transfer Monitor - Approved Inspection
3898962 WASHINGTON, District of Columbia Nov 25, 10 Incident Investigation - Agency Action Complete
3868929 WASHINGTON, District of Columbia Sep 09, 10 Incident Investigation - Agency Action Complete
3767874 STATEN ISLAND, New York Jun 16, 10 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
As per 46CFR32.50-5, vessel must have a pressure gauge installed on the #1 cargo pump.Sep 02, 10Yes
Resolved DateResolution
Aug 06, 10Rcvd email with attached photo showing proof of attached gauge on #1 cargo pump
3748476 NEW HAVEN, Connecticut May 26, 10 Vessel Transfer Monitor - Agency Action Complete
3697513 NEW HAVEN, Connecticut Mar 17, 10 Vessel Transfer Monitor - Agency Action Complete
3676064 NEW HAVEN, Connecticut Feb 05, 10 Vessel Transfer Monitor - Agency Action Complete
3675847 STATEN ISLAND, New York Feb 04, 10 Facility Transfer Monitor - Agency Action Complete
3661695 STATEN ISLAND, New York Jan 10, 10 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Construction/LoadlineHull
DescriptionDue DateResolved
Vsl sustained damage IWO port stern sideshell. Vsl shall make permanent repairs to damage prior to commercial cargo operations. Attending CG MI must inspect repairs and deem satisfactory prior to returning to commercial service.Yes
Resolved DateResolution
Jan 21, 10Vsl made satisfactory repairs tested to the satisfaction of CG and ABS.
3667451 WASHINGTON, District of Columbia Jan 10, 10 Incident Investigation - Agency Action Complete
3658452 NEW HAVEN, Connecticut Jan 04, 10 Vessel Transfer Monitor - Agency Action Complete
3607046 NEW HAVEN, Connecticut Oct 01, 09 Vessel Transfer Monitor - Agency Action Complete
3599949 NEW HAVEN, Connecticut Sep 21, 09 Vessel Transfer Monitor - Agency Action Complete
3591673 STATEN ISLAND, New York Sep 11, 09 Vessel Inspection - Agency Action Complete
3477632 STATEN ISLAND, New York May 11, 09 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Construction/LoadlineHullDesign Flaw
DescriptionDue DateResolved
The vessel had cracks in the fwd and aft rakes along the cargo tank trunks. This was a design flaw that developed over the course of operation on the vessel. JMS Engineering provided a repair proposal that had the vessel install gussets along the cargo trunks iwo the fwd and aft rakes.Yes
Resolved DateResolution
May 18, 09Repaired as written in the repair proposal submitted by JMS Engineering.
3472772 WASHINGTON, District of Columbia May 11, 09 Incident Investigation - Agency Action Complete
3464402 NEW HAVEN, Connecticut Apr 30, 09 Vessel Transfer Monitor - Agency Action Complete
3424254 STATEN ISLAND, New York Feb 26, 09 Vessel Inspection - Approved Inspection
3416566 NEW HAVEN, Connecticut Feb 11, 09 Vessel Transfer Monitor - Agency Action Complete
3401858 NEW HAVEN, Connecticut Jan 27, 09 Vessel Transfer Monitor - Agency Action Complete
3380850 NEW HAVEN, Connecticut Dec 16, 08 Vessel Transfer Monitor - Agency Action Complete
3212589 STATEN ISLAND, New York May 21, 08 Vessel Inspection - Agency Action Complete
3211674 STATEN ISLAND, New York May 20, 08 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
DocumentationCertificates/Documents
DescriptionDue DateResolved
Vessel is restricted to the carriage of grade A and Lower Grade Flammable or Combustible Liquids Identified in 46 CFR Table 30.25-1 as Pollution Category I and cargoes listed in the IBC Code identified as “Other Substances (OS)” until the Cargo Authority Attachment has been verified by the Marine Safety Center for suitability to carry cargoes regulated under MARPOL Annex II.Yes
Resolved DateResolution
Jun 26, 08Rescinded requirement, endorsed COI with separate cargo authorities specific to domestic and international service.
3177341 STATEN ISLAND, New York Apr 04, 08 Vessel Inspection - Agency Action Complete
3175359 NEW HAVEN, Connecticut Apr 01, 08 Vessel Transfer Monitor - Agency Action Complete
3159365 NEW HAVEN, Connecticut Mar 06, 08 Enforcement - Agency Action Complete
3159179 NEW HAVEN, Connecticut Mar 05, 08 Vessel Transfer Monitor - Agency Action Complete
3149865 STATEN ISLAND, New York Feb 19, 08 Vessel Inspection - Approved Inspection
3148114 WASHINGTON, District of Columbia Feb 15, 08 Incident Investigation - Agency Action Complete
3146375 New Bedford, Massachusetts Feb 12, 08 Vessel Transfer Monitor - Agency Action Complete
3110122 NEW HAVEN, Connecticut Dec 05, 07 Vessel Transfer Monitor - Agency Action Complete
3098436 NEW HAVEN, Connecticut Nov 14, 07 Facility Transfer Monitor - Agency Action Complete
3089959 NEW HAVEN, Connecticut Oct 30, 07 Vessel Transfer Monitor - Agency Action Complete
2950954 STATEN ISLAND, New York Jun 04, 07 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Deck/CargoVapor Control SystemsImproper/Lack of Maintenance
DescriptionDue DateResolved
Repace Pin on reducer for Vapor line starboard side manifoldJun 18, 07Yes
Resolved DateResolution
Jun 05, 07Cleared by CG inspector
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational SafetyDamaged By Earlier Event
DescriptionDue DateResolved
Replace missing lifeline stantions on portsideJun 18, 07Yes
Resolved DateResolution
Jun 05, 07Cleared by CG inspector
2692204 STATEN ISLAND, New York Jun 26, 06 Vessel Transfer Monitor - Approved Inspection
2674630 STATEN ISLAND, New York Jun 09, 06 Vessel Inspection - Approved Inspection
2602102 STATEN ISLAND, New York Mar 14, 06 Vessel Transfer Monitor - Approved Inspection
2597786 STATEN ISLAND, New York Mar 07, 06 Vessel Transfer Monitor - Approved Inspection
2363405 Woods Hole, Massachusetts May 20, 05 Vessel Inspection - Approved Inspection
2349262 Washington, District of Columbia May 04, 05 Vessel Inspection - Security Plan Approved by MSC
Documents Issued Expires Agency
Cargo Authority Attachment December 29,2008 N/A
CERTIFICATE OF DOCUMENTATION September 23,2021 October 31,2022 USCG
Certificate of Fitness - Chemical Carrier February 27,2009 June 16,2010 N/A
Certificate of Inspection September 30,2020 September 30,2025 USCG
Certificate of Inspection - Amended September 30,2020 September 30,2025 USCG
Classification Document August 2,2010 June 14,2015 ABS
International Load Line Certificate June 16,2005 June 16,2010 N/A
International Oil Pollution Prevention Certificate February 27,2009 June 16,2010 N/A
Stability Letter June 15,2005 N/A
Tonnage Certificate, International June 15,2005 N/A