Rtc 135
Print Q88   
IMO/VIN Callsign Flag Service Year
1089422 WCX3683 UNITED STATES Tank Barge 1999
Activity# Port Date Activity - Description Deficiencies
7630388 STATEN ISLAND, New York Feb 01, 23 Vessel Inspection - Approved Inspection
  10
SystemSubsystemCause
09 - Working and Living Conditions092 - Working Conditions
DescriptionDue DateResolved
A sign bearing the following legend in letters at least three inches high (except for the words “DANGER - BENZENE”, which must be printed in letters at least 50 percent larger than the other words) must be posted at each access to the regulated areas. Aft benzene sign is weathered and unreadable.Feb 23, 23Yes
Resolved DateResolution
Feb 27, 23
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
Cargo tanks in which Grade A, B, or C liquids are to be transported shall be fitted with either individual pressure-vacuum relief valves which shall extend to a reasonable height above the weather deck or shall be fitted with a venting system consisting of branch vent lines connected to a vent header which shall extend to a reasonable height above the weather deck and be fitted with a pressure-vacuum relief valve.#2 Port and #3 STBD P/V valve seized.Feb 09, 23Yes
Resolved DateResolution
Feb 09, 23Marine Inspector witnessed satisfactory test of P/V valves after they were replaced.
SystemSubsystemCause
07 - Fire SafetyN/A - No Subsystem
DescriptionDue DateResolved
Complete and simple instructions for the operation of the system must be located in a conspicuous place. Instructions not posted. 46 CFR 95.15-10 (h)Feb 23, 23Yes
Resolved DateResolution
Feb 27, 23
SystemSubsystemCause
07 - Fire SafetyN/A - No Subsystem
DescriptionDue DateResolved
Cylinders shall be securely fastened and supported and where necessary, protect against injury. Co2 cylinder for paint locker not secured. Rectify within 7 days. 46 CFR 95.15-20(d)Feb 16, 23Yes
Resolved DateResolution
Feb 27, 23
SystemSubsystemCause
13 - Propulsion and Auxiliary MachineryN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
Each conductor of a control, interlock, or indicator circuit must be disconnected from all sources of potential by a disconnect device independent of the motor controller disconnect device. Generator switchboard was not fitted with a safety interlock. Rectify within 7 days.Feb 16, 23Yes
Resolved DateResolution
Feb 27, 23
SystemSubsystemCause
07 - Fire SafetyN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
Each fire extinguisher shall be marked with a number and the location where stowed shall be marked in corresponding numbers in atleast 1/2 inch figures. Multiple fire extinguishers were not properly labeled.Feb 23, 23Yes
Resolved DateResolution
Feb 27, 23
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
The high-level alarm must activate a visible alarm so that it can be seen on the vessel where cargo is transfer is controlled. #2 high-level alarm light failed to illuminate during testing.Mar 09, 23Yes
Resolved DateResolution
Feb 09, 23Marine Inspector witness proper illumination of alarm, after vessel replaced light.
SystemSubsystemCause
03 - Water/Weathertight ConditionsN/A - No Subsystem
DescriptionDue DateResolved
The means for securing doors weathertight shall consist of clamping devices so that doors can be fitted to the equivalent strength to the unpierced bulkhead and weathertight when closed. All watertight doors were found to have some of their dogs seized in the open position, unable to close and create a weather tight seal for each space. Restriced to lakes bays and sounds route until rectified.Mar 09, 23Yes
Resolved DateResolution
Feb 27, 23
SystemSubsystemCause
03 - Water/Weathertight ConditionsN/A - No SubsystemImproper/Lack of Maintenance
DescriptionDue DateResolved
The structural arrangement in double bottom and other tanks shall be such as to permit the free passage of air and gases from all parts of the tanks to vent pipes. FWD ballast tank goose neck vent closure is seized in the closed position.Feb 24, 23Yes
Resolved DateResolution
Feb 27, 23
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No Subsystem
DescriptionDue DateResolved
The tank overfill alarm must activate a visible alarm so that it can be seen on the vessel where cargo transfer is controlled. The overfill alarm light for the #4 stbd cargo tank light did not illuminate during testing.Mar 09, 23Yes
Resolved DateResolution
Feb 09, 23Marine Inspector witnessed satisfactory operation of light after vessel replaced light.
7543958 STATEN ISLAND, New York Aug 23, 22 Vessel Inspection - Approved Inspection
7446137 BOSTON, Massachusetts May 08, 22 Vessel Transfer Monitor - Approved Inspection
7446923 WASHINGTON, District of Columbia May 01, 22 Incident Investigation - Agency Action Complete
7401154 STATEN ISLAND, New York Feb 24, 22 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
09 - Working and Living Conditions092 - Working ConditionsDamaged By Earlier Event
DescriptionDue DateResolved
Each electric cable of an intrinsically safe system must Be 50 mm (2 inches) or more from cable of non-intrinsically safe circuits, partitioned by a grounded metal barrier from other non-intrinsically safe electric cables, or a shielded or metallic armored cable; and Not contain conductors for non-intrinsically safe systems. MI found broken stuffing tube leading into metal junction box and exposed wiresMar 25, 22Yes
Resolved DateResolution
Mar 16, 22Recieved photo evidence that broken stuffing tube leading into metal junction box and exposed wires was satifactory repaired.
7269484 WASHINGTON, District of Columbia Jul 27, 21 Incident Investigation - Agency Action Complete
7149074 STATEN ISLAND, New York Mar 01, 21 Vessel Inspection - Approved Inspection
  8
SystemSubsystemCause
01 - Certificates & Documentation012 - Crew Certificates
DescriptionDue DateResolved
EACH PERSON DESIGNATED AS A PERSON IN CHARGE SHALL HAVE SUFFICIENT TRAINING AND EXPERIENCE WITH THE RELEVANT CHARACTERISTICS OF THE VESSEL ON WHICH THEY ARE A PIC. THE PERSON DESIGNATED AS BARGE CAPTAIN ADMITTED TO NOT CONDUCTING TESTS REQUIRED PRIOR TO THE TRANSFER, WHILE ANOTHER PIC WAS UNAWARE OF WHERE THE HIGH LEVEL/OVERFILL ALARMS FOR MULTIPLE TANKS WERE LOCATED. PROVIDE REPORT OF TRAINING OR ASSIGNMENT OF QUALIFIED/TRAINED PERSONNEL. 33CFR155.170(a)(1)Yes
Resolved DateResolution
Mar 22, 21Received letter from company attesting to training of the crew and a write-up issued to the captain.
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No Subsystem
DescriptionDue DateResolved
EACH TANK SHALL BE FITTED W/A SAFETY RELIEF VALVE OPERATING IAW THIS PART. FOUR OF THE FIVE VACUUM VALVES WERE STUCK UPON INSPECTION. 46CFR38.10-15Yes
Resolved DateResolution
Mar 01, 21Barge captain removed the paint causing the vacuum side to stick prior to MI leaving the vessel.
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No Subsystem
DescriptionDue DateResolved
EACH VAPOR HOSE SHALL BE TESTED IAW PARAGRAPHS b, c, AND f OF THIS SECTION. THE BARGES VAPOR HOSES WERE LAST TESTED IN JANUARY 2020. TEST VAPOR HOSES PRIOR TO USE. 33CFR156.170(g)(1)Yes
Resolved DateResolution
Mar 04, 21Verified vapot hoses had been properly hydrostatically tested.
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No Subsystem
DescriptionDue DateResolved
EACH VESSEL VAPOR COLLECTION FLANGE FACE MUST HAVE A PERMANENT STUD, THAT IS AT LEAST 1/2" IN DIAMETER AND 1" LONG, AT THE TOP ALONG THE FLANGE FACE. MULTIPLE REDUCERS ON THE VESSEL WERE MISSING THE STUD OR IT WAS LOCATED BETWEEN THE 2 AND 3 O'CLOCK POSITIONS, NOT THE TOP OF THE FLANGE FACE. CORRECT PRIOR TO UTILIZING THE CONNECTIONS. 46CFR39.2001(j)Yes
Resolved DateResolution
Mar 16, 21Photographs sent to MI, demonstrating the rectification.
SystemSubsystemCause
02 - Structural ConditionsN/A - No Subsystem
DescriptionDue DateResolved
NO CARGO TANK HATCHES SHALL BE OPEN W/O FLAME SCREENS. CARGO TANK 2P WAS MISSING A SCREW/BOLT FROM THE VIEWING GLASS SURROUND, THUS RELEASING VAPORS INTO THE HAZARDOUS ZONE. NO CARGO IN THE DESCRIBED TANK. 46CFR35.30-10Yes
Resolved DateResolution
Mar 01, 21Screw replaced and no vapors detected leaking viewing port afterwards.
SystemSubsystemCause
08 - AlarmsN/A - No Subsystem
DescriptionDue DateResolved
OVERFILL ALARMS SHALL ACTIVATE AUDIBLE AND VUSUAL INDICATORS. 3P AND 1S HAD VISUAL BULBS NOT LIGHTING UP. CORRECT PRIOR TO LOADING THOSE TANKS. 33CFR155.480/46CFR39.2009Yes
Resolved DateResolution
Mar 01, 21VIDEO OF THE BULBS LIGHTING WAS SEN T TO THE SEC NY DEEP DRAFT/CARGO SUPERVISOR.
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No Subsystem
DescriptionDue DateResolved
THE EMERGENCY MEANS OF SHUT-DOWN SHALL BE OPERABLE. NONE OF THE EMERGENCY SHUTDOWNS WERE OPERABLE. VESSEL PROHIBITTED FROM DISCHARGE USING INSTALLED CARGO PUMPS UNTIL PROPER OPERATION DEMONSTRATED IN THE PRESENCE OF A CGMI. 33CFR156.120(f)Yes
Resolved DateResolution
Mar 04, 21Witnessed operational test of the emergency shut down.
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No Subsystem
DescriptionDue DateResolved
TRANSFER HOSES FOR OIL SHALL MEET 33CFR154.500. THE HOSES WERE NOT MARKED WITH THE PROPER TEST DATES. TEST PRIOR TO USE. 33CFR155.800Yes
Resolved DateResolution
Mar 04, 21Verified cargo hoses were properly marked with last hydrostatic test test.
6961570 STATEN ISLAND, New York May 27, 20 Vessel Inspection - Administrative Action
6935537 WASHINGTON, District of Columbia Apr 05, 20 Incident Investigation - Agency Action Complete
7153599 BOSTON, Massachusetts Mar 04, 20 Vessel Inspection - Approved Inspection
6818753 Woods Hole, Massachusetts Sep 18, 19 Vessel Inspection - Approved Inspection
6788993 STATEN ISLAND, New York Aug 20, 19 Vessel Inspection - Administrative Action
  1
SystemSubsystemCause
06 - Cargo Operations Including EquipmentN/A - No Subsystem
DescriptionDue DateResolved
Conduct a permanent repair the cargo drop pipe line in way of No. 4 cargo tank. Prior to cargo operations.Yes
Resolved DateResolution
Jan 21, 20
6590909 STATEN ISLAND, New York Dec 03, 18 Vessel Inspection - Approved Inspection
6355050 STATEN ISLAND, New York Feb 14, 18 Vessel Inspection - Approved Inspection
6353651 USCG Air Station, Massachusetts Feb 12, 18 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Deck/CargoMooring/AnchoringImproper/Lack of Maintenance
DescriptionDue DateResolved
While retrieving the tank barge's anchor, the anchor wire line broke resulting in the loss of the vessel's anchor. Vessel is to provide and install a new anchor.Feb 19, 18Yes
Resolved DateResolution
Feb 14, 18The anchor and chain up to and including the socket which attaches to wire rope was replaced in kind.
6355616 WASHINGTON, District of Columbia Feb 12, 18 Incident Investigation - Agency Action Complete
6324337 STATEN ISLAND, New York Dec 14, 17 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
ElectricalElectrical Distribution System (service)Improper Installation
DescriptionDue DateResolved
Provide ground deteaction for 110V panel.Jan 15, 18Yes
Resolved DateResolution
Dec 19, 17Ground detection provided.
6182164 STATEN ISLAND, New York Jun 21, 17 Vessel Inspection - Agency Action Complete
6156001 STATEN ISLAND, New York May 26, 17 Vessel Inspection - Approved Inspection
6118549 STATEN ISLAND, New York Apr 05, 17 Vessel Inspection - Approved Inspection
6027559 STATEN ISLAND, New York Oct 22, 16 Vessel Inspection - Agency Action Complete
5908014 WASHINGTON, District of Columbia Dec 12, 15 Incident Investigation - Agency Action Complete
5772477 STATEN ISLAND, New York Dec 01, 15 Vessel Inspection - Approved Inspection
5751895 STATEN ISLAND, New York Oct 27, 15 Vessel Inspection - Agency Action Complete
5030006 BATON ROUGE, Louisiana Nov 24, 14 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Deck/CargoBallast
DescriptionDue DateResolved
Armature pump seal failed on the port ballast water pump. Engineers bypassed the pump to maintain ballast operations.Nov 23, 14Yes
Resolved DateResolution
Nov 24, 14Pump was replaced and tested. ALL SAT. CG-835 rescinded.
5030154 WASHINGTON, District of Columbia Nov 23, 14 Incident Investigation - Agency Action Complete
5013349 ST PETERSBURG, Florida Oct 28, 14 Enforcement - Agency Action Complete
5013349 Tampa, Florida Oct 28, 14 Enforcement - Agency Action Complete
5015172 WASHINGTON, District of Columbia Oct 22, 14 Incident Investigation - Agency Action Complete
5006037 ST PETERSBURG, Florida Oct 16, 14 Enforcement - Agency Action Complete
5006037 Tampa, Florida Oct 16, 14 Enforcement - Agency Action Complete
4998369 WASHINGTON, District of Columbia Oct 02, 14 Incident Investigation - Agency Action Complete
4923135 ST PETERSBURG, Florida Jul 15, 14 Vessel Inspection - Agency Action Complete
4923135 Tampa, Florida Jul 15, 14 Vessel Inspection - Agency Action Complete
4826066 WASHINGTON, District of Columbia Mar 26, 14 Incident Investigation - Agency Action Complete
4775971 New Orleans, Louisiana Jan 06, 14 Vessel Inspection - Approved Inspection
  3
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)
DescriptionDue DateResolved
Prove proper operation of all cargo pump prime mover emergency stops prior to discharging of cargo.Yes
Resolved DateResolution
Jan 15, 16MI conducted two separate functional test on the cargo pump prime mover emergency stops with satisfactory results.
SystemSubsystemCause
Deck/CargoHolds/Tanks
DescriptionDue DateResolved
Prove proper operation of all cargo tank P/V valves prior to loading/discharging cargo.Yes
Resolved DateResolution
Jan 09, 14MI attended vsl and verified the cargo tank P/V valves were operational w/number 1 centerline replaced.
SystemSubsystemCause
Deck/CargoVapor Control Systems
DescriptionDue DateResolved
Prove proper operation of visual and audible high level/overfill alarms prior to loading of cargo.Yes
Resolved DateResolution
Jan 09, 14MI tested all high level and overfill alarms with satisfactory results.
4607507 New Orleans, Louisiana May 28, 13 Vessel Inspection - Approved Inspection
  1
SystemSubsystemCause
Deck/CargoMooring/Anchoring
DescriptionDue DateResolved
Conduct permanent anchor repairs to vessel after loss of anchor, prior to operating. Provide documentation of repairs to attending marine inspector.Yes
Resolved DateResolution
May 31, 13Received proper documentation of windlass repair and installation of new anchor.
4567112 Jacksonville, Florida Apr 11, 13 Vessel Transfer Monitor - Approved Inspection
4497251 STATEN ISLAND, New York Nov 25, 12 Vessel Inspection - Agency Action Complete
4465381 WASHINGTON, District of Columbia Oct 16, 12 Incident Investigation - Agency Action Complete
4334889 STATEN ISLAND, New York May 29, 12 Vessel Inspection - Agency Action Complete
4259148 NEW HAVEN, Connecticut Mar 07, 12 Vessel Transfer Monitor - Agency Action Complete
4212547 STATEN ISLAND, New York Dec 22, 11 Vessel Inspection - Agency Action Complete
4200414 NEW HAVEN, Connecticut Dec 02, 11 Vessel Transfer Monitor - Agency Action Complete
4166532 STATEN ISLAND, New York Sep 09, 11 Vessel Inspection - Agency Action Complete
4074449 STATEN ISLAND, New York Jul 08, 11 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
Deck/CargoBallast
DescriptionDue DateResolved
#1&4 Stbd ballast tanks had some pitted areas bellow the bellmouth. Repair or replace.Jul 14, 11Yes
Resolved DateResolution
Jul 12, 11GMD Brooklyn yard clad welded the pitted areas and added a waste place to prevent future corrosion on all ballast tanks bellow the bellmouths.
3919252 STATEN ISLAND, New York Jan 03, 11 Vessel Inspection - Agency Action Complete
3684005 STATEN ISLAND, New York Feb 02, 10 Facility Transfer Monitor - Agency Action Complete
3639721 NEW HAVEN, Connecticut Nov 25, 09 Vessel Transfer Monitor - Agency Action Complete
3626736 NEW HAVEN, Connecticut Nov 02, 09 Vessel Transfer Monitor - Agency Action Complete
3622576 NEW HAVEN, Connecticut Oct 27, 09 Vessel Transfer Monitor - Agency Action Complete
3610773 STATEN ISLAND, New York Oct 14, 09 Vessel Inspection - Agency Action Complete
3561555 STATEN ISLAND, New York Aug 14, 09 Vessel Inspection - Agency Action Complete
3511433 STATEN ISLAND, New York Jun 22, 09 Vessel Inspection - Agency Action Complete
  4
SystemSubsystemCause
Operations/ManagementLog/Records
DescriptionDue DateResolved
During entire transit from Port Redding, NJ to the deignated discharge terminal in New Haven, CT, maintain a sounding log with recorded soundings of the stern void every hour until safely moored at the discharge terminal.Jun 30, 09Yes
Resolved DateResolution
Aug 21, 09
SystemSubsystemCause
StabilityWatertight Integrity
DescriptionDue DateResolved
Prior to completion of loading and departure from moorings at the Hess Terminal, provide a statement or verbal verification of soundings for the stern void, starboard to ensure condition prior to getting underway.Jun 23, 09Yes
Resolved DateResolution
Aug 21, 09
SystemSubsystemCause
Operations/ManagementNavigation Safety
DescriptionDue DateResolved
Provide a detailed transit plan for the RTC 135 upon completion of loading at Hess Terminal, Port Redding, NJ to the designated discharge terminal in New Haven, CT.Jun 23, 09Yes
Resolved DateResolution
Aug 21, 09
SystemSubsystemCause
Deck/CargoBallast
DescriptionDue DateResolved
Upon completion of discharge return the RTC 135 to a designated yard and provide a marine chemist certificate for the stern void certifying the space safe for entry and arrange for Coast Guard internal examination to further evaluate damage.Jun 30, 09Yes
Resolved DateResolution
Aug 21, 09
3514499 WASHINGTON, District of Columbia Jun 22, 09 Incident Investigation - Agency Action Complete
3472400 NEW HAVEN, Connecticut May 11, 09 Vessel Transfer Monitor - Agency Action Complete
3462830 NEW HAVEN, Connecticut Apr 27, 09 Vessel Transfer Monitor - Agency Action Complete
3442829 STATEN ISLAND, New York Mar 30, 09 Vessel Inspection - Approved Inspection
3350714 STATEN ISLAND, New York Oct 22, 08 Vessel Inspection - Agency Action Complete
3178007 NEW HAVEN, Connecticut Apr 05, 08 Vessel Transfer Monitor - Agency Action Complete
3173539 NEW HAVEN, Connecticut Mar 29, 08 Vessel Transfer Monitor - Agency Action Complete
3157642 NEW HAVEN, Connecticut Mar 03, 08 Vessel Transfer Monitor - Agency Action Complete
3134173 Woods Hole, Massachusetts Jan 22, 08 Enforcement - Agency Action Complete
3134032 WASHINGTON, District of Columbia Jan 20, 08 Incident Investigation - Agency Action Complete
3126890 WASHINGTON, District of Columbia Nov 21, 07 Incident Investigation - Agency Action Complete
3093790 STATEN ISLAND, New York Nov 06, 07 Vessel Inspection - Agency Action Complete
2990199 STATEN ISLAND, New York Jul 10, 07 Vessel Inspection - Agency Action Complete
2970419 Woods Hole, Massachusetts Jun 22, 07 Vessel Transfer Monitor - Approved Inspection
2802822 STATEN ISLAND, New York Oct 18, 06 Vessel Inspection - Approved Inspection
2561350 WASHINGTON, District of Columbia Dec 25, 05 Incident Investigation - Agency Action Complete
2513965 STATEN ISLAND, New York Oct 13, 05 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
EngineeringDiesel Engine (auxiliary)Improper/Lack of Maintenance
DescriptionDue DateResolved
Main hydraulic pump engine overspeed trip sending has separated from the accessory drive and will no longer function as designed. Properly repair manufacturer installed safety device prior to operating engine.Yes
Resolved DateResolution
Oct 14, 05Proper repairs completed.
2492472 WASHINGTON, District of Columbia Sep 12, 05 Incident Investigation - Agency Action Complete
2349109 Washington, District of Columbia May 04, 05 Vessel Inspection - Security Plan Approved by MSC
2313999 NEW HAVEN, Connecticut Mar 18, 05 Vessel Transfer Monitor - Agency Action Complete
2315141 NEW HAVEN, Connecticut Mar 18, 05 Vessel Transfer Monitor - Agency Action Complete
2293641 NEW HAVEN, Connecticut Feb 16, 05 Vessel Transfer Monitor - Agency Action Complete
2225291 STATEN ISLAND, New York Oct 21, 04 Vessel Inspection - Agency Action Complete
2197507 NEW HAVEN, Connecticut Sep 16, 04 Vessel Transfer Monitor - Agency Action Complete
2099500 STATEN ISLAND, New York Jun 15, 04 Vessel Inspection - Agency Action Complete
1980246 Washington, District of Columbia Dec 31, 03 Vessel Inspection - Security Plan Approved by MSC
1968206 STATEN ISLAND, New York Dec 22, 03 Vessel Inspection - Agency Action Complete
1963874 PHILADELPHIA, Pennsylvania Dec 13, 03 Facility Transfer Monitor - Agency Action Complete
1937933 PHILADELPHIA, Pennsylvania Oct 04, 03 Vessel Operational Control - Agency Action Complete
1922141 WASHINGTON, District of Columbia Oct 03, 03 Incident Investigation - Agency Action Complete
1758769 PHILADELPHIA, Pennsylvania Mar 18, 03 Enforcement - Administrative Action
1758762 PHILADELPHIA, Pennsylvania Mar 08, 03 Vessel Transfer Monitor - Administrative Action
1732043 STATEN ISLAND, New York Jan 17, 03 Vessel Inspection - Approved Inspection
  2
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational Safety
DescriptionDue DateResolved
Make permanent/proper repairs to broken/wasted railing above port manifold - to be corrected by vessel's next gas free opportunity or next drydock (whichever comes first). LEGACY COMPONENT DESC: Deck RailYes
Resolved DateResolution
Oct 13, 05Railings were inspected satisfactorily during the annual inspection.
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
Make permanent/proper repairs to emergency cargo pump engine shutdowns LEGACY COMPONENT DESC: Emergency Control Systems (tank barges)Feb 16, 03Yes
Resolved DateResolution
Jan 17, 03Confirmed repair
1715213 PHILADELPHIA, Pennsylvania Dec 03, 02 Facility Transfer Monitor - Approved Inspection
1630846 STATEN ISLAND, New York Jun 14, 02 Vessel Inspection - Approved Inspection
  4
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational Safety
DescriptionDue DateResolved
Dewater #2-4 P/S double bottom ballast tanks, so that scheduled Internal Structual exam can be conducted in a safe manner.Dec 10, 02Yes
Resolved DateResolution
Oct 23, 02
SystemSubsystemCause
Deck/CargoCargo Transfer/Lightering (liquid)Improper/Lack of Maintenance
DescriptionDue DateResolved
Make permanent repairs to leaking hydraulic pipline that runs hydraulic pumps used for dewatering all ballast tanks. Correct prior to departure from tri-state facility pier, Perth Amboy, NJ. LEGACY COMPONENT DESC: PipingYes
Resolved DateResolution
Jun 15, 02
SystemSubsystemCause
Accommodation/Occupational SafetyOccupational SafetyDesign Flaw
DescriptionDue DateResolved
Place portable ladders in # 5 P/S wing access tanks. This will safely allow access to double bottom tanks.Yes
Resolved DateResolution
Oct 23, 02
SystemSubsystemCause
Pollution Prevention/ResponsePrevention Equipment
DescriptionDue DateResolved
Submit to USCG the specific description of the materials used including the # of hoses and clamps used comparing the SAE spec's of the materials with those listed in the 46CFR 56.60 regs B 4&5. LEGACY COMPONENT DESC: Cargo Monitor/Control SystemJun 21, 02Yes
Resolved DateResolution
Jun 20, 02Submitted specs on hoses and clamps used in hydraulic dewatering system for ballast tanks.
1617116 PHILADELPHIA, Pennsylvania May 13, 02 Facility Transfer Monitor - Approved Inspection
1613504 PHILADELPHIA, Pennsylvania May 06, 02 Enforcement - Agency Action Complete
1613494 PHILADELPHIA, Pennsylvania May 02, 02 Facility Transfer Monitor - Agency Action Complete
1479877 PHILADELPHIA, Pennsylvania Jan 15, 02 Vessel Transfer Monitor - Agency Action Complete
1480344 STATEN ISLAND, New York Dec 06, 01 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
ElectricalLighting (service)Improper/Lack of Maintenance
DescriptionDue DateResolved
Fix deck lights on fwd deck mastJan 06, 02Yes
Resolved DateResolution
Jan 11, 02Deck lights fixed.
505787 PHILADELPHIA, Pennsylvania Oct 30, 01 Vessel Transfer Monitor - Agency Action Complete
459207 PHILADELPHIA, Pennsylvania Oct 04, 01 Vessel Transfer Monitor - Administrative Action
456676 PHILADELPHIA, Pennsylvania Aug 03, 01 Vessel Transfer Monitor - Agency Action Complete
1604839 WASHINGTON, District of Columbia May 04, 01 Incident Investigation - Agency Action Complete
517531 NEW HAVEN, Connecticut Apr 07, 01 Vessel Transfer Monitor - Agency Action Complete
1373323 STATEN ISLAND, New York Dec 12, 00 Vessel Inspection - Agency Action Complete
1427876 STATEN ISLAND, New York Nov 04, 00 Vessel Inspection - Agency Action Complete
488199 STATEN ISLAND, New York Sep 21, 00 Vessel Transfer Monitor - Agency Action Complete
441827 STATEN ISLAND, New York Sep 21, 00 Vessel Transfer Monitor - Agency Action Complete
441139 PHILADELPHIA, Pennsylvania Mar 10, 00 Vessel Transfer Monitor - Agency Action Complete
133751 WASHINGTON, District of Columbia Feb 26, 00 Incident Investigation - Agency Action Complete
1438953 STATEN ISLAND, New York Jan 15, 00 Vessel Inspection - Agency Action Complete
1372839 Mobile, Alabama Dec 10, 99 Vessel Inspection - Agency Action Complete
  1
SystemSubsystemCause
DocumentationUnknown
DescriptionDue DateResolved
Vessel is prohibited from onloading cargo until the vessel's oil transfer procedures have been approved by the cognizant OCMI Jan 10, 00Yes
Resolved DateResolution
Jan 03, 00
Documents Issued Expires Agency
Cargo Authority Attachment June 13,2017 N/A
CERTIFICATE OF DOCUMENTATION October 3,2022 October 31,2023 USCG
Certificate of Inspection October 27,2004 October 27,2009 N/A
Certificate of Inspection - Amended October 27,2004 October 27,2009 N/A
Classification Document October 3,2014 December 31,2019 ABS
International Load Line Certificate October 3,2014 December 31,2019 ABS
International Oil Pollution Prevention Certificate November 23,2015 September 14,2016 SECNY
Load Line Certificate (Coastwise) December 10,1999 ABS
Stability Book January 15,2020 ABS
Tonnage Certificate, International January 31,2020 ABS
Tonnage Certificate, U.S. January 31,2020 ABS